Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Field (physics) wikipedia , lookup
Electromagnetism wikipedia , lookup
Maxwell's equations wikipedia , lookup
History of electromagnetic theory wikipedia , lookup
Nordström's theory of gravitation wikipedia , lookup
Time in physics wikipedia , lookup
Partial differential equation wikipedia , lookup
5 Electric Sensitive Release Systems 5.1 Introduction Numerous synthetic polymers have been used to make electroactive hydrogels, such as polyvinyl alcohol/poly(sodium maleate-co-sodium acrylate) [1], acrylic acid/vinyl sulfonic acid copolymer [2] and sulfonated polystyrene [3]. In addition to synthetic polymers, some natural polyelectrolytes have been blended with synthetic polymers to prepare such hydrogels. For example, alginate/poly(methacrylic acid) [4], chitosan (CS)/polyaniline [5] and hyaluronic acid/poly(vinyl alcohol) (PVA) [6] hydrogels have also been reported in the literature. However, few reports were found on comparing pure natural polymer-based electroactive hydrogels with those made from synthetic and synthetic/natural polymer blend materials. It is well accepted that natural polymers have better biocompatibility and less latent toxic effect than most synthetic polymers [7–9], so pure natural polymer-based hydrogels would be more suitable for application in biomedical fields. Electrically responsive delivery systems are prepared from polyelectrolytes (polymers that contain a relatively high concentration of ionisable groups along the backbone chain) and are thus pH-responsive as well. Under the influence of an electric field, electroresponsive hydrogels generally deswell or bend, depending on the shape and orientation of the gel. The gel bends when it is parallel to the electrodes, whereas deswelling occurs when the hydrogel lies perpendicular to the electrodes. Several technologies are currently under investigation for the development of new drug-delivery devices that can achieve chronotherapy, specifically iontophoresis, infusion pumps and sonophoresis [10, 11]. In particular, electric-sensitive hydrogels with biocompatibility and biostability are more attractive as they are able to implement an isothermal energy conversion from chemical free energy directly to mechanical work, actuated by an external electric stimulus. As such, the mechanical energy is triggered by an electric signal. This results in one of their important functions as biosensors/actuators, in which the electricstimulus responsive hydrogels with fixed-charge groups can bend reversibly when they are subjected to an externally applied electric field [12]. Usually the electric-sensitive hydrogels are composed of electrolytes and a swellable and insoluble crosslinked polymer network with fixed-charge groups, as shown in Figure 5.1. When the hydrogels are immersed into a bathing solution under an externally applied electric 185 Stimuli Responsive Drug Delivery Systems: From Introduction to Application field, the hydrogels deform. They swell and bend due to the pressure difference of both hydrostatic and osmotic pressures, which are caused by the ionic concentration difference between the internal hydrogels and the external solutions. + + Mobile Ion – Fluid Filled Region Fixed Charge – – + + – – – Polymer Chain + Crosslink Undissociated + Ionizable Group Figure 5.1 Micro view of the hydrogel structure 5.2 Theories of Electrosensitive Release System 5.2.1 Donnan Equilibrium Theory The optimum condition for quick bending was determined by a simple method that identified the initial conditions based on Donnan equilibrium theory. The study [13, 14] investigated a parameter that determines an optimum condition of the content of the ionic group and the concentration of outer solution for high-performance electrodriven polymer hydrogel membranes. The electrolytic cell shown in Figure 5.2 was used to investigate the bending behaviour of poly(vinyl alcohol)-poly(2-acrylamide-2-methylpropane sulfonic acid) gel membrane. The membrane (20 mm long and 5 mm wide) was suspended at the centre between a pair of Pt-electrodes in the cell filled with a Na2SO4 aqueous solution. The membrane was equilibrated in the Na2SO4 aqueous solution (1–2 valent electrolyte solution) before the bending experiment. The time course of bending angle of the 186 Electric Sensitive Release Systems membrane was measured through monitoring the bending behaviour by a video camera. The bending angle θ of the membrane was calculated using Equation 5.1: y θ = 2 tan −1 x (5.1) where x and y are the positions of the free ends of the membrane on the x–y coordinate shown in Figure 5.2. D.C. power supply Pt electrode 30 mm 0 y θ 20 mm x (x, y) θ = 2 tan –1 (y/x) 40 mm 20 mm Hydrogel Membrane Figure 5.2 Schematic diagram of electrolyte cell for measuring the bending behaviour of the gel membrane. Reproduced with permission from W.Y. Gu, W.M. Lai and V.C. Mow, Journal of Biomechanical Engineering, 1998, 120, 169. ©1998, ASME [15] 187 Stimuli Responsive Drug Delivery Systems: From Introduction to Application The concentrations of ions in the membrane and in the outer solution are related by Equation 5.2, based on Donnan equilibrium theory. Cig F Δφ zi = exp − zi =K Cis RT (5.2) where K, Δφ, F, R, T and z denote Donnan ratio, Donnan potential, Faraday constant, gas constant, absolute temperature and valence of ion, respectively. Cig and Cis denote the concentrations of ions in the gel membrane (g) and in the outer solution (s). The subscript i means the species of ion [i = A (counterion), B (co-ion), H (proton), OH (hydroxide ion)]. The electrically neutral condition should be satisfied simultaneously in both phases (in the gel membrane and the outer solution), as expressed by Equations 5.3 and 5.4, respectively: the outer solution): z A C Ag + CHg − − z B CBg + COHg + CM (5.3) z A C As + CHS = − z B CBs + COHs (5.4) where CM is the concentration of ionic group within the gel membrane suspended in the electrolyte solution. The chemical equilibrium relation of water is: K w = CHs COHs = CHz COHg (5.5) pH in the outer solution is 7 in this system under study (CHs = COHs). The Donnan ratio K in a membrane-electrolyte solution system is calculated by Equation 5.6, derived from Equations 5.2, 5.3 and 5.6: 188 Electric Sensitive Release Systems (− K If ZA 1 + K ZB ) Z A Z B CS + K − CHS − CM = 0 K z A = zB 1 ZA K + ZB K 1 z A CS + K − CHS − CM = 0 K (5.6) where Cs is the concentration of outer electrolyte solution. Experiments showed the bending behaviour of the electrodriven hydrogel membranes and provided a method to evaluate optimum conditions for designing a high-performance membrane. The following results were obtained from the experimental part: • The bending rate depends on the initial condition of the system for a long period, which means that the initial condition of the system dominates the bending behaviour. The bending rate is linearly controlled by the intensity of the applied electric field. • Each membrane has a maximum bending rate at a specified concentration of outer solution. The concentration of outer solution at the maximum bending rate shifts to a higher concentration region of outer solution with increasing concentration of ionic group. • The bending rate is correlated with the thickness of membrane, by the following equation beyond 2.5 V/cm: Based on these experimental results, the inverse of the Donnan ratio (1/K) is the effective simple parameter to determine the optimum condition of the concentration of the outer solution Cs and the content of ionic group CM for the quick bending. The bending rate of the electrodriven polymer hydrogel membrane can be predicted by both the changeability of the swelling volume of the membrane and the conductivity in electrolyte solution at the initial condition of the system. The electrolyte containing a univalent counterion is effective for the quick bending of the membrane. 189 Stimuli Responsive Drug Delivery Systems: From Introduction to Application 5.2.2 Mixture Theory A mixture theory [15] was developed to model the mechano-electrochemical behaviours of charged-hydrated soft tissues containing multielectrolytes. The mixture is composed of n + 2 constituents (1 charged solid phase, 1 non-charged solvent phase and n ion species). The three main objectives of the study are: • To develop a more general mixture theory to describe the transport of multielectrolytes through a charged-hydrated tissue, based on the triphasic theory of Lai and co-workers [16]. • To study the electromechanical kinetic properties of such tissues associated with a multielectrolyte transport process. • To investigate the effects of ion exchange on tissue swelling and solvent transport. It is emphasised that the theory has been developed specifically to address an important hypothesis in the articular cartilage literature, i.e., the kinetics of transport of multiions through such tissues is governed by the tissue fixed-charge density. Since many biological membranes have similar physicochemical characteristics, the theory can be used to derive the well-known formula [17] for the resting cell membrane potential. In order to simplify the discussion, we confine ourselves to the study of hydrated, isotropic and soft tissues under infinitesimal deformation, although the theory can be easily extended to describe anisotropic and inhomogeneous materials undergoing finite deformation [16]. 5.2.3 The Generalised Triphasic Theory The theory presented in this section is an extension of the triphasic theory for articular cartilage developed by Lai and co-workers [16]. In the following model a chargedhydrated tissue is a continuum mixture consisting of three phases: • a solid phase, • a solvent phase, and • n ion phases (species). Each ionic species could be multivalent. In general, the tissue has a total of n + 2 constituents. Each phase is assumed to be intrinsically incompressible. The solid phase 190 Electric Sensitive Release Systems and ion phase are charged while the solvent phase is electroneutral. The tissue as a whole must be electrically neutral. A generalised triphasic theory composed of n + 2 species has been developed for describing mechano-electrochemical behaviours of charged-hydrated soft tissues with multielectrolytes. This theory is consistent with and subsumes many previously derived mixture and phenomenological transport theories pertaining to specific aspects of charged-hydrated tissues [16–21]. From general analyses using this theory, it is shown that three types of force are involved in the transport of ions and solvent through such materials: • a mechano-chemical force (∇P; hydraulic and osmotic pressures) • an electrochemical force (∇Nα; gradient of Nernst potential) • an electrical force (∇Ψ) These general results indicate that mechanical force (part of mechano-chemical force) plays an equally important role in modulating transport process and membrane potential as do the electrochemical forces and the electrical force in charged permeable tissues. Further, the analyses also provide the results of the three types of mechanoelectrokinetic coefficients required to characterise solvent and ion transport through charged-hydrated tissues: • the hydraulic permeability (ko) • the mechano-electrochemical coupling coefficients (bα) • the ionic conductance matrix (hαβ) These material coefficients governing the transport processes are nonlinearly related to the tissue, fixed charge density (FCD), tissue hydration, ion concentrations and the frictional coefficients (or diffusion coefficients). These general results support our hypothesis that tissue FCD is a primary determining factor governing solvent and ion transport through articular cartilage. Finally, the problem of Na+ and Ca++ exchange through cartilage (an important physiologic process; [22]) was solved specifically to illustrate how multielectrolyte solution transport occurs within a finite-thickness specimen with swelling. The strain, concentration, flux and pressure fields within the tissue were also calculated. Many important phenomena associated with passive transport of ions and solvent in charged-hydrated soft tissues, such as membrane potential, streaming potential and current, and anomalous osmosis can be described by this generalised triphasic theory. The theory can also be applied to describe the cell membrane potential and cell membrane selectivity in terms of ion conductance, though 191 Stimuli Responsive Drug Delivery Systems: From Introduction to Application the present continuum theory is unable to provide more information concerning the mechanism of this selectivity at a microscopic level (e.g., ion channels). 5.2.4 Refined Multi-effect Coupling Electric-Stimulus (rMECe) Model A multiphysics model is presented by Li [23–28] for simulation of kinetics of the smart hydrogels subject to an externally applied electric field, especially for analysis of the transient deformation of the hydrogel. The model termed the multi-effect coupling electric stimulus (MECe) takes account of the coupled chemo-electromechanical multiphysics domains and the multiphase effect of polymeric network and interstitial liquid as well as ionic species. 5.2.4.1 Theory and Formulation Due to mass conservation, the change in number of moles of diffusive species k (in a volumetric space) with respect to time t can be characterised by the difference between the fluxes entering and leaving the reference volume. The Nernst–Planck type of continuity equations can be written as [29] as seen in Equation 5.7: ∂ck ∂c + div (J k ) = k + ∂t ∂t z F div − [Dk ]. grad (ck ) + k ck grad (ψ ) = 0 RT (k = 1, 2,....., N ) (5.7) where Jk, [Dk], ck and zk are the flux (mM/s), diffusivity tensor (m2/s), concentration (mM) and valence number of the kth diffusive ionic species. N is the number of diffusive ionic species and c the electrostatic potential. F, R and T are the Faraday constant (9.6487 × 104 C/mol), universal gas constant (8.314 J/mol K) and absolute temperature (K), respectively. To describe the spatial distribution of the electric potential in the domain, the Poisson equation, derived from Gauss Law, is written as seen in Equation 5.8: 192 Electric Sensitive Release Systems ∇ 2ψ = − F N ∑ zk ck + z f c f εε 0 k , (5.8) where ε is the relative dielectric constant of the surrounding medium, ε0 the vacuum permittivity or dielectric constant (8.85418 × 10–12 C2/Nm2) and cf is the density of the fixed charge groups bound to the polymeric chains of the hydrogel. The first contribution of the present rMECe model is the reformulation of the fixed charge density for incorporating the effect of externally applied electric field. Based on the triphase mixture theory [16] a hydrogel is defined as a three-dimensional crosslinked polymeric hydrophilic network consisting of solid matrix, interstitial water and ionic phases. The corresponding saturation equation can be written as seen in Equation 5.9: ∑ α = s , w, k φ α = 1, (5.9) where φα (α = s, w, k) represents the volume fractions of the solid, water and ion phases, respectively. The volume fraction of the water phase is given by Lai and coworkers [16], see Equation 5.10: φw = 1− φ0s , 1 + tr ( E ) (5.10) where E is the elastic strain vector of solid matrix phase and φs0 is the volume fraction of the solid phase at reference configuration. Compared with φs and φw, φk is negligibly small. The saturation Equation 5.9 can be simplified to: φ s + φ w = 1, (5.11) and the corresponding saturation equation at reference configuration is written as: as seen in Equation 5.12: φ0s + φ0w = 1. (5.12) 193 Stimuli Responsive Drug Delivery Systems: From Introduction to Application Based on Equations 5.10 and 5.12, the volume fraction of the current water phase is obtained by Equation 5.13: φ0s 1 − φ0w tr ( E ) + φ0s φ = 1− = 1− = 1 + tr ( E ) 1 + tr ( E ) 1 + tr ( E ) w (5.13) By the triphasic theory [16] and using Equation 5.7, the fixed charge density is finally derived as follows in Equation 5.14: cf = φ0w c 0f = φ0w c 0f φ w [1 + tr ( E ) ] φ0w + tr ( E ) = c 0f 1 + tr ( E ) / φ0w (5.14) As the second contribution of the rMECe model, the mechanical governing equation is treated in finite deformation, instead of small deformation. In consideration of chemo-electromechanical coupling effects, the electric-stimulus-responsive hydrogels undergo large deformation when the applied electric voltage is relatively high, in which case the linear theory does not provide sufficiently accurate computation. This results from the fact that the difference between the initial (reference) and deformed configurations cannot be neglected as is done for the case of linear elasticity. For geometrically nonlinear analysis, the governing equations of large deformation using a total Lagrangian description are given as seen in Equations 5.15-5.17: ∇.P = ∇.( FS ) = 0 in Ω, u = G in Γ g , P.N = H in Γ h , (5.15) (5.16) (5.17) where F is the deformation gradient tensor, G is the specified displacement vector on the boundary portion Γg, H is the surface traction vector on the boundary Γh, N is the unit outward normal vector, u is the displacement vector from the initial configuration 194 Electric Sensitive Release Systems X to the deformed configuration x. P is the first Piola–Kirchhoff stress tensor that is a kind of expatriate, living partially in the deformed (current) configuration x and partially in the reference configuration x, where x = X + u.P). As P is immeasurable and asymmetrical, the second Piola–Kirchhoff stress tensor S is required because S is symmetric and is often used as the stress measure as seen in Equation 5.18: S = CE − posmotic I . (5.18) where C is the material tensor, posmotic is the osmotic pressure, I is the identity tensor and E is the Green–Lagrangian strain tensor used as strain measure. Substituting Equation 5.18 into Equation 5.15, the large deformation governing equation of the hydrogel is obtained by Equation 5.19: ∇.[F (CE − posmotic I ) ] = 0. (5.19) However, when the applied electric voltage is low, the hydrogels have small deformation. Then the linear theory satisfies sufficiently the computational accuracy requirement, and Equation 5.19 is thus reduced to Equation 5.20: ∇.σ = ∇.(λs tr ( E ) I + 2 µ s E − posmotic I ) = 0, (5.20) where σ is the Cauthy stress tensor. λs and μs are the Lamé coefficients of solid matrix. 5.2.4.2 Boundary and Initial Conditions − for The computational domain of the ionic concentrations c−k and electric potential ψ Equations 5.20 and 5.21 is defined as covering both the hydrogel and surrounding − are imposed bath solution. As such, the boundary conditions of the unknown − c k and ψ at the two electrodes located at the ends of the bath solution as illustrated in Figure 5.3: 195 Stimuli Responsive Drug Delivery Systems: From Introduction to Application D h Hydrogel a 0 b X Solution Xgel 0 L Cathode Anode Figure 5.3 Diagram of a hydrogel strip immersed in a bath solution under applied electric field, where the whole computational domain is defined as the X-coordinate system and the hydrogel domain as the X gel-coordinate system. Reproduced with permission from W.Y. Gu, W.M. Lai and V.C. Mow, Journal of Biomechanical Engineering, 1998, 120, 169. ©1998, ASME [15] _ _ C | Anode = C |Cathode = C * ψ | Anode = 0.5Ve and ψ |Cathode = −0.5Ve (5.21) (5.22) where c−* is the initial salt concentration of the bath solution and v−k is the applied voltage. However, the computational domain of the fluid pressure p− and hydrogel displacement u− for Equations 5.22 and 5.23 covers the hydrogel region only. The corresponding boundary conditions are required at both the interfaces between the hydrogel and surrounding solution. Based on the assumption that, at equilibrium state, the chemical potentials of fluid and ion phases inside the hydrogels should be 196 Electric Sensitive Release Systems equal to those outside the hydrogels, the boundary condition of the fluid pressure − P at the hydrogel–solution interfaces is given as: p int erface = RT (C + in −int erface +C − in −int erface −C + out −int erface −C − out −int erface ) − p0 (5.23) where c−kin-interface and c−kout-interface (k = +, −) are the ionic concentrations within the hydrogels near the interfaces and within the surrounding bath solution near the interfaces, respectively. p0 denotes the fluid pressure at reference configuration. In terms of the mechanical state of the mixture phase, the boundary condition of the hydrogel displacement u−at the hydrogel–solution interface can be written as seen in Equation 5.24: (3λs + 2 µ s ) ∂u int erface = β RTcref p int erface ∂x (5.24) To implement the transient simulation for kinetics of the electric-sensitive hydrogels, initial conditions are required. It is assumed here that the initial hydrogel is in the equilibrium state when the effect of the bath solution is considered only and no external electric field is applied. This equilibrium state will be taken as initial condition for transient simulation. Corresponding steady-state computational results can thus be used as the initial conditions as seen in Equations 5.25-5.28: transient c initial ψ initial p initial u initial transient transient transient steady = c v =0 (5.25) (5.26) (5.27) steady = ψ v =0 steady = p v =0 steady = u v =0 (5.28) 197 Stimuli Responsive Drug Delivery Systems: From Introduction to Application c steady steady transient transient transient steady transient where , , and initial v =0 initial initial v = 0 initialv = 0 ψ= c p= ψ =up steady = u v =0 represent the steady-state computational results without the externally applied electric field. 5.2.4.3 Discretisation of the Transient Governing Equations of the MECe Model A meshless numerical method, termed the Hermite-cloud method [30, 31], is used for transient solution of the nonlinear partial differential governing equations of the MECe model. The Hermite-cloud method constructs the Hermite-type interpolation functions and employs the point collocation for discretisation of the governing equations to directly compute the approximate solutions of both unknown functions and firstorder derivatives [30, 31]. By the Hermite-cloud method, an unknown continuous real function f(x,y) can be expressed approximately by Equation 5.29: Ns NT NT f ( x, y ) = ∑ N n ( x, y ) f n + ∑ x − ∑ N n ( x, y ) xn M m ( x, y ) g xm n =1 m =1 n =1 NT Ns + ∑ y − ∑ N n ( x, y ) yn M m ( x, y ) g ym m =1 n =1 (5.29) where Nn(x,y) and Mn(x,y) are defined as the shape functions of the unknown function f(x,y) and corresponding first-order differential functions gx(x,y) and gy(x,y), respectively, which are simply polynomials in x and y. fn denotes the unknown point value of f(x,y) at the nth discrete point, gxm and gym the unknown point values of gx(x,y) and gy(x,y) at the mth discrete point. NT and NS are total numbers of discrete points scattered within the computational domain. By the θ-weighted finite difference scheme (0.5 < θ < 1.0) [32], the equation is discretised first in time t domain as: 198 Electric Sensitive Release Systems k k C ( n +1) − C ( n ) k 2 k ∂C ( n +1) ∂ψ ( n +1) ∂ 2ψ ( n +1) k ∂ C ( n +1) k k θ + + α α z z C . . n + ( 1) 2 2 ∂ x.∂ x ∂x ΔtDk ∂ x = 2 k 2 Lref ∂2 C k ∂C ( n ) ∂ψ ( n ) k ∂ ψ (n) (n) k k +(1 − θ ) + + α z α z C . . ( ) n 2 ∂ x2 ∂ x.∂ x ∂ x (5.30) where the subscript n denotes time t = tn and Δt = tn+1 – tn is time step. The model is composed of coupled nonlinear partial differential governing equations, and it has been examined for kinetic study by comparison with published experiments. The kinetics of diffusive ionic species concentration is simulated well and is in good agreement with the published steady-state simulation. Influences of important parameters are discussed in detail, including the externally applied electric voltage, initially fixed charge density and surrounding bath solution concentrations as well as the displacement of the hydrogel. By the present transient simulations, it is concluded that the smart hydrogels have the capability of responding to the externally applied electric field in short time. 5.3 Measurement of Bending Angle Jing Shang and co-workers [33] prepared a natural amphoteric polyelectrolyte hydrogel film by solution blending of CS and its derivative carboxymethyl chitosan (CMCS) and crosslinked with glutaraldehyde, compared to the CS/carboxymethyl cellulose (CMC). CS/CMCS hydrogels show a faster bending rate, a larger bending angle and a higher tensile strength, which suggests great potential for their application in natural polymeric electroactive hydrogels. The authors previously prepared CS/ CMC hydrogels [34], which exhibit a good electromechanical response over a wide range and could change their bending direction depending on the pH of the buffer solution. A schematic diagram of the equipment used for studying the electrical response of hydrogels is shown in Figure 5.4. All hydrogel strips (10 mm long and 2 mm wide) were first swollen to equilibrium in an electrolyte solution (Britton–Robinson pH buffer solution) to be used later in the bending experiments; the thickness of the hydrogel in a swollen state was 0.145 mm (pH = 6). Two parallel carbon electrodes, 50 mm apart, were immersed in the electrolyte solutions and the hydrogel strip under investigation was mounted centrally between them. Upon application of a 199 Stimuli Responsive Drug Delivery Systems: From Introduction to Application direct current (DC) electric field, the degree of bending, q, was measured by reading the angle of deviation from the vertical position. The authors define the value of the bending angle as being positive when the hydrogel bends toward the anode and negative when it bends toward the cathode. The bending behaviour was recorded with a digital camera. carbon electrodes electrolyte solution θ hydrogel bending angle Figure 5.4 Schematic diagram of the apparatus for testing the bending behaviour of hydrogels The CS/CMCS hydrogels exhibit better overall mechanical properties and electrical sensitivity, suggesting their great potential for microsensor and actuator applications, especially in the biomedical field. Natural amphoteric CS/CMCS hydrogels were prepared by a simple solution blending of two natural polymers, CS and its derivative CMCS. Such an amphoteric hydrogel gave a fast mechanical response in an electric field (bending toward an electrode) in different electrolyte solutions and over a wide pH range. The bending behaviour of the hydrogels was different in different pH buffer solutions, i.e., when pH ≤ 7, it bent toward the anode, but when pH > 7 it bent toward the cathode. The equilibrium bending angle of CS/CMCS hydrogels was influenced 200 Electric Sensitive Release Systems by pH, ionic strength, electric strength, the thickness of the hydrogel film and content of crosslinking agent in the hydrogel. The equilibrium bending angle of the hydrogel reached a maximum that was over 90° in the buffer solution at pH = 6 with 0.2 M ionic strength. In addition, the authors found that thin hydrogel films and optimised crosslinking were favourable to enhance the electrical sensitivity. The CS/CMCS hydrogel shows better overall mechanical properties and electrical sensitivity than the CS/CMC hydrogel, which indicates its great potential for application in artificial muscles, microsensors and actuators, particularly in biomedical fields because all the materials are from CS, an excellent natural material. 5.4 Application of Electrosensitive Release System The poly(3,4-ethylene dioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) entangled in the polyacrylamide (PAAm) network by the formation of a semi-interpentrating network (semi-IPN) on hydrogel performance. In addition, PAAm networks with good mechanical properties have been obtained [35]. The presence of PEDOT/ PSS increased the ionic conductance of swollen semi-IPN hydrogels substantially. Electrochemical experiments demonstrated that PAAm-PEDOT/PSS hydrogel is electrochemically stable and presents reversible responses to electrochemical stimuli. Scanning electron microscopy images revealed that the morphology of conducting hydrogels changed significantly with the entrapment of PEDOT/PSS. The data from Wu [7] and mechanical properties revealed that the presence of PEDOT/PSS within the hydrogels changes the hydrophobicity and, consequently, the compaction of the network at lower crosslinking density. These conducting hydrogels presented good mechanical properties, which were driven by the amounts of acrylamide (AAm) and N,N-methylene bisacrylamide (MBA) in the hydrogel synthesis feed solution. On the other hand, the presence of PEDOT/PSS increased ionic conductance substantially, and it is more significant in highly swollen semi-IPN hydrogels. It was suggested that the water molecules and the PEDOT/PSS chains in the hydrogel help ionic diffusion through the polymer networks by increasing ionic conductance. In addition, as the amounts of AAm and MBA used in the hydrogel synthesis feed solutions may be controlled, this process allows tailoring hydrogel ionic conductance and mechanical properties. The results shown in this work indicate that the hydrogels obtained have potential for further tests as conducting hydrogel membranes, e.g., sensors and electrodes. Electrochemical experiments have demonstrated that PAAm-PEDOT/PSS hydrogel has good electrochemical stability and reversible response to electrochemical stimuli. These attributes make it attractive for capacitor applications. Ramanathan and Block [36] evaluated and characterised the use of CS gels as matrices for electrically modulated drug delivery. In electrification studies, release-time profiles for neutral (hydrocortisone), anionic (benzoic acid) and cationic (lidocaine 201 Stimuli Responsive Drug Delivery Systems: From Introduction to Application hydrochloride) drug molecules from hydrated CS gels were monitored in response to different milliamperages of current as a function of time. Likewise, chondroitin 4-sulfate hydrogels were examined by Jensen and co-workers [37] as potential matrices for the electrocontrolled delivery of peptides and proteins. Kim and co-workers [38] synthesised an interpenetrating polymer network (IPN) hydrogel composed of PVA and CS which exhibited electrosensitive behaviour. They investigated the response of the IPN hydrogel in electric fields. A swollen PVa/CS/IPN was placed between a pair of electrodes and bending behaviour in response to the applied electric field was noted. The bending angle and the bending speed of the PVA/CS IPN increased with increasing applied voltage and concentration of NaCl aqueous solution. Synthetic as well as naturally occurring polymers, either alone or in combination, have also been used. Examples of naturally occurring polymers include hyaluronic acid, chondroitin sulfate, agarose, xanthan gum and calcium alginate. The synthetic polymers are mostly methacrylate and acrylate derivatives such as partially hydrolysed polyacrylamide, polydimethyl aminopropyl acrylamide, and so on. Electrically induced anisotropic gel deswelling was first explained by Tanaka and coworkers [39], who suggested that the electric field produces a force on both the mobile counterions and the immobile charged groups of the gel’s polymeric network. For example, in partially hydrolysed polyacrylamide gels fixed to one of the electrodes, the mobile H+ ions migrate toward the cathode while the negatively charged immobile acrylate groups in the polymer networks are attracted toward the anode. The anionic polymeric gel network is pulled toward the anode. The pull creates a uniaxial stress along the gel axis, the stress being greatest at the anode and smallest at the cathode. This stress gradient is thought to contribute to the anisotropic gel deformation. When the gel is not fixed to either electrode, the attractive forces between the immobile negative charges of the polymer network and the anode can result in translational movement of the gels towards the anode. In a recent study by Bajpai and co-workers [40], polyaniline was impregnated into a macromolecular matrix of PVA-g-poly(acrylic acid) (PAA) and electrical conductivity and electroactive behaviour of the resulting nanocomposite were studied. Kishi and co-workers [41] prepared drug-delivery devices responding to electrical stimuli to alter gel-swelling behaviour. The gels responded to the on-off stimulus of electrical currents, which induced the gel swelling-shrinking that contributes to the release of drug molecules. The researchers prepared poly(sodium acrylate) microparticle gels containing pilocarpine as a model drug. During application of a direct electric current, the pilocarpine release increased in a current-dependent manner. However, the pilocarpine release did not stop upon termination of the electrical stimulus, since the prepared gels themselves maintained a highly swollen state. Thus, a complete on-off release regulation of drugs cannot be achieved with this polymer gel system. 202 Electric Sensitive Release Systems The electromechanical behaviour of crosslinked strong acid hydrogels was investigated in different salt solutions and in a 1.6 V/cm DC electric field [3]. The sulfonated polystyrene-based copolymer networks were observed to bend toward the cathode when they were preequilibrated in the corresponding salt solutions. A polythiophenebased conductive polymer gel actuator was reported to show expansion/contraction behaviour in response to an applied potential [42]. The axial pressure generated by the expansion of the gel against a fixed wall was measured, which demonstrated that the generated closure pressures could be utilised as a small actuator valve. In most cases, electric field responsive polymer networks are based on electrically driven motility. On the other hand, some neutral polymer gels were reported to show electric field sensitivity. Weakly crosslinked poly(dimethyl siloxane) gels containing finely distributed electric field sensitive particles (TiO2 particle) showed a significant and quick bending in silicon oil [43]. The mechanism of this responsiveness was that the forces acting on the particles, which could not leave the gel networks, directly caused the locomotion or the deformation of the gel. Maleic anhydride was used to prepare polyvinyl alcohol/poly(sodium maleate-cosodium acrylate) hydrogels by a repeated frost–defrost process because of its higher charge density and potential electric stimuli sensitivity [1]. The bending angle was measured in a non-contact electric field using carbon as plate electrodes. It was found that the bending angle was dependent on various factors, including composition of hydrogel, concentration of NaCl solution, types of electrolyte solution and electric voltage. It exhibited that the bending angle increased when the concentration of NaCl solutions and the electric voltages increased. An abnormal bending direction was observed, and it was affected not only by the kinds of hydrogels, but also by the exterior variations. The hydrogel showed good reversibility in on-off electric field and could be a candidate for practical application. Kwon and co-workers [44–46] prepared crosslinked poly(2-acrylamide-2methylpropane sulfonic acid-co-butyl methacrylate) (P(AMPS-co-BMA)) hydrogels and evaluated the applicability of these hydrogels for electrical stimuli-responsive drug-delivery devices. They used a cationic drug molecule, edrophonium chloride, within the negatively charged hydrogel. Rapid drug release from the hydrogels resulted from an application of electric fields through the ion exchange between positively charged drug molecules and protons at the cathode. The squeezing effects arising from the electric field application induced rapid drug release from the gels, which increased as the voltages increased in a dose-dependent manner. Using the P(AMPSco-BMA) hydrogels, an on-off drug release regulation was achieved under an on-off application of electric current. Kwon and co-workers [47] further investigated the electric current-induced release of anionic heparin from a positively charged polyallylamine polyion complex. Rapid 203 Stimuli Responsive Drug Delivery Systems: From Introduction to Application structural changes and an apparent dissociation of the polyion complex occurred upon application of an electric current. During the electric current application, the positively charged poly allylamine was neutralised at the cathode owing to the microenvironmental pH changes, and apparent dissociation of the polyion complex occurred. Although bioactive heparin was released by electric current application, polyallylamine was also released. Such positively charged molecules are incompatible in vivo, and these complications must be addressed before clinical applications can be considered. Hsu and Block [48] studied electrokinetic phenomena in three types of anionic gels (agarose, agarose-carbomer 934P and agarose-xanthan gum) under an applied electric current for electrically modulated drug delivery. It was shown that electrical current strength and gellant content could influence both syneresis and drug migration. These findings reported by the two research groups may give a practically useful insight into the application of hydrogels to transdermal delivery assisted by electroportion, iontophoresis or sonophoresis. Electrosensitive hydrogels, which are basically pH-sensitive hydrogels, are able to convert chemical energy to mechanical energy [49]. These systems can serve as actuators or artificial muscles in many applications. All living organisms move by the isothermal conversion of chemical energy into mechanical work, e.g., muscular contraction, and flagellar and ciliary movement. Electrically driven mobility and ciliary movement has been demonstrated using weakly crosslinked poly(2-acrylamido2-methylpropanesulfonic acid) hydrogels. In the presence of positively charged surfactant molecules, the surface of the polyanionic hydrogels facing the cathode is covered with surfactant molecules reducing the overall negative charge. This results in local shrinkage of the hydrogel leading to bending of the hydrogel. Application of an oscillating electrode polarity could lead the hydrogels to quickly repeat its oscillatory motion, leading to a worm-like motion [50]. Reversible change in optical properties of ionic polymeric gels, 2-acrylamido2-methylpropane sulfonic acid and PAA plus sodium acrylate crosslinked with bisacrylamide, under the effect of an electric field is reported. The shape of a cylindrical piece of the gel, with flat top and bottom surfaces, changed when affected by an electric field [51]. The top surface became curved and the sense of the curvature (whether concave or convex) depended on the polarity of the applied electric field. The curvature of the surface changed from concave to convex and vice versa by changing the polarity of the electric field. By the use of an optical apparatus, focusing capability of the curved surface was verified and the focal length of the deformed gel was measured. The effect of the intensity of the applied electric field on the surface curvature and, thus, on the focal length of the gel are tested. Different mechanisms are discussed; either one or a combination of these may explain the surface deformation 204 Electric Sensitive Release Systems and curvature. Practical difficulties in the test procedure and the future potential of the electrically adaptive and active optical lenses are also discussed. These adaptive lenses may be considered as smart adaptive lenses for contact lenses or other optical applications requiring focal point undulation. Toshihiro Hirai and co-workers [52] reported that non-ionic gel of PVA swollen with dimethyl sulfoxide responds to an electric field rapidly with a large and reversible deformation, which includes a spherical bending motion to the anode side and a contraction in the direction of an electric field. The electrically induced strain in the polymer gel has been suggested to be due to electrically induced unidirectional movement of solvent in the gel. The chemically crosslinked polymer gels used here, which had only about 2 wt% of polymer content and a much larger amount of solvent in the gel networks, were a good elastic body to suffer a large mechanical deformation. Here, we discussed mechanical properties of the gel under and out of the application of an electric field, and also the interaction between the polymer network and solvent. The electrically induced deformation was discussed, as well, on the proportionality of strain to the square of an electric field for both the bending motion to the anode side and the contracting motion in the field direction. Furthermore, we drove out the electrically induced solvent force in the gel under various conditions, and demonstrated that the electroactive non-ionic gel can be used in some mechanical devices. Composites of monodomain nematic liquid crystal elastomers and a conducting material distributed within their network are shown to exhibit large deformations, i.e., contraction, expansion, bending with strains of over 200% and appreciable force, by Joule heating through electrical activation [53]. The electrical activation of the conducting material induces a rapid Joule heating in the sample leading to a nematic to isotropic phase transition where the elastomer of dimensions 32 mm × 7 mm × 0.4 mm contracted in less than a second. The cooling process, isotropic to nematic transition where the elastomer expands back to its original length, was slow and took 8 seconds. The material studied here is a highly novel liquid crystalline co-elastomer, invented and developed by Heino Finkelmann and co-workers at Albert-Ludwigs-Universität in Freiburg, Germany. The material is such that the mesogenic units are in both the side chains and the main chains of the elastomer. This co-elastomer was then mechanically loaded to induce a uniaxial network anisotropy before the crosslinking reaction was completed. These samples were then made into a composite with a conducting material such as dispersed silver particles or graphite fibres. The final samples were capable of undergoing more than 200% reversible strain in a few seconds. Sun and Mak [54] prepared a smart hydrogel fibre based on CS/poly(ethylene glycol). The dynamics of this hydrogel fibre in response to electric stimulation is reported. The effects of a number of factors have been systematically studied, including the fibre diameter, concentration of the crosslinking agent, electric potential imposed across the fibre, pH and ionic strength of the bath solution. Fibre deformation is expressed 205 Stimuli Responsive Drug Delivery Systems: From Introduction to Application in terms of the curvature at the mid length of the fibre for various times. The amount of bending to a given extent within a given time period is used to describe the rate of cyclic deformation. Our experimental results show a stable reversibility of bending behaviour under the applied electric field. The bending curvature is proportional to the intensity of the applied electric potential. Although adequate mechanical properties are maintained, the rate of deformation can be improved via the adjustment of a number of the aforementioned extrinsic factors. These observations are interpreted in terms of fibre stiffness, fixed charge density and swelling pressure, which depend on the hydrogel equilibrium states in different pH and ionic environments along with the electrochemical reactions under the electric field. PVA and PAA composite fibres were prepared via solution spinning and, subsequently, semi-IPN were obtained by crosslinking the fibres with glutaraldehyde [55]. The hydrogel fibres exhibited bending behaviour under DC electric stimulation. The effects of a number of factors have been systematically studied, including the PAA content within the network, electric voltage imposed across the fibre, the fibre diameter, concentration of the crosslinking agent, pH and ionic strength of the bath solution. Our experimental results show a stable reversibility of bending behaviour under the applied electric field. The degree of bending at equilibrium and the bending speed of the hydrogel fibre increased with the intensity of the applied electric voltage and the PAA content having negatively charged ionic groups within the semi-IPN. The electroresponsive behaviour of the present semi-IPN hydrogel fibre was also affected by the aforementioned extrinsic factors. These observations are interpreted in terms of fibre stiffness, fixed charge density and swelling pressure, which depend on the hydrogel equilibrium states in different pH and ionic environments together with the electrochemical reactions under DC electric field. Semi-interpenetrating polymer networks (semi-IPN) composed of CS and PAAm hydrogels have been prepared, and the effect of changing pH, temperature, ionic concentration and applied electric fields on the swelling of the hydrogels was investigated [56]. The swelling kinetics increased rapidly, reaching equilibrium within 60 min. The semi-IPN hydrogels exhibited a relatively high swelling ratios of 385– 569% at T = 25 °C. The swelling ratio increased with decreasing pH below pH = 7 due to the dissociation of ionic bonds. The swelling ratio of the semi-IPN hydrogels was pH, ionic concentration, temperature and electric field dependent. Differential scanning calorimetry was used to determine the volume of free water in the semi-IPN hydrogels, which was found to increase with increasing PAAm content. IPN hydrogel composed of PVA and poly(diallyldimethylammonium chloride) (PDADMAC) exhibited electrical-sensitive behaviour [57]. The PVA/PDADMAC IPN hydrogel was synthesised using the sequential IPN method. The swelling behaviour of the IPN hydrogel was studied by immersion of the gel in aqueous NaCl solutions 206 Electric Sensitive Release Systems at various concentrations and pH. The swelling ratio decreased with an increase in NaCl concentration. The stimuli response of the IPN hydrogel in electric fields was also investigated. When swollen IPN hydrogel was placed between a pair of electrodes, the IPN exhibited bending behaviour upon the application of an electric field. The IPN also showed stepwise bending behaviour depending on the electric stimulus. The bending mechanism of an electrodriven ionic polymer hydrogel membrane was investigated in terms of the concentration of ionic groups and the valence of ionic species within the hydrogel membrane. It was elucidated that the distribution of the ionic concentration played an important role in the bending behaviour of the membrane [58]. IPN composed of PVA and PAA exhibited electrical-sensitive behaviour [59]. PAA as an initial network was prepared inside a PVA solution using ultraviolet (UV) irradiation; then, PVA networks as a secondary network were formed by a repetitive freeze–thawing process. Their mechanical properties were influenced by the swelling ratio, crosslinking by UV radiation and a freeze–thawing process, and intermolecular force by hydrogen bonding. When a swollen PVA/PAA IPN was placed between a pair of electrodes, the IPN exhibited bending behaviour upon the applied electric field. The equilibrium bending angle (EBA) and the bending speed of the PVA/PAA IPN increased with the applied voltage and the content of the PAA network having negatively charged ionic groups within the IPN. The electroresponsive behaviour of the present IPN was also affected by the electrolyte concentration of the external solution. Particularly, IPN37 showed a maximum EBA when the critical ionic strength was 0.1. Anisotropic deswelling of the IPN was observed in a direct contact with a pair of electrodes under aerobic conditions. The PVA/PAA IPN also showed stepwise bending behaviour depending on the electric stimulus. References 1. Y. Gao, S. Xu, R. Wu, J. Wang and J. Wei, Journal of Applied Polymer Science, 2008, 107, 391. 2. A. El-Hag Ali, H.A. Abd El-Rehim, E.S.A. Hegazy and M.M. Ghobashy, Radiation Physics and Chemistry, 2006, 75, 1041. 3. L. Yao and S. Krause, Macromolecules, 2003, 36, 2055. 4. S.J. Kim, S.G. Yoon, Y.H. Lee and S.I. Kim, Polymer International, 2004, 53, 1456. 207 Stimuli Responsive Drug Delivery Systems: From Introduction to Application 5. S. J. Kim, M.S. Kim, S.I. Kim, G.M. Spinks, B.C. Kim and G.G. Wallace, Chemistry of Materials, 2006, 18, 5805. 6. S.J. Kim, S.G. Yoon, Y.M. Lee, H.C. Kim and S.I. Kim, Biosensors and Bioelectronics, 2004, 19, 531. 7. Y. Wu, T. Sasaki, S. Irie and K. Sakurai, Polymer, 2008, 49, 2321. 8. S. Phongying, S.I. Aiba and S. Chirachanchai, Polymer, 2007, 48, 393. 9. B. Fei, H. Lu and J.H. Xin, Polymer, 2006, 47, 947. 10. Electronically Controlled Drud Delivery, Eds., B. Berner and S.M. Dinh, CRC Press, Boca Raton, FL, USA, 1998, p.3. 11. A. Kikuchi and T. Okano in Polymeric Drug Delivery Systems: Ed., G.S. Kwon, Taylor & Francis Group, Boca Raton, FL, USA, 2005, p.275. 12. H. Li, Z. Yuan, K.Y. Lam, H.P. Lee, J. Chen, J. Hanes and J. Fu, Biosensors and Bioelectronics, 2004, 19, 1097. 13. M. Homma, Y. Seida and Y. Nakano, Journal of Applied Polymer Science, 2000, 75, 111. 14. J. Ricka and T. Tanaka, Macromolecules, 1984, 17, 2916. 15. W.Y. Gu, W.M. Lai and V.C. Mow, Journal of Biomechanical Engineering, 1998, 120, 169. 16. W.M. Lai, J.S. Hou and V.C. Mow, Journal of Biomechanical Engineering, 1991, 113, 245. 17. A.L. Hodgkin and A.F. Huxley, Journal of Physiology, 1952, 116, 473. 18. L. Onsager, Physical Review, 1931, 37, 405. 19. O. Kedem and A. Katchalsky, Journal of General Physiology, 1961, 45, 143. 20. F. Helfferich, Ion Exchange, McGraw-Hill, New York, NY, USA, 1962. 21. E.H. Frank, A.J. Grodzinsky, S.L. Phillips and P.E. Grimshaw in Biomechanics of Diarthrodial Joints, Volume 1, Eds., V.C. Mow, A. Ratcliffe and S.L-Y. Woo, Springer-Verlag, New York, NY, USA, 1990, p.261. 208 Electric Sensitive Release Systems 22. Extracellular Matrix, Volume 1 - Tissue Function, Ed., W.D. Comper, Harwood Academic Publishers, Amsterdam, The Netherlands, 1996. 23. H. Li, International Journal of Solids and Structures, 2009, 46, 1326. 24. H. Li, J. Chen and K.Y. Lam, Biosensors and Bioelectronics, 2007, 22, 1633. 25. K.Y. Lam, H. Li, T.Y. Ng and R. Luo, Engineering Analysis with Boundary Elements, 2006, 30, 1011. 26. J. Chen, H. Li and K.Y. Lam, Materials Science and Engineering: C, 2005, 25, 710. 27. H. Li, R. Luo and K.Y. Lam, Journal of Membrane Science, 2007, 289, 284. 28. H. Li, R. Luo and K.Y. Lam, Journal of Biomechanics, 2007, 40, 1091. 29. H. Li, T.Y. Ng, Y.K. Yew and K.Y. Lam, Biomacromolecules, 2005, 6, 109. 30. H. Li, T.Y. Ng, J.Q. Cheng and K.Y. Lam, Computational Mechanics, 2003, 33, 30. 31. H. Li, J. Q. Cheng, T.Y. Ng, J. Chen and K.Y. Lam, Engineering Structures, 2004, 26, 531. 32. J.N. Reddy, An Introduction to the Finite Element Method, 2nd Edition, McGraw-Hill, New York, NY, USA, 1993. 33. J. Shang, Z. Shao and X. Chen, Polymer, 2008, 49, 5520. 34. J. Shang, Z. Shao and X. Chen, Biomacromolecules, 2008, 9, 1208. 35. F.A. Aouada, M.R. Guilherme, G.M. Campese, E.M. Girotto, A.F. Rubira and E.C. Muniz, Polymer Testing, 2006, 25, 158. 36. S. Ramanathan and L.H. Block, Journal of Controlled Release, 2001, 70, 109. 37. M. Jensen, P. Birch Hansen, S. Murdan, S. Frokjaer and A.T. Florence, European Journal of Pharmaceutical Sciences, 2002, 15, 139. 38. S.J. Kim, S.J. Park, I.Y. Kim, M.S. Shin and S.I. Kim, Journal of Applied Polymer Science, 2002, 86, 2285. 209 Stimuli Responsive Drug Delivery Systems: From Introduction to Application 39. T. Tanaka, I. Nishio, S.T. Sun and S. Ueno-Nishio, Science, 1982, 218, 467. 40. K. Bajpai, J. Bajpai and S.N. Soni, Express Polymer Letters, 2008, 2, 26. 41. R. Kishi, M. Hara, K. Sawahata and Y. Osada in Polymer Gels: Fundamentals and Biomedical Applications, Eds., D. DeRossi, K. Kajiwara, Y. Osada and A. Yamauchi, Plenum Press, New York, NY, USA, 1991, p.205. 42. D.J. Irvin, S.H. Goods and L.L. Whinnery, Chemistry of Materials, 2001, 13, 1143. 43. G. Filipcsei, J. Feher and M. Zrinyi, Journal of Molecular Structure, 2000, 554, 109. 44. I.C. Kwon, Y.H. Bae, T. Okano, B. Berner and S.W. Kim, Die Macromolekulare Chemie, Macromolecular Symposia, 1990, 33, 265. 45. I.C. Kwon, Y.H. Bae and S.W. Kim, Nature, 1991, 354, 291. 46. I.C. Kwon, Y.H. Bae, T. Okano and S.W. Kim, Journal of Controlled Release, 1991, 17, 149. 47. I.C. Kwon, Y.H. Bae and S.W. Kim, Journal of Controlled Release, 1994, 30, 155. 48. C.S. Hsu and L.H. Block, Pharmaceutical Research, 1996, 13, 1865. 49. K. Kajiwara and S.B. Ross-Murphy, Nature, 1992, 355, 208. 50. Y. Osada, H. Okuzaki and H. Hori, Nature, 1992, 355, 242. 51. K. Salehpoor, M. Shahinpoor and M. Mojarrad in Polymeric-Based Systems Conference, Proceedings of the SPIE, Volume 2716, 1996, p.36, Proceedings of the SPIE – The International Society for Optical Engineering, San Diego, CA, USA, 1996, 36. 52. T. Hirai, J. Zheng, M. Watanabe and H. Shirai in Smart Structures and Materials 2000: Electroactive Polymer Actuators and Devices (EAPAD), Rd., Y. Bar Cohen, proceedings of the SPIE Volume 3987, 2000, p.281, Proceedings of the SPIE – The International Society for Optical Engineering, Convention Center, San Jones, CA, USA, 2000, 3987, 281. 210 Electric Sensitive Release Systems 53. M. Shahinpoor in Smart Structures and Materials 2000: Electroactive Polymer Actuators and Devices (EAPAD), Rd., Y. Bar Cohen, proceedings of the SPIE Volume 3987, 2000, p.187, Proceedings the of SPIE – The International Society for Optical Engineering, Convention Center, San Jones, CA, USA, 2000, 3987, 187. 54. S. Sun and A.F.T. Mak, Journal of Polymer Science, Part B: Polymer Physics Edition, 2001, 39, 236. 55. J. Fei, Z. Zhang and L. Gu, Polymer International, 2002, 51, 502. 56. S.J. Kim, S.U. Ryon Shin, N.G. Kim and S.I. Kim, Journal of Macromolecular Science – Pure and Applied Chemistry, 2005, 42A, 1073. 57. S.J. Kim, S.G. Yoon, Y.M. Lee and S.I. Kim, Sensors and Actuators, B: Chemical, 2003, 88, 286. 58. M. Homma, Y. Seida and Y. Nakano, Journal of Applied Polymer Science, 2001, 82, 76. 59. S.Y. Kim, H.S. Shin, Y.M. Lee and C.N. Jeong, Journal of Applied Polymer Science, 1999, 73, 1675. 211 Stimuli Responsive Drug Delivery Systems: From Introduction to Application 212