Download SELECTRONIC™ FloWise® EXPOSED 1.6/1.1 GPF DUAL FLUSH

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Power engineering wikipedia , lookup

History of electric power transmission wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
SELECTRONIC™ FloWise® EXPOSED
1.6/1.1 GPF DUAL FLUSH TOILET FLUSH VALVE
HARD-WIRED AC POWERED, SENSOR OPERATED
MODEL NUMBER:
❑ 6067.761.002 HARD-WIRED AC POWERED:
Includes UL-approved Hard-Wired AC transformer
(electrical box by others). 11-1/2" rough-in
❑ 6068.761.002 MULTI-AC POWERED:
Includes 10' extension cable. One transformer (sold
separately) can operate up to 15 faucets and/or flush
valves. 11-1/2" rough-in
OPERATING PRESSURE:
25 psi (flowing)-80 psi (static)
GENERAL DESCRIPTION:
Exposed, Hard-wired AC Powered, Sensor Operated
Selectronic™ Water Closet Flush Valve for
floor-mounted or wall-hung 1-1/2" top spud bowls.
Inlet includes 1" I.P.S. angle stop with back-flow
protection, vandal-resistant cap, sweat solder kit,
cover tube and wall flange.
Outlet includes 1-1/2" vacuum breaker, spud coupling
and flange.
FLOW REQUIREMENT:
25 gpm (94.6 L/min.)
ACCESSORIES:
• Cast wall flanges (1" & 1-1/2")
• Solid ring pipe supports (2-1/2" & 6" C-E)
• Split ring pipe supports (2-1/2" & 6" C-E)
PRODUCT FEATURES:
• Light flush (1.1 gpf: 30% water savings) if user is in
detection zone for 60 seconds or less
• Standard flush (1.6 gpf) if user is in detection zone for
more than 60 seconds
• Electronic flush valve with Selectronic™ proximity system
for “Hands Free” operation
• Includes UL approved hard-wired AC transformer
• Input Voltage: 100 - 250 VAC, 50 / 60 Hz. Output Voltage:
6 VDC.
• Self-Cleaning Piston operation with integral wiper spring
prevents clogging and reduces maintenance
• Piston operation delivers superior flush accuracy and
repeatability
• Adjustable tailpiece
• Chemical resistant EPDM seals are unaffected by
chloramines and ammonia
• Valve remains closed and does not need to be reset after
loss of power or water pressure
• Fully Mechanical Manual Override Button can flush toilet
during a power outage
• Vandal-resistant metal cover plate (for 2-gang electric box
supplied by others) with no visible fasteners
• Sensor & electronic controls are fully enclosed and water
resistant
• Range can be adjusted manually or by remote control
• Sanitary Flush - Valve automatically flushes after 24
hours of non-use to clean fixture & maintain trap seal
• No external volume adjustment
• 5 second Arming Delay prevents unintentional flushing
• 3-second Flush Delay
• Can be installed left or right-handed
TYPICAL WATER CLOSET INSTALLATION:
AFWALL™ TOILET SHOWN
FINISHED WALL
57mm (2-1/4")137mm (5-3/8")
86mm
(3-3/8")
160mm
(6-1/4")
COVER &
ELECTRICAL
BOX
409mm
(16-1/8")
-C-L-
293mm
(11-1/2")
SUPPLY
DN 25mm
(1" I.P.S.)
CRITICAL
LEVEL
SEE ROUGH-IN
ON BACK
115mm - 134mm
(4-1/2" - 5-1/4")
FINISHED
FLOOR
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND
USABLE BUILDING FACILITIES-CHECK LOCAL CODES
RECOMMENDED SPECIFICATION:
Electronic proximity infrared sensor activated toilet flush valve shall feature self-cleaning piston valve. Includes a UL listed hard-wired power
supply that provides 6 VDC power to run system. Flush volume is determined by amount of time user is in detection zone. 60 seconds or less:
1.1 gpf/4.2 Lpf. More than 60 seconds: 1.6 gpf/6.0 Lpf. Includes a fully mechanical manual over-ride that can provide a complete flush without
power. Includes cast brass valve body and metal cover with chrome finish and vandal resistant stop cap. Angle stop with back-flow protection
and vacuum breaker included. Flush valve shall be American Standard Model # 606_.761.002.
© 2016 AS America Inc.
Revised 5/16
SELECTRONIC™ FloWise® EXPOSED
1.6/1.1 GPF DUAL FLUSH TOILET FLUSH VALVE
HARD-WIRED AC POWERED, SENSOR OPERATED
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Roughing-in Dimensions
180 ˚
160mm
(6-1/4)
72mm
(2-7/8)
MANUAL
OVERRIDE
BUTTON
2-GANG ELECTRICAL
BOX BY OTHERS
160mm
(6-1/4)
DETECTION ZONE
400mm-800mm
(15-3/4 TO 31-1/2)
FINISHED WALL
15˚
116mm
(4-5/8)
*CRITICAL
LEVEL
293mm
(11-1/2)
51mm (2") HOLE
FOR CONDUIT
45 ˚
305mm
(12 MAX.)
86mm
(3-3/8)
SUPPLY
DN 25mm
(1¨ I.P.S.)
-C-L-
115mm-134mm
(4-1/2 TO 5-1/4)
409mm
(16-1/8)
57mm (2-1/4) 137mm (5-3/8)
-C-L152mm
(6 MIN.)
FOR 1-1/2" TOP
SPUD FIXTURES
TOP OF
FIXTURE
Right or Left Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6 " min. (152mm) above fixture.
Consult Codes for details.
© 2016 AS America Inc.
Revised 5/16