VELOX 4000 INT SERIES 4200 INT - 4400 INT Intelligent Analog Fire Alarm Control Panels integrated with Paging Microphone Console and Fire Telephone Handset • Five programmable LED indicators on the panel • Dedicated RS232 serial port for PC or modem connection • User-friendly menu and navigation keys • Multiple language display options • Variable Time Communication (VTC) Protocol VOICE ALARM & MASS NOTIFICATION • Touch screen paging console with in-built loudspeaker • Monochrome and colour touch screen panels • Display of all system faults and incidents on the control panel • Monitored handheld microphone • Audio routing, zone selection, and volume control from the paging microphone console • Simultaneous routing of up to 48 high-fidelity audio channels via digital signal processors • Up to 8192 voice evacuation zones • Voice alarm messages with professional audio quality EMERGENCY VOICE COMMUNICATION • Monitored fire telephone handset • Up to 8 master handsets on a network • Up to 256 communication lines • Disable refuge system • Addressable, monitored fire telephone jack on the fire detection and alarm loop FIRE DETECTION & ALARM APPLICATION • Up to 2 fire detection and alarm loops on 4200 INT & 4 loops on 4400 INT VELOX 4000 INT is a series of analogue addressable fire alarm control panels that function as control and indicating equipment for a range of fire detection and alarm devices. The fire alarm control panel is the central device in a life safety system involving fire detection, encompassing additional control panels, repeater panels, mimic panels, remote control and display terminals, manual call points, smoke and heat detectors, sounders, beacons, and relays. TThe 4000 INT series is available in two models—4200 INT and 4400 INT—with provi - sions for 2 and 4 loops, respectively. The fire alarm control panels are integrated seamlessly with ATEIS mass notification and emergency communication systems to house all corresponding control and monitoring equipment within a single enclosure. • Up to 240 devices per loop • Up to 200 fire alarm control panels on a network • Up to 200 fire zones per fire alarm control panel • Up to 1000 fire zones in a network of fire alarm control panels • Loop length extendable up to 6 km, subject to load calculations • Up to 1000 event logs per panel for diagnosis of fault conditions • IP30 protection • ‘Soft’ and ‘Safe’ addressing features • Complex ‘Cause & Effect’ programming options ATEÏS Middle East FZCO. The integrated paging microphone console allows audio routing, call paging, message broadcasting, and P.O. Box: 293640 Dubai United Arab Emirates Tel: +971 4 3262730 Fax: +971 4 3262731 Email: [email protected] http://www.ateis.ae 1 VELOX 4000 INT SERIES control of digital signal processing parameters via a user-friendly interface. The integrated fire telephone handset enables secure, full duplex emergency voice communication with outstation handsets on a fire telephone network. The emergency voice communication system (EVCS) provides assistance to fire fighters during emergencies in high-rise buildings, particularly in situation were radio communication may get disrupted. VELOX 4000 INT is ideal for medium-, and large-scale installations in properties ranging from but not limited to commercial and residential spaces such as hotels, malls, and apartments; infrastructure developments such as airports and railway stations; and special-purpose buildings such as schools and places of worship. PHYSICAL CONSTRUCTION & ASSEMBLY The 4200 INT, 4400 INT and 4800 INT control panels are made of metal and provide the option of surface or flush mounting and different finishes such as stainless steel or RAL colors. Sufficient mounting knockouts are provided to accommodate all wiring requirements. The control panel housing has IP30 protection and restricts access to the control buttons without a key or special tool. The front-side of the panel has a graphic LCD screen with LED status indicators, control buttons, alphanumeric keypad, and navigation buttons. The fire alarm control panels are available as part of an integrated unit comprising the panel itself, paging microphone for public address and voice alarm, and fire telephone master handset for emergency communications, all housed in a steel enclosure. Depending on requirements, the 4200 INT and 4400 INT can either be used as stand-alone fire alarm control panels or expanded to have integrated voice evacuation and voice communications features. The panel has two 12V batteries installed at the bottom of the enclosure for standby operation up to 24 hours, followed by 30 minutes of alarm. The enclosure can house larger batteries for a 72-hour backup, followed by 30 minutes of alarm. The integrated paging microphone console is attached with a monitored handheld microphone for addressing all zones. Three LED indicators show the operational statuses of the console, such as evacuation, fault, and power. An in-built loudspeaker makes it possible to listen to all system generated messages and announcements. The integrated fire telephone handset finished in brushed stainless steel comprises a 12-key keypad, high-contrast display, and 8 LED status indicators. 2 TECHNOLOGY The analogue addressable fire alarm control panel displays the address, type, and status of each device on the loop. Each fire detection loop can accommodate up to 240 fire alarm devices with in-built isolators, and the loop length can extend up to 6 km depending on load and loop length calculations. Programming options allow a user to assign zones to fire detection and alarm devices on the loop and furthermore link them with actions such as fire or fault signals and voice messages to be initiated when the devices are in the alarm mode by means of advanced AND/OR logic operations. Various parameters of devices on the loop can be set and controlled from the control panel. Detectors can be programmed to operate with different sensitivity levels and sounders can be synchronised from the panel. The control panel also indicates the loop output and input voltages, loop loading, and signalling quality. The loop driver circuit on the base card is equipped with in-built short circuit isolators to ensure uninterrupted communication between the panel and first device on the loop. Each fire detection and alarm device on the loop is equipped with an in-built isolator to minimize loss of communication in case of short circuits. Hence there’s no need for additional isolators or base isolators. Alternatively, devices can be supplied without isolators. In such cases, isolators will have to be installed on the loop. The fire alarm control panel allows programming of complex ‘cause & effect’ functionalities to either a single output device or group of output devices (sounders, beacons, relays) to respond to a fire or alarm signal for input devices. Up to 200 output groups on a network of 1000 zones can be programmed from the control panel. Delays can be introduced to allow phased evacuation in a building. ATEÏS Variable Time Communication (VTC) Protocol enables secure data transmission over long distances. Advanced detection algorithms ensure thorough evaluation of the environments in which the detectors are placed, and thus, fire signals are activated only when smoke is actually present. The integrated paging microphone console on the fire alarm control panel is wired to the master audio distribution matrix or digital signal processor on the PAVA rack, enabling the operator to monitor all loudspeaker circuits, zones, and amplifiers for faults. In large networks with multiple PAVA racks, the paging microphone console on the 4000 INT allows selection of any loudspeaker zone for public addressing and isATEÏS Middle East FZCO. P.O. Box: 293640 Dubai United Arab Emirates Tel: +971 4 3262730 Fax: +971 4 3262731 Email: [email protected] http://www.ateis.ae VELOX 4000 INT SERIES suing voice instructions for evacuation. INSTALLATION & MOUNTING The touch screen paging microphone console can be programmed to enable quick access to various zones or groups of zones through customizable buttons on the touch pad. The buttons can be assigned to different zones or zone groups by naming them accordingly. Additionally, the buttons can perform additional functions such as volume control, priority settings, message activation, and so on. The fire telephone handset allows the operator to communicate with outstation handsets by dialling the number of the outstation handset. The name or number of the outstation handset is indicated on the backlit display. The fire telephone master handset on the 4000 INT series of fire alarm control panels is connected to an eightline exchange which links the outstation handsets with the master handset. An addressable telephone jack can be used to link the fire detection loop of the control panel and the fire telephone network via the 8 line exchange. Similar to all devices on a fire panel loop, the telephone jack is fully monitored from the control panel and a unique address is assigned to it. Installing the jack on the fire panel loop supports emergency voice communications via the fire telephone network by using a portable handset. Furthermore, security and ‘cause and effect’ features are significantly enhanced if the telephone jack is monitored on the fire panel loop. APPROVALS & COMPLIANCE WITH STANDARDS The VELOX 4000 INT range of integrated fire alarm control panel and PAVA systems has BSI Kitemark, TUV, and LPCB certifications, and it complies with the following British and European standards. BS EN 54-2:1998 (Fire detection and fire alarm systems. Control and indicating equipment) BS EN 54-4:1998 (Fire detection and fire alarm systems. Power supply equipment) BS EN 60849:1998 (Sound systems for emergency purposes) Membership No.472288644 ATEÏS Middle East FZCO. Loop driver cards must be installed in the fire alarm control panel to expand the number of loops. A base card in the control panel has slots (2 slots and 4 slots for 4200 INT and 4400 INT, respectively) allotted for installation of loop driver cards, which can easily be guided in place on the base card. Each loop starts and terminates on the base card of the control panel and it is wired to the pairs of loop out and loop in terminals. This loop configuration in which the wires return to the same control panel provides the highest redundancy for communication as per the NFPA Class A, Style 7 wiring. The in-built isolators ensure that under a single short circuit fault condition, all devices will continue to operate as normal. For additional functions, the control panels have provision for installing peripheral cards via an RS485 bus interface to expand the number of inputs and outputs as per increasing requirements for ‘cause & effect’ functions. A mimic panel can be mounted on the fire alarm control panel to provide a graphical representation of zones using LED indicators. The mimic panel layout with LED indicators is designed on the basis of a standard CAD drawing of a zone. Zonal LED indicators can be mounted on the panel to simultaneously display the status of all zones under fire conditions. The mimic panel and fire alarm control panel can be further customized for smoke control applications with additional LEDs and switches for manual control of doors, vents, lifts, etc., as required. The integrated paging microphone consoles can have either monochrome or colour touch screens. The devices have dedicated and secured audio and communication links. To increase the distance between the paging console and the PAVA rack, a local power supply is required. COMMISSIONING & TESTING The ‘Soft Addressing’ feature or ‘Auto Learn’ option on the panel when selected enables the control panel to automatically record the total number of addresses and devices on a loop. The panel notifies the user if it finds devices missing or replaced then registers the new status of the loop according to the options selected by the user. Soft Addressing allows automatic sequential addressing of devices (1–240) on the loop from the fire alarm control panel, simplifying the commissioning process. The last sequenced address should correspond to the total number of devices installed on the loop, as recorded when ‘Auto Learn’ is activated. P.O. Box: 293640 Dubai United Arab Emirates Tel: +971 4 3262730 Fax: +971 4 3262731 Email: [email protected] http://www.ateis.ae 3 VELOX 4000 INT SERIES To add a new device to the loop, the ‘Safe Addressing’ feature enables the user to set new addresses to devices by using the VPU100 hand-held programming unit. This allows the addressing to match site conditions or even allows the user to add more detectors to the loop at a later stage without the need to change or reassign addresses to all the devices. Each device on the loop or a fire zone can have a text description beside its name when displayed on the fire alarm control panel. This provides clear indication of the location and description of a zone or device in fire or fault conditions and enables commissioning, testing and maintenance engineers to track the source of a problem and take appropriate action. Individual detectors can be tested by selecting the address of the detector on the control panel and activating the ‘Test’ command. Alternatively, detectors can be tested physically on site by positioning a magnet on its base. The magnet test verifies the function of all electronic circuits of the detector and its communication with the control panel. The integrated paging microphone console is configured from the PAVA controller and matrix, which allows adjustment of the microphone sensitivity and speaker volume level. The input signal can be adjusted with a 3-band parametric equalizer. Priorities can be set for both the paging microphone console and the various messages supported by the console. Messages can be allocated in two categories–evacuation or normal. The message levels, priorities, equalization, and siren levels before activation of the message are set for optimum response. ARCHITECTURAL & ENGINEERING SPECIFICATIONS The VELOX 4000 INT range of integrated fire control and indicating panels shall have the BSI Kitemark certification and comply with the following British codes of practices for planning, design, installation, commissioning and maintenance of fire detection and fire alarm systems, voice alarm systems and emergency voice communication systems–BS 5839-1, BS 5839-8, and BS 5839-9, in addition to European Standards BS EN54-2, BS EN54-4, BS EN 60849. The fire alarm control panel (FACP) shall have the provision to expand number of loops from 2 to 8 on a single device. Each loop shall have the capacity to address 240 devices, depending on loop length and load calculations. The FACP shall have networking capabilities to allow up to 200 panels on a secure ring network with distance extendable up to 20km. Fiber-optic cabling allows significant extension in the communication distance within the network. 4 The control panel shall have provision for housing fan control switches and LEDs for integrated smoke control management. The 4000 INT range shall support mounting of a mimic panel on the main control panel to provide graphical indication of zones and devices. The 4000 INT range of fire alarm control panels shall provide fully integrated functionalities of fire alarm and detection, voice alarm, mass notification, emergency voice communication, background music and foreground music with professional audio features. The communication protocol for the fire alarm network shall be the ATEIS variable time communication (VTC) protocol, which allows extension of the loop length to 6km. Network cabling shall be an easy setup with two-core twisted pair cables and without requirement for shielded cables. This simplifies installation of the fire alarm network. The control panel shall support sophisticated programming logic functions to allow up to 1000 fire zones per network, along with duplication of zones. Advanced delay and logic (AND/OR/XOR) operations allow sophisticated cause & effect programming on the control panel. The control panel shall allow adjustment of detector sensitivity levels to respond with different setting for day and night. With a simple programming step, the control panel can provide instructions on the date/time to the detector head to reduce/increase the sensitivity or switch off or switch on the heat/photo sensor within the same head. This increases the response to real fires and reduces false alarms depending on the application and location of the detector. The control panel shall have provision for installing peripheral cards via an internal RS485 bus interface to expand the number of inputs and outputs with dedicated I/O cards that shall be housed inside the cabinet of the panel. The integrated paging microphone console and its components (microphone, power supply, touch screen, audio, and RS485 connections) shall be fully monitored for faults. The touch screen panel shall indicate all system faults. The paging microphone console shall be programmed either by using a PC or via the PAVA controller and digital signal processor. The console shall have password ATEÏS Middle East FZCO. P.O. Box: 293640 Dubai United Arab Emirates Tel: +971 4 3262730 Fax: +971 4 3262731 Email: [email protected] http://www.ateis.ae VELOX 4000 INT SERIES protection features for authorized access. All parameters required for monitoring and controlling audio distribution across the entire PAVA network on a site shall be programmed from the paging microphone console. The paging microphone console shall have an in-built loudspeaker for the operator to listen to all messages and announcements. The colour touch screen microphone console shall have three additional hardware keys for user-defined functions. panels shall be compatible with all the latest communication protocols employed for security and automation in buildings. In addition to TCP/IP, other open protocols such as BACnet, LON, Modbus, etc., shall be fully compatible for integration with building management systems. The FACP shall be compatible with digital signage devices such as LCD screens for display of evacuation messages and indications, maps of project sites and device locations, etc. The 4000 INT system shall support simultaneous routing of 48 audio channels on the network when integrated with a digital signal processor for commercial audio. The audio distribution network with digital signal processors shall have a loop architecture which provides full redundancy. The digital signal processors shall be connected on an Ethernet based network via fiber optic cables. The network shall support 24-bit audio at sampling rates of 48 and 96 KHz. The digital signal processors shall provide a vast array of signal processing tools (compressor-limiter, equalizer, matrixing and delay functions, automatic gain control, etc.) which can be programmed via a user-friendly graphical user interface as per requirements. The integrated fire telephone handset on the 4000 INT range of control panels shall provide emergency voice communications on the network by means of 32 line exchange units with 8 lines to link remote handsets and fire telephone jacks to the master handset on the FACP. The master fire telephone handset on the 4000 INT series of fire alarm control panels shall provide a secure communications link to outstation handsets and remote handsets via telephone jacks, in addition to disabled refuge points. The fire telephone network integrated with the voice evacuation system shall enable routing of emergency conversations to any desired zone and to record conversations in the MP3 format for future reference during accident investigations. The integrated fire telephone network shall have the provision for installing addressable telephone jacks on the fire detection and alarm loop and connected to the master handset via the line exchange unit. The telephone jack shall be addressed and fully monitored form the fire alarm control panel. The 4000 INT range of integrated fire alarm control ATEÏS Middle East FZCO. P.O. Box: 293640 Dubai United Arab Emirates Tel: +971 4 3262730 Fax: +971 4 3262731 Email: [email protected] http://www.ateis.ae 5 VELOX 4000 INT SERIES TECHNICAL SPECIFICATIONS 4400 4200 Dual Flash based Processors with Real Time Clock, ‘Trace’ diagnostics, ‘PuLsE’ communications & programmable languages Base Technology Display Backlit 240x64 Graphical LCD LED Indicators 3 Red (2 x Fire, 1 x Alarm), 1 Green (Power) & 12 Amber (Fault & System) Controls Alpha Numeric Keypad, Navigation Keys & System Keys for Reset, Mute, Silence/ Resound & Evacuate Protocols ATEÏS “ VTC ” Variable Time Communication Number of Fire Zones 1000 ‘Dynamix’ 1 – 4. Expandable via individual plug-in loop driver Number of Loops Devices per loop 240 Loop Current 500mA On Board Sounder circuits 4 x 1 Amp Programmable 2 x 1 Amp Programmable On Board Relays 2 x 1 Amp 30v AC/DC Programmable Auxiliary Supply 1 x 24v 500mA Open Collector / Logic Outputs Programmable Switch Inputs 8 x Programmable 8 Volt Free Digital Inputs On Board Power Supply Mains Supply Battery Capacity 5Amp High Efficiency Switched Mode 4 Amp High Efficiency Switched Mode 110 - 230 V AC (+10%, -15% tolerance) 50 / 60 Hz 1.7 Amp 110 - 230 V AC (+10%, -15% tolerance) 50 / 60 Hz 1.9 Amp 24v 18 Ah internal. 24v 48Ah external 2.2 Amp DDP monitored, temperature compensated integral charger Charger Current 2.0 Amp DDP monitored, temperature compensated integral charger Serial ports 1 RS232 Onboard for PC, Modem or External Printer Programming Via on-board Keypad or PC running Windows Tools Event Log 1000 Fire & Event + Diagnostic Networking Optional plug in Network card Printer (Option) Optional on-board or External Serial Printer Enclosure / Colour RAL 7016 / Anthracite Grey Cable Entry RAL 7024 / Graphite Grey 20mm Knock-outs. 18 x top, 9 x top rear and 2 x bottom Size H x W x D mm / Weight 6 1 – 2. Expandable via individual plug-in loop driver 950x 450 x 200 / 10.5Kg 475 x 450 x 115 / 10.5Kg 475 x 450 x 188 / 10.5Kg (/D Deeper Enclosure) Back Box Only (When Recessing) 475 x 450 x 100 Deeper Back Box Only (when Reccessing) 475 x 450 x 173 Metalwork Options Flushing Bezel, Ancillary Enclosure & Battery Box Metalwork Options BS EN54-2:1998, BS EN 54-4:1998, BS EN60849:1998 ATEÏS Middle East FZCO. P.O. Box: 293640 Dubai United Arab Emirates Tel: +971 4 3262730 Fax: +971 4 3262731 Email: [email protected] http://www.ateis.ae VELOX 4000 INT SERIES TECHNICAL SPECIFICATIONS PSSDT Specification Details Connections Connections: RJ45 Dimensions Console size: (L x W x D) 250 x 140 x 80 mm Flex length: 250 mm Weight: 1.5 kg Colour: RAL 9006 Front tilted at 30° Material: metal back, PVC top and sides Power supply Power supply: 24DC/450mA Fire Telephone System Specification Details Power Supply Source Voltage Current Processing Architecture Clock Memory Monitoring AVR RISK 16MHz 4K RAM 20K EEPROM 128K Flash 125mS Asynchronous Watchlog Checksum on EEPROM & Flash Network Cables Grade Cable (per leg) OR OR Distance (per leg) Monitoring Enhanced Cable (per leg) 1 off four Pair (eg Draka 91 -0245) 2 off four core 1 mm CSA Soft Skin 4 off 1 Pair MICC Twisted 500M Soft Skin types, 300 M MICC Data & Phantom Voltage Indication & Controls Fault LEDs change) Status LEDs LCD twenty-character Keyboard Navigation Standards Compliance EMC Product Family 230V AC + 20% 11mA 12V SLA 3.2AH 4 off yellow (General, Panel, Supply & Ex4 off green (healthy, AC, DC & Network) High Contrast Green/ Black LCD, four line 5 x 8 pixel format 12 Key Telephone Style 3 Keys (down/left, Accept, up/right) EN55103-1, EN55103-2 BS5839-Part 9, BS5588-Part As our policy is one of constant product improvement the right is therefore reserved to modify product specifications without prior notice Ref. 4400 INT&4200 INT/FP/R1/V1/060611 ATEÏS Middle East FZCO. P.O. Box: 293640 Dubai United Arab Emirates Tel: +971 4 3262730 Fax: +971 4 3262731 Email: [email protected] http://www.ateis.ae 7