eGateway
EN - v.01 – Dec 14, 2015
DOCUMENT CONTENTS
This document gives instructions on how to configure eGateway and how to configure
Smartlink for working and communicating with th eGateway.
The right configuration is needed to receive alarms.
CONCERNED USERS
The document contents are for technicians (engineers, IT workers, field technicians,
installation designers, project managers, …...) involved in Smartlink and eGateway
installations.
DOCUMENT PURPOSES
This document gives instructions to make a technician able to configure, and check the
communication between Smartlink and the eGateway and to configure the eGateway.
.
DOCUMENT VERSIONS
First issue:
Document Name
Version
Date
Author
eGateway- User Manual
EN-v01
14 Dec 2015 C.Carabellese C.Carabellese
Pag. 1/9
eGateway– User Manual - EN - v01 - 2015-12-14
Approved by
eGateway
EN - v.01 – Dec 14, 2015
TABLE OF CONTENTS
1. WHAT DO YOU NEED............................................................................................3
2. eGATEWAY CONNECTION....................................................................................6
3. CHANNEL CONFIGURATION...............................................................................6
Pag. 2/9
eGateway– User Manual - EN - v01 - 2015-12-14
eGateway
EN - v.01 – Dec 14, 2015
1. WHAT DO YOU NEED
To connect SmartLink with the eGateway you need a eGateway version that is upper than
5.2 and the Smartlink 2.1 version.
2. eGATEWAY CONNECTION
The eGateway works with two networks: the network of the monitor and the Hospital
network.
This is the Architecture of the networks:
For connecting the eGateway to Smartlink 2.1:
• Configure Mindray Monitors
To configure the Monitor IP click on Menu → Maintenance → User Maintenance
→ (Password 888888) → Network Setup. Set the same network of the eGateway
Mindray network. (e.i 196.76.0.60).
If a new version of monitor has to be connected with the eGateway, it is necessary to set
the CMS or eGateway in Menu → Maintenance → User Maintenance →
(Password 888888) → Gateway Communication Setting and set the IP.
• Configure eGateway network card.
Start with the eGateway in stopped status. Configure two network card: the first for the
Hospital that has to be in the same class of the Smartlink Pc ( e.i 192.168.218.48)
and the second has to be configured inserting two IP address in the same Mindray
Pag. 3/9
eGateway– User Manual - EN - v01 - 2015-12-14
eGateway
EN - v.01 – Dec 14, 2015
Network.
After the configuration, check it making a PING for both the Mindray Monitor and
Smartlink Server.
• Configure eGateway
L'eGateway needs all the whole privilegies. It is possible to set them in:
C:\Program Files\Mindray\
For configurating eGateway software it is requested a tool that it is possible
Pag. 4/9
eGateway– User Manual - EN - v01 - 2015-12-14
eGateway
EN - v.01 – Dec 14, 2015
to find in:
C:\Program Files\Mindray\eGateway\config\gatewayconfig.exe
Launch the configurator and insert in the Monitoring Network --> CMS + Translator fields
the Mindray IP and in the Hospital Network the Ip of the Hospital.
Launch the eGateway and if everything is correctly configured this screen will appear:
Pag. 5/9
eGateway– User Manual - EN - v01 - 2015-12-14
eGateway
EN - v.01 – Dec 14, 2015
3. CHANNEL CONFIGURATION
• Alarm Channel
For receiving alarms from a monitor it is necessary to open the eGateway and check if it is correctly
configured (as in Configure eGateway )
Click on Service → Configure → (Password: service), and set the IP address of the monitor in
the field Monitor Network, if there is only one monitor, or a range of IP if there is more than
one monitor.
Then click on Alarm to configure the Alarm channel:
Pag. 6/9
eGateway– User Manual - EN - v01 - 2015-12-14
eGateway
EN - v.01 – Dec 14, 2015
Insert the IP address of Smartlink and the correct port (7500)
1.Set the timeout: the time that it is necessary to wait before receiving the Acknowledge
It must be 15 seconds.
2.Set the Maximum retries: the maximum of time that the eGateway try to send the alarm.It
has to be set at 3.
3.Set as Primary Key Field Patient ID or Bed Number. These are mandatory fields,that has to be
inserted for receiving the alarms.
Note: if you don't set the variable Primary Key you aren't able to receive
the alarms.
Pag. 7/9
eGateway– User Manual - EN - v01 - 2015-12-14
eGateway
EN - v.01 – Dec 14, 2015
For checking if the configuration is correct, test if in the Status on the home page of the
eGateway this screen will appear.
Pag. 8/9
eGateway– User Manual - EN - v01 - 2015-12-14
eGateway
EN - v.01 – Dec 14, 2015
For the alarm field you will find 'Connected to AM'.
•
Result Channel
For receiving result from a monitor it is necessary to open the eGateway and check if it is correctly
configured (as in Configure eGateway )
Click on Service → Configure → (Password: service), and set the IP of the eGateway and the
correct port (7501)
Note: Set in the Mode field : Solicited Server.