Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Cardiac Intensive Care Change in regional (somatic) near-infrared spectroscopy is not a useful indictor of clinically detectable low cardiac output in children after surgery for congenital heart defects Utpal S. Bhalala, MD; Akira Nishisaki, MD; Derrick McQueen, MD; Geoffrey L. Bird, MD; Wynne E. Morrison, MD, MBE; Vinay M. Nadkarni, MD; Meena Nathan, MD; Joanne P. Starr, MD Objective: Near-infrared spectroscopy correlation with low cardiac output has not been validated. Our objective was to determine role of splanchnic and/or renal oxygenation monitoring using near-infrared spectroscopy for detection of low cardiac output in children after surgery for congenital heart defects. Design: Prospective observational study. Setting: Pediatric intensive care unit of a tertiary care teaching hospital. Patients: Children admitted to the pediatric intensive care unit after surgery for congenital heart defects. Interventions: None. Measurements and Main Results: We hypothesized that splanchnic and/or renal hypoxemia detected by near-infrared spectroscopy is a marker of low cardiac output after pediatric cardiac surgery. Patients admitted after cardiac surgery to the pediatric intensive care unit over a 10-month period underwent serial splanchnic and renal near-infrared spectroscopy measurements until extubation. Baseline near-infrared spectroscopy values were recorded in the first postoperative hour. A near-infrared spectroscopy event was a priori defined as ≥20% drop in splanchnic and/or renal oxygen saturation from baseline during any hour of the study. Low cardiac output was defined as metabolic acidosis (pH <7.25, lactate >2 mmol/L, or base excess ≤–5), oliguria (urine output <1 A predictable fall in cardiac output (CO), referred to as low cardiac output (LCO) syndrome, occurs after congenital heart surgery and is one of the major causes of perioperative From the Department of Anesthesiology and Critical Care (USB, AN, GLB, WEM, VMN), The Children’s Hospital of Philadelphia, University of Pennsylvania, Philadelphia, PA; Division of Pediatric Critical Care Medicine (DM) and Pediatric Cardiothoracic Surgery (JPS, MN), Children’s Hospital of New Jersey at Newark Beth Israel Medical Center, University of Medicine and Dentistry of New Jersey, Newark, NJ. The authors have not disclosed any potential conflicts of interest. For information regarding this article, E-mail: [email protected] Copyright © 2012 by the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies DOI: 10.1097/PCC.0b013e3182389531 Pediatr Crit Care Med 2012 Vol. 13, No. 5 mL/kg/hr), or escalation of inotropic support. Receiver operating characteristic analysis was performed using near-infrared spectroscopy event as a diagnostic test for low cardiac output. Twenty children were enrolled: median age was 5 months; median Risk Adjustment for Congenital Heart Surgery category was 3 (1–6); median bypass and cross-clamp times were 120 mins (45–300 mins) and 88 mins (17–157 mins), respectively. Thirty-one episodes of low cardiac output and 273 near-infrared spectroscopy events were observed in 17 patients. The sensitivity and specificity of a near-infrared spectroscopy event as an indicator of low cardiac output were 48% (30%–66%) and 67% (64%–70%), respectively. On receiver operating characteristic analysis, neither splanchnic nor renal near-infrared spectroscopy event had a significant area under the curve for prediction of low cardiac output (area under the curve: splanchnic 0.45 [95% confidence interval 0.30–0.60], renal 0.51 [95% confidence interval 0.37–0.65]). Conclusions: Splanchnic and/or renal hypoxemia as detected by near-infrared spectroscopy may not be an accurate indicator of low cardiac output after surgery for congenital heart defects. (Pediatr Crit Care Med 2012; 13:529–534) Key Words: cardiac surgery; cardiopulmonary bypass; congenital heart defect; low cardiac output syndrome; near-infrared spectroscopy; renal; splanchnic morbidity and mortality (1, 2). Studies have shown that a LCO state occurs in as many as 25% of patients (1). Wernovsky et al (3) reported that 25% of neonates with transposition of the great arteries who underwent an arterial switch operation had a drop in cardiac index to <2.0 L/min/m2 between 6 and 18 hrs after surgery. Early detection of LCO may allow pediatric intensive care unit (PICU) practitioners to prevent further deterioration during this critical postoperative period (4). Traditionally, clinicians have relied on clinical findings, such as pulse volume, prolonged capillary refill time, widened core-peripheral temperature difference, hypotension, decreased urine output, and metabolic acidosis on blood gas analysis, as indirect markers of CO and oxygen delivery (5). Current clinical parameters of CO and circulatory function provide partial and sometimes misleading information, especially in children (6). For instance, capillary refill time and core-peripheral temperature difference are often obscured by factors such as fever, use of vasoactive medications, or deliberate mild hypothermia for the management of postoperative junctional ectopic tachycardia (5). Continuous CO measurement is either not available, cumbersome, or invasive and potentially harmful in this population. In current practice, criteria for defining postoperative LCO in children after surgery for congenital heart defects (CHDs) utilize surrogate markers, such as oliguria, metabolic acidosis and change in inotrope support (7, 8). It is known that splanchnic vasoconstriction is an early response to LCO as blood is diverted to the vital organs, such 529 as the heart and brain (9). In animal experiments, it has been demonstrated that increasing degrees of cardiogenic shock induced by cardiac tamponade raise inferior mesenteric resistance up to four times more than total vascular resistance (10). In healthy adult human volunteers, a 15% reduction in circulating blood volume resulted in a 40% reduction in splanchnic blood volume while heart rate, blood pressure, and CO remained unchanged (11). Near-infrared spectroscopy (NIRS) is a technique that has been used in various clinical settings to evaluate regional tissue oxygenation in a noninvasive manner (12–19). NIRS renal and splanchnic regional oxygenation monitoring has been shown to positively correlate with mixed venous saturation (17, 18) and lactate levels (19) in children after surgery for CHD. Evidence is still lacking to support its use in the postoperative period to detect early LCO in children. We therefore designed this study to assess the ability of NIRS splanchnic and/ or renal oxygenation monitoring to detect clinically detectable LCO in children after surgery for CHD. MATERIALS AND METHODS The study is a prospective observational study of children admitted to a PICU who had surgery for congenital cardiac defects during a 10-month period between November 2007 and August 2008. The local institutional review board approved the study, and written informed consent was obtained from a legal guardian of each subject. Subjects The study included children between 0 and 21 yrs of age who underwent surgery for CHD requiring cardiopulmonary bypass (CPB) and were subsequently admitted to the PICU. Patients with clinical and/or radiologic evidence of necrotizing enterocolitis were excluded from the study. Patients were categorized for disease severity using the Risk Adjustment for Congenital Heart Surgery categories (20). All operations were performed by two surgeons during the study period. Standard clinical practice at the institution included intraoperative deep hypothermia to a temperature between 18°C and 25°C, when indicated, and a CPB circuit (Stockert-Shiley pumps, Osterwaldstrasse, Munchen, West Germany) with a membrane oxygenator and roller pump. The CPB technique was similar for all age groups, and modified ultrafiltration was used in all cases. Flow rates varied with age from 100 to 175 mL/kg/min for 530 children weighing <10 kg and 2 to 3 L/min for >10 kg. The pump was primed with heparin (2 U/mL of prime solution), sodium bicarbonate (15–20 mEq), 25% albumin (50 mL), furosemide (1 mg/kg, maximum of 20 mg), methylprednisolone (30 mg/kg, maximum 500 mg), cefazolin (30 mg/kg), one unit of packed red cells, 150 mg of calcium chloride for children weighing <10 kg, and PlasmaLyte A (Baxter, Deerfield, IL). Total CPB and cross-clamp times were recorded for all patients. Patients were transferred to the PICU after surgery. They were placed on fentanyl infusions with or without muscle relaxant. Postoperative inotrope management in the PICU was at the discretion of the PICU physicians. The inotropic agents used were either dopamine alone or in combination with epinephrine or milrinone. The inotrope score (3) was determined in each patient at the time of arrival to the PICU and subsequently at the time of escalation of the inotropic support. In all the patients, point-of-care arterial blood gases and lactate levels were measured using iSTAT, a portable clinical analyzer device (I-stat, East Windsor, NJ), every hour and as needed in the postoperative period until extubation. Also, urine output was recorded every hour until extubation. Outcome This study’s primary outcome was the occurrence of LCO. Previous studies in children after cardiac surgery have used surrogate markers like oliguria, tachycardia, cool extremities, arterio-venous oxygen difference, occurrence of metabolic acidosis, initiation of a new inotropic agent, escalation of existing pharmacologic support, and initiation of extracorporeal membrane oxygenation to define LCO syndrome (7, 8). Similar to these pediatric studies, we defined LCO as one or more of the following surrogate markers: need for fluid bolus, occurrence of metabolic acidosis (pH <7.25, lactate >2 mmol/L, base excess ≤–5), oliguria (urine output <1 mL/kg/hr), and/or escalation in inotropic support. Measurement of Somatic Regional Oxygen Saturation Using NIRS Somatic regional oxygen saturation (rSo2) was monitored until extubation using a multichannel NIRS device (Somanetics, Troy, MI). Regional oxygen saturation at splanchnic and renal regions were measured by applying age- and weight-appropriate NIRS probes over the anterior abdominal wall above the umbilicus and over the flank at the renal angle, respectively. The NIRS device measured splanchnic and renal oxygen saturations every 6 to 30 secs. Probes, cables, and monitors were placed and maintained by study personnel and nursing staff. The bedside medical team was not responsible for NIRS setup and maintenance, and clinical management was not altered based on the display. The NIRS values recorded in the first postoperative hour were used to define each subject’s baseline. Statistical Analysis All data were analyzed in hourly epochs during the postoperative phase until extubation. A NIRS event (NE) was a priori defined as a relative drop in splanchnic and/or renal oxygen saturation (SrSo2 and RrSo2, respectively) by ≥20% from baseline value as in a prior study (21). For example, when a patient with baseline renal NIRS at 80% dropped renal NIRS down to 64%, this event is calculated as a 20% drop from the baseline. Sensitivity and specificity of NE as a diagnostic test of LCO was performed using 2 × 2 table. Receiver operating curve (ROC) analysis was then performed to determine whether any other percent drop from baseline in NIRS values was a better predictor of LCO. Sensitivity analyses were performed using a limited LCO definition without fluid bolus as well as for subjects below 5 months of age. Summary data are described as range, interquartile range, or 95% confidence interval (CI). All analyses were performed with Stata version 11 (Stata, College Station, TX). RESULTS We enrolled 20 patients for the study, and three were excluded due to technical challenges in obtaining complete NIRS data. The remaining 17 patients provided 828 hrs of postoperative measurements. Demographics and surgical background data are summarized in Table 1. There were six univentricular lesions – one with pulmonary atresia status post Blalock-Taussig shunt, two with tricuspid atresia and pulmonary atresia status post Blalock-Taussig shunt, two with hypoplastic left heart syndrome, and one with double outlet right ventricle. There were 11 biventricular lesions – one with secundum atrial septal defect, one with transposition of great arteries with intact ventricular septum, six with tetralogy of Fallot, two with large perimembranous ventricular septal defect, and one with common atrioventricular canal defect. Six patients underwent intraoperative transesophageal echocardiograms, all of which demonstrated good ventricular function. Baseline postoperative data are summarized in Table 2. Using a cutoff of ≥20% drop in SrSo2 and/or RrSo2 from baseline during any study hour for NE, Pediatr Crit Care Med 2012 Vol. 13, No. 5 Table 1. Demographic and surgical data of the patients Parameter Median Range (Interquartile Range) Age (months) Gender Weight (kg) Height (cm) Risk Adjustment for Congenital Heart Surgery-1 Cardiopulmonary bypass time (min) Cross-clamp time (min) Type of lesion 5 Not applicable 5 55 3 120 88 Not applicable 0.06–180 (1.2–8.0) Male 14, Female 3 2–63 (3.6–6.3) 43–150 (51–66.5) 1–6 (2–3) 45–300 (92.5–225) 17–157 (54–108) Univentricular 6 Biventricular 11 Table 2. Baseline postoperative data of the patients Parameter Median Range (Interquartile Range) Temperature (°F) Heart rate (per minute) Systolic blood pressure (mm Hg) Diastolic blood pressure (mm Hg) Inotrope score pH Base deficit (mEq/L) Lactate (mmol/L) Splanchnic regional oxygen saturation Renal regional oxygen saturation 98.5 160 96 54 10 7.36 0 3.20 65 65 94.1–100.9 (96–98.3) 108–209 (151–176) 68–132 (89–104) 33–67 (47–62) 0–17.5 (9.6–13.1) 7.28–7.42 (7.31–7.38) –5 to +3 (–1.75–1.75) 1.62–9.33 (2.2–3.6) 30–90 (51.5–84) 27–90 (62–87.5) 273 NEs and 31 episodes of LCO were observed in 17 patients. Figure 1 shows an example of NE and LCO episodes during a 24-hr record of SrSo2 and RrSo2 in one of the patients. Of 31 LCO episodes observed, 17 were in the form of fluid boluses, two were oliguria, five were the occurrence of metabolic acidosis, and seven were an escalation of inotropic support. Among seven LCO events that were identified as escalation of inotrope support, two were in the form of escalation of epinephrine infusion (change in inotrope score from 14.5 to 15.5 and 13 to 14, respectively), two as escalation of dopamine infusion (change in inotrope score from 11 to 13 and 5 to 7, respectively), one as escalation of milrinone infusion (change in inotrope score from 5 to 7.5), and two as restarting of the dopamine infusion (change in inotrope score from 0 to 5 in each). NEs were observed with 48% (15 of 31) of LCO events. The sensitivity and specificity for LCO were 48.3% (95% CI: 30.5%–66.6%) and 67.6% (95% CI: 64.2%–70%), respectively. Table 3 presents sensitivity, specificity, positive predictive value, and negative predictive value of NE as a diagnostic test for LCO using NE cutoff as ≥5%, 10%, 15%, 20%, 30%, and 40% drop from the baseline. ROC analysis revealed that neither splanchnic nor renal NE had a significant area under the curve Pediatr Crit Care Med 2012 Vol. 13, No. 5 (AUC) for prediction of LCO (splanchnic: AUC 0.45, 95% CI 0.30–0.60; renal: AUC 0.51, 95% CI 0.37–0.65). The diagnostic ability of NIRS (with ≥20% drop from baseline as cutoff value) did not change when we used a limited LCO definition after eliminating fluid bolus as a criterion for LCO (sensitivity, 42.8% [95% CI 18–70], specificity, 67.1% [95% CI 63–70]), and also when we performed analysis of data for subjects below 5 months of age only (n = 8) (AUC for splanchnic NE = 0.51 [95% CI 0.33–0.69], AUC for renal NE = 0.48 [95% CI 0.31–0.65]). When we used ≥20% drop in NIRS saturation as a cutoff for detection of LCO, only 5.4% (95% CI 3.2–9.0) of NEs had an association with clinical LCO, whereas 97.1% (95% CI 95.2–98.2) of NEs were not associated with clinical LCO events. There was one patient out of the 17 patients with a high baseline lactate level of 9.33 mmol/L and low renal and splanchnic baseline NIRS values of 27 and 30, respectively. This patient belonged to Risk Adjustment for Congenital Heart Surgery category 2, with a CPB time of 120 mins and baseline inotrope score of 10. There was no intraoperative transesophageal echocardiogram record available for this patient, however. The remaining 16 patients had baseline lactate level <3 mmol/L. A sensitivity analysis with and without this patient did not change the direction or significance of our findings. The diagnostic characteristics did not improve when we used an absolute NIRS measurement cutoff instead of a relative percent drop from baseline values (AUC for splanchnic NIRS: 0.58 [95% CI 0.43–0.73], AUC for renal NIRS: 0.50 [95% CI 0.37–0.63]). DISCUSSION To our knowledge, this is one of the few studies that examined the sensitivity and specificity of NIRS splanchnic and/ or renal tissue oxygenation monitoring for detection of LCO in children following surgery for both single- and two-ventricle reconstruction of CHDs. Since splanchnic and/or renal tissue hypoxemia can be an early indicator of LCO, NIRS regional oxygen monitoring has been proposed as an early marker of LCO. Our data, however, show that NIRS monitoring for renal and splanchnic oxygenation has poor predictive validity as an indicator of LCO. This result is surprising because previous studies demonstrated a better correlation between somatic NIRS and indirect measures of CO, such as mixed venous saturation (17, 18) and lactate levels (19). Explanations for our differing results from other studies include the possibility that somatic rSo2 measurements using current sensors are not accurate. Greisen (22) recently described a lack of accuracy of the currently available NIRS instruments in measurement of cerebral rSo2. Commercial NIRS sensors have a signal-to-noise ratio of 2%–3%, higher than that of pulse oximetry. According to Greisen (22), averaging the absolute cerebral NIRS tissue oxygenation index measurements over a minute can provide an accurate mean value and overcome the problem of large signal-tonoise ratio. Mean values differ, however, based on site of sensor placement, as much as 15%. This expert review concluded that the precision of currently available NIRS instruments is insufficient for clinical use (22). There are also concerns that abdominal wall thickness may exceed the sampling depth (1.5–2 cm) of currently used NIRS probes in patients above 4 yrs for renal and 6 yrs for splanchnic measurements (23). We therefore performed an analysis of data for subjects younger than 5 months of age (n = 8) with no improvement in sensitivity and specificity. It is also possible that the previously used threshold of a 20% drop in NIRS values is not an appropriate cutoff for 531 Figure 1. Twenty-four–hour record of splanchnic and renal regional oxygen saturation (rSo2) with near-infrared spectroscopy (NIRS) event: NIRS event (arrow) and low cardiac output (LCO) episodes (heart). At time 00:32:58, NIRS event precedes a LCO episode whereas at times 09:17:10 and 12:01:02, both NIRS events did not precede any LCO episodes. Table 3. Positive predictive value, negative predictive value, sensitivity, and specificity of near-infrared spectroscopy for low cardiac output at various cutoffs Near-infrared Spectroscopy Cutoff Drop From Baselinea ≥5% ≥10% ≥15% ≥20% ≥30% ≥40% Positive Predictive Value (95% CI) 3.5 (2.1–5.6) 3.5 (2.1–5.7) 4.3 (2.5–7.1) 5.4 (3.2–9.0) 5.2 (2.9–8.9) 2.8 (1.0–6.9) Negative Predictive Value (95% CI) 95.9 (93.0–97.7) 95.9 (93.2–979.7) 96.6 (94.5–98.0) 97.1 (95.2–98.2) 96.8 (95.0–98.0) 96.8 (94.1–98.3) Sensitivity (95% CI) Specificity (95% CI) 58 (39.2–74.9) 54.8 (36.2–72.2) 48.3 (30.5–66.6) 48.3 (30.5–66.6) 41.9 (25–60.7) 16.1 (6–34.4) 38.6 (35.2–42.1) 42 (38.5–45.5) 58.2 (54.6–61.6) 67.6 (64.2–70) 70.2 (66.9–73.3) 78.9 (75.8–81.6) CI, confidence interval. a Drop from baseline is calculated as relative proportion of drops from the admission baseline value. For example, if a patient has a near-infrared spectroscopy value of 80% at admission, then a nearinfrared spectroscopy drop down to 64% is considered as 20% drop. LCO. Currently, data on the normal range of NIRS rSo2 exist only in healthy term newborns (24). Similar to several studies (25–28), we observed substantial between-subject variability in baseline NIRS rSo2 values (baseline SrSo2 values ranged from 30 to 90 and baseline RrSo2 values ranged from 27 to 90). We performed the ROC analysis to evaluate the discriminative ability of the NIRS measurement and to identify an appropriate cutoff for the postoperative NIRS measurement. We were not able to identify any appropriate cutoff for LCO, however. To address the issue of baseline variability in NIRS rSo2 values, we also ran a ROC analysis for the 532 absolute rSo2 values instead of the relative percent drop from baseline as a sensitivity analysis. This strategy also did not improve the diagnostic characteristics of the NIRS-derived splanchnic and/or renal regional oxygenation for LCO. One other possibility is that our surrogate markers inadequately represent LCO. As is usually the case in clinical practice in pediatrics, we did not have a continuous CO measurement to correlate with somatic NIRS values. We defined LCO using clinical (oliguria, need of fluid bolus, or escalation of inotrope support) and/or laboratory (occurrence of metabolic acidosis) criteria as have previously published studies (7, 8). Because clinicians’ decisions to provide a fluid bolus could conceivably be affected by factors other than a diagnosis of LCO, we conducted a sensitivity analysis with a more limited definition of LCO excluding fluid boluses. This yielded similar results. In recent years there has been increased interest in NIRS as a monitoring device in various clinical settings (15–17, 29-32), but there are gaps in the understanding of NIRS regional oxygenation monitoring. One study provided normal NIRS values of cerebral and renal rSo2 in a small population of healthy term newborns (24), but baseline preoperative rSo2 in children with cyanotic and noncyanotic heart defects are not known. Also, the effects of palliative or corrective surgery for these lesions on the rSo2 are unknown. Hoffman et al (17) evaluated the correlation between regional (cerebral and renal) NIRS measures and mixed venous saturations in neonates after stage 1 palliation for single-ventricle lesions. The intrapatient correlation among rSo2 and mixed venous saturation was higher (r2 = .53) than interpatient correlation (r2 = .46). Therefore, the authors concluded that the NIRS measure is a reliable noninvasive indicator of mixed venous saturations. Another study by Chakravarti et al (19) showed a correlation between NIRS measurements and lactate levels among children with Pediatr Crit Care Med 2012 Vol. 13, No. 5 double-ventricle physiology undergoing repair of CHD. In this study, they evaluated the diagnostic values of cerebral, splanchnic, renal, and muscle rSo2 using blood lactate as a surrogate standard for LCOs. Measured rSo2 at each point was averaged over 1 hr before a blood draw. They measured lactate levels at 0, 2, 4, 6, 8, 10, 12, 14, and 24 hrs after surgery. By using this methodological approach, they probably missed an unknown number of changes in NIRS rSo2 values and lactate levels. Our study monitored blood lactate every hour with other clinical signs of LCO, and the NE was defined as a drop in rSo2 below baseline every hour. We believe our approach is more realistic and close to the clinical application. In a case series of children who underwent cardiac surgery, the authors stated that NIRS may herald deterioration and that there may be a “threshold” effect that NIRS may usefully detect (33). Our study, using ROC analysis, failed to detect any meaningful threshold value of either renal or splanchnic NIRS measurement to detect early deterioration (LCO). It appears that NIRS events are overwhelmingly associated with no change in clinical CO status, demonstrated by an extremely low positive predictive value. Therefore, our study results cannot support the routine use of regional NIRS as an indicator that reliably heralds LCO. Our study has several limitations. This is a prospective observational study with a small sample size from a single PICU, and the majority of patients belonged to low Risk Adjustment for Congenital Heart Surgery categories. Since the definition of LCO may be problematic, future multicentered studies would benefit from continuous CO or mixed venous saturation measurement to compare to rSo2. We cannot exclude the possibility that they may have responded to the values on the display with interventions to potentially improve CO, although clinicians caring for our study subjects were not formally trained to interpret data from the NIRS monitor. If this occurred, however, it would have increased the likelihood that a fall in NIRS values would be associated with clinician interventions, biasing toward a positive result, which we did not find. Therefore, this is unlikely the case. We also used a landmark approach to place NIRS probes to detect splanchnic and renal rSo2. This might have decreased the validity of the NIRS measures in older patients, although those were few in our Pediatr Crit Care Med 2012 Vol. 13, No. 5 study population. Also, if it were possible to continuously monitor lactate, base deficit, and instantaneous glomerular filtration rate, then there may have been other transient episodes of LCO that the clinical criteria missed. We acknowledge this is a methodological challenge when we compare an intermittent diagnostic test with continuously measured parameters. Some physicians have recommended NIRS as “standard of care” in children for postoperative management (34), recognizing that “regional saturation measured by the NIRS technology may provide an early indication of oxygen deficits associated with impending shock states and anaerobiosis” (35). Our study results, however, suggested that NIRS measurements of splanchnic and renal regional oxygenation have limited capability to detect LCO. Further study is needed to delineate where the NIRS technology plays an important role to manage critically ill infants and children. CONCLUSIONS Splanchnic and/or renal tissue hypoxemia as detected by NIRS may not be highly sensitive or specific for clinical LCO after open-heart surgery in children. ACKNOWLEDGMENTS We thank the PICU staff at Children’s Hospital of New Jersey for their assistance with NIRS monitoring. We also extend our special thanks to children and their parents for their willingness to contribute to the science. REFERENCES 1. Parr GV, Blackstone EH, Kirklin JW: Cardiac performance and mortality early after intracardiac surgery in infants and young children. Circulation 1975; 51:867–874 2. Shi S, Zhao Z, Liu X, et al: Perioperative risk factors for prolonged mechanical ventilation following cardiac surgery in neonates and young infants. Chest 2008; 134:768–774 3.Wernovsky G, Wypij D, Jonas RA, et al: Postoperative course and hemodynamic profile after the arterial switch operation in neonates and infants. A comparison of low-flow cardiopulmonary bypass and circulatory arrest. Circulation 1995; 92:2226–2235 4. Wessel DL: Managing low cardiac output syndrome after congenital heart surgery. Crit Care Med 2001; 29:S220–S230 5.Ravishankar C, Tabbutt S, Wernovsky G: Critical care in cardiovascular medicine. Curr Opin Pediatr 2003; 15:443–453 6.Hoffman GM, Ghanayem NS, Tweddell JS: Noninvasive assessment of cardiac output. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2005:12–21 7.Hoffman TM, Wernovsky G, Atz AM, et al: Prophylactic intravenous use of milrinone after cardiac operation in pediatrics (PRIMACORP) study. Prophylactic Intravenous Use of Milrinone After Cardiac Operation in Pediatrics. Am Heart J 2002; 143:15–21 8.Hoffman TM, Wernovsky G, Atz AM et al: Efficacy and safety of milrinone in preventing low cardiac output syndrome in infants and children after corrective surgery for congenital heart disease. Circulation 2003; 107:996–1002 9.Dantzker DR: The gastrointestinal tract. The canary of the body? JAMA 1993; 270:1247–1248 10.Bailey RW, Bulkley GB, Hamilton SR, et al: Pathogenesis of nonocclusive ischemic colitis. Ann Surg 1986; 203:590–599 11.Price HL, Deutsch S, Marshall BE, et al: Hemodynamic and metabolic effects of hemorrhage in man, with particular reference to the splanchnic circulation. Circ Res 1966; 18:469–474 12.Brazy JE, Lewis DV, Mitnick MH, et al: Noninvasive monitoring of cerebral oxygenation in preterm infants: Preliminary observations. Pediatrics 1985; 75:217–225 13.Wyatt JS, Cope M, Delpy DT, et al: Quantification of cerebral oxygenation and haemodynamics in sick newborn infants by near infrared spectrophotometry. Lancet 1986; 2:1063–1066 14.Cairns CB, Moore FA, Haenel JB, et al: Evidence for early supply independent mitochondrial dysfunction in patients developing multiple organ failure after trauma. J Trauma 1997; 42:532–536 15.McKinley BA, Marvin RG, Cocanour CS, et al: Tissue hemoglobin O2 saturation during resuscitation of traumatic shock monitored using near infrared spectrometry. J Trauma 2002; 48:637–642 16.Ikossi DG, Knudson MM, Morabito DJ, et al: Continuous muscle tissue oxygenation in critically injured patients: A prospective observational study. J Trauma 2006; 61:780–790 17.Hoffman GM, Stuth EA, Berens RJ, et al: Two-site near-infrared transcutaneous oximetry as a non-invasive indicator of mixed venous oxygen saturation in cardiac neonates. Anesthesiology 2003; 99:A1393 18.Kaufman J, Almodovar MC, Zuk J, et al: Correlation of abdominal site near-infrared spectroscopy with gastric tonometry in infants following surgery for congenital heart disease. Pediatr Crit Care Med 2008; 9:62–68 19. Chakravarti SB, Mittnacht AJ, Katz JC, et al: Multisite near-infrared spectroscopy predicts elevated blood lactate level in children after cardiac surgery. J Cardiothorac Vasc Anesth 2009; 23:663–667 20.Jenkins KJ, Gauvreau K: Center-specific differences in mortality: Preliminary analyses using the Risk Adjustment in Congenital 533 Heart Surgery (RACHS-1) method. J Thorac Cardiovasc Surg 2002; 124:97–104 21.Giacomuzzi C, Heller E, Mejak B, et al: Assessing the brain using near-infrared spectroscopy during postoperative ventricular circulatory support. Cardiol Young 2005; 15:154–158 22.Greisen G: Is near-infrared spectroscopy living up to its promises? Semin Fetal Neonatal Med 2006; 11:498–502 23.Balaguru D, Bhalala U, Haghighi M, et al: Computed tomography scan measurement of abdominal wall thickness for application of near-infrared spectroscopy probes to monitor regional oxygen saturation index of gastrointestinal and renal circulations in children. Pediatr Crit Care Med 2011; 12:e145–e148 24.Bernal NP, Hoffman GM, Ghanayem NS, et al: Cerebral and somatic near-infrared spectroscopy in normal newborns. J Pediatr Surg 2010; 45:1306–1310 25.Hofer A, Haizinger B, Geiselseder G, et al: Monitoring of selective antegrade cerebral perfusion using near infrared spectroscopy in neonatal aortic arch surgery. Eur J Anaesthesiol 2005; 22:293–298 534 26.Tortoriello TA, Stayer SA, Mott AR, et al: A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. Paediatr Anaesth 2005; 15:495–503 27. Schulz G, Weiss M, Bauersfeld U, et al: Liver tissue oxygenation as measured by near-infrared spectroscopy in the critically ill child in correlation with central venous oxygen saturation. Intensive Care Med 2002; 28:184–189 28. Li J, Van Arsdell GS, Zhang G, et al: Assessment of the relationship between cerebral and splanchnic oxygen saturations measured by near-infrared spectroscopy and direct measurements of systemic haemodynamic variables and oxygen transport after the Norwood procedure. Heart 2006; 92:1678–1685 29. van Bel F, Lemmers P, Naulaers G: Monitoring neonatal regional cerebral oxygen saturation in clinical practice: Value and pitfalls. Neonatology 2008; 94:237–244 30.Chakravarti S, Srivastava S, Mittnacht AJ: Near infrared spectroscopy (NIRS) in children. Semin Cardiothorac Vasc Anesth 2008; 12:70–79 31.Nollert G, Jonas RA, Reichart B: Optimizing cerebral oxygenation during cardiac surgery: A review of experimental and clinical investigations with near infrared spectrophotometry. Thorac Cardiovasc Surg 2000; 48:247–253 32. Hirsch JC, Charpie JR, Ohye RG, et al: Nearinfrared spectroscopy: What we know and what we need to know–a systematic review of the congenital heart disease literature. J Thorac Cardiovasc Surg 2009; 137:154–159, 159e1–159e12 33.Kane JM, Steinhorn DM: Lack of irrefut able validation does not negate clinical utility of near infrared spectroscopy monitoring: Learning to trust new technology. J Crit Care 2009; 24:472.e1–e7 34.Tweddell JS, Ghanayem NS, Hoffman GM: Pro: NIRS is “standard of care” for postoperative management. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2010; 13:44–50 35. Somanetics: News release: Somanetics announces new FDA 510(K) Clearance – Labeling expanded to include improved patient outcomes and real-time measurement accuracy. Available at: http://www.somanetics. com. Accessed September 1, 2010 Pediatr Crit Care Med 2012 Vol. 13, No. 5