* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Technology Selection - Sunrator Technologies LLP
Telecommunications engineering wikipedia , lookup
Electrical engineering wikipedia , lookup
Opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power engineering wikipedia , lookup
Ground (electricity) wikipedia , lookup
Shockley–Queisser limit wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Distributed generation wikipedia , lookup
Distribution management system wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
Earthing system wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Designing Solar PV Systems ( Utility Scale) Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar PV Systems (Rooftops) Module 4: Designing Solar PV Systems (Utility Scale ) Module 5: Financial Analysis Module 6: DPR (Detailed Project Report) & EPC Module 7: The present Solar industry scenario and the future THE PLANT Technology Selection Layout and Shading The Plant Design Design Optimization Electrical Design Technology Selection – Modules The following aspects should be kept in mind while choosing modules: High efficiency modules require less land than low efficiency ones. Different spectral response for different technologies. Temperature coefficient of power plays an important role in hot climates. Degradation properties should be carefully understood. Manufacturer’s warranty period must be looked upon. Cost (Rs/Wp), lifetime and maximum system voltage should be considered. Technology Selection – Inverters Size plays a very important role for the inverter connection concept. For utility-scale power plants, central inverters are preferred. High efficiency A wide MPP range The grid code which affects the inverter sizing and technology, is required for controlling the reactive power. Technology Selection – Inverters (contd.) Inverters with high reliability has low downtime including low maintenance and repair costs. For different module specification, string or multi-string inverters are recommended for minimizing the mismatch loses. For sites with different shading conditions or orientations, string inverters are more suitable. Criteria like plant monitoring, data logging and remote control must be taken into account. Technology Selection – Mounting Structures A good quality mounting structure, mostly fabricated from steel or aluminum is expected to have the following: • Extensive testing for withstanding the load conditions at the site. • Allow field adjustments that may reduce installation time and compensate for inaccuracies in placement of foundations. • Thermal expansion using expansion joints where necessary in long sections for modules not getting unduly stressed. • Customized structures specific to engineering challenges. Layout and Shading – Tilt Angle & Orientation To generate the maximum energy, the modules should be tilted at an angle so that the sun hits it at a perpendicular angle at all times. Optimum orientation – True South East orientation-Receive sunlight only before noon. West orientation-Receive sunlight only after noon. Layout and Shading – Inter Row Spacing Image: Schletter Gmbh α, the shading limit angle is the solar elevation angle beyond which there is no inter-row shading on the modules. If the elevation of the sun is lower than α then a proportion of the module will be shaded. Alongside, there will be an associated loss in energy yield. The shading limit angle may be reduced either by reducing the tilt angle β or increasing the row pitch d. Electrical Design DC System – PV array design • Maximum number of modules in a string Voc (module) x Nmax < Vmax (Inverter, DC) • Minimum number of modules in a string Vmpp (module) x Nmin > Vmpp (Inverter, min) •Voltage Optimization • Number of Strings Electrical Design DC System – Inverter Sizing Following factors must be considered when sizing an inverter: • The maximum Voc in the coldest daytime temperature must be less than the inverter maximum DC input voltage. • The inverter must be able to safely withstand the maximum array current. •The minimum Voc in the hottest daytime temperature must be greater than the inverter DC turn-off voltage. • The maximum inverter DC current must be greater than the PV array/s current. • The inverter MPP range must include PV array MPP points at different temperatures. Electrical Design DC System – Cable Selection and Sizing Following factors must be considered when sizing cables: • The cable voltage rating • The current carrying capacity of the cable • The minimization of cable losses Electrical Design AC System – AC Cabling Following factors must be considered when designing the cabling: • The cable must be rated for the maximum expected voltage. • The conductor should be able to pass the operating and short circuit currents safely. • The conductor should be sized appropriately to ensure that losses produced by the cable are within acceptable limits. • The conductors should be sized to avoid voltage drop outside statutory limits and equipment performance. • Insulation should be adequate for the environment of installation. • Either copper or aluminium conductors should be chosen. • Number of cores (single or multiple) should be chosen accordingly. • Earthing should be properly designed. Electrical Design AC System – AC Switchgear Considerations must be given to switchgears which are : • In accordance with IEC and national standards. • Options for secured off/ earth positions. • Rated for operational, short circuit currents and correct operational voltage. • Remote switching capability for HV switchgear. • Suitable earthing. Electrical Design AC System – Transformer selection and sizing Transformers are required for providing suitable voltage levels for transmission across the site and export to the grid. Transformers can also loose energy through magnetising currents in the core. These losses are known as iron and cooper losses. Minimising the losses will increase the energy supplied to the grid and thus enhance the revenue of the power plant. Electrical Design AC System – Substation Metering: To measure the export of power, tariff metering is required. The meter provided at the substation or at the point of connection to the grid has inputs from the current as well as voltage transformer. Data Monitoring / SCADA Auxiliary Equipments: LV power supplies, diesel generators, lighting, water supplies, drainage, safety systems etc. Electrical Design AC System – Lighting and Surge protection • Array frame lighting • System earthing (DC conductor earthing) • Inverter earthing • Lightning and surge protection. Optimizing the system design • Reducing the system losses for better plant performance. • Balancing annual yield and economic return. • Proper technology selection and prior simulation for better analysis and optimization. • Thorough technical due diligence for mitigating performance issues. Thank You!! Passionate About Solar? Feel Free To Get In Touch [email protected] 011-41605551