Download Product Launch - STATES Products

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts

Islanding wikipedia , lookup

Dither wikipedia , lookup

Current source wikipedia , lookup

Ohm's law wikipedia , lookup

Variable-frequency drive wikipedia , lookup

History of electric power transmission wikipedia , lookup

Rectifier wikipedia , lookup

Electrical substation wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Buck converter wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Metadyne wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Opto-isolator wikipedia , lookup

Automatic test equipment wikipedia , lookup

Stray voltage wikipedia , lookup

Alternating current wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Mains electricity wikipedia , lookup

Portable appliance testing wikipedia , lookup

Transcript
NEW PRODUCT LAUNCH
Sales guide
Megger S1-554 and S1-1054
NEW High Noise Immunity
5 & 10 kV Insulation Resistance
Testers
Test performance without competition
Megger Limited
S1-554 and S1-1054
PWS / Oct 06
2
Table of Contents
PRODUCT FAMILY .......................................................................................... 3
THIS PRODUCT IS USED FOR?................................................................ 3
WHY? ..................................................................................................................... 3
THIS PRODUCT IS USED BY? ................................................................... 4
TECHNICAL OVERVIEW ............................................................................... 4
What is Interference (noise)? ............................................................................. 4
The solution?...................................................................................................... 5
How is it used? ................................................................................................... 5
FEATURES, BENEFITS AND BENEFITS ............................................... 5
KEY FEATURES, BENEFITS AND BENEFITS ..................................... 6
ORDERING INFORMATION ......................................................................... 7
PRODUCT SELECTION CHART ................................................................ 8
COMPETITOR ANALYSIS S1-554 and S1-1054 .................................. 8
Megger Limited
S1-554 and S1-1054
PWS / Oct 06
3
PRODUCT FAMILY
The new products are additions to the S1 family of insulation testers. Structured as
follows:
S1-552
S1-1052
S1-554
S1-1054
5kV, 5mA Diagnostic insulation tester with 2mA noise rejection
10kV, 5mA Diagnostic insulation tester with 2mA noise rejection
5kV, 5mA Diagnostic insulation tester with 4mA noise rejection
10kV, 5mA Diagnostic insulation tester with 4mA noise rejection
Where does the name come from?
S1 is derived from “Series 1”. The Series 1 instruments were for many years
considered “the definitive insulation tester” in the market place and well known for
their heavy-duty output and reliability. Hence we have used S1 prefix for the heavyduty versions.
The rest?
S1
-
5
5kV output
5
5mA test current
4
4mA Noise rejection
S1
-
10
10kV output
5
5mA test current
4
4mA Noise rejection
THIS PRODUCT IS USED FOR?
This product is used for diagnostic insulation testing with DC voltage, with the
additional benefit of being suitable for electrically noisy environments such as high
voltage switchyards. The aim is for the customer to be able to analyse the quality of
insulation within equipment such as line and substation transformers, circuit
breakers, switch panels, large motor/generator windings and HV cables etc. The high
5mA test current makes this product particularly suitable for testing high capacitive
loads such as long cables.
WHY?
Insulation is then monitored so that developing faults can be diagnosed and
corrective action taken before expensive failures occur. As part of maintenance
program diagnostic insulation testing can quite literally save many thousands times
the cost of the tester and labour in prevented breakdown costs.
However electrical interference experienced in many high voltage areas can result in
poor, unreliable or unstable readings making effective diagnostic testing of the
insulation impossible. In noisy 400kV plus switchyards interference currents up to
4mA are not uncommon. Currently only one competitor product quotes noise
rejection, and they claim 2mA rejection. The S1-554 and S1-1054 provides the
solution with a full 4mA of rejection.
The 10kV option (S1-1054) is suitable to test to IEEE standards for testing motors
rated greater than 12kV, with the additional benefit of future proofing the instrument
against advances in insulation technology.
Megger Limited
S1-554 and S1-1054
PWS / Oct 06
4
THIS PRODUCT IS USED BY?
•
•
•
•
•
•
•
•
•
•
•
Power Utilities
o Maintenance and commissioning departments
Cable Manufacturers
Electrical Contractors
o Contracted to Power Utilities
o Maintaining high voltage systems
Testing Companies
o Contracted to Power Utilities
o Maintaining high voltage systems
Electrical Maintenance Companies
o Contracted to Power Utilities
o Maintaining high voltage systems
Industrial/Manufacturing Plants
o Using and maintaining high voltage systems and rotating machinery
Process Control Plants
o Industrial manufacturing plant
University / Colleges
o Research applications
Large infrastructures
o Airports
o Transport
Electricians
Defence / Government
TECHNICAL OVERVIEW
In summary the new instruments are identical to the existing S1-552 and S1-1052,
but better in one key respect. Noise rejection. Both the MIT and existing S1-XX52
range can reject 2mA of interference current. The new instruments can reject 4mA .
What is Interference (noise)?
Interference is the electrical noise produced due to a variety of frequencies, which
can appear on the sample being tested. It is usually due to induced currents or
voltages from adjacent equipment and is very common in substations, particularly
high voltage substations where power frequencies predominate. This electrical noise
superimposes an AC signal on the DC test current and can cause considerable
variations in readings and may prevent the operator getting a reading at all if it is
beyond the capabilities of the instrument.
In high noise environments high interference currents, can render most insulation
testers useless.
In short when selecting an insulation tester the customer must be aware of its
capability to cancel out the effects of this AC noise and its suitability for the testing
environment. Further more not all noise is limited to power frequencies, hence our
advanced instruments utilise software filters to eliminate the effects of this noise.
Megger Limited
S1-554 and S1-1054
PWS / Oct 06
5
The solution?
The NEW S1-554 (5kV) and S1-1054 (10kV) are the latest heavy-duty insulation
testers from Megger with 5mA test current. However these instruments incorporate
the very latest in noise rejection technology to eliminate unwanted effects in these
high noise environments.
How is it used?
The instruments are equipped with the latest technology in both hardware and
firmware filtering. The default setting of the instrument is with the hardware filter
switched on and the firmware filter switched off.
The hardware filter removes faster variations due to the effects of noise and may be
switched off if desired to slightly speed up testing in quiet locations and when testing
high capacitance loads. This simply removes the impedance of the filter circuit.
The firmware filter averages out slow variations due to the effects of noise. The time
constant of the filtering is user selectable to 10, 30 or 100 seconds to suite. This can
be adjusted during the test to give the best result.
FEATURES, ADVANTAGES AND BENEFITS
This section is split into two parts; the second section over page lists the most
important key selling points.
Part 1.
F:
A:
B:
Battery or mains powered.
Can perform testing powered from the mains supply when battery is
flat.
Saves time waiting for battery to charge.
F:
A:
B:
Rugged case
Less likely to damage in harsh environments
Increases reliability and time lost due to unexpected repairs
F
A:
B:
Lid mounted test lead bag
Leads kept and protected with instrument at all times.
Less likely to loose test leads keeping the instrument ready to test.
Megger Limited
S1-554 and S1-1054
PWS / Oct 06
6
Part 2.
KEY FEATURES, ADVANTAGES AND BENEFITS
S1-554 and S1-1054
Key Feature: 4mA Noise rejection
Advantage: Able to take accurate readings in electrically noise environment.
Benefit:
Will not be affected by adjacent powered up equipment.
Key Feature: High Resistance measurement range
Advantage: Takes readings at high insulation values instead of infinity reading
Benefit:
Can trend readings for effective insulation evaluation, indicating
potential failures earlier. Cannot trend infinity readings.
Key feature:
Advantage:
Benefit:
High accuracy readings
Readings are reliable and repeatable, allows accurate trending of
results over time
Accurate diagnosis of insulation ensures correct action taken to avoid
breakdown of equipment.
Key Feature: High Output test current.
Advantage: Less time to charge capacitance, and applies higher voltage to lower
insulation levels
Benefit:
Saves testing time, and shows true condition of lower value insulation.
S1-1054 only:
Key Feature: 10kV insulation test voltage
Advantage: Higher test voltage produces higher current through insulation
Benefit:
The ability to make higher insulation reading (35TOhm), meets IEEE
requirements.
Megger Limited
S1-554 and S1-1054
PWS / Oct 06
7
ORDERING INFORMATION
S1-554 (5kV)
Instrument variant part number:
Language Main User English
Guide and French
Quick Start German
on CD
Spanish
Italian
Portuguese
Dutch
Finnish
Swedish
Chinese
Russian
Quick Start English
Label in lid French
German
Spanish
Italian
Portuguese
Dutch
Finnish
Swedish
Chinese
Russian
Supply
Discount
Mains Plug UK (3A fuse)
Supplied
EU Schuko
US
Code
T
S1-1054 (10kV)
S1-554-EN S1-554-EU S1-554-US S1-1054-EN S1-1054-EU S1-1054-US
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
New 5 and 10kV Range - Specification chart
70
60
50
Auto Diagnostic tests
40
Noise Immunity (mA)
Test Current (mA)
30
Test Voltage (kV)
20
Max Range (Tohm)
10
0
MIT520
Megger Limited
S1-554 and S1-1054
S1-552
✔
✔
✔
✔
Prices are provided on a separate price list.
The chart below is just an indication of how specifications compare across the
complete new range.
MIT510
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
S1-554 MIT1020 S1-1052 S1-1054
PWS / Oct 06
✔
✔
8
PRODUCT SELECTION CHART
Covering all Megger New MIT and S1 range of 5 – 10kV insulation testers
Tick Chart
Feature
Display
Sub-feature
Analogue
Digital
Power Supply Line Power
Rechargeable Batteries
Test Voltage
10kV
5kV
2.5kV
1kV
500V
250V
User selectable
Measurements Maximum Reading
Voltage
Capacitance
Leakage Current
Automatic
Insulation Resistance
Test Types
Polarisation Index
Step Voltage
Dielectric Discharge
Dielectric Absorption Ratio
Other Features Timer Control
Timer Display
5mA Test Current
3mA Test Current
2mA rms at 200V and
above interference rejection
4mA rms at 200V and
above interference rejection
2% error guarding 500kΩ
leakage with 100mΩ load
Data Storage
USB Output
RS232 Output
Free Calibration Cert
IP65 rating
Alarm Limit Mode
Megger
MIT510 MIT520 MIT1020 S1-552 S1-554 S1-1052 S1-1054
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
15TΩ 15TΩ
35TΩ 15TΩ 15TΩ 35TΩ
35TΩ
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
A sales guide covering this complete range will be published shortly
COMPETITOR ANALYSIS S1-554 and S1-1054
Separate full competitor analysis tick charts are available separately
However
Key feature competitor comparison summary:

High noise immunity (4mA)
– NO COMPETITION

High Output Test Current (5mA)
– NO COMPETITION

High Resistance Measurement range
– NO COMPETITION
Megger Limited
S1-554 and S1-1054