* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Automation Server I/O Module Family
Radio transmitter design wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Nanogenerator wikipedia , lookup
Oscilloscope wikipedia , lookup
Digital electronics wikipedia , lookup
Crossbar switch wikipedia , lookup
Power MOSFET wikipedia , lookup
Oscilloscope history wikipedia , lookup
Surge protector wikipedia , lookup
Telecommunication wikipedia , lookup
Oscilloscope types wikipedia , lookup
Coupon-eligible converter box wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Integrating ADC wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Wilson current mirror wikipedia , lookup
Voltage regulator wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Power electronics wikipedia , lookup
Schmitt trigger wikipedia , lookup
Operational amplifier wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Current mirror wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Compatible Automation Server I/O Module Family Enables StruxureWare Building Operation v1.3 The Automation Server includes support for a broad spectrum of I/O modules that can be combined to meet the unique requirements of each installation. An Automation Server can have a maximum of 32 modules, including one Automation Server and a mixture of Power Supply modules and I/O modules. Make the most of your energy SM 2 StruxureWare Building Operation Automation Server I/O Module Family Features Each high density I/O module is designed to accommodate a fixed number of inputs and outputs. Some I/O modules only support a single electrical type, such as digital inputs. Other modules support a combination of electrical types, such as universal inputs mixed with digital outputs. The variety of modules available ensures the right combination of points for any project. Modular and scalable The Automation Server is part of a modular system that delivers power and communications on a common bus. Connecting modules is a one-step process: just slide the modules together using the built-in connectors. • Modular and scalable • Patented two-piece design • Hot-connect/ Hot-swap •Auto-addressing • Simple DIN-rail installation • Efficient terminal management • Accommodates multiple row panel installations • Hand/Off/Auto switches • LED status indicators •Protection Patented two-piece design Each module can be 2. separated from its terminal base to enable the site to be wired prior to the installation 1. of the electronics. 2. The patented locking 3. 1. mechanism also serves as handles for 3. removing the module from its base. All critical components have a protective cover that permits natural convection cooling to occur. Hot-connect / Hot-swap Because critical applications require 24-hour operation, Schneider Electric designed the Automation Server and its family of I/O modules for hot-connection of terminal bases and hotswapping of servers and modules to their bases. This design ensures continuous power and communication during service operations. Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. Product AT A GLANCE 3 Automation Server I/O Module Family Features (continued) Auto-addressing LED status indicators The auto-addressing feature eliminates the need for setting DIP switches or pressing commission buttons. With the Automation Server family, each module automatically knows its order in the chain and assigns itself accordingly - significantly reducing engineering and maintenance time. Every module has a status indicator that denotes the health and status of that module. Some modules also have LEDs that can be configured to indicate the state of a digital input or output. Simple DIN-rail installation Fasteners easily snap into a locked position for panel installation. The fastener has a quick-release feature for easy DIN rail removal. Protection Unipolar voltage suppressors on all inputs protect against high voltage or current during both transient events as well as improper wiring. Dimensional drawing The I/O module terminals are clearly labelled and protected by a transparent cover. The input and output terminals are at the top and bottom of each module and are accessible for maintenance without removing the module. The StruxureWare Building Operation WorkStation software can generate custom as-built labels for each module. Pre-perforated letter and A4 size labelmm sheets are (in.) available as an accessory. 90 (3.6) mm (in.) 90 (3.6) 114 (4.5) 64 (2.5) 64 (2.5 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. Efficient terminal management 114 (4.5) Accommodates multiple row panel installations The Automation Server module family uses built-in connectors for single row connectivity. If a panel size requires multiple rows, interconnection cables are available. Hand/Off/Auto switches Some modules are available with Hand/Off/Auto (HOA) switches to provide override control of the outputs. Analog outputs with HOA switches also have a potentiometer to modulate the output signal when the switch is in the hand position. The position of the HOA switch is readable through user interfaces, such as the StruxureWare Building Operation WorkStation software, enabling more precise monitoring and control. Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 4 Automation Server I/O Module Family Specifications The following technical specifications apply to all I/O modules, unless otherwise noted. I/O Module Inputs and Outputs Device name Inputs Outputs Digital I/O bus power HOA Digital Analog Analog 0 to 50 °C (32 to 122 °F) DI-16 16 x x Ambient temperature, storage UI-16 16 x x Humidity Current x Voltage x Form-C x Form-A x Quantity x Output Only Max. 95 % RH (non-condensing) DO-FA-12 12 x Mechanical DO-FA-12-H 12 x Dimensions including terminal base DO-FC-8 8 x 90 W x 114 H x 64 D mm DO-FC-8-H 8 x AO-8 8 x x Eco Friendly ABS/PC AO-8-H 8 x x Enclosure rating AO-V-8 8 x IP 20 AO-V-8-H 8 x (3.6 W x 4.5 H x 2.5 D in.) Enclosure Plastic rating UL94-5VB rated plastic x x x Mixed IO Mounting UI-8/DO-FC-4 8 x x x x x x x 4 x DIN-rail mounting or with screws on wall UI-8/DO-FC-4-H 8 x x x x x x x 4 x The following technical specifications apply to all UI modules: UI-8/AO-4 8 x x x x x x x 4 x x UI-8/AO-4-H 8 x x x x x x x 4 x x Non-linearized 1.8 kohm and 10 kohm UI-8/AO-V-4 8 x x x x x x x 4 x -50 to -30 °C: +/- 1.5 °C (-58 to -22 °F: +/-2.7 °F) -30 to 0 °C: +/-0.5 °C (-22 to 32 °F: +/-0.9 °F) 0 to 50 °C: +/-0.2 °C (32 to 122 °F: +/-0.4 °F) UI-8/AO-V-4-H 8 x x x x x x x 4 x Thermistor Accuracy x x x x Accesory part numbers 50 to 100 °C: +/-0.5 °C (122 to 212 °F: +/-0.9 °F) 100 to 150 °C: +/-1.5 °C (212 to 302 °F: +/-2.7 °F) DIN-RAIL-CLIP, DIN-Rail End Clip S-CABLE-I, S-Cable extension cord Package of 25 pieces for Automation Server I/O bus Balco 1 kohm P/N: SXWDINEND10001 Straight connectors, 1.5 m -50 to 150 °C: +/-1.5 °C (-58 to 302° F: +/-2.7 °F) PRINTOUT-A4-W1, Printout P/N: SXWSCABLE10001 Linearized 10 kohm sheets for Terminal Labels, A4 S-CABLE-L, S-Cable extension -50 to -30 °C: +/-3.0 °C (-58 to -22 °F: +/-5.4 °F) -30 to 0 °C: +/-1.0 °C (-22 to 32 °F: +/-1.8 °F) sheet size, 100 Sheets, 18 labels cord for Automation Server I/O bus per Sheet L shaped connectors, 1.5 m 0 to 50 °C: +/-0.3 °C (32 to 122 °F: +/-0.5 °F) 50 to 100 °C: +/-0.5 °C (122 to 212 °F: +/-0.9 °F) P/N: SXWTERLBL10011 P/N: SXWSCABLE10002 100 to 150 °C: +/-2.0 °C (212 to 302 °F: +/-3.6 °F) sheets for Terminal Labels PRINTOUT-LTR-W1, Printout Letter sheet size, 100 Sheets, 16 labels per Sheet N1831 P/N: SXWTERLBL10012 Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. –20 to +70 °C (–4 to +158 °F) Thermistor Input Only Resistance Ambient temperature, operating Current Operation environment Voltage 32 Supervised Maximum addresses per I/O bus Counter Quantity supply, Class 2 Contact 24 VDC, max. 30 W per I/O bus power 5 16 Channel Universal Input (UI-16) Automation Server I/O Module The UI-16 is a universal input, 16-channel I/O module. Each channel is capable of supporting digital (contact, counter, and supervised) or analog (voltage, current, thermistor, and resistance) point types. Analog and digital applications This module is ideal for any mix of temperature, pressure, flow, status points, and similar inputs in a building control system. The UI-16 supports a 12 bit A/D conversion. Counter applications The maximum counter frequency is 25 Hz on all sixteen inputs with a minimum pulse width of 20 milliseconds. This input type is commonly used in energy metering applications. I/O Module UI-16 Security applications Supervised points are used for security applications where it is critical to know whether or not a wire has been cut or shorted. These events provide a separate indication of alarm and trouble conditions to the system. Each channel has a dedicated two color (red and green) status LED that provides local monitoring of digital input types. The LED can be configured to display either red or green for each input state. Protection 28 VDC unipolar transient voltage suppressors on all inputs protect against high-voltage shortduration transient events. Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. Status indicators 6 UI-16 Automation Server I/O Module Specifications DC input power Analog inputs Thermistor 24 VDC, 1.8 W Voltage Range Input channels Range 16 0 to 10 VDC Digital inputs Resolution Contact Pulse width 20 ms minimum Range Open collector/open drain, 24 VDC, 2.4 mA, dry contact switch closure Counter Range Open collector/open drain, 24 VDC, 2.4 mA, dry contact switch closure Pulse width 20 ms minimum LED polarity Software selectable, if the LED is activated when the input is high or low -50 to 150 °C (-58 to 302 °F) Resolution 12 bit 12 bit Supported thermistors Accuracy +/- (0.7 mV + 0.2 % of reading) temperature sensor Reliability Internal pull-up resistor Ability to define the reliability level for upper 10 kohm thermistors and lower electrical limits 10 kohm to 5 V Impedance 1.0 (Balco) and 1.8 kohm thermistors 100 kohm 1.5 kohm to 1 V Current Mechanical Range Weight including terminal base 0 to 20 mA 0.269 kg (0.59 lb) Resolution Weight excluding terminal base 12 bit 0.146 kg (0.32 lb) Accuracy +/- (0.03 mA + 0.4 % of reading) Terminal base Impedance Detected resistor values 47 ohm Open circuit, short circuit, contact open, tored switch combinations 9 10 11 12 UI7 RET UI8 1 to 10 kohm. For a 2-resistor configuration, TB-IO-W1,Terminal Base for I/O Module (Required for each I/O Module) P/N: SXWTBIOW110001 10 to 60 kohm +/- (0.4 + 7 x 10 -6 x R) (%) Series only, parallel only, and series and parallel 8 P/N: SXWUI16XX10001 10 ohm to 10 kohm +/- (7 + 4 x 10 -3 x R) (ohm) 5 VDC circuit, 1 or 2 resistors, moni- 7 16 universal inputs Resistance and contact closed UI5 RET UI6 UI-16, I/O Module and lower electrical limits Supervised 6 Part numbers Ability to define the reliability level for upper Red or green, software selectable UI4 TB-IO-W1 Reliability LED color 1 3 5 2 4 Resistor UI1 RET UI2range UI3 RET 1.8 kohm, 10 kohm, and 1 kohm Balco Reliability Input Rating: 24 VDC each resistor is assumed Universal Inputs to have the same value. , 2.4 mA Ability to define the reliability level for upper and lower electrical limits. UI 1 3 2 UI1 RET UI2 4 5 6 UI3 RET UI4 7 8 9 UI5 RET UI6 10 11 12 UI7 RET UI8 Input Rating: 24 VDC UI 1 , 2.4 mA Status 24 VDC , 2.4 mA 13 14 15 16 17 18 19 20 21 22 23 24 UI 1 2 3 4 5 6 Status 7 8 9 10 11 12 SXW UI-16 Contact Rating: 1 2 3 250 VAC 30 VDC 4 ,3A ,3A Universal One Inputs Schneider Electric High Street, North Andover, MA 01845 USA Digital Outputs Input Rating: SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC -4 24 VDC UI9 RET UI10 UI11 RET UI12 UI13 RET UI14 UI15 RET UI16 13 14 15 16 17 18 19 20 21 22 23 24 , 2.4 mA 4 5 6 7 8 9 10 11 12 VO RET CO VO RET CO 1 2 3 4 Current Output: 0-20 mA, 650 Ω MAX Voltage Output: 0-10 VDC 5 KΩ MIN Analog Outputs V-4-HUI-8/AO-V-4-H UI-16 Input Rating: UI UI9 RET UI10 UI11 RET UI12 UI13 RET UI14 UI15 RET UI16 3 VO RET CO SXW UI-16 Universal Inputs 2 VO RET CO Universal Inputs , Hand Auto Off 1 2 3 4 5 6 7 8 9 10 11 12 VO RET CO VO RET CO VO RET CO VO RET CO 1 2 3 4 Current Output: 0-20 mA, 650 Ω MAX Voltage Output: Status 0-10 VDC 5 KΩ MIN Analog Outputs Telephone: +1 978 975 9600 , SXW UI-8/AO-V-4 Fax: +1 978 975 9698 www.schneider-electric.com/buildings Hand Universal Inputs Auto Off Input Rating: 24 VDC , 2.4 mA © 2012 Schneider Electric. All rights reserved. UI-16 Connectors 7 16 Channel Digital Input (DI-16) Automation Server I/O Module The DI-16 is a digital input, 16-channel I/O module. Each channel is capable of supporting digital (contact and counter) point types. Digital applications This module can be used for cost-effective sensing of multiple dry digital inputs in applications, such as equipment status monitoring or alarm point monitoring. Counter applications The maximum counter frequency is 25 Hz on all sixteen inputs with a minimum pulse width of 20 milliseconds. This input type is commonly used in energy metering applications. I/O Module DI-16 Protection 28 V unipolar transient voltage suppressors on all inputs protect against high voltage short duration transient events. The DI-16 is designed to accept dry contact inputs but can withstand up to 24 VDC continuous voltages on all sixteen channels. Each channel has a dedicated two color (red and green) status LED that provides local monitoring of digital input types. The LED can be configured to display either red or green for each input state. Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. Status indicators 8 DI-16 Automation Server I/O Module Specifications DC input power Mechanical 24 VDC, 1.6 W Weight including terminal base 0.255 kg (0.56 lb) Input channels 16 1 2 3 VO RET CO 4 Weight excluding terminal base 5 6 7 VO RET CO Digital1 inputs 8 9 10 11 12 VO RET CO VO RET CO 3 4 2 Current Output: 0.131 kg (0.29 lb) 0-20 mA, 650 Ω MAX Voltage Output: , Terminal base 0-10 VDC 5 KΩ MIN Analog Outputs UI-8/AO-4-H UI-8/AO-4-H Contact TB-IO-W1 Pulse width Part numbers Hand 20 ms minimum Auto DI-16, I/O Module Off Range Current Output: dry contact switch closure 0-20 mA, 650 Ω MAX VO RET CO VO RET CO VO RET CO VO RET CO 1 2 3 4 P/N: SXWDI16XX10001 TB-IO-W1, Terminal Base for I/O Module Status Voltage Output: 0-10 VDC 5 KΩ MIN Counter Analog Outputs , (Required for each I/O Module) SXW UI-8/AO-4 Range P/N: SXWTBIOW110001 Hand Universal Inputs Open collector/open drain, 24 V, 2.4 mA, Auto Off dry contact switch closure UI1 RET UI2 UI3 Pulse width 13 14 15 16 RET UI4 17 18 Input Rating: 24 VDC UI5 RET UI6 UI7 RET UI8 19 22 20 21 23 , 2.4 mA 24 20 ms minimum LED polarity Status 5 1 2 3 4 6 if the 7 8LED 9 is10activated 11 12 Software selectable, DI1 RET DI2 DI3 RET DI4 DI5 RET DI6 when the input is high or low DI7 RET DI8 SXW UI-8/AO-4 Input Rating: 24 VDC Universal Inputs LED color Digital Inputs Red or green, software selectable UI1 RET UI2 UI3 RET UI4 13 14 15 16 Connectors DI-16 16 digital inputs Open 1 2collector/open 3 4 5 6 drain, 7 8 24 9 V,102.411mA, 12 1 2 3 DI1 RET DI2 4 17 18 5 6 DI3 RET DI4 Input Rating: 24 VDC UI5 RET UI6 UI7 RET UI8 19 20 21 22 23 24 7 8 9 10 11 12 DI5 RET DI6 , 2.4 mA , 2.4 mA DI7 RET DI8 Input Rating: Status 24 VDC , 2.4 mA Digital Inputs SXW DI-16 Digital Inputs DI-16 Input Rating: 24 VDC , 2.4 mA DI9 RET DI10 DI11 RET DI12 DI13 RET DI14 DI15 RET DI16 13 14 15 16 17 18 19 20 21 22 23 24 Status Digital Inputs Input Rating: 24 VDC , 2.4 mA DI9 RET DI10 DI11 RET DI12 DI13 RET DI14 DI15 RET DI16 13 14 15 16 17 18 19 20 21 22 23 24 Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. SXW DI-16 9 8 Channel Analog output (AO-8), (AO-8-H) Automation Server I/O Module The AO-8 and AO-8-H are analog output, 8-channel I/O modules. Each channel is capable of supporting analog (voltage and current) point types. Analog applications The AO-8 and AO-8-H are designed for a maximum control range of 0 to 10 V outputs and therefore support a wide-range of devices, such as valves and actuators. Current applications The AO-8 and AO-8-H can be used to drive a maximum control range of 0 to 20 mA current signals on any of its eight channels. I/O Module AO-8 Protection These I/O Modules have protection against shortcircuit to ground. Overrides I/O Module AO-8-H Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. The front panel of the AO-8-H includes Hand/ Off/Auto (HOA) override switches with adjustable potentiometers. 10 AO-8 AO-8-H Automation Server I/O Module Specifications DC input power Terminals 24 VDC, 4.9 W Current (A), Return Maximum load Output channels Output load should not exceed 650 ohm 8 Mechanical Analog outputs Weight including terminal base Voltage 0.282 kg (0.62 lb) Range Weight excluding terminal base 0 to 10 VDC 0.159 kg (0.35 lb) Resolution 50 mV B Part numbers Terminals AO-8, I/O Module LD Voltage (V), Return Minimum load Tx HO Source: 2 mA Shield 3 4 5 6 7 8 9 10 11 12 Rx AbilityRxto define the reliability level for upper and1 lower electrical limits. 2 3 4 5 6 7 VO RET CO 11 12 Current Output: 3 4 Output: RS-4220Voltage to 10 VDC , TX/RX TX/RX Bias Shield Bias TX/RX TX/RX Bias Shield TX TX Port Bmin. 5 kohm 1 2 3 4 5 6 7 8 9 10 11 12 Connectors 3 10 SXW VO RET COUSBx-SERIAL 0 to 20 mA, Bias Host 2 9 max. 650 ohm 2 RS-485 Port A Analog Outputs 1 8 VO RET CO Status 4 5 6 7 8 9 10 11 12 VO RET CO VO RET CO VO RET CO VO RET CO 1 2 3 4 Status Voltage Output: 0 to 10 VDC min. 5 kohm Analog Outputs , SXW AO-8 Analog Outputs 5 Current Output: 0 to 20 mA, max. 650 ohm Current Output: 6 7 0 to 20 mA, max. 650 ohm 8 Voltage Output: VO RET CO VO RET CO VO RET CO VO RET CO 13 16 19 22 14 15 17 18 20 21 23 24 0 to 10 VDC min. 5 kohm , Status SXW AO-8 Analog Outputs 5 Current Output: 6 7 0 to 20 mA, max. 650 ohm 8 Voltage Output: VO RET CO VO RET CO VO RET CO VO RET CO 13 16 19 22 14 15 17 18 20 21 23 24 0 to 10 VDC min. 5 kohm , Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. VO RET CO Accuracy P/N: SXWTBIOW110001 TX TX/RX Bias 2 (Required for each I/O Module) Port B HO TX/RX Reliability 1 SXWAO8HXX10001 TB-IO-W1, Terminal Base for I/O Module RS-422 Port A Tx Off/Auto override switches SXW USBx-SERIAL P/N: LD RS-485 Status TX 0 to 20 mA 8 analog current/voltage outputs with Hand/ B Shield Range 0.1 mA AO-8-H, I/O Module with HOA switches TX/RX Current Tx P/N: SXWAO8XXX10001 Bias A Resolution Host 8 analog current/voltage outputs RS-232 Ports Rx TX/RX Sink:Rx-1 mA Bias Tx +/- 0.21mA AO-8 TB-IO-W1 +/- 100 mV Bias USBx-SERIAL USBx-SERIAL Accuracy AO-8 Terminal base RS-232 Ports A 11 8 Channel Analog Output (AO-V-8), (AO-V-8-H) Automation Server I/O Module The AO-V-8 and AO-V-8-H are analog output, 8-channel I/O modules. Each channel is capable of supporting analog (voltage) point types. Analog applications The AO-V-8 and AO-V-8-H are designed for a maximum control range of 0 to 10 V outputs and therefore support a wide-range of devices, such as valves and actuators. Protection These I/O Modules have protection against shortcircuit to ground. Overrides The front panel of the AO-V-8-H module includes Hand/Off/Auto (HOA) override switches with adjustable potentiometers. I/O Module AO-V-8-H Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. I/O Module AO-V-8 12 AO-V-8 AO-V-8-H Automation Server I/O Module Specifications DC1 input 2 3 power 4 5 6 7 8 9 10 11 Mechanical 12 VO RET CO VO RET CO VO RET CO VO RET CO 1 2 3 4 24 VDC, 0.7 W Current Output: 0 to 20 mA, max. 650 ohm Weight including terminal base Voltage Output: 0.279 kg (0.61 lb) , 0 to10 VDC min 5 kohm OutputAnalog channels Outputs Weight excluding terminal base 0.156 kg (0.34 lb) Hand Analog outputs Auto Terminal base Off Voltage 2 TB-IO-W1 3 CO 4 5 6 VO RET CO 0 to 101 VDC 7 8 9 10 11 12 VO RET CO VO RET CO 3 4 2 Current Output: 0 to 20 mA, max. 650 ohm Part numbers 8 analog SXW AO-8 50 mV AO-8-H Hand Auto +/- 1005 mV 6 Terminals VO RET CO VO RET CO VO RET CO VO RET CO 16 19 22 15 7 Source: 23 mA 1 2 4 5 VO RET VO RET 1 2 8Off 18 20 21 23 24 6 7 8 VO RET 9 10 11 0-10 VDC 5 KΩ MIN 8 9 10 11 12 2 3 Digital Outputs 250 VAC 30 VDC 4 VO RET 3 , DO override switches SXW AO-8 (Required for each I/O Voltage Output: 1 Module) 0-20 mA, 650 Ω MAX VO RET CO VO RET CO VO RET CO 19 22 5 6 7 8 VO RET 2 1 20 21 9 23 10 11 VO RET 3 0-10 VDC 5 KΩ MIN 24 , 6 7 DO 2 8 9 10 11 12 Contact Rating: 3 250 VAC ,3A Status, 3 A 30 VDC 4 SXW DO-FC-8 Digital Outputs 12 Voltage Output: 0 to 10 VDC Status min. 5 kohm 4 DO-FC-8 4 VO RET 18 5 Current Output: VO RET CO 17 4 Digital Outputs P/N:, SXWTBIOW110001 0 to 10 VDC min. 5 kohm 8 13 14 15 16 Connectors 3 TB-IO-W1, Terminal Base 5 for 6 I/O 7 Module 8 4 7 5 13 14 5 1 , 6 7 8 Contact Rating: DO 15 6 2 3 250 VAC 30 VDC 16 DO 4 18 17 7 19 20 21 22 23 24 8 5 Status 6 7 8 9 10 11 12 SXW DO-FC-8 SXW AO-V-8 1Digital Outputs 2 5Digital Outputs 6 3 7 250 VAC 30 VDC 4 8 14 15 VO RET 16 17 18 VO RET 19 Voltage Output: 8 20 21 VO RET 22 23 0 to 10 VDC min. 5 kohm 24 Status 1 2 VO RET 3 4 5 VO RET 6 7 8 VO RET 2 1 9 10 11 VO RET 3 12 SXW AO-V-8 Voltage Output: 4 0 to 10 VDC min. 5 kohm Voltage Output: Analog Outputs Outputs Analog 5 6 7 8 VO RET VO RET VO RET VO RET 13 AO-V-8-H , 14 1 2 VO RET 15 3 16 17 4 5 VO RET 18 6 19 7 8 VO RET 2 1 20 21 9 22 23 10 11 VO RET 3 0 to 10 VDC min. 5 kohm , , 24 12 Voltage Output: 0 to 10 VDC Status min. 5 kohm 4 , 13 DO-FC-8-H 13 7 DO-FC-8-H AO-V-8 6 250 VAC 30 VDC 15 16 17 18 19 20 21 22 23 24 7 8 9 10 11 12 Hand Off 1 2 3 4 5 6 Contact Rating: 1 2 Hand 3 Auto Digital OutputsOff SXW DO-FC-8 Digital OutputsHand Auto 5 13 14 6 15 16 17 Off 18 250 VAC Status,, 33 A 30 VDC A 4 7 8 Contact Rating: 250 VAC 30 VDC 19 20 21 22 23 Status Hand Auto Off SXW DO-FC-8 Digital Outputs 5 Analog Outputs 6 VO RET 13 14 15 7 VO RET 16 17 18 VO RET 19 20 21 VO RET 22 6 7 8 Contact Rating: 250 VAC 30 VDC Voltage Output: 8 23 0 to 10 VDC min. 5 kohm ,3A ,3A 24 Analog Outputs 5 ,3A ,3A Auto SXW AO-V-8 AO-V-8-H 14 ,3A ,3A Contact Rating: Analog Outputs 5 ,3A ,3A Contact Rating: Analog Outputs VO RET ,3A ,3A 8 analog voltage outputs with Hand/Off/Auto Voltage Output: AO-V-8 7 AO-V-8-H, I/O Module with HOA switches 12 6 3 1 P/N: SXWAOV8HX10001 1 2 Analog Outputs Analog Outputs 2 6 0-20 mA, 650 Ω MAX Status 5 1 5 Current Output: Minimum load VO RET 4 Voltage Output: 17 Voltage (V), Return Sink: -1 mA 3 Contact Rating: voltage outputs P/N: SXWAOV8XX10001 Accuracy Analog Outputs 14 2 , AO-V-8, I/O Module 0 to10 VDC min 5 kohm Resolution Analog Outputs 13 1 Status Voltage Output: , 13 14 15 16 17 18 19 20 21 22 23 ,3A ,3A 24 24 Status Schneider Electric One High Street, North Andover, MA 01845 USA SXW AO-V-8 SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Analog Outputs Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. 1 Range VO RET DO-FC-8 AO-8-H 8 13 12 Channel Digital Output, Form-A (DO-FA-12), (DO-FA-12-H) Automation Server I/O Module The DO-FA-12 and DO-FA-12-H are digital output 12-channel I/O modules. Each channel is capable of supporting digital (Form-A) point types. Direct load applications The Form-A relays in the DO-FA-12 and DO-FA-12-H are designed for direct load applications for up to 2 A per output. Status indicators and overrides The front panel of the DO-FA-12 and DO-FA-12-H module includes a digital output indicator using a green LED. Additionally, the DO-FA-12-H module has Hand/Off/Auto (HOA) override switches. I/O Module DO-FA-12-H Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. I/O Module DO-FA-12 14 DO-FA-12 DO-FA-12-H Automation Server I/O Module Specifications DC input power Mechanical 24 VDC, 1.8 W Weight including terminal base 0.317 kg (0.70 lb) Output channels Weight excluding terminal base 12 0.194 kg (0.43 lb) Contact rating Terminal base 250 VAC, 30 VDC, 2 A TB-IO-W1 Digital outputs Part numbers Form A relay DO-FA-12, I/O Module Terminals 12 Form A digital outputs Common (C), Normally Open (NO) P/N: SXWDOA12X10001 Pulse width DO-FA-12-H, I/O Module with HOA 100 ms minimum switches Isolation 12 Form A digital outputs with Hand/Off/ 1500 VAC minimum, coil to contact 1 2 3 4 5 6 7 8 9 10 Auto override switches 11 P/N: SXWDOA12H10001 12 TB-IO-W1, Terminal Base for I/O Module Contact Rating: 1 2 3 4 5 250 VAC 30 VDC 6 Digital Outputs ,2A ,2A (Required for each I/O Module) P/N: SXWTBIOW110001 1 2 3 4 5 6 7 8 9 10 11 12 Contact Rating: 1 2 3 4 5 250 Status VAC ,2A 30 VDC ,2A 6 Digital Outputs 1 2 3 4 5 6 7 8 9 10 11 12 VO RET CO VO RET CO VO RET CO VO RET CO 1 2 3 4 SXW DO-FA-12 Voltage Output: 0-10 VDC 5 KΩ MIN 9 10 11 12 Contact Rating: 250 VAC 30 VDC 13 14 15 16 17 18 19 20 21 22 23 ,2A ,2A 24 Status 1 2 3 4 5 6 7 8 9 10 11 12 Contact Rating: 1 7 250 VAC 30 VDC 2 3 4 5 6 8 9 10 11 12 Digital Digital Outputs Outputs Contact Rating: 250 VAC 30 VDC 13 14 15 16 17 18 19 20 2 3 4 21 22 Auto 23 ,2A ,2A 24 Off DO 1 Hand ,2A ,2A 5 6 7 8 9 10 11 12 Contact Rating: 1 DO 2 3 Hand 4 Auto Digital Outputs 5 250 VAC ,2A Status, 2 A 30 VDC 6 UI-8/AO-4-H UI-8/AO-4-H 8 SXW DO-FA-12 DO-FA-12-H , Digital Outputs 7 Hand Auto Off 1 2 Digital Outputs 8 14 15 16 17 Auto 10 18 Off 19 20 DO 3 4 5 11 Contact Rating: 250 VAC 30 VDC 21 22 23 ,2A ,2A 7 8 Off9 Status 10 11 12 650 Ω MAX SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC 1 2 3 4 Voltage Output: Digital Outputs Analog Outputs 8 9 9 10 11 12 VO RET CO 1 2 3 4 10 11 Current Output: 0-20 mA, 650 Ω MAX Status Voltage Output: 0-10 VDC 5 KΩ MIN Analog Outputs , SXW UI-8/AO-4 Hand Universal Inputs Auto Input Rating: Off 24 VDC UI1 RET UI2 UI3 RET UI4 UI5 RET UI6 UI7 RET UI8 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 , 2.4 mA Status DI1 RET DI2 DI3 RET DI4 DI5 RET DI6 SXW UI-8/AO-4 DI7 RET DI8 24 VDC , 2.4 mA Input Rating: UI1 RET UI2 UI3 RET UI4 UI5 RET UI6 UI7 RET UI8 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 , 2.4 mA 24 SXW DO-FA-12 0-20 mA, 7 8 24 VDC 12 Hand 6 7 VO RET CO Input Rating: Current Schneider Electric One High Street, North Andover, MAOutput: 01845 USA VO RET CO VO RET CO VO RET CO VO RET CO 2 6 Universal Inputs Digital Inputs Auto 1 5 Hand 9 DO 13 4 VO RET CO SXW DO-FA-12 7 3 VO RET CO Off 12 0-10 VDC 5 KΩ MIN , Contact Rating: DI-16 DO-FA-12 Analog Outputs DO-FA-12-H Current Output: 0-20 mA, 650 Ω MAX DI1 RET DI2 DI3 RET DI4 Telephone: +1 978 975 9600 Digital Inputs DI5 RET DI6 DI7 RET DI8 Rating: Fax: +1 978 975 9698 Input www.schneider-electric.com/buildings Status 24 VDC , 2.4 mA SXW DI-16 © 2012 Schneider Electric. All rights reserved. DO-FA-12 Connectors 15 8 Channel Digital Output, Form-C (DO-FC-8), (DO-FC-8-H) Automation Server I/O Module The DO-FC-8 and DO-FC-8-H are digital output 8-channel I/O modules. Each channel is capable of supporting digital (Form-C) point types. Direct load applications The Form-C relays in the DO-FC-8 and DO-FC-8-H are designed for direct load applications for up to 3 A per output. Status indicators and overrides The front panel of the DO-FC-8 and DO-FC-8-H modules includes a digital output indicator using a green LED. Additionally, the DO-FC-8-H module has Hand/Off/Auto (HOA) override switches. I/O Module DO-FC-8 -H Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. I/O Module DO-FC-8 16 DO-FC-8 DO-FC-8-H Automation Server I/O Module Specifications DC input power Mechanical 24 VDC, 2.2 W Weight including terminal base 0.332 kg (0.73 lb) Output channels Weight excluding terminal base 8 0.209 kg (0.46 lb) Contact rating Terminal Base 250 VAC, 30 VDC, 3 A TB-IO-W1 Digital outputs : Part numbers Form C Relay DO-FC-8, I/O Module Terminals 8 Form C digital outputs Common (C), Normally Open (NO), Normally P/N: SXWDOC8XX10001 Closed (NC) DO-FC-8-H, I/O Module with HOA Pulse width switches 100 ms minimum 8 Form C digital outputs with Hand/Off/Auto Isolation override switches 1500 VAC minimum, coil to contact 1 : 2 3 4 5 6 7 8 9 10 P/N: SXWDOC8HX10001 11 12 TB-IO-W1, Terminal Base for I/O Module Contact Rating: 1 2 3 Digital Outputs 250 VAC 30 VDC 4 ,3A (Required for each I/O Module) ,3A P/N: SXWTBIOW110001 DO-FC-8 Connectors DO 1 2 3 5 6 1 4 5 7 DO 6 7 8 9 10 11 12 Contact Rating: 8 2 3 Digital Outputs 250 VAC Status ,, 33 A 30 VDC A 4 SXW DO-FC-8 : Digital Outputs 5 6 7 8 Contact Rating: DO 13 14 15 5 1 6 2 3 250 VAC 30 VDC 16 DO 4 17 7 18 19 20 21 22 23 5 ,3A ,3A 24 8 Status 6 7 8 9 10 11 12 SXW DO-FC-8 Contact Rating: 13 14 15 16 17 3 7 250 VAC 30 VDC 4 8 Contact Rating: 250 VAC 30 VDC 18 Hand ,3A ,3A 19 20 21 22 23 24 7 8 9 10 11 12 ,3A ,3A Auto Off 1 2 3 4 5 6 Contact Rating: 1 2 Hand Auto Digital OutputsOff 3 250 VAC Status , 3 A 30 VDC ,3A 4 SXW DO-FC-8 : DO-FC-8-H : Digital Outputs Hand Auto 5 13 14 6 15 16 17 Off 18 7 8 Contact Rating: 250 VAC 30 VDC 19 Hand 20 21 22 23 ,3A ,3A 24 Status Schneider Electric One High Street, North Andover, MA 01845 USA Auto Off SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC SXW DO-FC-8 Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. 1 Digital Outputs 2 5Digital Outputs 6 DO-FC-8-H : DO-FC-8 : 17 8 Channel Universal Inputs with 4 Analog Outputs (UI-8/AO-4, UI-8/AO-4-H) Automation Server I/O Module Analog applications Analog and digital applications The UI-8/AO-4 and UI-8/AO-4-H can be used to drive a maximum control range of 0 to 20 mA current signals on any of its eight output channels. This module is ideal for any mix of temperature, pressure, flow, status points, and similar inputs in a building control system. The eight input channels supports a 12 bit A/D conversion. Counter applications The maximum counter frequency on all eight inputs with a minimum pulse width is 20 milliseconds. This input type is commonly used in energy metering applications. Security applications Supervised points are used for security applications where it is critical to know whether or not a wire has been cut or shorted. These events provide a separate indication of alarm and trouble conditions to the system. The UI-8/AO-4 and UI-8/AO-4-H are designed for a maximum control range of 0 to 10 V outputs and therefore support a wide-range of devices, including valves and actuators on any of its eight output channels. Current applications Protection 28 V unipolar transient voltage suppressors on all inputs protect against high voltage short duration transient events. Status indicators and overrides The front panel of the UI-8/AO-4 and UI-8/AO-4-H I/O modules includes a digital output indicator using a green LED. Additionally, the UI-8/AO-4-H module has Hand/Off/Auto (HOA) override switches with adjustable potentiometers for each output. I/O Module UI-8/AO-4-H Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. I/O Module UI-8/AO-4 The UI-8/AO-4 and UI-8/ AO-4-H are combination I/O modules supporting 8 universal input channels and 4 analog output channels. These compact modules are ideal when an application requires a mix of point types. 18 UI-8/AO-4 UI-8/AO-4-H Automation Server I/O Module Specifications 1 3 4 5 6 7 9 10 11 12 Contact Rating: Accuracy 1 2 3 4 +/- (7 mV + 0.2 %Digital of reading) Outputs 5 250 VAC ,2A Analog outputs 30 VDC ,2A 6 Voltage Range Impedance 100 kohm Current Accuracy Digital inputs Resolution 50 mV +/- (0.03 mA + 0.4 % of reading) Accuracy Reliability +/- 100 mV Status Terminals 20 ms minimum Ability to define the reliability level for upper and lower electrical limits. Range Resolution Open collector/open drain, 24 V, 2.4 mA, dry contact switch closure 12 bit Counter Range Impedance Contact Pulse width SXW DO-FA-12 Voltage (V), Digital Outputs 7 8 9 10 +/- (0.03 mA + 0.4 % of reading) 11 30 VDC 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 Resistance 10 ohm to 10 kohm 1 2 3 +/- (7 + 4 x 10 -3 Digital x R) (ohm) Outputs 10 kohm to 60 kohm +/- (0.4 + 7 x 10 -6 x R) (%) 20 ms minimum LED polarity DO-FA-12-H Software selectable, if the LED is activated when the input is high or low 4 5 Red or green, software selectable Supervised Detected resistor values Analog Outputs UI-8/AO-4 4 SXW AO-8 12 bit 5 Hand 3 4 5 6 7 SXW DO-FA-12 0.276 kg (0.61 7 0-20 mA, 650 Ω MAX 8 1 VO RET CO VO RET CO 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 Connectors 0-10 VDC 5 KΩ MIN , DO-FC-8 VO RET CO 13 2 1 VO RET 2 VO RET 3 VO RET 4 UI5 RET UI6 16 19 20 21 7 8 9 Voltage Output: 0 to 10 VDC min. 5 kohm , 6 DO 7 24 11 12 Part numbers 4 8 8 13 16 19 22 20 21 4 5 6 DI3 RET DI4 Status Input Rating: 24VDC UI7 RET UI8 18 3 DI2 Current Output: UI-8/AO-4, I/O Module 0-20 mA, 650 Ω MAX 8 universal inputs, 4 analog voltage/current Voltage Output: 0-10 VDC , outputs 5 KΩ MIN P/N: SXWUI8A4X10001 Digital Inputs 9 UI-8/AO-4-H, 10 11 12 I/O Module with HOA Contact Rating: switches 250 VAC ,3A 30 VDC A DI9 RET DI10 DI11 RET DI12 8 universal inputs, 4, 3 analog voltage/current 4 13 14 15 16 17 18 outputs with Hand/Off/Auto override switches P/N: SXWUI8A4H10001 TB-IO-W1, Terminal Base for I/O Module Status (Required for each I/O Module) P/N: SXWTBIOW110001 SXW UI-8/AO-4 UI5 RET UI6 17 18 23 , 2.4mA SXW DO-FC-8 24 Analog Outputs Digital Outputs Terminals 3, 6, 9, and 12 are not used 5 6 7 8 Contact Rating: AO-V-8 250 VAC 30 VDC 13 Schneider Electric One High Street, North Andover, MA 01845 USA 14 15 16 17 18 Telephone: +1 978 975 9600 19 20 21 22 23 1 2 3 4 5 6 7 8 9 10 11 ,3A ,3A 24 Fax: +1 978 975 9698 SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Status DI5 RET DI6 ,2A ,2A RET CO UI3 RET UI4 15 17 lb) TB-IO-W1 UI1 RET UI2 14 15 Terminal base 23 DO 5 14 Contact Rating: 250 VAC 30 VDC 3 Digital Outputs Universal Inputs VO RET UI3 RET UI4 13 0.152 kg (0.34 lb) 12 Voltage Output: VO RET CO UI1 RET UI2 Weight excluding terminal base Digital Inputs Current Output: 6 Off Output load should not exceed 650 ohm Output channels Resolution Auto Mechanical 1 2 Status RET Weight including terminal DI1 base 2 9 Hand Thermistor 1 8 3 Maximum load DO 7 Universal Inputs Current (I), Return Off 6 2 DO level for upper Ability to define the reliability and lower electrical limits. Status 0 to 10 V ,2A ,2A Accuracy Auto 5 1 Terminals Auto Range Off Open circuit, short circuit, contact open, -50 to 150 °C (-58 to 302 °F) and contact closed Resolution Digital Outputs 5 V1 circuit, 14 or5 2 resistors, monitored 12 bit 2 3 6 7 8 9 10 11 12 7 8 9 10 11 Current Output: VO RET combinations CO VO RET CO VO RET CO VO RET CO 0 to 20 mA, switch Supported thermistors max. 650 ohm Series 1only, parallel2 only, and 3series and4parallelVoltage Output: 1.8 kohm. 10 kohm, and 1 kohm Balco 13 14 15 16 17 18 19 20 21 22 0 to10 VDC , Resistor range temperature sensor min 5 kohm Analog Outputs 1 to 10 kohm. For a 2-resistor configuration, each resistor is assumed to have the same value. Internal pull-up resistor Hand 1 2 3 4 5 6 7 8 9 10 10 kohm thermistors VO RET CO VO RET CO VO RET CO VO Auto Off Analog inputs 10 kohm to 5 V 1 2 3 1.0 (Balco) and Analog 1.8 kohm thermistors Outputs Voltage 1.5 kohm to 1 V Range Resolution Contact Rating: Hand 4 VO RET CO +/- 0.2 mA Reliability LED color ,2A 0 to 20 mA VAC 0.1250 mA 30 VDC 3 Analog Outputs Current Range 6 2 VO RET CO Return Source 2 mA Contact Rating: 250 VAC ,2A Sink -1 mA 12 47 ohm Pulse width 1 VO RET CO Minimum load Accuracy Open collector/open drain, 24 V, 2.4 mA, dry contact switch closure AO-8-H 0 to 10 VDC DO-FA-12 8 12 www.schneider-electric.com/buildings DI13 RET DI14 19 20 © 2012 Schneider Electric. All rights reserved. Input channels UI-8/AO-4-H 24 VDC, 3.2 W 8 DI-16 DC input power 2 21 19 8 Channel Universal Inputs with 4 Channel Voltage Outputs (UI-8/AO-V-4, UI-8/AO-V-4-H) Automation Server I/O Module The UI-8/AO-V-4 and UI-8/ AO-V-4-H are combination I/O modules supporting 8 universal input channels and 4 voltage output channels. These compact modules are ideal when an application requires a mix of point types. Analog and digital applications I/O Module UI-8/AO-V-4-H This module is ideal for any mix of temperature, pressure, flow, status points, and similar inputs in a building control system. The eight input channels supports a 12 bit A/D conversion. Counter applications The maximum counter frequency on all eight inputs with a minimum pulse width is 20 milliseconds. This input type is commonly used in energy metering applications. Analog applications The UI-8/AO-4 and UI-8/AO-4-H are designed for a maximum control range of 0 to 10 V outputs and therefore support a wide-range of devices, such as valves and actuators on any of its eight output channels. Protection 28 V unipolar transient voltage suppressors on all inputs protect against high voltage short duration transient events. Status indicators and overrides The front panel of the UI-8/AO-4 and UI-8/AO-4-H I/O modules includes a digital output indicator using a green LED. Additionally, the UI-8/AO-4-H module has Hand/Off/Auto (HOA) override switches with adjustable potentiometers for each output. Supervised points are used for security applications where it is critical to know whether or not a wire has been cut or shorted. These events provide a separate indication of alarm and trouble conditions to the system. Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. Security applications 20 UI-8/AO-V-4 UI-8/AO-V-4-H Automation Server I/O Module Specifications Resolution Output channels 24 VDC, 1.0 W 12 bit 4 Accuracy +/- (7 mV + 0.2 % of reading) 8 Impedance 2 UI1 RET UI2 UI3 RET UI4 8 9 UI5 RET UI6 10 11 100 kohm Voltage Range Current Accuracy 0 to 10 VDC 12 UI7 RET UI8 Input Rating: Contact Universal Pulse Inputs width 24 VDC , 2.4 mA Reliability Accuracy Range Ability to define the reliability level for upper and lower electrical limits. +/- 100 mV Terminals Resolution Voltage (V), Return 12 bit Minimum load Accuracy UI Impedance 47 ohm 24 VDC LED polarity , 2.4 mA 2 17 18 19 20 21 22 23 24 7 8 9 10 11 12 LED color 3 4 5 6 2 3 Supervised Digital Outputs 250 VAC 30 VDC 4 11 4 Input Rating: 24 VDC UI3 RET UI4 Voltage 16 17 Range 15 18 UI5 RET UI6 UI7 RET UI8 19 22 23 24 10 711 12 20 21 3 55 4 6 68 7 9 VO RET CO VO RET CO VO RET CO 13 16 17 18 19 20 21 4 5 6 7 8 9 14 15 2 Connectors 3 Digital Outputs 4 Internal pull-up resistor 1 2 Status 0-20 mA, 650 Ω MAX 8 Auto Off Mechanical Statusincluding terminal base Weight 5 KΩ MIN , VAC 24, 3 A 22250 23 30 VDC ,3A 3 4 Hand 2 VO RET Auto Off 1 3 VO RET 2 VO RET 3 5 6 7 8 3 DO Universal Inputs 1 10 11 VO RET 12 Voltage Output: 0 to 10 VDC min. 5 kohm 4 , 0.275 kg (0.61 lb) SXW UI-8/AO-V-4 Weight excluding terminal base 0.152 kg (0.34 lb) Voltage Output: VOContact RET Rating: CO 0-10 VDC , 10 kohm thermistor 10 kohm to 5 V 1.0 (Balco) and 1.8 kohm thermistor 1.5 kohm to 1 V Hand 10 kohm thermistor 10 kohm to 5 V SXW AO-8 1 2 Outputs 1.0 (Balco) and 1.8 kohmDigital thermistor Current Output: 1.5 kohm to 1 V , 2.4 mA Voltage Output: 0-10 VDC 5 KΩ MIN pull-up resistor Internal Input Rating: DO-FC-8 Analog inputs Source 2 mA Current Output: 0-20 mA, Sink -1 mA 12 650 Ω MAX 3 0 to 20 mA, max. 650 ohm UI-8/AO-V-4 AO-8-H 10 VO RET CO Analog Outputs 0 to 10Analog VDC Outputs 1 2 9 Range UI1 RET UI2 UI3 RET UI4 UI5 RET UI6 UI7 RET 1 3 4 Voltage Output: 13 (-58 14 15 16 17°F)18 19 20 21 22 23 -50, to 150 °C to 302 5 V circuit, 1 or2 2 resistors, monitored 0 to10 VDC min 5 kohm Outputs Resolution switchAnalog combinations 12 bit Series only, parallel only, and series and parallel 1 2 3 4 5 6 7 8 9 10 11 Hand Status Supported thermistors Resistor range VO RET CO VO RET CO VO RET CO VO RET Auto 1.8 kohm. 10 kohm, and 1 kohm Balco temp. 1 to 10 kohm. For a 2-resistor configuration, Off 1 2 3 4 SXW UI-8/DO-FC-4 sensor each resistor is assumed to have the same value. UI1 RET UI2 2 1 8 RET CO Universal Inputs Thermistor Current Output: Universal Inputs 1 7 Ability to define the reliability level for upper and lower electrical limits. ,3A ,3A Open circuit, contact 1 2circuit, 3 4short 5 6 7 8 9 10 open, 11 12 VO RET CO VO RET CO VO RET CO VO RET CO and contact closed 14 6 Analog Outputs Detected resistor values 13 5 Reliability Red or green, software selectable Contact Rating: 1 4 10 ohm to 10 kohm +/-(7 + 4 x 10 -3 x R) (ohm) 10 kohm to 60 kohm +/-(0.4 + 7 x 10 -6 x R) (%) Software selectable, if the LED is activated when the input is high or low 16 3 Resistance Input Rating: UI9 RET UI10 UI11 RET UI12 UI13 RET UI14 UI15 RET UI16 15 2 UI-8/AO-V-4-H Pulse Inputs width Universal 20 ms minimum 1 RET % CO of VO reading) RET CO VO +/- (0.03 mA VO + 0.4 Status Open collector/open drain, 24 V, 2.4 mA, SXW UI-16 dry contact switch closure 1 50 mV 20 ms minimum Counter Range 14 Resolution +/- (0.03 mA + 0.4 % of reading) Open collector/open drain, 24 V, 2.4 mA, UI dry contact switch closure 13 Analog outputs 5 6 DO 24 VDC TB-IO-W1 24 Part numbers Current Output: UI-8/AO-V-4, I/O Module 0-20 mA, 650 Ω MAX 8 universal inputs, 4 analog voltage outputs Voltage Output: 0-10 VDC , P/N: SXWUI8V4X10001 5 KΩ MIN UI-8/AO-V-4-H, Module with HOA switches universal 9 8 10 11 12 inputs, 4 analog voltage outputs with Hand/Off/Auto override switches Contact Rating: 250 VAC ,3A P/N: SXWUI8V4H10001 30 VDC ,3A 4 TB-IO-W1, Terminal Base for I/O Module (Required for each I/O Module) P/N: Status SXWTBIOW110001 12 CO SXW UI-8/AO-V-4 7 8 UI3 RET UI4 UI5 RET UI6 UI7 RET UI8 13 16 19 22 15 17 18 20 Status Input Rating: 24 VDC UI1 RET UI2 14 , 2.4 mA Terminal base UI8 21 23 , 2.4 mA SXW DO-FC-8 24 Analog Outputs Digital Outputs 5 AO-V-8 Hand 6 7 8 Contact Rating: 250 VAC 30 VDC Status ,3A ,3A Auto 13 Off SXW UI-8/DO-FC-4 Schneider Electric One High Street, North Andover, MA 01845 USA 14 15 16 17 18 Telephone: +1 978 975 9600 19 20 21 22 23 24 Fax: +1 978 975 9698 www.schneider-electric.com/buildings Universal Inputs SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Input Rating: 24 VDC , 2.4 mA Status 1 2 3 4 5 6 7 8 9 10 11 12 Contact Rating: © 2012 Schneider Electric. All rights reserved. 1 Input channels Digital inputs 3 5 6 4 7 UI-16 UI-8/DO-FC-4 UI-8/DO-FC-4-H DC input power 21 8 Channel Universal Inputs with 4 Channel Digital Outputs, Form-C (UI-8/DO-FC-4, UI-8/DO-FC-4-H) Automation Server I/O Module The UI-8/DO-FC-4 and UI-8/ DO-FC-4-H are a combination I/O modules supporting 8 universal input channels and 4 digital output channels. These compact modules are ideal when an application requires a mix of point types. Analog and digital applications I/O Module UI-8/DO-FC-4 This module is ideal for any mix of temperature, pressure, flow, status points, and similar inputs in a building control system. The eight input channels supports a 12 bit A/D conversion. Counter applications Protection 28 V unipolar transient voltage suppressors on all inputs to protect against high voltage short duration transient events. Status indicators and overrides The front panel of the UI-8/AO-4 and UI-8/AO-4-H I/O modules includes a digital output indicator using a green LED. Additionally, the UI-8/AO-4-H module has Hand/Off/Auto (HOA) override switches with adjustable potentiometers for each output. Direct load applications The Form-C relays are designed for direct load applications for up to 3 A per output. The maximum counter frequency on all eight inputs with a minimum pulse width is 20 milliseconds. This input type is commonly used in energy metering applications. Supervised points are used for security applications where it is critical to know whether or not a wire has been cut or shorted. These events provide a separate indication of alarm and trouble conditions to the system. I/O Module UI-8/DO-FC-4-H Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. Security applications 22 UI-8/DO-FC-4 UI-8/DO-FC-4-H Automation Server I/O Module Specifications DC input power 12 bit Output channels 24 VDC, 1.9 W Accuracy 4 Input channels +/- (7 mV + 0.2 % of reading) Digital outputs Impedance Form C relay 100 kohm Digital inputs Terminals Current Contact Common (C), Normally Open (NO), Normally Accuracy Pulse width 20 ms minimum Pulse Width Reliability Range 100 ms minimum Open collector/open drain, 24 V, 2.4 mA, Ability to define the reliability level for upper and lower electrical limits. dry contact switch closure Resolution Counter 12 bit Internal pull-up resistor Range Accuracy 10 kohm termistors Open collector/open drain, 24 V, 2.4 mA, +/- (0.03 mA + 0.4 % of reading) 1 3 5 6 2 4 7 UI1 RET UI2 UI3 RET UI4 dry contact switch closure Impedance Pulse width 47 ohm 20 ms minimum Resistance LED polarity 10 ohm to 10 kohm +/- (7 + 4 x 10 -3 x R) (ohm) Red or green, software selectable 10 kohm to 5V 8 9 10 UI5 RET UI6 11 , 2.4 mA to 1 V 1.5 kohm Mechanical Weight including terminal base 0.304 kg (0.67 lb) UI Weight excluding terminal base 0.181 kg (0.40 lb) Reliability Terminal base Status UI Ability to define the reliability level for upper Detected resistor values and lower electrical limits. Open circuit, short circuit, contact open, Thermistor andUI1contact closed RET UI2 UI3 RET UI4 Range 3 2 4 5 6 7 8 9 UI5 RET UI6 10 11 12 UI7 RET UI8 UI13 RET UI14 UI15 RET UI16 20 19 21 22 12 bit Resistor range Supported thermistors 1 to 10 kohm. For a 2-resistor configuration, each UI 1.8 kohm. 10 kohm, and2 1 kohm Balco 1 3 2 3 4 5 6 , 2.4 mA UI9 RET UI10 UI11 RET UI12 UI13 RET UI14 UI15 RET UI16 16 17 18 9 8 10 11 switches 12 19 20 21 22 23 24 2 3 3 4 5 6 7 8 9 10 11 12 Contact Rating: 1 2 Digital Outputs 3 4 250 VAC 30 VDC ,3A ,3A 250 VAC ,3A P/N: SXWUI8D4H10001 4 5 6 7 8 9 VO RET CO VO RET CO 1 2 3 10 11 12 VO RET CO Current Output: 0-20for mA, each I/O Module) (Required 650 Ω MAX 4 Voltage Output: P/N: SXWTBIOW110001 0-10 VDC , Analog Outputs Universal Inputs TB-IO-W1, Terminal Base for I/O Module UI1 RET UI2 UI3 RET UI4 UI5 RET UI6 UI7 R 13 14 15 16 17 18 19 20 21 22 2 1 2 3 4 5 6 7 8 9 10 1 5 KΩ MIN Status Hand Auto Off SXW UI-8/DO-FC-4 VO RET CO VO RET CO VO RET CO 1 2 3 Analog Outputs Input Rating: 24 VDC UI3 RET UI4 UI5 RET UI6 UI7 RET UI8 13 14 15 16 19 22 23 24 1 2 3 4 10 11 12 17 18 20 21 , 2.4 mA Status SXW UI-8/AO-V-4 I-8/DO-FC-4 Universal Inputs Status -4-H SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC 1 30 VDC Hand/Off/Auto ,3A with override switches UI1 RET UI2 Schneider Electric One High Street, North Andover, MA 01845 USA 10 VO R Off 1 5 6 7 9 8 UI1 RET UI2 UI3 RET UI4 UI5 RET UI6 13 16 19 14 2 15 17 3 18 Digital Outputs Telephone: +1 978 975 9600 20 4 21 Input Rating: 24 VDC , 2.4 mA Rating: RET UI8 UI7 Contact 250 VAC ,3A 22 23 24 30 VDC ,3A Fax: +1 978 975 9698 UI-8/AO-V-4 2 9 Analog Outputs Universal Inputs 1 8 8Contact universal inputs, 4 digital Form C outputs Rating: 4 VO RET CO kohm to 5 V UI-8/AO-V-4-H 24 VDC 15 7 1.5 kohm to 1 V Input Rating: 7 1 P/N: SXWUI8D4X10001 24 1.0 (Balco) and 1.8 kohm thermistors Resolution 14 UI-8/DO-FC-4 SXW UI-16 10 0 to 10 Universal VDC Inputs 13 1 Internal pull-up resistor 1 2 3 Range 6 UI-8/DO-FC-4-H, I/O Module with HOA 10 kohm thermistors Connectors 23 Digital Outputs temperature sensor Status 5 Hand , 2.4 mA inputs, 4 digital Form C outputs 8 universal Auto 24 VDC Resolution Voltage 4 UI-8/DO-FC-4, I/O Module Input Rating: Series only, parallel only, and series and parallel UI 3 VO RET CO TB-IO-W1 Universal Inputs 2 VO RET CO SXW UI-16 switchUniversal combinations Inputs Analog inputs 1 VO RET CO Part numbers UI9 RET UI10 UI11 RET UI12 Rating: 5 V circuit, 1 or 2 resistors, monitoredInput -50 °C 14 (-5815 to16302 24 VDC , 2.4 mA to 150 13 17 °F) 18 resistor is assumed to have the same value. 1.0 (Balco) and 1.8 kohm thermistors Universal Inputs Supervised 1 12 UI7 RET UI8 24 VDC 10 kohm to 60 kohm +/- (0.4 + 7 x 10 -6 x R) (%) LED color 1500 VAC minimum, coil to contact Input Rating: UI-16 when the input is high or low Isolation UI-8/AO-V-4-H Software selectable, if the LED is activated UI-16 Closed (NC) +/-(0.03 mA + 0.4 % of reading) © 2012 Schneider Electric. All rights reserved. 8 www.schneider-electric.com/buildings VO R Universal Inputs 1 2 3 Hand VO RET CO Auto Off 4 5 6 VO RET CO 7 8 9 VO RET CO 10 11 12 VO RET CO Current Output: 0-20 mA, 650 Ω MAX UI1 RET UI2 UI3 RET UI4 UI5 RET UI6 UI7 R Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings © 2012 Schneider Electric. All rights reserved. This page intentionally left blank Schneider Electric One High Street, North Andover, MA 01845 USA SDS-AS-IOMODULES-A4.BU.N.EN.11.2012.0.00.CC Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings November 2012 gg © 2012 Schneider Electric. All rights reserved. All brand names, trademarks, and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice.