* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download HASS (50-600)-S
Audio power wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Transformer wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electrification wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Stepper motor wikipedia , lookup
Ground (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power engineering wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electrical ballast wikipedia , lookup
Power inverter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrical substation wikipedia , lookup
Current source wikipedia , lookup
History of electric power transmission wikipedia , lookup
Schmitt trigger wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power MOSFET wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Distribution management system wikipedia , lookup
Surge protector wikipedia , lookup
Power electronics wikipedia , lookup
Voltage regulator wikipedia , lookup
Current mirror wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Current Transducer HASS 50 .. 600-S For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IPN = 50 .. 600 A All data are given with RL = 10 kΩ Electrical data Primary nominal Primary current rms current measuring range IPN (A) IPM (A) 50 ±150 100 ±300 200 ±600 300 ±900 400 ±1100 500 ±1100 600 ±1100 GTh Theoretical sensitivity @ IPN Vout Analog output voltage @ IP Vref Reference voltage 1) Output voltage Output impedance Load impedance RL Load resistance Rout Output internal resistance CL Capacitive loading (±20 %) UC Supply voltage (±5 %) 2) IC Current consumption @ UC = 5 V Type HASS 50-S HASS 100-S HASS 200-S HASS 300-S HASS 400-S HASS 500-S HASS 600-S 0.625 V/ IPN VOE ±(0.625·IP/ IPN)V 2.5 ±0.025 V typ. 200 Ω ≥200 Ω ≥2 kΩ <5 Ω = 4.7 nF 5 V 19 (typ) mA 25 (max) mA Accuracy - Dynamic performance data XAccuracy 3) @ IPN, TA = 25° C ≤±1 % εL Linearity error 0 .. IPN ≤±0.5 % 0 .. IPM ≤±1 % TCVOE Temperature coefficient of VOE(Vout - Vref @ IP = 0) ≤±0.1 mV/K TCVref Temperature coefficient of Vref ≤±190 ppm/K TCG Temperature coefficient of G ≤±250 ppm/K VOE Electrical offset voltage @ IP = 0, TA = 25 °C Vref ±0.015 V VOM Magnetic offset voltage @ IP = 0 after an overload of IPM <±0.4 % tra Reaction time to 10 % of IPN step <3 µs tr Step response time to 90 % of IPN HASS 50-S<4 µs others <3.5 µs di/dtdi/dt accurately followed IPN ≥100 A 100 A/µs IPN <100 A IPNA/µs Vno Output voltage noise (DC .. 20 MHz) <40 mVpp BW Frequency bandwidth (-3 dB) 4) DC .. 240 kHz Features ●● Hall effect measuring principle ●● Galvanic separation between primary and secondary circuit ●● Insulation test voltage 3300 V ●● Low power consumption ●● Single power supply +5 V ●● Fixed offset & sensitivity ●● Insulating plastic case recognized according to UL 94-V0. Advantages ●● Easy installation ●● Small size and space saving ●● Only one design for wide current ratings range ●● High immunity to external interference ●● Internal & external reference. Applications ●● AC variable speed drives and servo motor drives ●● Static converters for DC motor drives ●● Battery supplied applications ●● Uninterruptible Power Supplies (UPS) ●● Switched Mode Power Supplies (SMPS) ●● Power supplies for welding applications. Application domain ●● Industrial. 74.71.25.000.0, 74.71.34.000.0, 74.71.44.000.0, 74.71.46.000.0, 74.71.48.000.0, 74.71.50.000.0, 74.71.52.000.0 5November2014/Version 17 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Current Transducer HASS 50 .. 600-S General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standard Notes:1) 2) 3) 4) -40 .. +105 °C -40 .. +105 °C 55 g EN 50178: 1997 It is possible to overdrive Vref with an external reference voltage between 0.5 - 2.65 V providing its ability to sink or source approximately 5 mA Maximum supply voltage (not operating) <6.5 V Excluding offset and magnetic offset voltage Small signal only to avoid excessive heatings of the magnetic core. Insulation coordination U d Ue ÛW dCp dCI CTI Rms voltage for AC insulation test, 50 Hz, 1 min Partial discharge extinction rms voltage @ 10 pC Impulse withstand voltage 1.2/50 µs Creepage distance Clearance distance Comparative Tracking Index (group I) 3.3 >1 6 Min >5.5 >5.5 >600 kV kV kV mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ●● Over voltage category OV 3 ●● Pollution degree PD2 ●● Non-uniform field EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Basic insulation 600 V 600 V Reinforced insulation 300 V 150 V dCp, dCI, ÛW Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation.A protective housing or additional shield could be used. Main supply must be able to be disconnected. 5November2014/Version 17 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Dimensions HASS 50 .. 600-S (in mm) 22.8 16 Connection Terminal pin1: Terminal pin 2: Terminal pin 3: Terminal pin 4: d4.5 10.4 2.5 20 R5.2 Vref (IN/OUT) Output 0V +5 V Ip 4.8 3 1 4 Molex 5 d2.5 Required connection circuit Terminal Pin 1 Vref(IN/OUT) 2 Output 3 0V 4 +5V V (IN/OUT) ref 1...Vref(IN/OUT) Output R =10Kohm L 0V 2...OUTPUT +5V 3...0V 4...+5V Operation principle +UC Vout Vref (IN/OUT) 0V 5November2014/Version 17 5 20 40 +/-0.5 HASS 9.8 R0.5 10.4 30 +/-0.5 20.4 Mechanical characteristics ●● ●● ●● ●● ●● General tolerance Aperture for primary conductor Transducer fastening Recommended fastening torque Connection of secondary Remarks ±0.5 mm 20.4 × 10.4 × 0.5 mm M4 <1.5 N·m Molex 5045-04A ●● IS is positive when IP flows in the direction of the arrow. ●● Temperature of the primary conductor should not exceed 120 °C. ●● This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. ●● Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: Products/Product Documentation. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com