* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Low Voltage Surge Protection
Electric power system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power engineering wikipedia , lookup
Power over Ethernet wikipedia , lookup
History of electric power transmission wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical substation wikipedia , lookup
Stray voltage wikipedia , lookup
Buck converter wikipedia , lookup
Distribution management system wikipedia , lookup
Protective relay wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Earthing system wikipedia , lookup
National Electrical Code wikipedia , lookup
Mains electricity wikipedia , lookup
SPD Product Catalogue 2010 Low Voltage Surge Protection Australia & New Zealand Low Voltage Surge Protection Understanding Surge Protection & it’s Applications Why do I need surge protection? If a surge is of sufficient energy level then it can damage or destroy electrical equipment or even the electrical infrastructure itself. Direct & indirect costs to a business can be very expensive. A surge protection device is in real terms very inexpensive & when correctly selected & installed can prevent damage occurring. What is a surge? A surge is a random, short burst of excess electrical energy to a system. It is typically measured in micro & milli-seconds. Also referred to as a transient, impulse or spike, these electrical disturbances can damage or even destroy sensitive microprocessor-based equipment. Surge protection devices are designed to reduce the amount of harmful energy that flows into a system. Where do they come from? 80% of transients are generated from internal sources such as load switching, motors starting up or even turning on air conditioning systems. The other 20% of transients are typically generated from external sources such as lightning strikes & power company grid switching. Like it or not, most electrical systems are subjected to some level of transients. What is SPD? Referred to as Surge Protection Device (SPD). They are defined as: “A device designed to protect electrical equipment from power surges & voltage spikes.” 2 Eaton Surge Protection Are there any standards that apply? For many years now there have been internationally recognised standards for surge & lightning risk assessment & protection. Research & standards committees publish many standards relating to surge risk & immunity. These standards however differ from one geography to another. Of importance is that there are two basic low voltage standards in the world. In the U.S. it is 120Vac, 60Hz. ( half the voltage & twice the current ). In Europe, Australasia & parts of Asia it is 220-240Vac, 50Hz. ( twice the voltage, half the current ). It is important to recognise that there are differing methodologies & compliance regulations for both systems. There are similarities between the US & European standards, but at key points the standards become mutually exclusive. So what standards do I use? Our electrical infrastructure in Australia has been developed based on European standards. It is therefore appropriate to use the European standards as our guide. There are many surge standards that can be followed. Most AS/ NZS standards have great similarity to the IEC standards. There are several levels of standards that can apply to any solution. It is important to understand that there is a hierarchy of standards. At the highest level there are the Low Voltage Framework Directives. Below this are Lightning & Surge Risk Assessment standards. Below this again are TVSS & SPD equipment standards & within these are test & waveform standards. All these standards need to be used in conjunction with local electrical switchboard & wiring codes. Some of the standards that apply & are often mentioned are: • IEC LV Framework • ANSI / IEEE C62.41 Waveform, test & current standards & limits. • AS/NZS1768 Lightning & Surge Protection - Risk assessment. • IEC61643, UL1449 Equipment standards • IEC 61006-1,2,3,4 EMI/RFI generation & immunity And that’s not all of them. There’s a lot to understand. Some standards overlap, it is easy to confuse them & apply an in appropriate standard. Understanding the standards is key to success. System design System design is not as difficult as it seems. As long as the basic principles of applicable standards are applied then the job at hand is to: 1. Divert the incoming excess energy at the point-of-entry. (Stop it BEFORE it gets into the system. It’s cheaper & easier to deal with it at the point of entry). 2. Control current flow to the next zone. Do it again! 1. Divert excess residual energy. 2. Control current flow to the next zone. It’s that simple. However, understanding what the correct risk rating is, what needs to be protected vs. what does not, what product to use & how to correctly install it for full performance benefit can be difficult. By following the next few pages we make it easier to identify risk, classify protection zones & identify suitable products. What are the rules for installation? One of the key issues often overlooked is the correct placement & installation practice that should be applied. Each site is different. There is no single definitive design that can be applied across the board for all surge protection situations. It very much depends on the specific site infrastructure. There are however, some basic rules that should be practiced to ensure that a solution will work effectively. Whilst not comprehensive, the following are guidelines for successful installation. Physical & electrical location. Location, Location, Location. It’s a familiar line but very true. Getting the location of an SPD right is paramount to success. It should be located as close as possible to Main Switch or metering point – within Main SWB if possible. The earthing point for the SPD (for Main SWBs) must be located within a short distance. The main earthing point is where you want the excess energy to end up being safely dissipated. Safety disconnectors. It is preferred to use HRC Gg/Gl fuses, not CBs. HRC fuses perform better than CB’s which are not designed for surge waveforms & fast rising transients. For medium & high-current services (250-3000A), use the maximum fuse as recommended by the manufacturer. For low-current services (<250A), the fuse rating will limit surge capacity. For very low-current services (<80A), it may be necessary to rely on line fuses. Cable length & type. Cable length (inductance) is the biggest issue. Multiple, small cables are better than one large cable. Where permitted, busbars are much preferred as they provide the lowest impedance return path for the surge energy. Wherever possible, keep the total connection length below 0.5m on any cable & always tie cables tightly together. Try to keep surge voltage drop to <1kV/cable. Don’t loop extra cable! It only adds more inductance & reduces the surge withstand capacity of the circuit. EVERY millimetre counts. Earthing. The site earth must be as good as possible. This is where the excess energy will end up. Again, if possible, busbars should be used for runs <3m. Use a ‘star’ (or ‘single-point’) earthing system in all cases. Do not daisy-chain earth in a surge circuit. Daisy chaining earth simply allows the surge return path to be connected to the load with the potential to damage the load instead of being diverted to the main earth & safely dissipated AWAY FROM THE LOAD. By following the above guidelines you will maximise your investment in a surge product. All products in this catalogue have been designed & tested to international standards by Eaton’s SPD Engineering Division in laboratories in Australia & China. For more information including engineering support, white papers, specification advice & product support, contact your Eaton representative. Contents Selecting Surge Protection Equipment 4 Class II/Cat C & B - Secondary Protection MSFI – 1 & 3 Phase 40-63A Surge Filter 25 Class I/Cat D & E - Direct Strike Protection DSFI – 1 Phase High Performance Surge Filter 27 SPDSG50-300 – Spark Gap Diverter 7 CSFI – Din Rail Compact Surge Filter 29 SPDSG50-255 – GDT Diverter 7 SPD50NGI – Neutral-Earth Surge Protector 31 Class II/Cat D & C - Point of Entry Protection PPFi – 3 Phase Premium Power Filter 9 Class III/Cat A Point of Use Protection MSDI – 3 Phase Surge Diverter 13 POD – Surge Powerboard 34 SPDI – Din Rail Mounted Surge Diverters 15 SSFI – Portable Surge Filter 36 SPDV60 & SPDT60 – Din Surge Diverters 18 SPD DM Series – 5-48V Low Voltage Diverters 38 Quickmov – Integrated Surge Protection 20 EMTJ & ERAK – Dataline Protectors 39 PVD40 Series – Photvoltaic Surge Diverters 22 SF8RM – Single Phase Rack Surge Filter 40 Quick Product Selection Guide 41 UPS & Surge Filter Selection Guide 42 Eaton Surge Protection 3 Selecting Surge Protection Equipment Understanding Surge Protection Categories to neutral or earth, protecting switchboards, contactors, transformers & motors from burnout due to extreme voltages. A properly installed surge diverter can limit surges to below 2000V. Protection Categories Surge Protection Zones (ANSI/IEEE C62.41) Cat E Cat D Cat C Cat B 6kV/70kA 6kV/30kA 6kV/15kA 6kV/3kA Cat A 6kV/200A TELECOM TOWER OUT BUILDING SERVICE ENTRANCE RESIDENTIAL BUILDING Eaton manufactures a complete range of power protection components. These components fall into a number of categories, depending upon where they are utilised in an electrical installation. The 3 main categories are, according to ANSI/IEEE C62.41 & AS/NZS1768-2007: Category A (6kV/200A): Long final sub circuits & power outlets Category B (6kV/3kA): Major sub mains & short final sub circuits If the main load in an installation is critical of high voltages (computers, communications systems, test equipment etc.), or generates electrical noise (variable speed motor drives, high-frequency welders etc.), a Surge/Power Filter (PPFI) should be used. In an PPFI, surge diverters are utilised in conjunction with low-pass filtering to reduce the surge voltage & remove noise. In normal operation, an PPFI can be expected to reduce surge potentials to less than 1000V whilst providing up to 70dB of noise attenuation. Method Firstly determine whether or not you require filtering or just surge diversion. If selecting a surge diverter, select a device appropriate for the protection category. The MSDI & SPDI are suitable for category C & B locations. Quickmov surge diverters can also be used in these locations for protection of Quicklag & DIN panelboards. If the site requires filtering at the point of entry, select an PPFI with the appropriate current rating for the load, then select the model appropriate for the protection category. For DC solar panel arrays with Grid Interactive inverters it is recommended that Cat C / Class II, DC type SPD’s are used. For this situation the PVD40 series Photo Voltaic Diverters in 500, 600 and 1000vdc versions be used. Category C (6kV/15kA): Point of entry In addition to these categories, there are 2 more categories which simply extend the Category C rating: Category D (6kV/30kA): Point of entry, high exposure Category E (6kV/70kA): Point of entry, very high exposure & critical load Equipment listed in this catalogue is referenced by category to make the selection of correct components easier. Selecting Surge Protection Equipment for Commercial & Industrial Applications High risk direct strike or point of entry. Class I/Cat D & E For very high risk installations it is recommended that Class I type SPD’s are used. Such devices are commonly referred to as “Spark gap arresters “. For this situation the SPDSG50-300 should be used for L-N and L-E modes and the SPDSG50-255NPE should be used for N-E mode. Point of Entry – Class II/Category C Basically, all installations should at least be protected at the point of entry. The starting point for protection is the surge diverter. Surge diverters effectively clamp the incoming lines 4 Eaton Surge Protection Minor sub mains & short final sub circuits – Class II/Category B Once past the main board, most protection involves both surge diversion & filtering. Non-critical loads such as lighting & general-purpose power circuits do not necessarily require protection. Method For large 3-phase loads such as mainframe computers or computer-controlled machinery, select an PPFI appropriate for the load. In this case the protection level required is usually taken as ‘one step’ below the protection level applied to the point of entry. For single-phase loads up to 63A, the DSFI & MSFI filter ranges are suitable (for current < 25A, the CSFI filter also provides installation compatibility with modular switchboards). Generally, filters should be mounted as close as possible to the equipment being protected. Long Final Sub circuits & Power Outlets - Class III/ Category A When protecting final sub circuits & power points there are 2 options. Either fit hard-wired filters to the circuit or use plug-in filters on the equipment to be protected. This choice will be determined by the load (plug-in filters are only rated up to 10A), & whether or not there is space for a plug-in filter adjacent to the equipment. With large computer networks, many administrators prefer not to use plug-in filters as they can be accidentally unplugged by the operator’s foot, causing network problems. For small servers however, a plug-in filter provides extra protection at the computer for ‘insurance’. Method Firstly select whether a hard-wired or plug-in filter is to be used. If selecting a hard-wired filter, the DSFI range is suitable for currents up to 32A (for currents < 25A, the CSFI filter also provides installation compatibility with modular switchboards). For plug-in filters, the SSFI series provides high levels of protection with good filtering. If the site requires filtering at the point of entry, select a DSFI filter with the appropriate current rating for the load. The DSFI filter is rated at 5-32A (for current < 25A, the CSFI filter also provides installation compatibility with modular switchboards). Final Sub circuits & Power Outlets – Class III/Cat A When protecting final sub circuits & power points there are 2 options. Either fit hard-wired filters to the circuit or use plug-in filters on the equipment to be protected. This choice will be determined by the load (plug-in filters are only rated up to 10A), & whether or not there is space for a plug-in filter adjacent to the equipment. Generally, a plug-in filter, used in conjunction with protection at the switchboard, gives the best protection. Method Firstly select whether a hard-wired or plug-in filter is to be used. If selecting a hard-wired filter, the DSFI is suitable for currents from 5 to 32A (for currents < 25A, the CSFI filter also provides installation compatibility with modular switchboards). Selecting Surge Protection Equipment for Domestic & Home-office Applications For plug-in filters, the SSFI & POD provides high levels of protection with good filtering. The POD also provides protection for ancillary devices such as phone/fax, network & coaxial cables - ideal for protecting video TV systems in domestic applications. Point of Entry – Class II/Cat C, B As with commercial & industrial applications, all installations should at least be protected at the point of entry. Again, this usually involves the use of surge diverters. Surge diverters effectively clamp the incoming lines to neutral or earth, protecting the switchboard & wiring from damage due to extreme voltages. Note: cable systems are electrically referred to mains neutral which only increases the potential of damage from electrical faults. If high levels of filtering are required such as for home automation or high-end audio visual, or other noise-critical equipment, the sub circuits supplying these systems should be protected at the switchboard by a high level device such as the CSFI. Surge diverters are a ‘must’ if the building is located in an exposed position or fed by long aerial cables, as in rural installations. If the building is part of a medium or high-density development & is fed by an underground cable, the risk of highenergy surges is quite low. In these cases, a surge diverter may not be necessary. In most domestic buildings, the main switchboard is the only switchboard & therefore, if it is desired to provide filtered power for critical applications such as computers, office equipment or entertainment systems, this should be done on the main switchboard. Few domestic applications use 3-phase power & those that do usually only use it for heating or airconditioning. For this reason, only the phase supplying power to critical equipment is actually filtered. The remaining phases are simply fitted with shunt diverters. Method Firstly determine whether or not you require filtering or just surge diversion. If selecting a shunt diverter, select a device appropriate for the installation. The SPD3NI, SPD3GI, SPDV60 & SPDT60 are suitable for single & multi-phase installations whilst the SPD120I is ideal for very exposed sites (on hilltops or with long aerial cables). Selecting Surge Protection for Dataline Applications For IT & telecommunication applications, dataline network protectors provide further protection against transients which can enter the electrical system through “back-doors”. The EMTJ & ERAK series offer transient protection for single port or multi-port configuration on CAT5 & CAT6 networks. The SF8RM is designed for surge protection in data rack cabinets where space is typically limited. For twisted pair coms and signalling data line it is recommended that Cat A / Class III type SPD’s are used. For this situation the SPD-DM series diverters in 5, 12, 24 or 48vdc versions be used. Eaton Surge Protection 5 Direct Strike Protection Class I/Category D & E (6kV/30kA) 6 Eaton Surge Protection Eaton® SPDSG Series Class I/Cat D & E Spark Gap & GDT Diverter multiple gap element design to ensure accurate triggering & with no follow current. There are 2 models to choose from. The SPDSG50-300 is suitable for connection across L-N or L-E. The SPDSG50-255NPE is suitable for connection in common mode across N – E. Each have been tested to the stringent requirements of 10/350us waveform standard , commonly known as I imp, & exhibit exceptionally low let through voltage of less than 2.5kV at 50kA. Specifications • • • • Shunt Surge Diverter 3 Phase, 100-400A, 80-240kA The new SPDSG series diverters are designed as IEC 61643-1, Class I, direct strike, surge diverters to protect high risk installations. Typically known as spark gap devices, these diverters use the latest technology 1 mode protection. N-E, L-E or L-N 50kA surge suppression rating Compact modular solution 2 unit DIN43880 case, 36mm DIN-rail mount Applications • Direct strike point of entry locations. Key Features: Technical Specifications SPDSG50-300 SPDSG50-255NPE Technology Encapsulated Spark Gap Encapsulated Gas Arrester Method of mounting 35mm Din rail 35mm Din rail Input voltage (Un) 230vac nominal 230vac nominal Max Continuous Voltage (Mcov) 300vac 255vac Test classification IEC Class I Class I Maximum rated surge current – (I imp) 10/350us 50kA 50kA Max rated surge current – (Imax) 8/20us 140kA 140kA Residual voltage (Vpl) <2.5KV <2.5KV Leakage current None None Response time <100ns <100ns External disconnector max 160A gL None Terminations 35mm multi-strand 35mm multi-strand Insulation resistance > 103 M Ohm > 103 M Ohm Enclosure material Thermo plastic. UL94-V0 Thermo plastic. UL94-V0 Enclosure rating IP20 IP20 Applicable standards. IEC61643-1:2001 IEC61643-1:2001 Dimensions 35mm (W) x 100mm (H) x 77mm (D) 35mm (W) x 100mm (H) x 77mm (D) Weight 200 grams 200 grams Environment -40c to +80c -40c to +80c Warranty 5 years 5 years Note: Specifications are subject to change without notice. Eaton Surge Protection 7 Point of Entry Protection Class II/Category C (6kV/15kA) 8 Eaton Surge Protection Eaton® PPFi Class II/Cat C & D 3 Phase Premium Power Filter The PPFI is designed to provide point-of-entry (Category C) & sub-circuit protection (Category B) against power surges caused by external sources such as lightning strikes & substation switching as well as providing a measure of protection from surge events generated on the secondary side of the filter. An ideal device for all Category locations. Series Power & Noise Filter with Shunt Surge Diverter 3 Phase, 100-400A, 80-240kA Applications: • • • • • • All Power Circuits including "Point-of-Entry" Telecommunications Systems & Rectifiers Process & Control Systems & UPS Systems Computer Systems & Medical Systems AV circuits for clubs & hotels All sensitive Electronic Equipment The PPFI is a 3-stage protection system utilising primary & secondary MOV protection in conjunction with a Low-Q LC filter. The unit provides filtering of the line harmonics, noise & RF transmitters with a cut-off frequency of <10kHz & a minimum attenuation of 70dB above 1MHz. Special care has been taken in the design of the filter to minimise ringing caused by light loads, surge diverter operation & inductive load backEMF. All models in the PPFI Series are fully enclosed in wall mounting IP24 steel enclosures. A graphical mimic display provides at-a-glance indication of the status of the PPFI with indicators showing correct functions in green & faults in red. The alarm function provides a summary alarm output for protection failure & power failure. Key Features: • • • • • • • • • • • Surge suppression & filtering in a single package Standard Current ratings from 100A to 400A 1 mode, Multi-Element Series Filter 2 mode, 3 stage Surge Diverter Surge suppression ratings from 80kA to 240kA Provides extensive high frequency & RF filtering Incorporates a EN certified EMI/RFI filter Panel-mounted mimic display Protection Fail Alarm Relay Enclosed in IP24 painted steel cabinet 5 Year Warranty Options: • Custom configurations •Isolation switches & circuit breakers • Custom cabinets • Chassis Mount versions Eaton Surge Protection 9 Eaton® PPFI Specifications Technical Specifications PPFXXX3CEi Input voltage 380 - 440VAC 3 Phase PPFXXX3DEi PPFXXX3EEi Maximum continuous voltage – MCOV 300VAC L-N Temporary overvoltage - TOV 320VAC, 15 mins Service type TT, TN, TN C-S or any 3-phase system with a grounded neutral. This unit must not be connected to an ungrounded system Test classification Class II Energy Absorption rating - per mode (Joules) Primary protection L-N: Secondary protection L-N: Common mode protection N-E: Aggregate rating: 1,200J/ph, 3,600J total. 600J/ph, 1,600J total. 2,130J. 7,530J. Current rating – continuous (standard models) 100A, 160A, 200A, 300A, 400A Recommended maximum over current protection 100A, 160A, 200A, 300A, 400A Residual current <1 mA Short circuit withstand (1 sec) 29kA Protection modes 1,800J/ph, 5400J total. 600J/ph, 1800J total. 710J. 7,910J. 3,600J/ph, 10,8000J total. 600J/ph, 1,800J total. 710J. 13,310J. Line-Neutral, Neutral-Earth Line-Neutral, Neutral-Earth Line-Neutral, Neutral-Earth In 8/20us (Line-Neutral) Nominal Surge Life 30kA x 20 hits/ph 45kA x 20 hits/ph 90kA x 20 hits/ph In 8/20us (Neutral-Earth) Nominal Surge Life 45kA x 20 hits 45kA x 20 hits 45kA x 20 hits Ismax 8/20us (Line-Neutral) Max surge level 80kA 120kA 240kA Ismax 8/20us (Neutral-Earth) Max surge level 120kA 40kA 40kA Filter attenuation 70dB nominal above 1MHz Initial clamp voltage (Line-Neutral) 560V (350Vac RMS) Initial clamp voltage (Line-Earth) 1240V (700Vac RMS) Initial clamp voltage (Neutral-Earth) 680V (420Vac RMS) Residual voltage (Vpl) Line-Neutral <900Vac (3kA, 8/20uS) IEC61643.1 Residual voltage (Vpl) Line-Earth <1100Vac (3kA, 8/20uS) IEC61643.1 Residual voltage (Vpl) Neutral-Earth <1000Vac (3kA, 8/20uS) IEC61643.1 Internal protection (fusing) All surge diverter connections are fused via HRC fuses to IEC269-2-1 Terminations Bolted lug. 8mm bolts for phase & neutral connections. 8mm PE (earth) stud provided on geartray. Alarms/indicators Mimic panel display via LED (2 colour), OK - Green; Protection Fault - Red. Dry contact alarm relay output – 250Vac/32Vdc, 10A, 4kV isolation, Alarm under-voltage cutoff 180Vac. Enclosure rating IP24 Design standards: IEC61643-1, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B,C,D AS1768-2007 Cat B,C,D,E AS3000, AS3100, CE mark Dimensions 600 x 200 x 800 mm (W x D x H) = 100A to 200A 800 x 400 x 1000 mm (W x D x H) = 300A & 400A Weight 100A & 160A = 50 kg, 200A = 60 kg, 300A & 400A = 75 kg Environment -10 to 65°C, 10 to 90%RH (non-condensing) Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. 10 Eaton Surge Protection ® Eaton ®PPFI Eaton PPFI Block Diagram & Mimic Display 1 Mode Multi-Element Series Filter 2 Mode 2 Stage Surge Diverter Surge Category The PPFI is suitable for use in all category locations: Primary MOV Protection Series Blocking Inductor Secondary MOV Protection High Frequency Capacitor Normal Mode Class II/Cat D (6kV/30KA) Point of Entry, High Exposure High Frequency Capacitor Normal Mode Power Input Power Output UL1283 EMF/RFI Filter Block Common Mode Common Mode Class II/Cat C (6kV/15kA) Point of Entry/ Service Entrance SPFXXX3CEi Block Diagram 1 Mode Multi-Element Series Filter 2 Mode 2 Stage Surge Diverter Class II/Cat B (Special Applications) Primary MOV Protection (6kV/3kA) Major sub mains & short final sub circuits High Frequency Capacitor Series Blocking Inductor Normal Mode High Frequency Capacitor Secondary MOV Protection Normal Mode Power Input Power Output UL1283 EMF/RFI Filter Block Common Mode SPFXXX3DEi & SPFXXX3EEi Block Diagram Eaton Surge Protection 11 C M Y CM MY CY K CMY Eaton® PPFI Connection & Line Diagram F i S urge F ilter nec tion Diagram 1003C E i, S P F 1003DE i, S P F 1003E E i, 50C E i, S P F 150DE i, S P F 150E E i, 00C E i, S P F 200DE i, S P F 200E E i, 250C E i, S P F 250DE i, S P F 250E E i Min dis tance to ceiling 300mm OUT P UT/LOAD L1 ument is to be us ed in c onjunc tion with L2 L3 N LOAD S urge F ilter Ins tallation G uide (T vs s Doc #510063) Earth eutral connections via 8mm bolts. n via M8 s tud, lower right of enclos ure. g for connection points. parate earth cable, even if the unit is bolted to L1 output cables phys ically separated at all times. dis tance 500mm. preferred to MC B s for connection to main S W B . ns tallation guide for details. ted within 3m (cable length) of the main system al link for point-of-entry application. G reater protection. proper operation of this S P F it is essential that ys ically s hort earth connection be made to the nt. W ith reference to local wiring standards, us ually s ized agains t a thermal rating, xpected fault currents , (5,000 to 25,000 amps). an S P F however, the installer must be aware nts can exceed 50,000 amps, and therefore re generally required to limit voltage drops ditions . T o achieve these requirements, the s hould be s elected to be equal to, or greater incoming cable into the S P F . T his ensures that n the earth cable are minimis ed. power-carrying conductors s hall be s ized a lly-applicable s tandards. It is recommended g neutral conductor be sized the same as (or phas e conducts as it is the primary return for es. L2 L3 N E INP UT/S UP P LY Earth Stud On G ear T ray 8mm Min distance to floor 600mm C M Y CM MY CY K CMY MAIN E AR T HING POINT (S W B ) MAIN S WB Important: Before installing the device, please read & follow the installation & operation instructions. 2 1 D 4 3 3/2/2005 550193 Differential protection and filtering. One phase shown, all phases identical LC LINE IN LINE OUT FILTER BLOCK FPRI D S P F i S eries 3/2/2005 FSEC C C L-N protection L-N protection NEUTRAL OUT NEUTRAL IN N-E protection NO B DIN-ADD SPF Display Driver Display PCB B COM ALARM OUT NC EARTH STUD Common-mode protection. FROM OTHER PHASES Title A Size A4 12 Eaton Surge Protection Date: File: 1 2 3 A SPF FILTER LINE DIAGRAM Number Revision 550246 7-Aug-2006 Shee1 t of1 JDP C:\tvss engineering\Product_engineering\current\MSF\MSF.ddb Drawn By: 4 0 Eaton® MSDI Class I & II/Cat D & C Three Phase Surge Diverter The MSDI surge diverter is designed to provide point-of-entry protection against power surges caused by external sources such as lightning strikes & substation switching. Common-mode protection is available for sites remote from the M.E.N. point including industrial sites & rooftops in multi-storey buildings. An ideal device for all Category locations. The MSDI surge diverters utilise MOV protection for both differential & common-mode protection. Multiple MOV devices are used in parallel for primary circuit redundancy. The status of protective devices is continuously monitored & displayed using LED bar-graph indicators. All MOV devices are thermally fused & isolated by ceramic fuses. Shunt Surge Diverter, 3 Phase 200kA MSDI unit is provided with an alarm relay. The alarm function provides a summary alarm output for protection degradation as well as power failure. The alarm may be configured to indicate either partial or total protection failure. The level of protection remaining is indicated by LED bar-graph indicators on the front panel. A summary alarm relay contacts provide remote signalling to remote equipment. Typical applications: • • • • • • All Power Circuits including "Point-of-Entry" Telecommunications Systems & Rectifiers Process & Control Systems & UPS Systems Computer & Medical Systems Multi-storey buildings All sensitive Electronic Equipment Key Features: • • • • • • 3 Mode, 2 Stage Surge Diverter Surge suppression rating of 200kA Enclosed in IP24 cabinet LED Bargraph display on each phase Protection Fail Alarm Relay 5 Year Warranty Surge Category 3 Mode 2 Stage Surge Diverter The MSDI is suitable for use in category locations: Primary MOV Protection Class II/Cat D (6kV/30KA) Point of Entry, High Exposure Class II/Cat C Secondary MOV Protection Normal Mode Common Mode Power Input Power Output Common Mode (6kV/15kA) Point of Entry/ Service Entrance MSDi Block Diagram (Only 1 phase shown, all phases are identical) Eaton Surge Protection 13 Eaton®® MSDI Eaton MSDI Specifications Technical Specifications MSD200CM60i Input voltage 200 - 250VAC (380 - 440VAC 3 Phase) Maximum continuous voltage (MCOV) 320VAC Temporary overvoltage - TOV 350VAC, 15 mins Service type TT, TN, TN C-S or any 3-phase system with a grounded neutral Energy Absorption rating - per mode (Joules) Primary Protection L-N = 3,000J/ph, 9,000J total Common mode protection L-E = 710J/ph, 2,130J total Common mode protection N-E = 2,130J total Aggregate rating 13,260J Recommended max. overcurrent protection 125A GL HRC fuse Protection modes Line-Neutral, Line-Earth, Neutral-Earth In 8/20us (Line-Neutral) Nom. surge life 75kA per phase x 20 times In 8/20us (Line-Earth) Nom. surge life 15kA per phase x 20 times In 8/20us (Neutral-Earth) Nom. surge life 45kA x 20 times Ismax 8/20us (Line-Neutral) Max. surge life 200kA Ismax 8/20us (Line-Earth) Max. surge life 40kA Ismax 8/20us (Neutral-Earth) Max. surge life 120kA Initial clamp voltage (Line-Neutral) 560V (350Vac RMS) Initial clamp voltage (Line-Earth) 680V (420Vac RMS) Initial clamp voltage (Neutral-Earth) 680V (420Vac RMS) Internal protection (fusing) All surge diverter connections are fused via HRC fuses to IEC269-2-1 Alarms/indicators Bargraph display for protection remaining, dry contact alarm relay output – 250Vac/32Vdc, 10A, 4kV isolation, Alarm under-voltage cutoff 180Vac. Enclosure rating IP24 Design Standards: IEC61643-1, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B,C,D,E AS1768-2007 Cat B,C,D,E AS3000, AS3100, CE mark Dimensions & Weight 370 x 160 x 560 mm (W x D x H), 14kg Environment -10 to 65°C, 10 to 90%RH (non-condensing) Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. C M Y CM 2 4 3 D Differential protection. One phase shown, all phases identical LINE t is to be us ed in c onjunc tion with T O LOADS FPRI C t cables phys ically s eparated at all times. nce 500mm. red to MC B s for connection to main S W B . ation guide for details . within 3m (cable length) of the main s ystem k for point-of-entry application. G reater ction. per operation of this MS D it is es s ential that ly s hort earth connection be made to the ith reference to local wiring standards, ally s ized agains t a thermal rating, ted fault currents , (5,000 to 25,000 amps). S D however, the ins taller mus t be aware an exceed 50,000 amps, and therefore nerally required to limit voltage drops ns . T o achieve these requirements, the ld be s elected to be equal to, or greater ming cable into the MS D. T his ensures that earth cable are minimis ed. er-carrying conductors s hall be sized pplicable s tandards . It is recommended utral conductor be s ized the same as (or e conducts as it is the primary return for MY D Diverter Ins tallation G uide vs s Doc #510065) connections via 8mm bolts . M8 s tud, lower right of enclos ure. connection points . e earth cable, even if the unit is bolted to CY K Min distance to ceiling 300mm 550192_msdi_cnx_dia_a4.pdf 6/10/2008 1:30:27 PM 1 S urge Diverter c tion Diagram CMY C M Y CM MY K CY CMY Connection & Line Diagram C L-N protection INP UT L3 L2 L1 F US E N E E AR T H S T UD ON C AS E 8mm NEUTRAL L3 N-E protection L2 Min distance to floor 600mm L1 L-E protection NO Protection alarm B NC EARTH STUD MAIN S W B Common-mode protection. One phase shown, all phases identical < 3m line distance Important: Before installing the device, please read & follow the installation & operation instructions. 2/23/2005 2/23/2005 LC 14 Eaton Surge Protection MAIN E AR T HING P OINT (S W B ) FROM OTHER PHASES Title A Size A4 Date: File: MS Di S eries 550192 B COM NE UT R AL LINK OR M.E .N. 1 2 3 A MSD LINE DIAGRAM Number Revision 550250 7-Aug-2006 Shee1 t of1 JDP C:\tvss engineering\Product_engineering\current\MSF\MSF.ddb Drawn By: 4 0 Eaton® SPDI Series Class I & II/Cat D, C & B Din Rail Mounted Surge Diverters Key Features: • Surge ratings starting from 40kA up to 100kA (8/20uS) • DIN43880 profile IP20 enclosure allows compatibility with most common switchboards • Versatile mounting clips offer the option of DIN rail or surface mount with ease • Clear & concise protection status indicators & a dry-contact alarm • Extended voltage range to suit most common power distribution systems Shunt Surge Diverter, 1 & 3 Phase, 40kA & 100kA Eaton's SPDI surge diverters provide the ultimate solution for surge protection in single & multi-phase systems. Whether the application involves residential homes, telecommunication facilities, hospitals, schools or heavy industrial plants, the SPDI surge diverters provide protection against the damaging effects of lightning, utility switching, switching electric motors & more. SPDI surge diverters can be installed as point-of-entry or sub-board protection & are connected in parallel with the power circuit via separate protection HRC fuses. These devices are ideal for Category C & B locations. 1 Mode (L-N) 1 Stage Diverter MOV Protection Normal Mode Power Input Class I/Cat D Power Output SPD120i Block Diagram The SPD120I is designed to protect single-phase power systems against surges & spikes caused by lightning strikes & other electrical sources. The unit is intended for point-of-entry or main board protection in medium to high exposed locations. SPD120I are easily configured for L-N or L-E protection for installations adjacent or remote from the M.E.N. link, which means it can provide protection for commercial buildings to rural sites. Eaton Surge Protection 15 Eaton® SPDI Series Class II/Cat C & B Din Rail Mounted Surge Diverters Applications: • • • • • • Ideal for Point of Entry or Sub-board Protection Telecommunication Systems & Rectifiers Process & Control Systems Computer Systems Medical Systems All Sensitive Electronic Equipment Class II/Cat C & B The SPD3NI is designed to protect 3-phase power systems against damage from surges & spikes caused by lightning & other electrical sources. The unit is intended for point-of-entry or sub-board protection in low to medium exposed locations adjacent to the M.E.N. link. For protection in locations remote from the M.E.N. link use a SPD3GI Gas Arrestor model. Surge Category 2 Mode 1 Stage Surge Diverter L1 MOV Protection L1 L2 MOV Protection L3 MOV Protection L1 Normal Mode Normal Mode L2 Power Input L2 Power Output Normal Mode L3 The SPDI is suitable for use in category locations: L3 (6kV/30KA) Point of Entry, High Exposure (SPD120I Only) N N Class II/Cat D Common Mode E E Class II/Cat C (6kV/15kA) Point of Entry/ Service Entrance SPD3Ni Block Diagram Class II/Cat B 2 Mode 1 Stage Surge Diverter L1 MOV Protection L2 MOV Protection L1 L1 L2 L2 Common Mode Power Input L3 (6kV/3kA) Major sub mains & short final sub circuits L3 MOV Protection Power Output Common Mode L3 Common Mode N Common Mode E E SPD3Gi Block Diagram 16 Eaton Surge Protection N Eaton® SPDI Specifications Technical Specifications SPD120I SPD3NI SPD3GI Input voltage 220-277VAC (380-480V) 40-70 Hz 220-277VAC (380-480V) 40-70 Hz 220-300VAC (380-520V) 40-70 Hz Maximum continuous operating voltage (MCOV) 320VAC 350VAC Temporary overvoltage - TOV 350VAC, 15 mins 420VAC, 15 mins Service Type TN-C & TN C-S (3-wire with grounded neutral) TN-S & TT (3-wire with grounded neutral) Test Classification (IEC61643-1) Class II Initial clamp voltage 560V Maximum rated surge current - Ismax 8/20us 100kA 40kA / Phase Nominal surge current - In 8/20us 50kA 20kA / Phase Residual voltage (Vpl) @ 3kA, 8/20us 1.0kV <1.2kV L-N, 900V N-E <1.2kV L-N, 1.4kV N-E Residual voltage (Vpl) @ 40kA, 8/20us 1.65kV <2.1kV L-N, 1.46kV N-E <2.1kV L-N, 2.45kV N-E Energy absorption (2ms) 2130 Joules Nominal surge lifetime (In) 50kA (8/20us), 20 times Recommended maximum overcurrent protection gG/gL HRC fuses, 1 per phase, 125A maximum Terminations Power terminals 16mm2, Alarm terminals 1.5mm2 Alarms/Indicators 5 indicators, dry contact alarm relay - 250VAC/32VDC, 5A Design standards IEC61643-1, IEC610006, ANSI/EEE C62.41, AS1768-2007, AS3100, CE mark Dimensions & Weight (DIN43880) 70 x 68 x 90 mm (WxDxH), 200g 680V 3640 Joules 20kA (8/20us), 20 times Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Connection Diagrams L-E Connection L-N Connection SPD120I SPD3NI SPD3GI Important: Before installing the device, please read & follow the installation & operating instructions. Eaton Surge Protection 17 Eaton® SPDV60 & SPDT60 Class II/Cat C & B Modular Single Pole DIN Surge Diverters Key Features: • • • • • • 1 mode plug-in protection 60kA 8/20uS maximum surge rating Compact solution for primary protection DIN43880 case, 35mm DIN-rail Removable dry-contact alarm connection Thermally protected Applications: • Mains point-of-entry / Sub-board • Factories / Workshops • Small Offices / Residential homes Shunt Surge Diverter, 1 Pole 60kA The new SPDV60-300 & SPDT60-255 single pole DIN surge diverters offer 60kA of surge suppression, making them suitable for either main or sub-board protection. The compact modular design allows the units to be easily installed in new or retrofitting existing installations. The units feature a plug-in module that may be replaced without rewiring in the event of a fault. The SPDV60-300 utilises the latest thermal MOV technology, making it suitable for pointof-entry protection in main switchboards & can be used in conjunction with an SPDT60-225 Gas Arrestor for protection on distribution boards remote from the M.E.N. point. Both models come as standard with mechanical flag status indication & a dry contact alarm for remote status monitoring. 1 Mode (L-N) 1 Stage Diverter Surge Category The SPDV60 & SPDT60 is suitable for use in category locations: Class II/Cat C (6kV/15kA) Point of Entry/ Service Entrance Class II/Cat B (6kV/3kA) Major sub mains & short final sub circuits 1 Mode (N-E) 1 Stage Diverter MOV Protection GDT Protection Normal Mode Power Input Power Output Power Input Power Output Common Mode SPDV60 Block Diagram 18 Eaton Surge Protection SPDT60 Block Diagram Eaton® SPDV60 & SPDT60 Specifications Technical Specifications SPDV60-300 SPDT60-255 Input voltage 220-250VAC (380-480V) 40-70Hz Neutral - Earth connection only. System voltage 220250VAC (380-440V) Maximum Continuous voltage - MCOV 300VAC 255VAC (no conduction under load fault conditions) Shunt Technology MOV GDT Service type TN-C & TN C-S (3-Phase with grounded neutral) Single & 3-Phase with remotely grounded neutral Test Classification (IEC61643-1) Class II Supply Current <10mA Initial clamp voltage 470V N/A Initial spark over voltage N/A 600V Maximum rated surge current - Ismax 8/20us 60kA Nominal surge current - in 8/20us 30kA 40kA Residual voltage (Vpl) @ 3kA, 8/20us 1.0kV N/A Residual voltage (Vpl) @ Ismax, 8/20us 1.4kV 1.8kV Energy absorption (2ms) 2130 Joules N/A Nominal surge lifetime (In) 30kA (8/20us), 20 times 40kA (8/20us), 20 times Internal protection MOV thermal disconnect device Thermal disconnector Recommended maximum over-current protection gG/gL HRC fuses, 1 per phase, 160A max None Terminations Power terminals 16mm2, Alarm terminals 1.5mm2 Alarms / indicators Flag indicator, dry contact alarm relay - 250VAC/24VDC, 2A Design Standards: IEC61643-1, IEC610006, ANSI/IEEE C62.41, AS1768-2007, AS3100, CE mark Dimensions & Weight (DIN43880) 17 x 68 x 90 mm (not incl relay), 100g Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Connection Diagrams SPDV60-300 SPDT60-255 Important: Before installing the device, please read & follow the installation & operating instructions. Eaton Surge Protection 19 Eaton Quickmov™ Class II/Cat C & B Integrated Quicklag Protection Device Key Features: • • • • • • • • Surge rating 30kA Inom & 60kA Imax Integrated Surge Protection solution In-built HRC fusing Dual Barrier Flame Retardant Housing Fail Safe Status Indicator Protection for MEN & non-MEN applications Compatibility with Quicklag™ accessories Designed in Australia 1 Mode (L-N) 1 Stage Diverter MOV Protection Shunt Surge Diverter, 1 Pole 60kA Normal Mode Quickmov™ is Australia's first fully integrated Surge Protection Device (SPD), designed to protect single & multi-phase electrical distribution systems against the damaging effects of voltage spikes & surges. The new Quickmov™ SPD plugs straight into a Quicklag™ loadcentre, connecting to the chassis busbar for the lowest source impedance. Its integrated HRC fuse enables the Quickmov™ to be connected directly to the neutral bar, providing the shortest possible cable length for superior protection of the entire loadcentre. The advanced MOV technology is housed in a dual barrier flame retardant case to provide optimum surge protection performance without compromising safety & reliability. The Quicklag™ range of mounting accessories compliments the Quickmov™, extending its features & benefits to many applications. Its integrated protection reduces the amount of extra components required to carry out a typical installation, saving valuable space & installation time. With a 60kA (MOV Imax) surge suppression Surge Category rating, Quickmov™ is ideal for primary protection in main The Quickmov™ is suitable for use in category locations: switchboards & can be used in conjunction with an Eaton SPD50NGI Neutral-Earth arrestor for distribution boards remote from the M.E.N. point. 20 Eaton Surge Protection Class II Cat C (6kV/15kA) Point of Entry/ Service Entrance Class II Cat B (6kV/3kA) Major sub mains & short final sub circuits HRC Fuse Power Input MOV Thermal Fuse Element Quickmov Block Diagram Power Output Eaton Quickmov™ Specifications Technical Specifications SPDQM1 Protection Mode Single Mode - connected L-N Service type TNC, TN C-S (for TNS add 1 x SPD50NGI protector) System voltage - Un 220 - 250VAC (380 - 440VAC 3 Ph) 50/60 Hz Test Classification Class II (IEC 61643-1), Category C3 (ANSI/IEEE C62.41) Maximum Continuous Over Voltage (MCOV - Uc) 300VAC Temporary Over Voltage (TOV) (5s) 330VAC External disconnector requirements None. In-built 100AgL/50kA HRC fuse Surge current rating In (20 times) 30kA (8/20us) Surge current rating Ismax (2 times) 60kA (Imax MOV rating, 8/20us) Residual voltage (Vpl) @ 3kA 1.1kV (cable trimmed to 250mm) Residual voltage (Vpl) @ In 1.8kV (device only) Connections Quicklag™ terminal for phase connection. 6mm2 cable (black) for Neutral connection (500mm length) Dimensions & Weight 25 x 71 x 93 mm (WxDxH), 310g Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Connection Diagram Important: Before installing the device, please read & follow the installation & operating instructions. Eaton Surge Protection 21 Eaton PVD40 Series Class II/Cat C & D Photovoltaic Diverters The PVD series diverters are designed to protect the DC input side of grid interactive inverters from harmful transients that can appear on the output of solar arrays, especially where they are located on roof or other high infrastructure locations. These units can be combined with existing SPDV60 series diverters on the AC Input/Output side of the inverter to provide complete protection from surges & thus increasing the life of a grid interactive solution investment. IEC61643-1 & UL1449 ed3 compliant. Available in 3 models to suit nominal 500, 600 & 1000VDC systems. Key Features Shunt Surge Diverter, 60kA The new PVD series diverters are designed to protect home & industrial solar panel arrays commonly used in grid interactive power solutions in the 1.5kW to 10kW range. These systems commonly use voltages between 500-1000VDC from the solar panels. • • • • 2 mode plug in protection 40kA surge suppression rating Compact modular solution 2 & 3 unit DIN43880 case, 36 & 54mm DIN-rail mount Applications • Standalone & Grid Interactive Solar arrays. Technical Specifications PVD40-500-V-C PVD40-600-V-C PVD40-1000-V-CD Nominal Voltage Un 500VDC 600VDC 1000VDC Voltage Uc 530VDC 620VDC 1060VDC Nominal Discharge Current ( 8/20us, kA ) Inom. 20 20 20 Max Discharge Current ( 8/20us, kA ) Imax. 40 40 40 Nominal current (ma) IL 10 10 10 Residual voltage (Vpl) @ Inom 20kA, 8/20us 1.6kV 2.0kV 3.2kV Test classification Class II Class II Class II External disconnector ( if required ) 125A Gg/Gl fuse 125A Gg/Gl fuse 125A Gg/Gl fuse Internal protection MOV thermal disconnect MOV thermal disconnect MOV thermal disconnect Alarm & indicators Red flag indicator on module Alarm relay contact. 250vac/24vdc, 2A Red flag indicator on module Alarm relay contact. 250vac/24vdc, 2A Red flag indicator on module Alarm relay contact. 250vac/24vdc, 2A Terminations Main terminals 25mm Alarm terminals 1.5mm Main terminals 25mm Alarm terminals 1.5mm Main terminals 25mm Alarm terminals 1.5mm Degree of protection ( IP rating ). 20 20 20 Mounting Din rail Din rail Din rail Enclosure material UL94 V0 UL94 V0 UL94 V0 Environment temperature ( C ) -10 to 60c, 0-90% RH -10 to 60c, 0-90% RH -10 to 60c, 0-90% RH Applicable standards IEC61643-1:2000 UL1449 ed3 IEC61643-1:2000 UL1449 ed3 IEC61643-1:2000 UL1449 ed3 Weight 180g 180g 240g Dimensions 90mm (H) x 36mm (W) x 68mm (D) excluding alarm connectors 90mm (H) x 36mm (W) x 68mm (D) excluding alarm connectors 90mm (H) x 54mm (W) x 68mm (D) excluding alarm connectors Warranty 12 months 12 months 12 months 22 Eaton Surge Protection Faster than a speeding bullet Much faster. In microseconds a power surge can do major damage to sensitive equipment and data. It can come from anywhere, and like a bullet, you only know it has been by the destruction left behind. That's why surge protection is so critical. And why Eaton builds so much quality into our full line of Powerware surge protection products. Eaton has a world beating reputation for Power Quality and a full range of surge protection solutions, covering every eventuality. Eaton Surge Protection 23 Secondary Point Protection Class II/Category B (6kV/3kA) 24 Eaton Surge Protection Powerware® MSFI Class II/Cat C & B 1 & 3 Phase 40-63A Series Surge Filters Typical applications: • • • • • All Power Circuits including "Point-of-Entry" Telecommunications Systems & Rectifiers Process & Control Systems & UPS Systems Computer Systems & Medical Systems All sensitive Electronic Equipment Key Features: • • • • • • • Series Filter with Shunt Surge Diverter, 1 & 3 Phase, 40A, 63A & 160kA Surge suppression & filtering in a single package 1 mode, 2 Element Series Filter 3 Mode, 2 Stage Surge Diverter Surge suppression rating of 160kA Power & Protection status indicators Protection Fail Alarm Relay 5 Year Warranty The MSFI is designed to provide point-of-entry protection against power surges caused by external sources such as lightning strikes & substation switching as well as providing a measure of protection from surge events generated on the secondary side of the filter. An ideal device for Category B & some Category C locations. The MSFI is a 3-stage protection unit utilising primary & secondary MOV protection in conjunction with a Low-Q LC filter. The unit provides filtering of the line harmonics, noise & RF transmitters with a cut-off frequency of <10kHz & a minimum attenuation of 40dB above 1MHz. Special care has been taken in the design of the filter to minimise ringing caused by light loads, surge diverter operation & inductive load back-EMF. 1 Mode 2 Element Series Filter 3 Mode 2 Stage Surge Diverter Surge Category Primary MOV Protection The MSFI is suitable for use in category locations: Normal Mode Series Blocking Inductor High Frequency Capacitor Secondary MOV Protection Normal Mode Class II/Cat C (6kV/15kA) Point of Entry/ Service Entrance Power Input Power Output Common Mode Class II/Cat B (6kV/3kA) Major sub mains & short final sub circuits MSFi Block Diagram (Single Phase shown) Eaton Surge Protection 25 Eaton® MSFI Specifications Technical Specifications MSF401CCMI Input voltage 220 – 254VAC 1 Phase MSF631CCMI MSF403CCMI MSF633CCMI Maximum continuous voltage - MCOV 320VAC Temporary overvoltage - TOV 350VAC, 15 mins Service type TT, TN, TN C-S or any system with a grounded neutral. This unit must not be connected to an ungrounded system Test Classification Class II (IEC 61643-1), Category C3 (ANSI/IEEE C62.41) Energy Absorption rating - per mode (joules) Primary protection L-N = 2,400J/ph, Three Phase unit = 7,200J total Secondary protection L-N = 600J/ph, Three Phase unit = 1,800J total Common mode protection L-N & N-E = 1,420J, Three Phase unit = 4,280J total Aggregate rating 4,420J (single phase units), 13,260J (three phase units) 380 - 440VAC 3 Phase Current rating - continuous 40A 63A 40A 63A Recommended maximum over current protection 40A 63A 40A 63A Short circuit withstand (1 sec) 29kA Protection modes Line-Neutral, Line-Earth, Neutral-Earth In 8/20us (Line-Neutral) Nom. surge life 60kA x 20 hits 60kA x 20 hits/ph In 8/20us (Line-Earth) Nom. surge life 15kA x 20 hits 15kA x 20 hits/ph In 8/20us (Neutral-Earth) Nom. surge life 15kA x 20 hits 45kA x 20 hits Ismax 8/20us (Line-Neutral) Max surge level 160kA 160kA/ph Ismax 8/20us (Line-Earth) Max surge level 40kA 40kA/ph Ismax 8/20us (Neutral-Earth) Max surge level 40kA 120kA/ph Filter attenuation 40dB nominal above 1MHz Initial clamp voltage (Line-Neutral) 560V (350Vac RMS) Initial clamp voltage (Line-Earth) 680V (420Vac RMS) Initial clamp voltage (Neutral-Earth) 680V (420Vac RMS) Internal protection (fusing) All surge diverter connections are fused via HRC fuses to IEC269-2-1 Alarms/indicators 2 LED display, dry contact alarm relay output – 250Vac/32Vdc, 10A, 4kV isolation, Alarm under-voltage cutoff 180Vac. Enclosure rating IP24 Design Standards: IEC61643-1, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B,C,D,E AS1768-2007 Cat B,C,D,E AS3000,AS3100, CE mark Dimensions 210 x 160 x 560 mm (W x D x H) 370 x 160 x 560 mm (W x D x H) Weight 9kg 14Kg Environment -10 to 65°C, 10 to 90%RH (non-condensing) Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Connection Diagrams as e MS F i S urge F ilter onnec tion Diagram S ingle P has e MS F i S urge F ilter C onnec tion Diagram Min dis tance to ceiling 300mm r MS F 323C C Mi, MS F 403C C Mi, MS F 633C C Mi Min distance to ceiling 300mm F or MS F 321C C Mi, MS F 401C C Mi, MS F 631C C Mi his doc ument is to be us ed in c onjunc tion with T his doc ument is to be us ed in c onjunc tion with N P has e S urge F ilter Ins tallation G uide (T vs s Doc #510063) L1 L2 L3 OUT P UT N S ingle P has e S urge F ilter Ins tallation G uide (T vs s Doc #510064) LOAD OUT P UT L LOAD E arth E arth I MP OR T ANT N OT E S : N OT E S : s e and neutral connections via 8mm bolts. onnection via M8 s tud, lower right of enclos ure. o labelling for connection points. run a s eparate earth cable, even if the unit is bolted to B tray. nput and output cables phys ically separated at all times. paration dis tance 500mm. us es are preferred to MC B s for connection to main S W B . ge 2 on ins tallation guide for details. to be located within 3m (cable length) of the main system nd Neutral link for point-of-entry application. G reater reduce protection. wiring: F or proper operation of this MS F it is essential that s t and phys ically s hort earth connection be made to the rthing point. W ith reference to local wiring standards, ables are us ually s ized agains t a thermal rating, ined by expected fault currents , (5,000 to 25,000 amps). ns talling an MS F however, the installer must be aware rge currents can exceed 50,000 amps, and therefore r cables are generally required to limit voltage drops s urge conditions . T o achieve these requirements, the able s ize s hould be s elected to be equal to, or greater he larges t incoming cable into the MS F . T his ensures that drops on the earth cable are minimis ed. wiring: All power-carrying conductors s hall be s ized ing to locally-applicable s tandards. It is recommended e incoming neutral conductor be sized the same as (or han) the phas e conducts as it is the primary return for utral s urges. N L1 L2 L3 E 1. 2. 3. 4. Earth Stud On Case 8mm 6. 5. 7. Min dis tance to floor 600mm 8.1. MAIN S WB 3 Phase Connection 2/23/2005 2/23/2005 INP UT LC 26 Eaton Surge Protection MAIN E AR T HING P OINT (S W B ) 8.2 All phas e and neutral connections via 8mm bolts. E arth connection via M8 s tud, lower right of enclos ure. R efer to labelling for connection points. Always run a s eparate earth cable, even if the unit is bolted to the S W B tray. K eep input and output cables phys ically separated at all times. Min. s eparation dis tance 500mm. HR C fus es are preferred to MC B s for connection to main S W B . S ee P age 2 on ins tallation guide for details. Unit is to be located within 3m (cable length) of the main system E arth and Neutral link for point-of-entry application. G reater lengths reduce protection. E arth wiring: F or proper operation of this MS F it is essential that a robus t and phys ically s hort earth connection be made to the s ite earthing point. W ith reference to local wiring standards, earth cables are us ually s ized agains t a thermal rating, determined by expected fault currents , (5,000 to 25,000 amps). W hen ins talling an MS F however, the installer must be aware that s urge currents can exceed 50,000 amps, and therefore heavier cables are generally required to limit voltage drops under s urge conditions . T o achieve these requirements, the earth cable s ize s hould be s elected to be equal to, or greater than, the larges t incoming cable into the MS F . T his ensures that voltage drops on the earth cable are minimis ed. Other wiring: All power-carrying conductors s hall be s ized according to locally-applicable s tandards. It is recommended that the incoming neutral conductor be sized the same as (or larger than) the phas e conducts as it is the primary return for line-neutral s urges. N E MAIN S WB Important: Before installing the device, please read & follow the installation & operating instructions. LC MAIN E AR T HING P OINT (S W B ) Single Phase Connection 2/25/2005 2/25/2005 Earth Stud On Case 8mm Min distance to floor 600mm 3-P has e MS F i S eries 550190 INP UT L S ingle P has e MS F i S eries 550191 Eaton® DSFI Class II/Cat B & A Single Phase High Performance Surge Filter Applications: • • • • • • • Secondary power circuits/Sub-boards UPS Systems & Rectifiers Telecommunications Systems & Rectifiers Process & Control Systems & UPS's up to 6kVA Computer Systems & Medical Systems AV circuits for clubs & hotels All sensitive Electronic Equipment Key Features: • • • • • • Series Filter with Shunt Surge Diverter, 1 Phase 5-32A, 40kA Primary Surge suppression & filtering in a single package Modular design Enclosed in IP20 painted steel housing Protection Fail Alarm Relay 3 mode, 3 Stage Protection 5 Year Warranty The DSFI is designed to provide secondary protection against power surges caused by external sources such as lightning strikes & substation switching as well as providing a measure of protection from surge events generated on the secondary side of the filter. The DSFI is a 3-stage protection unit utilising primary & secondary MOV protection in conjunction with a 2-stage Low-Q LC filter (i.e. 2 inductive coils) using separate differential mode & common mode circuits. The unit provides filtering of the line harmonics, noise & RF transmitters with a cut-off frequency of <1.5kHz & a minimum attenuation of >55dB to 10MHz. Secondary MOV protection (in all 3 modes) is located after the inductive coils, to provide further surge reduction & to protect against load-generated surges. An ideal device for Category B & A locations. 2 Mode 5 Element Series Filter 3 Mode 2 Stage Surge Diverter Surge Category Primary MOV Protection The DSFI is suitable for use in category locations: Series Blocking inductor High Frequency Capacitor Series Blocking Inductors High Frequency Capacitor Normal Mode No M Secondary MOV Protection Normal Mode Class II/Cat B (6kV/3kA) Major sub mains & short final sub circuits Power Input Power Output Common Mode Common Mode Class II/Cat A (6kV/200A) Long final sub circuits & power outlets DSFi Block Diagram Eaton Surge Protection 27 Eaton® DSFI Specifications Technical Specifications DSFI Input voltage 200-250VAC 1 Phase Service type TT, TN, TN C-S or any single-phase system with a grounded neutral. Test Classification Class III (IEC 61643-1), Category A & B (ANSI/IEEE C62.41) Energy Absorption rating - per mode (joules) Primary Protection L-N = 740 J Primary common mode protection L-E & N-E = 780 J Secondary protection L-N = 225J Secondary common mode protection L-E & N-E = 480J Aggregate rating = 2,225J Current rating – continuous 5 - 32A Recommended max. overcurrent protection 32A (C curve MCCB) Short circuit withstand (1 sec) Suitable for use with a 6kAIC C Curve MCB Protection modes Line-Neutral, Line-Earth, Neutral-Earth In 8/20us (Line-Neutral) 15kA x 20 hits In 8/20us (Line-Earth) 10kA x 20 hits In 8/20us (Neutral-Earth) 10kA x 20 hits Ismax 8/20us (Line-Neutral) 40kA Ismax 8/20us (Line-Earth) 25kA Ismax 8/20us (Neutral-Earth) 25kA Filter attenuation >55dB to 10MHz Internal protection (fusing) Thermal Terminations 10mm2 PCB Mounted Terminals Alarms/indicators 2 LED display, Power OK & Protection OK LEDs, Dry contact alarm relay output – 250Vac/32Vdc, 5A, 5kV isolation, Alarm under-voltage cutoff 180Vac Enclosure rating IP20 Design Standards: IEC61643-1, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B,C,D,E AS1768-2007 Cat B,C,D,E AS3000,AS3100, CE mark Dimensions & Weight 140 x 50 x 270 mm (W x D x H), 1.5kg Environment -10 to 65°C, 10 to 90%RH (non-condensing) Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Connection & Line Diagram 1 2 3 4 D D Differential filtering LINE IN Common mode filtering Thermal fuse LINE OUT INDUCTOR Indicator/Alarm C L-N protection C L-N protection CM TX NEUTRAL IN NEUTRAL OUT N-E protection L-E protection L-E protection N-E protection B B EARTH STUD EARTH STUD Common-mode protection. Title A A4 Important: Before installing the device, please read & follow the installation & operating instructions. 1 28 Eaton Surge Protection A DSFi FILTER LINE DIAGRAM Size 2 Date: File: 3 Number Revision 550248 7-Aug-2006 Shee1 t of1 JDP C:\tvss engineering\Product_engineering\current\MSF\MSF.ddb Drawn By: 4 0 Eaton® CSFI Class II/Cat B & A Din Rail Compact Surge Filter Applications: • • • • • • Secondary power circuits, Sub-boards UPS Systems & Rectifiers Telecommunications Systems Process & Control Systems, Homes & Units Computer Systems & Medical Systems All sensitive Electronic Equipment Key Features: • • • • • • • Series Filter with Shunt Surge Diverter, 1 Phase 3-25A, 25kA Primary Surge suppression & filtering in a single package Modular design Enclosed in IP 20 ABS plastic housing DIN rail mountable (4 pole wide) Protection Fail Alarm Relay 3 mode, 3 Stage Protection 12 Month Warranty The CSFI is designed for mounting in distribution boards to provide secondary protection against power surges caused by external sources such as lightning strikes & substation switching as well as providing a measure of protection from surge events generated on the secondary side of the filter. An ideal device for Category B locations. The CSFI is a 3-stage protection unit utilising primary & secondary MOV protection in conjunction with a Low-Q LC filter. The unit provides filtering of the line harmonics, noise & RF transmitters with a cut-off frequency of <10kHz & a nominal attenuation of >60dB. All CSFI units are provided with indicators showing power & protection status. Alarms are indicated on the front panel of the unit. The alarm function provides a summary alarm output for protection degradation as well as power failure. The protection alarm is configured to partial protection failure. The summary alarm relay contacts provide remote signalling to other equipment. 2 Mode 3 Element Series Filter 3 Mode 2 Stage Surge Diverter Surge Category The CSFI is suitable for use in category locations: Primary MOV Protection High Frequency Capacitor Normal Mode Class II/Cat B (6kV/3kA) Major sub mains & short final sub circuits Series Blocking Inductors Secondary MOV Protection Normal Mode Power Input Power Output Common Mode Common Mode Class II/Cat A (6kV/200A) Long final sub circuits & power outlets CSFi Block Diagram Eaton Surge Protection 29 Eaton® CSFI Specifications Technical Specifications CSFI Input voltage 200-250VAC 1 Phase Service type TT, TN, TN C-S or any single-phase system with a grounded neutral. This unit must not be connected to an ungrounded system Test Classification Class III (IEC 61643-1), Category A & B (ANSI/IEEE C62.41) Energy Absorption rating - per mode (joules) Primary protection L-N = 370J Primary common mode protection L-E & N-E = 480J Secondary protection L-N = 225J Secondary common mode protection L-E & N-E = 480J Aggregate rating = 1555J Current rating - continuous 3 - 25A Recommended max. overcurrent protection 25A (C curve MCB 25A) Protection modes Line-Neutral, Line-Earth, Neutral-Earth In 8/20us (Line-Neutral) Nominal surge life 10kA x 20 hits In 8/20us (Line-Earth) Nominal surge life 3kA x 20 hits In 8/20us (Neutral-Earth) Nominal surge life 3kA x 20 hits Ismax 8/20us (Line-Neutral) Max surge level 25kA Ismax 8/20us (Line-Earth) Max surge level 10kA Ismax 8/20us (Neutral-Earth) Max surge level 10kA Filter attenuation 62dB above 1MHz Internal protection (fusing) All surge diverter connections are fused via HRC fuses to IEC269-2-1 Terminations 6mm2 PCB Mounted Terminals Alarms/indicators 2 LED display, Power OK & Protection OK LEDs, Dry contact alarm relay output – 250Vac/32Vdc, 5A, 5kV isolation, Alarm undervoltage cutoff 180Vac Location Category Indoor Enclosure rating IP20 Design Standards: IEC61643-1, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B,C,D,E AS1768-2007 Cat B,C,D,E AS3000,AS3100, CE mark Dimensions & Weight 70 x 68 x 90 mm (W x D X H), 200g Environment -10 to 65°C, 10 to 95%RH (non-condensing) Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Connection & Line Diagram 1 2 3 4 D D LINE IN Differential protection Differential and common-mode filtering Thermal fuse LINE OUT Indicator/Alarm C L-N protection CM TX CF C L-N protection NEUTRAL IN NEUTRAL OUT N-E protection L-E protection L-E protection N-E protection B B EARTH IN EARTH OUT Common-mode protection. Important: Before installing the device, please read & follow CSFi/SSFi/SF1510i/SF8R/POD FILTER LINE DIAGRAM the installation & operating instructions. 0 Title A Size A4 Date: File: 1 30 Eaton Surge Protection 2 3 Number Revision 550247 7-Aug-2006 Shee1 t of1 JDP C:\tvss engineering\Product_engineering\current\MSF\MSF.ddb Drawn By: 4 A Eaton SPD50NGI Class II/Cat C & B Neutral-Earth Surge Protector Applications: • Equipotential Coupler • Neutral-Earth Surge Arrestor • Sub-boards remote from MEN point Key Features: • Compact Neutral-Earth Protection Solution • Surge current rating from 50kA - 100kA In, 70kA - 150kA Imax • Compatible with most switchboards • Quick & simple installation Neutral-Earth or Earth-Earth Equipotential Clamp The SPD50NGI is designed for use as an equipotential coupler between separately-grounded systems to provide protection against surge transients. Under normal conditions the coupler does not conduct, preventing earth loops & inter-circuit coupling. Under surge conditions, effectively interconnecting the circuits for the duration of the surge. The SPD50NGI is an ideal companion for the Quickmov™ surge diverter for surge protection in distribution boards remote from an M.E.N point. the SPD50NGI equipotential coupler (gas arrestor) is connected between the neutral & earth bar for N-E surge protection. The SPD50NGI is suppllied as an "in-line" cable assembly for ease of installation. Surge Category 1 Mode (N-E) 1 Stage Diverter The SPD50NGI is suitable for use in category locations: GDT Protection Class II/Cat C Power Input Power Output Common Mode (6kV/15kA) Point of Entry/ Service Entrance Class II/Cat B (6kV/3kA) Major sub mains & short final sub circuits SPD50NGi Block Diagram Eaton Surge Protection 31 Eaton SPD50NGI Specifications Technical Specifications SPD50NGI Protection Mode Single Mode - connected Neutral-Earth or between separately earthed systems Service type (N-E protection only) TNS or similar (neutral must be grounded either locally or remotely) System voltage - Un Applicable to any common LV system voltage Test Classification Class I & II (IEC 61643-1) Cat B & C ANSI C62.41 External disconnector requirements None DC breakdown voltage (1mA) 230V +/-20% Firing voltage 800V +-20% Operating current <1mA Surge current rating In (20 times) 50kA (8/20us) Surge current rating Ismax (2 times) 70kA (8/20us) Residual voltage with full cable <1.3kV (3kA, 8/20uS) Residual voltage with minimal cable (100mm total) <1.3kV (15kA, 8/20uS) <2.5kV (50kA, 8/20uS) Connections 6mm2 cable (black & green/yellow) for connection Mounting None required for fixed installation (suspended by cable) Dimensions & Weight 60 x 15 x 15 mm (not including cables), 70g Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Connection Diagram Sub-board with remote MEN link connection Important: Before installing the device, please read & follow the installation & operating instructions. 32 Eaton Surge Protection Point of Use Protection Class III/Category A (6kV/200A) Eaton Surge Protection 33 Eaton® POD Class III/Cat A Surge Powerboard for IT & AV applications Series Power Filter & Shunt Surge Diverter 10A, 220-250V, 60kA The Eaton POD protects your precious Computer System, Home Entertainment System & other valuable electronic equipment from surges, spikes & noise caused by lightning & other power disturbances. Its series power filter provides superior protection against surges & spikes, with the additional benefit of protecting against line noise that may affect sensitive equipment. With a surge rating of 60kA, the POD out-performs & outlasts many other products that provide shunt-only protection. The POD not only protects your power circuits, but also protects against “back door” surges that can enter your systems telephone lines, aerials or network cables. The POD is manufactured from the highest quality materials & is ergonomically & aesthetically designed to suit office & home installations. Rest easy with a five year full replacement warranty & a $100,000 load protection guarantee* (Australia & New Zealand). • • • • • • • • • POD 6 Outlet or POD+ 8 Outlet models 60,000 Amp surge protection Highest quality power sockets with extra wide spacing Visual indication of Power & Surge Protection status 1.8 metre power cord with insulated pins Resettable circuit breaker Power On/Off switch Data, Video/Aerial & Phone Line surge protection on POD Data, Video/Aerial, Cable TV & Phone Line surge protection on POD+ • Network cable, telephone cable & Coax cable supplied • Wall mountable to save valuable floor space 2 Mode 3 Element Series Filter 3 Mode 2 Stage Surge Diverter Surge Category Primary MOV Protection POD & POD+ are suitable for use in category locations: Series Blocking Inductors High Frequency Capacitor Normal Mode Class III/Cat A (6kV/200A) Long final sub circuits & power outlets Key Features: Normal Mode Power Input Power Output Common Mode Common Mode POD Block Diagram 34 Eaton Surge Protection Secondary MOV Protection Eaton® POD Specifications Power Connections POD POD+ Input Voltage: 220-250VAC Phone/Fax Connections (RJ11) POD POD+ Nominal Line Impedance 6000 Ohms Frequency: 50/60Hz Maximum Line Voltage Maximum Continuous Load: 10 Amps Clamping Voltage (Line to Line) 430V (270Vac RMS) Clamping Voltage (Line to Earth) 600V (375Vac RMS) Test Classification Class III (IEC 61643-1), Category A (ANSI/IEEE C62.41) Current Limiting: Resettable Circuit Breaker Clamping Voltage (Line to Neutral): 470V Clamping Voltage (Neutral to Earth): 680V 275Vrms Response Time 500ns nominal Maximum Surge Current Peak let-through voltage (3kA L-L) Response Time: 5nS Nominal Aggregate Surge Current: 60,000 Amps Aggregate energy absorption Video/Aerial Connections Connections Maximum surge current (one pulse L-N): 40,000 Amps Maximum surge current (one pulse L-E): 10,000 Amps Nominal Line Impedance Maximum surge current (one pulse N-E): 10,000 Amps Signal Loss Aggregate Energy Absorption: 1470 Joules Clamping Voltage Attenuation at full load: >40dB @ 1MHz Network Connections (RJ45) POD 300 joules POD POD+ Video Connector Video Connector & F Type Screw Connector 75 Ohms Approx. 3dB @ 500MHz 600V (375 Vac RMS) Maximum Surge Current POD+ Lines Protected 20,000 Amps 1000V 1/2, 3/6 Dimensions (L x W x Hmm) Weight Clamping Voltage (Line to Line) <20V Clamping Voltage (Line to Earth) 600V (375 Vac RMS) Surge Current - Amp (10/1000us) 20 Amps (2ms) / 40 20,000 Amps Aggregate energy absorption 200 joules 338 x 130 x 42 383 x 130 x 42 0.8 kg Power Cord 1.0 kg 1.8 metres length Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Layout Diagrams Circuit B reaker Indication for Protected & Earthed Power Sw itch with illumination TV Antenna In/Out Network (broadband / Ethernet) Telephone / Fax / Answeri ng machine etc. Circuit B reaker Indication for Protected & Earthed Power Sw itch with illumination TV Antenna In/Out Network (broadband / Ethernet) Ex tra-wide spacing for plug packs Insulated pins Telephone / Fax / Answeri ng machine etc. Ex tra-wide spacing for plug packs Insulated pins Eaton Surge Protection 35 Eaton® SSFI Class III/Cat A Portable Surge Filter Applications • • • • • • Plug-in UPS systems Servers Portable instrumentation POS systems Small office systems Industrial & rural surge prone sites Key Features Surge Filter, 1 Phase 10A & 15A, 25kA Primary • • • • • • • Surge suppression & filtering in a single package Small footprint, modular design Enclosed in IP 20 painted metal housing Surge suppression rating of 20kA (L-N) Protection Fail Indicators 3 mode, 3 Stage Protection 12 Month Warranty The SSFI is designed to provide secondary protection against power surges caused by external sources such as lightning strikes & substation switching, as well as providing a measure of protection from surge events generated on the secondary side of the filter. The unit has been designed in accordance with AS3100, AS1768, IEC61643-1, IEC61000-6-1, 2, 3, 4 & other standards & codes as applicable. The SSFI is a 3-stage protection unit utilising primary & secondary MOV protection in conjunction with a Low-Q LC filter. The unit provides filtering of the line harmonics, noise & RF transmitters with a cut-off frequency of <10kHz & a minimum attenuation of 40dB above 1Mhz. The operation status of the SSFI is indicated by lamps on the front panel. The "OK" light indicates that power is applied to the SSFI. The "FAULT" light indicates that the surge protection circuitry is damaged & the unit should be replaced. An ideal device for Category A locations. 2 Mode 3 Element Series Filter 3 Mode 2 Stage Surge Diverter Surge Category Primary MOV Protection SSF10I & SSF15I are suitable for use in category locations: Series Blocking Inductors High Frequency Capacitor Normal Mode Secondary MOV Protection Normal Mode Class III/Cat A (6kV/200A) Long final sub circuits & power outlets Power Input Power Output Common Mode Common Mode SSFi Block Diagram 36 Eaton Surge Protection Eaton® SSFI Specifications Technical SSF10I SSF15I Number of ports 2 Port Method of mounting Portable Input voltage - Uc 200-250VAC 1 Phase Maximum Continuous voltage - MCOV 285VAC L-N Temporary overvoltage - TOV 300VAC L-N, 15 mins Service type TT, TN, TN C-S or any 1 phase system with a grounded neutral. This unit must not be connected to an ungrounded system. Test Classification Class II Energy Absorption rating - per mode (joules) Primary Protection L-N = 370J Primary Common Mode protection L-E & N-E = 480J Secondary protection L-N = 225J Secondary Common Mode protection L-E & N-E = 480J Aggregate rating = 1,555J Current rating - continuous 10A Test Classification 15A Class III (IEC 61643-1), Category A (ANSI/IEEE C62.41) Recommended max. overcurrent protection 10A 15A Residual current <0.5 mA Protection modes Line-Neutral, Line-Earth, Neutral-Earth In 8/20us (Line-Neutral) Nominal surge life 10kA x 20 hits In 8/20us (Line-Earth) Nominal surge life 3kA x 20 hits In 8/20us (Neutral-Earth) Nominal surge life 3kA x 20 hits Ismax 8/20us (Line-Neutral) Max surge level 20kA Ismax 8/20us (Line-Earth) Max surge level 10kA Ismax 8/20us (Neutral-Earth) Max surge level 10kA Filter attenuation 40dB nominal above 1MHz Initial clamp voltage (Line-Neutral) 560V Initial clamp voltage (Line-Earth) 680V Initial clamp voltage (Neutral-Earth) 680V Residual voltage (Vpl) (Line-Neutral) (Let through voltage) <1100 (3kA, 8/20uS) Residual voltage (Vpl) (Line-Earth) (Let through voltage) <1400 (3kA, 8/20uS) Residual voltage (Vpl) (Neutral-Earth) (Let through voltage) <1400 (3kA, 8/20uS) Internal protection (fusing) Thermal fusing on primary line-connected MOVs Terminations IEC 320-C14 10A input x 1, , IEC 320-C13 10A output x 1 IEC 320-C20 16A input x 1,, IEC 320-C19 16A output x 1 Alarms/indicators 2 LED display, Power OK, Protection Fault Location Category Indoor Enclosure rating IP20 Design Standards: IEC61643-1, IEC610006-1, 2, 3, 4 ANSI/IEEE C62.41 Cat B, C, D, E AS1768-2007 Cat B, C, D, E AS3000, AS3100, CE mark Dimensions & Weight 155 x 150 x 50 mm (W x D x H), 500g Environment -10 to 60oC, 0 to 95% RH (non-condensing) Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Line Diagram 1 2 3 4 D D LINE IN Differential protection Differential and common-mode filtering Thermal fuse LINE OUT Indicator/Alarm C L-N protection CM TX CF C L-N protection NEUTRAL IN NEUTRAL OUT N-E protection L-E protection L-E protection N-E protection B B EARTH IN EARTH OUT Common-mode protection. Title A CSFi/SSFi/SF1510i/SF8R/POD FILTER LINE DIAGRAM Size A4 Date: File: 1 2 3 Number Revision 550247 7-Aug-2006 Shee1 t of1 JDP C:\tvss engineering\Product_engineering\current\MSF\MSF.ddb Drawn By: 4 A 0 Eaton Surge Protection 37 Eaton SPD-DM Series Class III/Cat A 5-48V Surge Diverters Key Features: • • • • 1 mode plug-in protection 10kA surge suppression rating Compact solution for data systems protection DIN43880 case, 13mm wide Applications: • Data networks signalling protection Specifications: DM Series The new SPD ‘D’ series digital signalling surge diverters are designed for low voltage data signalling systems in the 5 volt to 48 volt range. Models are available in 5, 12, 24 & 48 volt DC. All are IEC 61643-21:2000 compliant. Part Code Description SPD-DM05 1 Pole, 5vdc, 10kA, 1 mode Surge Diverter w/ removable module SPD-DM12 1 Pole, 12vdc, 10kA, 1 mode Surge Diverter w/ removable module SPD-DM24 1 Pole, 24vdc, 10kA, 1 mode Surge Diverter w/ removable module SPD-DM48 1 Pole, 48vdc, 10kA, 1 mode Surge Diverter w/ removable module Technical Specifications SPD-DM05 SPD-DM12 SPD-DM24 SPD-DM48 Nominal Voltage Un 5 12 24 48 Max Continuous Voltage Uc AC/DC 5/6 12/15 24/28 48/60 Nominal Discharge Current ( 8/20us, kA ) per line. Inom. 5 5 5 5 Max Discharge Current ( 8/20us, kA ) Per line. Imax. 10 10 10 10 Nominal current (A) IL 0.5 0.5 0.5 0.5 Voltage Protection Level ( 8/20us, V ) Up Line –Line Line - Ground <80v <350v <150v <350v <200v <500v <250v <500v Voltage Protection Level ( 1KV/us, V ) Up Line - Line Line - ground <10v <600v <18v <600v <30v <600v <70v <600v Series impedance per line ( Ohm ) 4 4 4 4 Insertion loss at 100Mhz (dB) <3.0 <3.0 <3.0 <3.0 Degree of protection ( IP rating ). 20 20 20 20 Mounting Din rail Din rail Din rail Din rail Enclosure material UL94 V0 UL94 V0 UL94 V0 UL94 V0 Environment temperature ( C ) -40 to 80c, 0-90% RH -40 to 80c, 0-90% RH -40 to 80c, 0-90% RH -40 to 80c, 0-90% RH Warranty ( months ) 12 12 12 12 38 Eaton Surge Protection Eaton EMTJ & ERAK Series Class III/Cat A CAT5, CAT6 & Power-over Ethernet Dataline Protectors ECAT6PPC ERAK16EC5 Key Features: • • • • • State-of-the-art avalanche diode & thyristor technology Improved reliabillity & maximised systems up-time High-speed, high-energy handling capability Easy to install, compact, in-line installation Manufactured in the USA EMTJC6 EMTJ Series ERAK Series Eaton's EMTJ series of single port I/O devices guard sensitive data networks against lightning induced surges, ac power interference, & electrostatic discharge & ground loop energies. The EMTJ Series offer protection for LAN interface technologies such as Ethernet, 10/100BaseT, CAT5, CAT5e, CAT6 & Power over Ethernet. Eaton's ERAK Series offer 16-port flush mount 19-inch relay rack protectors for either 10/100BaseT Ethernet (CAT5) or Power over Ethernet protection. Typical applications include: Network Interface Cards (NICs), switches, hubs, repeaters, bridges, routers, point-of-sale terminals, modems, fax machines, telephones & most types of communication equipment utilising RJ45 modular telephone jacks. Whether for a single network concentrator or an entire relay rack of voltage-sensitive equipment, ERAK series protectors are one of the most cost-effective & versatile devices of their kind. These devices exhibit an extremely fast response time of less than 5 nanoseconds. Model EMTJC6 ECAT6PPC EMTJPOE60V Model ERAK16EC5 ERAK16POE60V Network Type CAT6/5/5e CAT6 POE Network Type CAT5 POE Clamp Voltage 12V 7.5V Pins 1,2,3 & 6 - 7.5V Pins 4,5,7 & 8 - 60V Number of ports 16 16 Clamp Voltage 7.5V Pins 1,2,3 & 6 - 7.5V Pins 4,5,7 & 8 - 60V Max surge current 132A (10/1000uS) Pins 1,2,3 & 6 - 132A Pins 4, 5,7 & 8 - 50A Response Time < 5 ns < 5 ns Max shunt capacitance < 40 pF < 25 pF (Ethernet Lines Only) Size 483x89x20 mm (19" 2RU) 483x89x20 mm (19" 2RU) Weight 0.64 kg 0.64 kg Max surge current 97A (10/1000uS) 132A (10/1000uS) Pins 1,2,3 & 6 - 132A Pins 4, 5,7 & 8 - 50A Response Time < 5 ns < 5 ns < 5 ns Max shunt capacitance < 25 pF < 5 pF (Device Only) < 25 pF (Ethernet Lines Only) Size (not incl cable) 91x37x23 mm 91x37x23 mm 91x37x23 mm Weight 0.1kg 0.1kg 0.1kg Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. Eaton Surge Protection 39 Eaton® SF8RM Class II & III/Cat B & A Single Phase Rack Mounted Filter/PDU Key Features • • • • Surge Filter, 1 Phase 10A, 25kA Primary 8 way 10A Power Filter Can be rack or surface mounted 3 mode, 3 stage protection Resettable circuit breaker for over-current protection The SF8RM is designed to protect equipment against power surges & electrical noise whilst providing a convenient combination of power outlets to suit most applications. A unique mounting system allows mounting in many different modes to suit crowded racks. Even if no rack space exists, the units may be mounted externally on the front or rear of the rack. For horizontal mounting, the units require a single 1RU rack space for installation. The unit may also be flush mounted to either side of a rack or cabinet. Technical Specifications SF8RM Current rating 10A total Configuration Single-phase, L/N/E. Surge Protection Category AS/NZS1768-2007 Category B Primary protection modes L-N, L-E, & N-E Secondary protection modes L-N, L-E, & N-E Surge rating (8/20uS L-N) 22.5kA Let-through voltage < 700V@ 3kA Overvoltage withstand 300VRMS Filter type Low Q/low C filter providing differential & common-mode filtering. Attenuation > 50dB above 1MHz. Voltage drop Less than 3V at rated load. Input connection Approved power cord with Australian 10A plug Output connections Australian 3 pin 10A (x8). Enclosure Steel, powder coated, black. Dimensions (without brackets) 441 x 120 x 44 mm (W x D x H) Weight 1.2kg Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. 40 Eaton Surge Protection Eaton Surge Protection 41 Class / Category ANSI/IEEE C62.41 III / A SSF10I / 15I II / B & C I & II / A,B,C,D PPFI 3 3 1 1 1 3 3 III / A ECAT6PPC SF8RM III / A Rackmount Power Filters III / A III / A EMTJC6 ERAK16EC5 Cord - - - Dataline Network Transient Protectors II / B & C MSFXX3I II / B DSFI MSFXX1I II / B CSFI Hardwired Surge Power Filters II / B, C MSDI 1 II / B, C II / B, C SPD120I SPD3N / GI - II / B SPDT60-255 - 1 II / B II / B, C SPD50NGI 1 II / B, C Cord Cord Cord Connection/ Phases SPDV60-300 SPDQM1 Hardwired Surge Diverters III / A III / A POD POD+ Portable Surge Power Filters Surge Protection Product N/A N/A N/A N/A CEi = 30kA/ph DEi = 45kA/ph EEi = 90kA/ph 60kA/ph 60kA 15kA 10kA 75kA/ph 20kA 50kA 40kA 30kA 50kA (N-E) 30kA 10kA 3kA 3kA Nominal Surge Current (In) L-N x 20 hits 22.5kA 132A 97A 132A/port CEi = 80kA/ph DEi = 120kA/ph EEi = 240kA/ph 160kA/ph 160kA 50kA 25kA 200kA/ph 40kA/ph 100kA 60kA 60kA 70kA (N-E) 60kA 25kA 40kA 40kA Max Surge Current (max) L-N 10A N/A N/A N/A 100A, 160A, 200A, 315A, 400A 40A or 63A 40A or 63A 32A 25A N/A N/A N/A N/A N/A N/A N/A 10A / 15A 10A 10A Max Load Current For use in commercial, industrial & domestic applications Quick Product Selection Guide L-N, L-E, N-E W-W, W-E W-W, W-E W-W, W-E L-N, N-E L-N, L-E, N-E L-N, L-E, N-E L-N, L-E, N-E L-N, L-E, N-E L-N, L-E, N-E L-N, N-E or L-N, L-E L-N or L-E N-E L-N N-E L-N L-N, L-E, N-E L-N, L-E, N-E L-N, L-E, N-E Protective Modes 2 1 1 1/port 2 2 2 2 2 1 1 1 1 1 1 1 2 2 2 Shunt Diversion Stages 19" Rack Portable Portable 19" Rack Surface Surface Surface Surface DIN Rail Surface DIN Rail DIN Rail DIN DIN Cable - Portable Portable Portable Mounting No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes No No CE Mark Applicable Y/N Yes N/A N/A N/A Yes Yes Yes Yes Yes No No No No No No No Yes Yes Yes Power Filtering Y/N Yes No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Status Indicators Y/N No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No No Remote Alarm Y/N 441x120x44mm, 1.2kg 91x37x23mm, 0.1kg 91x37x23mm, 0.1kg 483x98x20mm, 0.64kg 100-250A = 600 x 200 x 800mm, 50-60kg 315A & 400A = 800 x 400 x 1000mm, 100kg 370x160x560mm, 14kg 210x160x560mm, 9kg 140x50x270mm, 1.5kg 70x68x90mm, 200g 370x160x560mm, 14kg 70x68x90mm, 200g 70x68x90mm, 200g 18x65x97mm, 0.1kg 18x65x97mm, 0.1kg 60x15x15mm, 0.15kg 25x71x93mm, 0.3kg 150x140x50mm, 500g 383x130x42mm, 1kg 338x130x42mm, 800g Dimensions & Weight UPS & Surge Filter Selection Guide UPS Model Rating Main (Rectifier) Input Surge Filter Bypass Input Surge Filter PW51251000A 1kVA SSF10I NA PW51251500A 1.5kVA SSF10I NA PW51252000A 2kVA SSF10I NA PW51252200A 2.2kVA SSF10I NA PW5130i1250-XL2U 1.25kVA SSF10I NA PW5130i1750-XL2U 1.75kVA SSF10I NA PW5130i2500-XL2U 2.5kVA SSF15I NA PW5130i3000-XL2U 3kVA SSF15I NA Powerware 9120 Dual or Single Input UPS, for single input use Rectifier input rating PW91206000A 6kVA DSFI DSFI PW9130G700T-XLAU 0.7kVA SSF10I plug/play, or CSFI/DSFI Hardwired NA PW9130G1000T-XLAU 1kVA SSF10I plug/play, or CSFI/DSFI Hardwired NA PW9130G1500T-XLAU 1.5kVA SSF10I plug/play, or CSFI/DSFI Hardwired NA PW9130G2000T-XLAU 2kVA SSF10I plug/play, or CSFI/DSFI Hardwired NA PW9130G3000T-XLAU 3kVA SSF15I plug/play, or CSFI/DSFI Hardwired NA PW9130G1000R-XL2UAU 1kVA SSF10I plug/play, or CSFI/DSFI Hardwired NA PW9130G2000R-XL2UAU 2kVA SSF10I plug/play, or CSFI/DSFI Hardwired NA PW9130G3000R-XL2UAU 3kVA SSF15I plug/play, or CSFI/DSFI Hardwired NA PW9135G6000-XL3U 6kVA DSFI NA Powerware 9140 Dual or Single Input UPS, for single input use Rectifier input rating PW91407500HW 7.5kVA DSFI DSFI PW914010000HW 10kVA DSFI DSFI Powerware 5125 Powerware 5130 Powerware 9130 Powerware 9135 Powerware 9155S Dual or Single Input UPS, for single input use Rectifier input rating PW91558iSxx 8kVA MSF401CCMI MSF401CCMI PW915510iSxx 10kVA MSF631CCMI MSF631CCMI Powerware 9155N Dual Input UPS, 3 Phase Rectifier, 1 Phase Bypass PW91558iNxx 8kVA MSF403CCMI MSF401CCMI PW915510iNxx 10kVA MSF403CCMI MSF631CCMI PW915512iNxx 12kVA MSF403CCMI MSF631CCMI PW915515iNxx 15kVA MSF403CCMI MSF631CCMI PW915520iNxx 20kVA MSF403CCMI Contact Eaton PW915530iNxx 30kVA MSF403CCMI Contact Eaton Powerware 9355 Dual or Single Input UPS, for single input use Rectifier input rating 93558Nxx 8kVA MSF403CCMI MSF403CCMI 935510Nxx 10kVA MSF403CCMI MSF403CCMI 935512Nxx 12kVA MSF403CCMI MSF403CCMI 935515Nxx 15kVA MSF403CCMI MSF403CCMI 935520Nxx 20kVA MSF633CCMI MSF403CCMI 935530Nxx 30kVA MSF633CCMI MSF633CCMI 935540Nxx 40kVA PPF1003CEi MSF633CCMI Powerware 9390 Dual or Single Input UPS, for single input use Rectifier input rating PW939040N 40kVA PPF1003CEi MSF633CCMI PW939060U 60kVA PPF1003CEi PPF1003CEi PW939080N 80kVA PPF1603CEi PPF1603CEi PW9390100U 100kVA PPF2003CEi PPF1603CEi PW9390120N 120kVA PPF3003CEi PPF2003CEi PW9390120U 120kVA PPF3003CEi PPF2003CEi PW9390160N 160kVA PPF4003CEi PPF3003CEi For UPS ratings above 160 kVA please contact your Eaton representative for further information. 42 Eaton Surge Protection Quickmov™ Fast, Safe & Dependable Safety and Performance. Eaton’s Quickmov™ is a fully integrated Surge Protection Device (SPD), designed for stand-alone mounting or to plug straight into a Quicklag™ loadcentre, connecting to the chassis busbar for the lowest source impedance. ideal for primary protection in main switchboards and can be used in conjunction with an Eaton Neutral-Earth arrestor for distribution boards remote from the M.E.N point. Quickmov™ combines surge diversion with fail-safe protection to Quickmov™ employs advanced deliver unsurpassed levels of safety MOV technology with embedded thermal protection housed in a dual and performance. barrier flame retardant case to provide optimum surge protection performance. With a 60kA surge suppression rating, Quickmov™ is Eaton Surge Protection 43 Eaton Corporation is a diversified power management company ranked among the largest Fortune 500 companies. The electrical group is Eaton’s largest division & is a global leader in electrical control, power distribution, power quality, automation, & monitoring products and services. Eaton’s global electrical brands, including Cutler-Hammer®, MGE Office Protection Systems™, Powerware®, Holec®, MEM®, Santak and Moeller, provide customer-driven PowerChain Management® solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical & OEM markets worldwide. PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle. With Eaton’s distribution, generation & power quality equipment, full-scale engineering services & information management systems, the power system is positioned to deliver powerful results: greater reliability, operating cost efficiencies, effective use of capital, enhanced safety & risk mitigation. Eaton Industries Pty. Ltd. Electrical Sector 10 Kent Road Mascot, NSW 2020 Australia 1300 3 EATON (1300 3 332 866) www.eaton.com/powerquality www.eatonelectric.com.au PowerChain Management is a trademark of Eaton Corporation. All other trademarks are property of their respective owners. ©2010 Eaton Corporation All Rights Reserved Printed in AUS 077PQ