* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download HINCP Series Basic Control Contactor Panel Interiors Installation
Three-phase electric power wikipedia , lookup
Power over Ethernet wikipedia , lookup
Variable-frequency drive wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrification wikipedia , lookup
Electrical substation wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Electric power system wikipedia , lookup
Distributed control system wikipedia , lookup
Control theory wikipedia , lookup
Mains electricity wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Resilient control systems wikipedia , lookup
Power engineering wikipedia , lookup
Alternating current wikipedia , lookup
Crossbar switch wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Light switch wikipedia , lookup
Control system wikipedia , lookup
Electrical wiring wikipedia , lookup
Model Numbers HINCPxx16y-115 HINCPxx32y-115 HINCPxx64y-115 HINCPxx16y-277 HINCPxx32y-277 HINCPxx64y-277 xx = # of pre-installed poles (4 per contactor – 16, 32 or 64 maximum y = C – SC100-CP Clock installed – for single or main panel, or N – No Clock – for expansion panels 115 or 277 = panel voltage Introduction The HINCP is the Interior for a Basic Control Contactor Panel. The interior includes a customer-specified number of 4-pole contactors, pre-wired to channels on a control board. The board includes the panel’s transformer with power connections, as well as connections for input devices and expansion terminals for connection with other Basic Contactor panels. A metal barrier separates the line-voltage and lowvoltage sides of the panel. A complete panel assembly includes one each of the following: 1. HINCP series interior 2. HTUBxx tub enclosure 3. HCVRxxSL (surface mount, lockable) cover or HCVRxxFL (flush mount, lockable) cover Features • 4-pole, normally closed contactors, pre-installed and tested in user-selected quantity • 8 control channels, pre-wired to contactors • On/Off/Auto manual switches for each channel • Status LED for each channel • 115 VAC or 277 VAC power supply • Optional 8-channel timeclock, pre-installed in master panel • 8 programmable inputs for channel override devices such as switches, sensors or photocells • Auxiliary power connections for override devices • Expansion terminals to additional panels Separating these components simplifies installation. The tub may be mounted for early rough-in wiring, and then the interior simply slides into the tub at the appropriate time. CONTENTS: Mounting ......................................................................2 Line-voltage Wiring ...................................................2-4 Panel Power .............................................................2 Contactors to Loads .................................................3 Contactors to Control Channels ...............................3 Contactors to AS-110 Switches ...............................4 Low-voltage Wiring....................................................4-6 SC-100-CP Clock .....................................................4 On/Off/Auto Switches ...............................................4 Expansion Terminals ................................................5 Override Inputs ........................................................5 Auxiliary Power ........................................................6 Test ..............................................................................6 Program the System ........see SC100-CP System Clock Operator’s Manual Santa Clara, CA 95050 © 2001 The Watt Stopper,® Inc. Installation Instructions HINCP Series Basic Control Contactor Panel Interiors Installation and Setup HINCP Series Basic Control Contactor Panel Interiors — Installation and Setup Mounting Before installing the interior, mount the appropriate-sized tub (refer to the table below) to the wall as detailed in document INHTUB Lighting Control Panel Tub Installation and Setup. The tub should be level, plumb and rigidly installed with hardware sufficient to hold 100 lbs. (48 kg) The cover may also be attached to the tub at this time, or set it aside until all wiring is complete. See document INHCVR Lighting Control Panel Cover Installation. Figure 1 – Low-voltage and Line-voltage Sections Class 2 low-voltage wiring High-voltage line and load wiring Class 2 High-Voltage Low-Voltage Wiring Section Wiring Section Tub Enclosure Interior Stud-mounted 1 1 2 3 4 INTERIOR CATALOG # TUB CATALOG # COVER CATALOG # HINCPxx16y-115 HTUB12 HCVR12SL/FL HINCPxx32y-115 HTUB24 HCVR24SL/FL HINCPxx64y-115 HTUB48 HCVR48SL/FL HINCPxx16y-277 HTUB12 HCVR12SL/FL HINCPxx32y-277 HTUB24 HCVR24SL/FL HINCPxx64y-277 HTUB48 HCVR48SL/FL 2 1 2 3 4 Conduit Entrance Top, Bottom, Sides Typical Class 2 low-voltage wiring Observe the proper side for line-voltage and low-voltage wiring as shown in Figure 1. Route line-voltage wiring through the right half (top, bottom or right side) of the tub. Route Class 2 lowvoltage wiring from remote switches or other controls through the left half (top, bottom or left side) of the tub. Do not make conduit connections that extend into the tub until the interior has been set in place. Slide the interior into the tub and secure to the studs with the hardware provided. Make sure that all wiring is confined to the appropriate line- or low-voltage sides. PANEL INPUT RATINGS CURRENT RATINGS CATALOG NUMBER MAXIMUM NOMINAL INPUT ±10% 50/60 HZ (HOLDING) HINCPxx16y-115 115 VAC 2.3 A 1.0 A HINCPxx32y-115 115 VAC 4.2 A 1.5 A HINCPxx64y-115 115 VAC 8.0 A 2.0 A HINCPxx16y-277 277 VAC 1.0 A 1.0 A HINCPxx32y-277 277 VAC 1.8 A 1.0 A HINCPxx64y-277 277 VAC 3.5 A 1.0 A 2 High-voltage line and load wiring Line-voltage Wiring Figure 2 – Power Terminals CAUTION: Make sure all power is OFF before wiring. Do not energize wiring until unit is fully assembled. Conform to all applicable codes. High-voltage Section Panel Power The panel is shipped with an integral transformer, either 115 VAC or 277 VAC. The transformer provided can be determined by the catalog number of the HINCP interior, which ends in either -115 or -277. A red warning label identifying the correct voltage is also applied over the power terminals. Refer to the table to the left for current ratings for each panel. WARNING: Observe correct voltage. Applying incorrect voltage to the panel will void the panel warranty. Remove the red warning label, and wire power for the panel from a dedicated circuit (recommended) to the “Control Power” terminals (marked AC and Neu) as shown in Figure 2. (Note: Torque the terminals to 9 in/lbs) Connect the ground wire to the ground lug provided on the interior’s backplane. Control Power A TB3 AC Neu B C D E F H Ground Hot (115V or 277V) Neutral HINCP Series Basic Control Contactor Panel Interiors — Installation and Setup Figure 3 – Contactor-to-load Wiring Neutral CONTACT Hot 1 Hot Load 1 2 Load 2 3 Single-Phase Loads 120/277V 4 CONTACT Hot-Phase X 1 Hot-Phase Y Contactors to Loads Hot-Phase Y 3 Hot-Phase Z Contact Load rating: • General Purpose 30A @ 600V • Lighting Ballast 30A @ 600V • Tungsten Load 20A @ 277V CONTACT 4 Load 2 Contactors to Control Channels Each of the panel’s 8 control channels (A-H) is pre-wired to the numbered contactors as shown in the table below. HINCPxx32 A 01 01 01 09 B 02 02 02 10 C 03 03 03 11 D 04 HINCPxx64 HINCPxx16 LOCATION PART # PANEL TYPE CONTROL CIRCUIT# MOUNTING CONTACT or POLES 1-1 1-2 1-3 1-4 2-1 2-2 2-3 2-4 3-1 CIRCUIT # CHANNEL MAIN EXPANSION SURFACE FLUSH DESCRIPTION / NOTES For access to channel-contactor wiring, remove the wire duct cover located between the contactors and the control board. Each wire is labeled with its associated contactor number. Reroute the wires to the desired channel as needed by one of two methods: LIGHTING CONTROL PANEL SCHEDULE - BASIC CONTROL NAME Load 3 Operation: Basic Control Contactor Panels use normally closed contactors. When contactor poles are closed, loads are energized or turned ON. When contactor poles are opened, loads are de-energized or turned OFF. CHANNEL Record wiring on the Lighting Control Panel Schedule and store this form in the plastic sleeve inside the panel cover. Three-Phase Loads 208/480V 3 Terminals accept #14 to #10 gauge wire. NOTE: When the contactor is de-energized, contacts are closed. Load 1 2 Hot-Phase Z Route circuits through the contactors to the appropriate loads as shown to the right in Figure 3. Two-Phase Loads 208/240/480V 1 Hot-Phase Y Contactors are normally closed to ensure that lighting will continue to work in the event of contol power or system failure. The SC100-CP system clock is used to program each channel to operate as required. Load 2 4 Hot-Phase X Wire size: Load 1 2 04 04 12 E 05 05 13 F 06 06 14 G 07 07 15 H 08 08 16 1 On the control power terminal strip, move wires under the appropriate channel’s terminal screw, or 2 On the contactor side, remove unneeded control wires (cap off) and jumper contactor control power from one contactor to the next. Replace the wire duct cover. Record wiring information on the Lighting Channel Schedule and store in the plastic sleeve in the panel cover. 3-2 3-3 3-4 4-1 4-2 4-3 4-4 If necessary, control wires from channels to contactors may be rewired in the field to suit the application. 5-1 5-2 5-3 5-4 6-1 6-2 6-3 6-4 LIGHTING CHANNEL SCHEDULE - BASIC CONTROL CHANNEL CHANNEL DESCRIPTION CONTROL STRATEGY A B C CAUTION: Disconnect all power to the panel before re-wiring contactors. There may be power from more than one source. Make sure all circuits to the contactors are de-energized. D E F G H 3 HINCP Series Basic Control Contactor Panel Interiors — Installation and Setup Contactors to AS-110 Switches The AS-110 Automatic Control Switch is a line-voltage switch that adds control capability to the HINCP Contactor panel. The AS-110 can be manually operated to turn loads on and off. In addition, the Basic Control Contactor Panel signals the switches to turn on, turn off or delay off (programmed through the SC100-CP clock). Wire AS-110 switches as shown in Figure 4. Figure 4 – AS-110 Switch Wiring Neutral Hot CONTACTOR 1 2 3 4 Hot Neutral Cap-off Multi-way Load Load 1 CAUTION: Make sure all circuits are properly connected before applying power. Avoid contact with the line voltage side after power up. Hot Neutral Multi-way Low-voltage Wiring Load Load 2 Hot SC-100-CP Clock On/Off/Auto Switches The ON/OFF/AUTO manual switches (Figure 5) are used during installation, testing or emergency situations to turn on the connected lighting. Panels are normally shipped with the ON/OFF/AUTO switches in the AUTO position. Multi-way Cap-off Unused Hot Multi-way Cap-off Unused OFF = contacts are open (contactor is energized), the load is OFF AUTO = contacts are controlled by the system clock (SC100-CP) and override inputs 4 Ylw AS-110 Automatic Control Switch Single Switch AS-110 Automatic Control Switch Multiway Switching Application Red Blk Wht Ylw Red Blk Wht Ylw AS-110 Automatic Control Switch Red Blk Wht Ylw AS-110 Automatic Control Switch Red Figure 5 – On/Off/Auto Switches Low-voltage Section Power Out TB1 Return +24VDC TB2 Expansion Terminals Controller Board +24VDC Inputs 1 3 4 CH. H B D CH. D 5 6 E F 7 8 TB3 AC Neu C CH. B CH. G Control Power A 2 CH. C CH. F High-voltage Section Override 24VAC CH. E ON = contacts are closed (contactor is de-energized), the load is ON Load Wht Operation: Automatic Control Switches are manually operated to turn loads on and off. The Basic Control Contactor Panel signals switches to automatically turn on, turn off or delay off. CH. A The ON/OFF/AUTO indication refers to the status of the load being controlled. Load Neutral ON OFF AUTO The SC-100-CP clock is normally preinstalled in HINCPxxxxC-115 interiors. If adding the clock to an exisiting panel, simply mount the clock on the mounting studs in the upper left side of the interior using the screws provided. All power to the panel should be off while installing the clock. Next, plug the provided ribbon cable from the clock into the 10-pin connector labeled J9 on the circuit board. Do not plug the clock into the circuit board with power applied, or you may cause damage to the circuit board. Make sure mounting and connections are secure, then re-apply power to the panel. Neutral Blk H On/Off/Auto Switches HINCP Series Basic Control Contactor Panel Interiors — Installation and Setup If the clock has not been programmed to control the channels, the On/Off/Auto switch may be used to test the circuit. Figure 6 – Expansion Terminal Wiring Run low-voltage interconnecting wiring isolated from other wiring. Expansion TB Terminals CAUTION: If panel wiring is energized, limit exposure to the low-voltage section (left side) of the panel. Common COM Channel A CH.A Channel B CH.B Expansion Terminals Channel C CH.C Channel D CH.D The Expansion Terminals are used to connect the main contactor panel (which includes the clock) to one or more expansion panels (Figure 6). Channels in each panel are electrically linked via Class 2 wiring, so that ON/OFF channel signals from the main panel’s clock are broadcast to the corresponding channel in each expansion panel. Channels in interconnected panels may still be locally controlled using the manual On/Off/Auto switches. (For more details on interconnecting multiple Basic Control Contactor Panels, refer to The Watt Stopper Technical Bulletin # TB148). Channel E CH.E Channel F CH.F Channel G CH.G Channel H CH.H Main Panel (Panel w/clock) Expansion TB Terminals COM CH.A CH.B CH.C To Other Panels as Needed CH.D CH.E CH.F CH.G CH.H Expansion Panel Expansion TB Terminals Operation: On/Off channel signals from Main Panel broadcast to Expansion Panels COM CH.A CH.B CH.C To Other Panels as Needed CH.D CH.E CH.F CH.G CH.H Use the appropriate wire for the number of panels to be interconnected, and the maximum distance from the main panel as shown in the table below right. Expansion Panel Override Inputs Eight override inputs on the circuit board are provided for additional control flexibility. Low-voltage switches, photocells or occupancy sensors may be wired to these inputs. The SC100-CP clock is required to operate the override inputs. Using the clock, the inputs can be assigned to control any channel or group of channels in the panel, which also correspond to channels in any expansion panels. (Refer to the SC100-CP Clock instructions for details on programming override inputs). If there is no clock in the panel, the override inputs are disabled. Any 2-wire momentary or maintained switch or other dry contact device may be wired to the appropriate Override Input and one of the 24VDC tabs as shown in Figure 7. Occupancy sensors (see Figure 9) and photocells (Figure 10) may also be wired to the Override Inputs. Maximum Distance (feet) In Wire Run From Main Panel WIRE GAUGE #18 NUMBER OF PANELS IN WIRE RUN 5 6 7 8 2 3 4 9 10 10000 5000 3500 2500 2000 1700 1500 1300 1100 #16 16000 8000 5500 4000 3000 2500 2300 2000 1800 #14 26000 13000 8500 6500 5000 4000 3500 3000 2500 Figure 7 – Override Switch Wiring Override Inputs +24VDC Input (x) Momentary Pushbutton Switch Auto/On Switch +24VDC Input (x) +24VDC Input (x) Maintained On/Off Switch 5 HINCP Series Basic Control Contactor Panel Interiors — Installation and Setup Auxiliary Power Figure 8 – Auxiliary Power Terminals Low-voltage Section Auxiliary power provided by the panel: 350 mA, 24 VDC and 350 mA, 24 VAC The maximum number of devices that can be powered by the panel depends on the power consumption of each device to be used. Add the current draw of devices to be powered and make sure not to exceed the capacity provided. If the total will exceed the available power, provide an additional power source such as an auxiliary transformer or sensor power pack. Test Return +24VDC 24VAC TB2 Expansion Terminals Control Power TB3 AC A Inputs 1 Neu B 2 CH A C Figure 9 – Occupancy Sensor Wiring Basic Control Contactor Panel has 350mA @ 24VDC available to power sensors. Maximum number of sensors depends on power consumption of sensor models used. Override Inputs Any 24VDC Ceiling/Wall Sensor WARNING: Do not touch line voltage wiring (right side of the panel) after power is restored. When testing is completed, return all On/Off/Auto switches to the Auto position. Controller Board Override +24VDC When all wiring is completed, restore power. Verify that connected loads can be operated by the appropriate channel by manually switching the On/Off/Auto switches between On and Off. Power Out TB1 Auxiliary Power Out Terminals High-voltage Section ON OFF AUTO For devices requiring auxiliary power, such as occupancy sensors and photocells, terminals on the circuit board are provided (see Figure 8). Control Output Blu Common Blk +24VDC Red Input (x) TB-1 Power Out Return +24VDC Isolated Relay Any 8-Wire 24VDC Occupancy Sensor 1-Brn Normally Closed 2-Red Common 3-Orn Normally Open Control Output Override Inputs Common TB-1 Power Out 4-Ylw 5-Grn 6-Blu 7-Vio Program the System 8-Gry Input (x) Return Light Level Output 24VDC +24VDC +24VDC Common Program the system using the SC100-CP clock. Refer to the Clock instructions for details on programming and testing. Figure 10 – Photocell Wiring Exterior Photocell EM-24A2 Red Red Override Inputs +24VDC Input 1 TB-1 Power Out Blk Blk Return 24VAC Override Inputs Interior Daylighting Input 1 Lightsaver LS-100X Controller Control Output Blu TB-1 Power Out Common Blk +24VDC Red Return 24VDC Basic Control Contactor Panel has 350mA @ 24VDC available to power sensors. Maximum number of sensors depends on power consumption of sensor models used. Set-Up / Operation: Using clock screen and keypad, configure Input #1 as Photocell type and assign control to appropriate channel(s). This will hold OFF any channel scheduled to turn ON until the photocell detects it is dark. Panel Division 888-852-2778 INHINCP 090601