* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download DPPS - Defense Protected Power Systems, LLC
Survey
Document related concepts
Grid energy storage wikipedia , lookup
Standby power wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power over Ethernet wikipedia , lookup
Power factor wikipedia , lookup
Audio power wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electric power system wikipedia , lookup
Wireless power transfer wikipedia , lookup
Rectiverter wikipedia , lookup
Electrification wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power electronics wikipedia , lookup
History of electric power transmission wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Transcript
The Power To Protect Server Center Presentation Defense Protected Power Systems, LLC 425 Huehl Road Suite 6B Northbrook, IL 60062 847-480-5510 X33 Gary Elkins Cell 847-226-3579 Protective Technology DPPS is a global provider of revolutionary Power Conditioning products. Our products provide the only effective solutions in total protection against Surges, Spikes, Transients, Power Factor Correction, Voltage Distortion, In Rush Currents, and a multitude of other power related problems including Solar Storms. Clients include The Department Of Defense, The United States Army, The Centers for Disease Control, Ford Motor Company, McDonald’s, Taco Bell, Steak N Shake and more. Our technology is patented and we are proud to present an overview of how we are prepared to preserve critical data loss, save energy, and protect systems within the retail sector. DPPS Provides Guaranteed Safe Power No-Failure Design Outperforms Isolation Transformers/Surge Suppressors Costs virtually nothing to use, uses less than 1Watt Cleans, Filters and Corrects AC ground Unlimited Joules of Energy Protection Why DPPS? Other Industry Products Can Actually Be Damaging to Electronics (Surge Suppressors, Power strips etc..) How? Restriction of Voltage = Increase in Current Damaging Let-Through Energy (fails to keep circuits energized) Excess Energy Driven to Ground Pollutes Ground Prone to Failure No Conditioning in Steady State Why DPPS? DPPS Products Are Designed Specifically to Protect Electronic Devices Provides Isolated Ground / Solid Ground Reference •No Reboots No Energy Driven to Ground •No Chip Failures •Eliminates Surge Current Impacts Reduces Heat 6-10 degrees Fahrenheit •Reduces Current Draw up to 14% Harmonic Attenuation up to 40% •Increased Power Factor up to 30% •Highly Efficient, using virtually no Electricity to perform •Emits no EMI (electromagnetic interference) or RFI (radio frequency interference) •Noise Attenuation effective range 100Hz-2GHz Problems & Solutions Bi-Directional Hi-Frequency Filtering Allows the DPPS systems to filter both the incoming power from the outlet and from the system back to the outlet. Why is this important? It filters High Frequency generated by the system and High Frequency carried from the outside power source to the systems. Allows the DPPS products to positively remove any signals generated by systems i.e. (Computers, Registers, Kiosks, and Point of Sale devices) from being introduced on the ground line of the building, which supplies the power. Why is this important? Eliminates the ability to intercept data from electronic systems, which are protected by DPPS technology. Critical data is protected from interference. Problems & Solutions Bi Directional Harmonic Filtering – Harmonics create heat, and heat is the cause of significant system failure. By filtering the harmonics generated by the incoming power source as well as the harmonics generated by each individual system you are reducing the overall heat signature of each system utilizing DPPS technology. ◦ By reducing the heat of each individual system you can reduce the ambient temperature in the operating environment by as much as 14%. This effectively reduces energy cost associated with cooling that environment. ◦ Additionally it will reduce the overall amount of distortion associated with harmonics. The end result is a cooler environment, less energy required to keep mission critical infrastructure cool, and better clarity of the equipment, monitoring equipment and system monitors. Problems & Solutions Power Conditioning and Power Factor Correction – This provides for a consistent pure level of power provided to your systems all the time, period! ◦ So how does this assist in system performance? The platform or system(s), which utilizes the DPPS technology will operate consistently at its optimal level because it does not need to counter-act the effects of less than pure power. Additionally it can increase the effective range of radio platforms by increase the power quality that is introduced into that platform. Problems & Solutions Spike, Transient and EMP protection – The DPPS technology prevents, the transmission of electrical spikes (including solar flares) and transients from both facility power and system introduced transients. ◦ Each time a transformer turns on, the cooling fan for a CPU, the cooling fan for the laptop, desktop or server, or a printer warms up, it creates a transient on the ground line. Those transients eat away at anything with a microprocessor, circuit board, RAM, and hard-drives. ◦ The DPPS technology removes all transients from your systems. ◦ Results – By eliminating transients you are effectively increasing the life cycle of any system that uses DPPS technology. You are reducing system down time in case of complete power loss. You are reducing maintenance and troubleshooting hours looking for repairing systems that do not recover. The Green Side Extended life cycle • Reduced heat levels by up to 10 degrees Fahrenheit Reduced cooling requirements • Reduced energy requirements by up to 14% • Reduces system downtime and maintenance troubleshooting Less landfill waste cooler environments & extended life cycle RP24004 Defense Protected Power Systems, LLC Sentry Line Product Line Introduction RP6000 Confidential, Copyright 2011 DPPS, LLC. VA Sentry Data Center product line offers a complete range of solutions RP24004 120V 20 Amp RP6000 220V 30 Amp Single Phase RP7000 208 60 Amp 3-Phase Delta Confidential, Copyright 2011 DPPS, LLC The RP24004 provides tangible, immediate benefits Lowers cost Reduced equipment power usage up to 14% Lowers electronic heat output up to 10 degrees Fahrenheit at the rack, resulting in lower cooling costs Improves stability Extends the life of high-value electronics by eliminating harmful transients, thereby reducing maintenance costs Blocks 99.999% of all damaging energy by covering line, neutral and ground – Industry leading compliance with Third Generation Surge requirements from Underwriters Laboratories Confidential, Copyright 2011 DPPS, LLC VA Sentry by DPPS outperforms the most popular standard power strip solutions Feature Comparison VA Sentry RP6000AX HP 24A-HV PDU Shark CB-12H2L630 Surge and Noise filtration on all paths, including Ground Power Factor Correction Reduced heat output as a function of reduced harmonics Reduced energy requirements as a function of reduced harmonics Guards against Ground Faulting Web-enabled Power Monitoring and Alerting Visual Power Meter Individual strip/stick power switches on core for maintenance UL 60950-1 IT Equipment Certified Confidential, Copyright 2011 DPPS, LLC. Dell DPN06T858 & DPN08T287 Glossary of Electrical Terms Energy – Energy consists of two elements: voltage and current. Leveler’s electrical power solutions focus on both elements equally Harmonics – A Harmonic is a whole-number multiple of the main (fundamental) frequency of electricity being delivered. For example, if 60Hz is the main frequency being delivered, then harmonics can exist at 120Hz, 180Hz, 240Hz, and son on. When energy potential of flow is sent out of phase, it remains on the distribution system as unusable energy that negatively affects the further delivery of usable energy. Equipment sensitive to current must deal with harmonics, usually releasing them either as heat or magnetism. Phase – A phase is one cycle of electricity relative to another cycle. Phases are used to put more then one supply of 60Hz electricity on the same wire to improve the efficiency of electrical distribution. Transient – It’s a fast-moving energy (measured in microseconds up to 1 millisecond) that results from sudden load changes or lightning. Typically, transients are disruptive, rather than destructive, because they tend to cause data corruption or interruption. Surge – Similar to a transient but lasting much longer (measured in milliseconds). Surges carry catastrophic energy (voltage and current) that can destroy electronics. Distortion – An unexpected change of a waveform or shape for the voltage and/ or current signals is distortion. Distortion is typically undesirable as it limits capacity or decreases performance Power Factor – The ratio of True Power (Watts) to Apparent Power (Volt Amps). When the current and voltage are in sync, the Power Factor is 1.0. Power Factor has a potential range of 0 to 1, but is usually expressed in tenths (0.57, 0.70, etc). Most electronic devices have a Power Factor below 0.60. Destructive Units – Volts x Amps x Seconds, used to accurately represent total energy in a surge event Confidential, Copyright 2011 DPPS, LLC DPPS At Your Service Defense Protected Power Systems, LLC. 425 Huehl Road, Bldg. 6B Northbrook, Illinois 60062 Gary Elkins 847-226-3579 James Sheaffer 719-213-9025