Download Control Units MAGTRONIC Loop Detector MID 1 E - 800

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Crystal radio wikipedia , lookup

Amateur radio repeater wikipedia , lookup

Cavity magnetron wikipedia , lookup

Spectrum analyzer wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Power electronics wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Opto-isolator wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Radio direction finder wikipedia , lookup

Mathematics of radio engineering wikipedia , lookup

Direction finding wikipedia , lookup

Superheterodyne receiver wikipedia , lookup

Index of electronics articles wikipedia , lookup

Rectiverter wikipedia , lookup

Radio transmitter design wikipedia , lookup

Regenerative circuit wikipedia , lookup

Wien bridge oscillator wikipedia , lookup

Heterodyne wikipedia , lookup

Loop antenna wikipedia , lookup

Bellini–Tosi direction finder wikipedia , lookup

Phase-locked loop wikipedia , lookup

Transcript
Control Units
MAGTRONIC
Loop Detector
MID 1 E - 800
Technical data
Power supply
:
Power consumption:
Operating temperature:
Humidity
Loop inductivity:
Frequency range:
Sensitivity (df / f):
Loop lead length:
Relays:
Type
MID 1E
V
W
24 V AC/DC, +/- 10%
max. 1.5 W
-20 ° – +70° C°
max. 95%
25 – 800 uH
30 – 130 kHz
0.01% – 0.65%
max. 820 ft.
1 presence relay
1 pulse relay
24 V AC/DC
plastic housing
for C-rail
with 2x 3-pin. clamps
3 1/8” x 1” x 3 1/2”
feet
Switch voltage:
Housing
Dimensions: (L x W x H)
Protection
IP 40
A reset with calibration can be effected by
changing the hold time setting.
The MID Detektor
The microprocessor-controlled, single channel MID detector can detect vehicles without
contact. Via the connected induction loop
all sorts of metallic vehicles like cars, trucks,
buses, fork lifts and even bicycles are
easily detected.
Applications:
- barrier controls
- parking and traffic technology
- door and gate controls
Operation principle of the presence
relay
Hold time and Reset
The hold time can be adjusted with DIPswitch h.
At the completion of the hold time it will
be displayed “free loop” and the detector calibrates automatically. The hold time starts
with the occupation of the loop.
Setting options
Sensitivity
580 US, 5185/ 0/ 04.02
The setting of the sensitivity is adjustable
and gives the frequency deviation which a
vehicle must produce for setting the output
of the detector. The sensitivity can be adjusted in 4 steps with the two DIP-switches s
on top of the front panel.
Frequency adjustment
An automatic calibration of the loop frequency will be done by the detector after
switch-on of the power supply. In case of
short power cuts < 0,1 s there is no calibration.
Info number: MF 5185/US
The detector has one relay for presence output and another relay for pulse output each
with a potential free contact. The operation
principle of the pesence relay can be changed
with the DIP-switch r.
The operation frequency of the detector can
be adjusted in two steps by the 3-pole
connection jack in the front panel. The
permissible frequency range is 30 kHz to
130 kHz. The frequency depends on the loop
inductivity (depending itself on: loop geometry, number of loop turns and loop lead)
and the adjusted frequency step.
Magnetic Automation Corp. 3160 Murrell Road, Rockledge, FL 32955, USA Phone (321) 6358585 Telefax (321) 6359449 [email protected]
Outputs and LED
Contact mode of the relays
The following table shows the state of the
relay contacts depending on the detector
mode.
Output of the loop frequency
Approx. 1 s after calibration of the detector
the loop frequency will be displayed by pulse
signals of the green LED. Firstly the 10 kHz
position of the frequency value will be indicated. For every 10kHz frequency value the
green LED flashes once. After a break of 1 sec
the 1 kHz position is displayed in the same
manner. If there is value of ’O’ in the 1 kHz
position there will be displayed 10 flashes.
The flashes of the 1 kHz position are a little
bit shorter than for the 10 kHz position.
In case of a loop failure the detector checks
the loop condition cyclically and continues
after elimination.
LED-signals
24 V=/~
0 V / GND
The green LED signals that the detector is
ready for operation. Via the red LED, the activation of the relays output is announced
depending on the occupation status of the
loop.
display
sensitivity
holding time
relay operation principle
frequency high
frequency low
MID1E
presence signal
pulse signal
Connections
Subject to technical modifications.http://www.magnetic-group.com
Magnetic Automation Corp. 3160 Murrell Road, Rockledge, FL 32955, USA Phone (321) 6358585 Telefax (321) 6359449 [email protected]
Control Units
MAGTRONIC
Loop Detector
MID 2 E - 800
Technical Data
Type
MID 2 E
Power supply:
Power consumption:
Operating temperature:
Humidity
Loop inductivity:
Frequency range:
Sensitivity (df / f):
Loop lead length:
Relays:
Switch voltage:
Housing
V
W
Dimensions: (h x w x d)
mm
24 V AC/DC, +/- 10%
max. 1.5 W
-20° bis +70° C
max. 95%, o
25 – 800 μH
30 – 130 kHz
0,01% – 0,65%
max. 250 m
1 presence relay / 1 pulse relay
24 V AC/DC
plastic housing
for C-rail
with 2 x 3-pin clamps
79 x 22.5 x 90 mm
IP 40
Protection
The MID Detektor
Operating principle of the relays
The microprocessor-controlled, dual
channel MID detector can detect vehicles
without contact. Via the connected induction loop all sorts of metallic vehicles like
cars, trucks, buses, fork lifts and even bicycles are easily detected.
In standard configuration both relays operate in the closed-circuit current mode
where the break contacts are led onto
the connections.
The operating principle of the relays can be
changed according to the following table.
For this modification, the detector housing
must be opened carefully.
Applications:
- barrier controls
- parking and traffic technology
- door and gate controls
580E, 5186/0/02.05
Setting options
Sensitivity
The setting of the sensitivity calls the electronics to a value of frequency deviation
which a vehicle must produce for setting
the output of the detector. The sensitivity
can be adjusted for each channel in 4 steps
with DIP-switches on top of the front
panel.
Info no.: MF 5186/E
Subject to technical modifications.
Hold time and Reset
The hold time can be adjusted with DIPswitch 6. At the completion of hold time it
will be displayed "free loop" and the
detector calibrates automatically. The hold
time starts with the occupation of the
loop.
A reset with calibration can be effected
by changing the hold time setting.
Attention!
Static sensitve components are on the
board. During works on the open device
precautions are to be taken. Do not touch
components or connections on the board.
There is no guarantee in case of defects by
inappropriate processing!
An automatic calibration of the loop frequency starts after power on. In case of
short power cuts <0,1s there is no calibration.
Magnetic Autocontrol GmbH
Grienmatt 20
D-79650 Schopfheim
Phone: +49 7622 / 695-5
Fax:
+49 7622 / 695- 602
e-mail: [email protected]
http://www.ac-magnetic.com
The direction pulse signal is normally used
for counting systems and the direction
pulse signal for gate and barrier controls.
At the examples in the next column the
operation principle of the direction logic is
explained. The direction signal is output
via the relay of the first covered loop i.e.
signaling occurs in the case of driving
direction 1–>2 via relay 1 and in the case of
driving direction 2–>1 via relay 2.
In case of failure of one loop during direction output mode the detector operate in
presence output mode independed of the
setting of DIP-switch 8.
Frequency adjustment
The operation frequency of the detector
can be adjusted in two steps with DIPswitch 5.
The permissible frequency range is 30kHz
to 130kHz. The frequency depends on the
loop inductivity (depending itself on: loop
geometry, number of loop turns and loop
lead) and the adjusted frequency step.
Output mode
Presence output mode
For presence output mode DIP-switch 7 is
to be set to the left positon. In this mode
relay 1 signals presence on loop 1. The function of relay 2 can be set by DIP-switch 8.
Direction output mode
For direction output mode DIP-switch 7 is
to be set to the right positon. Two direction
logics are supported depending on DIPswitch 8.
Magnetic Automation Corp.
3160 Murrell Road
Rockledge, FL 32955, USA
Phone: (+1) 321 / 635 85 85
eMail: [email protected]
Outputs and LED
LED display
The green LED signals that the detector is
ready for operation. Via the red LED, the
activation of the relays output is displayed
depending on the occupation status of the
loop.
LED green
loop
control
Led red
loop
condition
detector funktion
off
off
power off
flashing
off
calibration or output
of frequenty
on
off
detector ready for operation,
free loop
on
on
det. ready for operation,
convered loop
off
on
loop failure
Output of loop frequency
Approx. 1 sec. after calibration of the
detector the loop frequency will be displayed by pulse signals of the green LED. Firstly
the 10 kHz position of the frequency value
will be indicated. For every 10 kHz frequency value the green LED flashes once. After a
break of 1sec the 1kHz position is displayed
in the same manner. If there is value of '0'
in the 1kHz position there will be displayed
10 flashes. The flashes for 1 kHz position
are a little bit shorter than for the 10 kHz
position.
Magnetic Automation Pty. Ltd.
19 Beverage Drive
Tullamarine, Victoria 3043, Australia
Phone: (+61) 3 / 93 30 10 33
eMail: [email protected]
Magnetic Control Systems
(Shanghai) Co. Ltd.
999 Ning-qiao Road, Bldg. 2W/1F
Pudong New Area
Shanghai 201206, China
Phone: (+86) 21 / 58 34 17 17
eMail: [email protected]
Magnetic Control Systems Sdn. Bhd.
No. 16, Jalan Kartunis U1/47
Temasya Ind.Park, Section U1
40150 Shah Alam, Selangor
Darul Ehsan, Malaysia
Phone: (+60) 3 / 5569 17 18
eMail: [email protected]
Magnetic Autocontrol Pvt. Ltd.,
„Sree Krishna Leela“
Apt.3, I Floor, II Main Road, R A Puram
Chennai- 600 028, India.
Phone: + 91 44 52111222
Fax:
+ 91 44 52111221
eMail: [email protected]