M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS Pole-Top/Pad Mount Digital Voltage Regulator Control, for metering, monitoring, and operational control for step-voltage Regulators shall be provided by a microprocessor-based package. The microprocessor-based package shall be suitable for Pole Top Mounted or Pad Mounted single-phase voltage regulators, as well as Substation single-phase voltage regulators. The control shall have the following minimum functional and behavioral attributes: CONTROL FUNCTIONS The control shall include the following features and can be used for pole-mounted or padmounted single-phase voltage regulators as well as substation installations where SCADA communications are desired. Automatic/Manual Control: The Control shall have user-selectable control on the front panel for Automatic or Manual operation. In addition, it shall have an option for SCADA command to change the Auto/Manual control state remotely. Automatic/Manual Switch Status: The control shall provide indication of the Automatic/Manual Switch status via the communication ports. Voltage Limits, Tap Position Limits, and Runback: The control shall have Overvoltage and Undervoltage limits that are independently adjustable from 95 V to 135 V in 0.1 V increments. It shall have user-settable Upper and Lower tap position limits, with tap position knowledge active. There shall be an option for an adjustable deadband (above the overvoltage limit) of 1 V to 4 V to set the runback limit. Position Tracking: The control shall have a means of accurately tracking tap position information that can be integrated into an Integrated Volt VAr Management (IVVM) system. Operations Counter: The control shall have a pre-settable counter that records the number of raise and lower operations and increments based on the counter configuration, as set by the user. The counter shall be able to store up to 999.999 operation counts without being affected by a loss of power supply. Resettable Operations Counter: The control shall have a second user-resettable software counter similar to the Operations Counter. Neutral Counter: The control shall have a pre-settable neutral counter that records the number of times the Neutral Input is energized. The counter shall be able to store up to 999.999 operation counts without being affected by a loss of power supply. Bandcenter and Bandwidth: The control shall have an adjustable bandcenter range from 100 V to135 V in 0.1 V increments. The bandwidth shall have an adjustable bandwidth range from 1 V to 10 V in 0.1 V increments. Line Drop Compensation: The control shall have R and X compensation adjustable from –24 V to +24 V in 1 V increments. There shall also be an option for Z compensation with the voltage raise adjustment range from 0 V to +24 V, in increments of 1 V. Time-Delay: The control shall have a Definite Time-Delay function adjustable from 1 second to 360 seconds, in 1-second increments and Inverse Time-Delay adjustable from 1 second to 360 seconds, in 1-second increments. Inter-Tap Time-Delay: The control shall have an Inter-Tap Time-Delay to introduce time-delay between tap operations when control is in sequential mode. The time-delay range shall be adjustable from 0 to 60 seconds in 1 second increments and require input from an operation Page 1 of 9 counter or seal-in circuit validating the tap change operation actually occurred before allowing tap change operation to the next step. Selectable Outputs: The control shall provide user-selectable continuous or pulsed outputs. When the output selection is in continuous mode, an output (raise or lower) signal runs the tapchanger until the voltage moves within the band setting. When pulsed output is selected and initiated, the pulse will continue until it reaches the programmed pulse time-out or a counter contact or motor hold input operates. The pulse length is programmable from 0.2 to 12 seconds, in increments of 0.1 second. Reverse Power Operation: The control shall be able to detect a power flow reversal automatically and determine the direction of power flow, the LTC tap position, and the magnitude of the reverse power voltage to the regulator. The operational choices shall include Ignore (does not use power direction to make control decisions), Block (remain in present tap position and stop operating as a controller), Regulate-in-Reverse (use power reversal as the new source side voltage and change LTC tap position accordingly), and Run-to-Neutral (change LTC taps to the neutral position). CT to VT Phasing Correction: The control shall provide CT to VT phasing correction adjustable from 0° to +330° in 30° increments. VT Ratio Correction: The control shall provide a means of VT correction from –15 V to +15 V in 0.1 V increments Normalizing Voltage: The control shall offer an option for a Normalizing Voltage Multiplier with a range of 0.80 to 1.20 to be applied to Meter-Out Voltage. This shall be displayed in real-time as Normalizing Voltage to allow the user to overcome differences in the ratio of the PT that the Load Voltage input is using versus the PT the end user or other metering methods are using. Voltage Reduction: The control shall have three independent steps of voltage reduction, each adjustable from 0% to 10% in 0.1% increments of the bandcenter set point. The Voltage Reduction function shall be capable of operating from the front panel or through contact inputs and disabled locally or remotely. SCADA REMOTE MANUAL CONTROL MODE: SCADA Remote Manual Mode: The SCADA Remote Manual Mode shall allow the integrated volt-VAr control (IVVC) algorithm residing at the Master Control Center of the SCADA computer or other Host computer to operate from SCADA signals received through wired or wireless communications media to command Regulator RAISE or LOWER operations. The voltage regulator control shall maintain an Overvoltage and Undervoltage Limit supervision to protect the “never to exceed” voltages set as standard by the local Public Utilities Commission and SCADA shall be allowed to make RAISE and LOWER commands as necessary when operating within those safety limits. The voltage regulator control shall provide a means to switch from Remote Mode to Automatic Mode if communications fail and continue to operate autonomously until communications are restored. The control shall provide contingency responses upon extended loss of communications. SCADA Remote Manual Mode - SCADA Heartbeat: A SCADA Heartbeat Remote Mode shall be provided as a means for the SCADA system to place the unit in Remote Operation and perform RAISE and LOWER operations as directed by a central control source. This mode shall have a timer, and as long as the Remote Timer setting in the control is refreshed by the SCADA system writing a timer value to a DNP Analog Output point, the control shall remain in Remote Manual Operation. If the timer reaches zero, the control shall revert to Local Automatic Operation. The Local Automatic Operation shall switch back to Remote Manual Operation when SCADA writes a valid timer value to the DNP Analog Output point. Page 2 of 9 SCADA REMOTE MANAGEMENT OF LOCAL AUTOMATIC CONTROL MODE: SCADA Remote Management of Local Automatic Control Mode: The voltage regulator control shall have the capability to allow Remote SCADA Management of Local Automatic voltage regulator control. In this way, the Centralized Control can monitor voltage regulator controls allowing them to operate autonomously and only controlling them directly when emergency situations arise. Management via SCADA or other Host computer capable of operating through wired or wireless communications media allows SCADA to effect control by either changing the local automatic control settings via analog signal or, by sending binary commands for direct RAISE and LOWER operations. Sending analog settings to the control and letting it operate based on its new marching orders instead of directing each RAISE and LOWER command conserves bandwidth considerably and thereby minimizes the communications burden and total cost of operation. This mode shall employ a SCADA heartbeat feature as described in SCADA Remote Manual Mode to return the unit to operation using its programmed settings instead of those the SCADA system was controlling by. COMMUNICATIONS The communication ports shall provide access to all features, including metering, software updates, and programming of all functions. This shall be accomplished using a modem or direct serial connection from any PC-compatible personal computer running the control’s Communications Software package or via SCADA communications software. Communications Ports: Communication ports shall be optionally available in the following forms: Ethernet 10/100 Mbps through a copper RJ-45 connection (100 Base-T) Ethernet 100Mbps Fiber Optic with ST connectors (100 Base-FX) Serial Ports with RS-485, ST or V-Pin Fiber Optics, or RS-232 Protocols: The control shall support the following standard protocols: DNP3.0 and MODBUS. The USB port shall utilize MODBUS for local interface communications. The Ethernet port supports DNP 3.0 and MODBUS. ADVANCED SCADA COMMUNICATIONS True Ethernet The control shall provide an integrated, true 10/100 Mbps Ethernet, auto negotiable, capable of supporting up to eight concurrent sessions and simultaneous multiple protocols with up to eight sockets (concurrent sessions) open at a time. The eight sockets shall be capable of supporting Modbus and DNP over TCP/IP and UDP with up to five of the eight sockets capable of supporting DNP 3.0. This requirement allows users simultaneous remote access to the control via the same physical Ethernet port to view/change settings or retrieve data, without affecting the SCADA communications. Full DNP Implementation The control shall provide full DNP implementation to support both report-by-exception and unsolicited reporting within DNP 3.0 to aid in the reduction of bandwidth requirements. The control shall also provide DNP File Transfer to permit the recovery of data logs and triggered events, oscillography, and device discovery to facilitate setting up the integrated system. The control shall support DNP security as defined in the DNP 3.0 standard. The control shall have DNP addressing capability that allows networking of multiple controls. The DNP implementation shall support the pre-defined global addresses within DNP 3.0 and allow the user to define two additional global addresses. Each control shall be able to be assigned a Device Address, Feeder Address, and Substation Address ranging from 1 to 65519. The control shall support broadcast commands from the master to all controls on the network in order to allow some or all controls to act on one command at the same time. This capability reduces bandwidth Page 3 of 9 and is critical for rapid response to changing system requirements with settings changes in multiple controls in selected zones. The control shall provide a configuration program that allows any point to be mapped into any DNP location and allows dummy filler points to be added to facilitate interoperability by replicating legacy vendor point-maps to SCADA. This program shall also allow for individual point dead-banding and individual point assignments into Class 1, 2, or 3. Cyber Security Within DNP, the control shall permit multiple master source-address authentications, sourceaddress validation, and multilevel access codes logged with date and time. It shall support Secure DNP authentication using FIPS 180-2 Secure Hash Standard (SHA-1). The control shall be fully compliant and offer all settings and configuration as defined by the DNP3 user group and IEC 62351-5. The control shall have a 6-15 character password and an audit log that shows when someone is logged on the control and which password was used to gain access to the control, in compliance with NERC CIP standards. The control shall allow for storage of 30 unique passwords within each control and have an SD card slot to allow the use of a password-keyed SD card that the control automatically reads to allow user login. The control’s design shall include the ability to disable ports and services not required for normal or emergency operations. In cases where disabling is not possible, the port or service shall be password and access level protected through a communication access security and timeout feature in the communication software. Bluetooth® The control shall have an option for Bluetooth® capability to enable wireless access to the control that allows the user to configure the control, read status and metering values, as well as change set points. A generic serial service shall be provided by the control’s Bluetooth® capability to facilitate establishing initial communications should the Bluetooth® not automatically recognize listed services. The Bluetooth feature shall include a secure mode with the Bluetooth module undiscoverable without a user knowing the Bluetooth hardware address in the unit to meet NERC requirements for Bluetooth communications. MONITORING/METERING Harmonic Analysis: The control shall measure, log, and display individual harmonics including THD (total harmonics distortion) and the harmonic content of the load voltage and load current up to the 31st harmonic. Oscillograph Recorder: The control shall have an oscillograph recording function that provides comprehensive data recording (voltage, current, and status input/output signals) for all monitored waveforms (at 16, 32 or 64 samples per cycle). The control shall have a means of downloading oscillograph data via the communications ports to any PC compatible personal computer running the included communications software program. The downloaded data shall be in a format that can be examined and printed. The waveform data shall also be available in COMTRADE file format. Tap Position Record: The control shall provide means of maintaining tap position information and a record of the number of times the moving contacts pass through each tap position. The tap position record is user resettable AUTO/OFF/MANUAL Switch Status: The control shall provide indication of the AUTO/OFF/MANUAL switch status through the communication ports. A or B Regulator Type: The control shall allow the user to select the type of regulator being used to provide a more accurate source voltage calculation. Page 4 of 9 User-Programmable Alarm/Self-Test Contact: The control shall have alarm capability to alert operator personnel to one or more of the following system conditions: ● Communications Block Invoked ● Block Lower Voltage Limit Exceeded ● Reverse Power Flow Condition Detected ● Tap Block Raise in Effect ● Self-test (Deadman) ● Abnormal Tap Position ● Block Raise Voltage Limit Exceeded ● Voltage Reduction (any step) Invoked ● Load Current Limit Exceeded ● Tap Block Lower in Effect ● LDC/LDZ ● Motor Seal-in Failure Real-Time Metering: The control shall meter the following measured and calculated values in real-time: ● Average Load Voltage ● Average Source Voltage ● Control Load, kVA or MVA ● Power Factor Load, Lead/Lag ● Normalizing Voltage ● Average Load Current ● Average Compensated Voltage ● Primary Voltage ● Primary Current ● Primary Watts ● Primary Vars ● Primary VA ● Frequency ● Tap Position ● Drag Hands ● Raise/Lower Timer ● Intertap Timer ● Operation Control ● Resettable Counter Present Demand: The control shall provide a Present Demand feature that captures the maximum values during the specified time interval. The user-selectable time interval shall be 15, 30, or 60 minutes. ● Demand Load Voltage ● Primary Watts ● Primary VA ● Demand Primary Current ● Primary VArs Demand History (Drag Hands Operation): The control shall have the following “drag-hand” values stored with date and time stamping, averaged over 32 seconds: ● Min Local Voltage ● Max Local Voltage The control shall have capability to store the following “drag-hand” values with date and time stamping and calculated over the demand of the user-selectable time intervals of 15, 30, or 60 minutes: ● Max Primary Current (Amps) ● Max Primary Watts (kW or MW) ● Max Primary VA (kVA or MVA) ● Max Primary VArs (kVAr or MVAr) ● Power Factor @ Max VA Energy Metering: The control shall be capable of retaining the following measured values in nonvolatile memory and have a real-time clock to record the date/time stamp for each quantity indicating when the measurement period was initiated. ● Watt Hours Forward (kWh) ● Watt Hours Reverse (kWh) ● VAr Hours Forward (kVArh) ● VAr Hours Reverse (kVArh) Data Logging: Data logging shall be provided that allows the user to record data internally into nonvolatile memory. The Data Log shall be saved in COMTRADE format and shall be capable of being downloaded using either MODBUS or DNP protocols. Sequence Of Events (SOE): The control shall contain a Sequence of Events recorder for comprehensive time tagged data recording of control parameters that include Voltage, Frequency, Tap Position, Current, Counters, and Harmonics. The Sequence of Events Recorder is triggered by user-selectable programmable parameter logic or manually by the user and shall be capable of recording up to 129 events. Computer Business Equipment and Manufacturers Association (CBEMA) Sag & Swell Recorder: The control shall provide CBEMA monitoring to detect sags and swells and trigger data collection and alarming functions. Page 5 of 9 INPUTS The control shall have the following inputs: Load Voltage Input: Nominal 120 VAC, 60 Hz (50 Hz optional); operates properly from 90 VAC to 140 VAC. If set at 60 Hz, the operating system frequency shall be from 55 to 65 Hz; if set at 50 Hz, the operating system frequency shall be from 45 to 55 Hz. The burden imposed on the input shall be 8 VA or less. A voltage transformer connected at the controlled voltage bus shall provide power to the unit. The unit shall be able to withstand twice the voltage input for one second and four times the voltage input for one cycle. Motor Power Input: The motor power input to the control shall be a nominal 120 VAC or 240 VAC, at up to 6 A as required by the load, with no wiring changes required. Motor Seal-In Input: The control shall receive an input from the regulator motor seal-in circuit. Load Current Input: The control shall have line drop compensation provided by a current transformer input with a 0.2 A full-scale rating. The burden imposed on the current source shall be 0.03 VA or less at 200 mA. The control’s load current input shall withstand 400 mA for two hours and 4 A for 1 second. Control Power Backup Input: The control shall have a DC Control Power Backup Input feature to sustain operation of the control in the event of a loss of AC input power to the control and shall be able to respond to Raise and Lower commands as long as the control’s motor power remains energized. Counter Input: The control shall have a Counter Input to detect tap position changes; the input shall update two counters, one pre-settable and one resettable. Neutral Tap Position Detect Input: The control shall have a Neutral Position Detect Input to detect the neutral tap position, which assists the tap position function. Source Voltage Input: Nominal 120 VAC, 60 Hz (50 Hz optional); operates properly from 90 VAC to 140 VAC. If set at 60 Hz, the operating system frequency shall be from 55 to 65 Hz; if set at 50 Hz, the operating system frequency shall be from 45 to 55 Hz. The burden imposed on the input shall be 8 VA or less. A voltage transformer connected at the controlled voltage bus shall provide power to the unit. The unit shall withstand twice the voltage input for one second and four times the voltage input for one cycle. The control shall use this input with the Reverse Power Measured feature when reverse power operation is desired and a Source Side PT input is available. Binary Inputs Voltage Reduction 1 and 2 Inputs: The control shall have Voltage Reduction 1 and 2 inputs to provide three levels of programmable voltage reduction that can be manually invoked. The control shall allow the Voltage Reduction Level 2 input to be used as an auxiliary input that is monitored remotely via SCADA by setting its input to “AUX”. Non-Sequential/ Auto Tapchanger Inhibit Input: The control shall have non-sequential/auto tapchanger inhibit input to provide the means to perform non-sequential operations. Page 6 of 9 OUTPUTS The control shall have the following outputs: Raise Output: Capable of switching 6 A at 120 VAC to 240 VAC motor power. Lower Output: Capable of switching 6 A at 120 VAC to 240 VAC motor power. User‑Programmable Alarm Output: One Form “C” contact capable of switching 6 A at 125 VAC or 0.2 A at 125 Vdc. FRONT PANEL CONTROLS The control shall provide the following features: The control shall provide menu-driven access to all functions by way of seven pushbuttons and a two-line alphanumeric display. There shall be two programmable Access Codes available to provide various levels of access to the control functions. The control shall have a 2-line by 20-character backlit LCD display for enhanced viewing in direct sunlight and also have a low-level LED backlight for reading in darker environments. The front panel HMI screen shall be available in either English or Spanish. RAISE/LOWER switch allows local manual raise and lower commands to be initiated. AUTO/OFF/MANUAL switch allows auto operation of the control or manual operation from the panel by using the Raise/Lower toggle switch. When this switch is in Off or Manual, the Control shall be physically unable to operate the Regulator, acting as a hard copper disconnect. VOLTAGE SOURCE switch disconnects processing power from the unit when selected to the OFF position. The EXT position allows the control to be powered from the front panel test jacks. SCADA CUTOUT (LOCAL/REMOTE) switch allows the local blocking of write commands from COM1, COM2, or Ethernet. DRAG HANDS RESET switch resets the tapchanger position indicator drag hands. EXTERNAL POWER/COM binding posts allows application of a 120 VAC rms nominal voltage to the unit for test procedures. METER OUT/COM binding posts allows measurement of the input voltage with a voltmeter. Smart Flash SD Card Slot: The control shall have an SD Card slot that allows the user to perform the following functions without the need for a laptop: ●Load Set Points ●Load DNP Configuration ●Save DNP Configuration ●Save Wake Screen Data ●Quick ●Save Set Points ●Clone Save ●Firmware Update ● Save Oscillographic Records ●Save Data Log ●Clone Load ●Save Metering Data ●Physical Security Key Capture LED Indicators: The control shall have the following LED Indicators on the front panel: Out-ofBand RAISE, Out-of-Band LOWER, REVERSE POWER flow detected, CPU OK, ALARM, VOLTAGE REDUCTION in effect, MANUAL, LOCAL, NEUTRAL, and TX/RX transmit and receive. Page 7 of 9 TESTS AND STANDARDS The control shall comply with the following type tests and standards: ELECTRICAL ENVIRONMENT Voltage Measurement Accuracy The control shall have a voltage measuring accuracy of ± 0.3 % when tested in accordance with ANSI/IEEE C57.15.9-2009 standard over a temperature range of – 40° C to + 85° C. Dielectric Withstand IEC 60255-5: 2,000 VAC for 1 minute applied to each independent circuit to earth 2,000 VAC for 1 minute applied between each independent circuit. Impulse Voltage IEC 60255-5: 5,000 V pk, +/- polarity applied to each independent circuit to earth 5,000 V pk, +/- polarity applied between each independent circuit 1.2 s by 50 s, 500Ω impedance, three surges @ 1 every 5 seconds IEC Insulation Resistance IEC 60255-5 > 100 MΩ. Surge Immunity IEC 60255-22-5: 2,000 V pk, ± polarity applied, 1.2 s by 50 s, 2Ω/12Ω impedance, five surges @ 1 every 5 seconds Voltage Interruptions Immunity IEC 60255-11-2008 TRANSIENT PROTECTION High Voltage All input and output terminals shall withstand 2,000 VAC rms to chassis or instrument ground for one minute with a leakage current not to exceed 25 mA for all terminals to ground. Input and output circuits are electrically isolated from each other, from other circuits, and from ground. Surge Withstand Capacity IEEE C37.90.1-2002 2,500 V pk Oscillatory 4,000 V pk Fast Transient Burst IEEE C37.90.1-1989 2,500 V pk Oscillatory 5,000 V pk Fast Transient NOTE: Disturbance is applied to digital data circuit (RS-485) ports through capacitive coupling clamp. Radiated Immunity IEC 60255-22-3 10V/M Fast Transient Burst Immunity IEC 60255-22-4-2008 Class A (4 kV, 2.5 kHz) NOTE: Disturbance is applied to digital data circuit (RS-485) ports through capacitive coupling clamp. Page 8 of 9 ATMOSPHERIC ENVIRONMENT Temperature: Control shall operate from – 40° C to +85° C; the LCD display’s visible temperature range shall be – 20° C to +70° C IEC 60068-2-1: IEC 60068-2-2: IEC 60068-2-78: IEC 60068-2-30: Cold, – 40° C Dry Heat, + 80° C Damp Heat, + 40° C @ 95% RH Damp Heat Condensing Cycle: 25° C, + 55° C @ 95% RH MECHANICAL ENVIRONMENT The control shall meet the following mechanical environmental specifications: IEC 60255-21-1 Vibration response Class 1: Vibration endurance Class 1: 0.5 g 1.0 g IEC 60255-21-2 Shock Response Class 1: Shock Response Class 1: Bump Endurance Class 1: 5g 15g 10g STORAGE PARAMETERS The control’s design shall allow for storage under the following conditions: Temperature Range: +5° C to +40° C Humidity: Maximum relative humidity of 80% for temperatures up to 31° C, decreasing from 31° C linearly to 50% relative humidity @ 40° C Page 9 of 9 File: M-6200A-Sugg-Spec.doc