* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Voltage Transducer LV 25-P/SP2
Ground loop (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power engineering wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Power inverter wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Thermal runaway wikipedia , lookup
Ground (electricity) wikipedia , lookup
Three-phase electric power wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Stepper motor wikipedia , lookup
Electrical substation wikipedia , lookup
Distribution management system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Transformer types wikipedia , lookup
Schmitt trigger wikipedia , lookup
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Current source wikipedia , lookup
Power electronics wikipedia , lookup
Voltage regulator wikipedia , lookup
Power MOSFET wikipedia , lookup
Buck converter wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Surge protector wikipedia , lookup
Stray voltage wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Voltage Transducer LV 25-P/SP2 IPN = VPN = For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). 10 mA 10 .. 1500 V 16073 Electrical data IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with ± 15 V ISN KN VC IC Vd @ ± 10 mA max @ ± 14 mA max Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test , 50 Hz, 1 mn 10 mA 0 .. ± 14 mA R M min R M max ε Overall Accuracy @ IPN , TA = 25°C Linearity error L • Closed loop (compensated) voltage transducer using the Hall effect • Insulated plastic case recognized 343 183 Ω Ω 25 2500 : 1000 ± 15 10 + IS 4.1 mA Special features V mA kV • Vd = 4.1 k V • TA = - 40°C .. + 85°C • Railway equipment. 100 100 according to UL 94-V0. Principle of use Accuracy - Dynamic performance data XG Features • For voltage measurements, a current ± 0.8 < 0.2 IO IO T Offset current @ IP = 0, TA = 25°C Thermal drift of IO + 25°C .. + 85°C - 40°C .. + 25°C Max ± 0.15 ± 0.15 ± 0.60 ± 0.10 ± 0.80 tr Response time 1) @ 90 % of VPN 25 proportional to the measured voltage must be passed through an external resistor R 1 which is selected by the user and installed in series with the primary circuit of the transducer. % % Typ mA mA mA µs General data TA TS RP RS m Ambient operating temperature Ambient storage temperature Primary coil resistance @ TA = 85°C Secondary coil resistance @ TA = 85°C Mass Standards - 40 .. + 85 °C - 45 .. + 90 °C 300 Ω 117 Ω 22 g EN 50155 : 1995 Advantages • • • • • • Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth High immunity to external interference • Low disturbance in common mode. Applications • AC variable speed drives and servo motor drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Power supplies for welding applications. Note : 1) R 1 = 25 kΩ (L/R constant, produced by the resistance and inductance of the primary circuit). 060315/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM page 1/2 w w w .lem.com Dimensions LV 25-P/SP2 (in mm. 1 mm = 0.0394 inch) Bottom view Top view Right view swiss made Standard 00 or N° SP.. Year Week Secondary terminals Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V Connection LV 25-P/SP2 Back view Mechanical characteristics Remark • General tolerance • Fastening & connection of primary • IS is positive when VP is applied on terminal +HT. ± 0.2 mm 2 pins 0.635 x 0.635 mm • Fastening & connection of secondary 3 pins ∅ 1 mm • Recommended PCB hole 1.2 mm Instructions for use of the voltage transducer model LV 25-P/SP2 Primary resistor R 1 : the transducer’s optimum accuracy is obtained at the nominal primary current. As far as possible, R 1 should be calculated so that the nominal voltage to be measured corresponds to a primary current of 10 mA. Example: Voltage to be measured VPN = 250 V a) R 1 = 25 kΩ / 2.5 W, IP = 10 mA b) R 1 = 50 kΩ / 1.25 W, IP = 5 mA Accuracy = ± 0.8 % of VPN (@ TA = + 25°C) Accuracy = ± 1.6 % of VPN (@ TA = + 25°C) Operating range (recommended) : taking into account the resistance of the primary windings (which must remain low compared to R 1, in order to keep thermal deviation as low as possible) and the isolation, this transducer is suitable for measuring nominal voltages from 10 to 1500 V. 060315/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM page 2/2 w w w .lem.com