* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download balanced three–phase circuits
Solar micro-inverter wikipedia , lookup
Nominal impedance wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Current source wikipedia , lookup
Audio power wikipedia , lookup
Induction motor wikipedia , lookup
Flexible electronics wikipedia , lookup
Power factor wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power inverter wikipedia , lookup
Electrical substation wikipedia , lookup
Buck converter wikipedia , lookup
Electrification wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Zobel network wikipedia , lookup
Electric power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Earthing system wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Power engineering wikipedia , lookup
Mains electricity wikipedia , lookup
JAMES W. NILSSON & SUSAN A. RIEDEL ELECTRIC CIRCUITS EIGHTH EDITION CHAPTER 11 BALANCED THREE–PHASE CIRCUITS © 2008 Pearson Education 3 CONTENTS 11.1 Balanced Three-Phase Voltages 11.2 Three-Phase Voltage Sources 11.3 Analysis of the Wye-Wye Circuit 11.4 Analysis of the Wye-Delta Circuit 11.5 Power Calculations in Balanced ThreePhase Circuits 11.6 Measuring Average Power in ThreePhase Circuits © 2008 Pearson Education Constant rms vtg. must be supplied whether lightly loaded, as at 3:00 am, or heavily loaded, as at midafternoon on a hot, humid day. One technique for maintaining vtg. levels on a utility sys. is to place capacitors at strategic locations in the distribution network. 5 6 11.1 Balanced Three-Phase Voltages A basic three-phase circuit © 2008 Pearson Education 3 vtgs.: A-phase vtg. B-phase vtg. C-phase vtg. 11.1 Balanced Three-Phase Voltages The abc (positive) sequence The abc (negative) sequence Phasor diagrams of a balanced set of three-phase voltages © 2008 Pearson Education 11.2 Three-Phase Voltage Sources A three-phase voltage source is a generator with three separate windings distributed around the periphery of the stator. Rotor: electromagnet driven by steam or gas turbine. Stator is the stationary part of a rotor system and is winded by 3 seperated windings. a three-phase voltage source © 2008 Pearson Education 11.2 Three-Phase Voltage Sources The two basic connections of an ideal three-phase source. A Y-connected source A ∆-connected source © 2008 Pearson Education 11.2 Three-Phase Voltage Sources A model of a three-phase source with winding impedance: (a) A Y-connected source (b) A ∆-connected source © 2008 Pearson Education Basic ckt configuration between S. and load 14 11.3 Analysis of the Wye-Wye Circuit : internal impedance of each phase in generator : line impedance : load impedance © 2008 Pearson Education 16 See: By the way, =0 (balanced 3-phase vtg.) Therefore, Also, Now turn to the effect that balanced conds. have 3 line ct. 11.3 Analysis of the Wye-Wye Circuit A single-phase equivalent circuit A single-phase equivalent circuit is used to calculate the line current and the phase voltage in one phase of the Y-Y structure. The a-phase is normally chosen for this purpose. © 2008 Pearson Education Caution: ct. in neutral conductor is IaA , which is not the same as ct. in neutral conductor, that is, (IaA,or IbB,or IcC), We can find any vtg. easily. 11.3 Analysis of the Wye-Wye Circuit Phasor diagrams showing the relationship between line-to-line and line-to-neutral voltages in a balanced system. The abc sequence The acb sequence © 2008 Pearson Education Above expressions explain the following: Terminology: Line vtg. (VL) refers to vtg. across any pair of lines. Phase vtg. (VΦ) refers to vtg. across a single phase. Line ct. (IL) refers to ct. in a single line. Phase ct.(IΦ) refers to ct. in a single phase. See: Line vtg. = phase vtg. Line ct. = phase ct. Balanced 3 phase Y-connected generator: - impedance of gen.:(0.2 + j0.5)Ω - internal vtg. :120 V/φ Balanced 3 phase Y-connected impedance: (39 + j28)Ω/φ Line impedance: (0.8 + j1.5)Ω a phase vtg. : reference phasor vtg. After the Δ load has been replaced by its Y equivalent, the a-phase can be modeled by the single phase equivalent circuit shown in Fig. 11.11. 30 11.4 Analysis of the Wye-Delta Circuit A circuit used to establish the relationship between line currents and phase currents in a balanced ∆ load © 2008 Pearson Education 11.4 Analysis of the Wye-Delta Circuit Phasor diagrams showing the relationship between line currents and phase currents in a ∆-connected load. The positive sequence The negative sequence © 2008 Pearson Education Y-connected S.: - impedance of gen.:(0.2 + j0.5)Ω - internal vtg. :120 V/φ Δ-connected load impedance: (118.5 + j85.8)Ω/φ cf: Y-connected impedance: (39 + j28)Ω/φ Line impedance: (0.3 + j0.9)Ω a phase vtg. : reference phasor vtg. Y-to-Y ckt See: Line vtg. = phase vtg. Line ct. = phase ct. 11.5 Power Calculations in Balanced Three-Phase Circuits Average Power in a Balanced Wye Load A balanced Y load used to introduce average power calculations in three-phase circuits © 2008 Pearson Education See: - all phasor ct. & vtg. are rms value . - in this sys., 11.5 Power Calculations in Balanced Three-Phase Circuits VL PT 3 I L cos 3 3VL I L cos Total real power in a balanced three-phase load © 2008 Pearson Education 11.5 Power Calculations in Balanced Three-Phase Circuits Complex Power in a Balanced Wye Load Q V I sin QT 3Q 3VL I L sin Total reactive power in a balanced three-phase load © 2008 Pearson Education 11.5 Power Calculations in Balanced Three-Phase Circuits S P jQ V I * ST 3S 3VL I L Total complex power in a balanced three-phase load 11.5 Power Calculations in Balanced Three-Phase Circuits Power Calculations in a Balanced Delta Load Δ-connected load used to discuss power calculations © 2008 Pearson Education Note: in a balanced load, av. power per phase is equal in Y- and Δ-connected. Reactive power & complex power are also same. Note: 48 49 50 Vs = Check! Y-to-Y ckt 11.6 Measuring Average Power in Three-Phase Circuits A wattmeter measures the average power delivered to a load by using a current coil connected in series with the load and a potential coil connected in parallel with the load. : stationary & designed to carry a ct. proportional to the load ct. : movable & carries a ct. proportional to the load vtg. © 2008 Pearson Education 11.6 Measuring Average Power in Three-Phase Circuits The key features of the electrodynamometer wattmeter © 2008 Pearson Education A general circuit whose power is supplied by n conductors © 2008 Pearson Education 11.6 Measuring Average Power in Three-Phase Circuits The total average power in a balanced three-phase circuit can be measured by summing the readings of two wattmeters connected in two different phases of the circuit. © 2008 Pearson Education If we wish to measure the total power at the terminals of the box, we need to know n−1 currents and voltages. Thus the total power is the sum of n − 1 product terms; that is 63 Only two wattmeters are needed to measure the total average power in any balanced three-phase system. 64 65 66 67 Calculate the reading of each wattmeter. Where phase vtg. At the load = 120 V a) b) c) d) Zφ Zφ Zφ Zφ = = = = 8 + j6Ω 8 - j6Ω 5 + j5√3Ω 10∠-75oΩ 68 69 70 71 72 73 Home work Prob. 11.5 11.6 11.11 11.12 11.20 11.21 11.28 11.44 11.46 11.50 11.37 제출기한: - 다음 요일 수업시간 까지 - 제출기일을 지키지않는 레포트는 사정에서 제외함 EE141 74 THE END © 2008 Pearson Education