Download Company - Galaxy Control Systems

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Decibel wikipedia , lookup

Electrical substation wikipedia , lookup

Islanding wikipedia , lookup

Power factor wikipedia , lookup

Voltage optimisation wikipedia , lookup

Wireless power transfer wikipedia , lookup

Standby power wikipedia , lookup

Audio power wikipedia , lookup

Power electronics wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Electrification wikipedia , lookup

Rectiverter wikipedia , lookup

Electric power system wikipedia , lookup

History of electric power transmission wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Power engineering wikipedia , lookup

Power over Ethernet wikipedia , lookup

AC adapter wikipedia , lookup

Transcript
Low Voltage AC, DC, PoE
Power Management Systems
About LifeSafety Power…
Innovative US manufacturer with extensive portfolio of smart, low voltage
AC, DC, and PoE power management systems
Industry Firsts
Intelligence
- IP addressable power systems
- Power health monitoring and reporting
- Smart battery charging to extend battery life
Customer-first philosophy
- Product modularity/scalability • reduces field inventory significantly
- Easily expandable • customize a system to the job requirements
- Factory pre-wiring • minimizes tech labor, speeds installation time, increases reliability
- Lifetime warranty, advanced replacement • customer first philosophy
Power systems that increase profits and generate RMR
- Web monitoring and reporting • typical service functions performed remotely
- Proactive power health management • suite of managed diagnostic services can be added to annual
maintenance contracts
Award Winning
Innovation…
Same features on every power supply
Network
Interface
Full power
Independent charger
no derating
longer equipment & battery life
120VAC
230VAC
Multi-Listed PS
Access/Security/CCTV/Fire
Every FPO
Fire Alarm Interface
Multiple Outputs
• Continuous
• Resettable
FLEXPOWER Listings
Use the same power supply for
Access, Fire, Security, CCTV, Mass Notification
US
UL 294, Standard for Access Control System Units
UL603, Standard for Safety Power Supplies for Use with Burglar-Alarm Systems
UL1076, Proprietary Burglar Alarm Units and Systems
UL864, Control Units and Accessories for Fire Alarm Systems
UL1481, Standard for Power Supplies for Fire-Protective Signaling Systems
UL2044, Standard for Safety Commercial Closed-Circuit Television Equipment
UL2572, Control and Communications Units for Mass Notification Systems
CSFM, California State Fire Marshal
Canada
ULC S319, Electronic Access Control Systems
ULC S318, Power Supplies for Burglar Alarm Systems
ULC S527, Standard for Control Units for Fire Alarm Systems
CSA, Canadian Standards Association
Ontario Electrical Safety Authority (ESA)
Modular Portfolio
The “Building Blocks”
Power Supplies
AC Transformers
Smart
Management
Distribution
PoE
Modularity Provides Multiple Options
Access control
2, 4, 8, 12, 16 or more doors…
single, dual, or multi voltage
up to 20A/12V, 10A/24V
Network monitoring options
wallmount / rackmount (16)
Security - DC
Up to 20A@12V
8 to 48 distribution wallmount
8 – 16 rackmount
PoE
CCTV
8 – 16 POE+ Midspans
100 – 900VA
8 to 96 outputs wallmount
8 – 24 outputs rackmount
8 – 16 POE+ Midspans
Singleport injector / extractor
Power Supplies






Two board footprints.. four power levels.. same features
Part number = Power delivered
Current doubles at 12V setting
Dual outputs / 2A Charger
IP Ready
Multi-listed
FPO25 (25W
FPO75 (75W
2A/12V, 1A/24V) (AL300)
6A/12V, 3A/24V) (AL400)
FPO150 (150W 12A/12V, 6A/24V) (AL600, AL1012)
FPO250 (250W 20A/12V, 10A/24V) (AL1024)
Accessory Options
DISTRIBUTION MODULES
C4 / C4P
C8 / C8P
D8 / D8P
B100
(ACM4)
(ACM8)
SECONDARY VOLTAGE
adjustable DC-DC 5 – 18VDC@4A
PN Decoding
C = Control
D = Distribution
F = FAI
4/8= outputs
P = PTC style
SMART MANAGEMENT
(PD8)
NL2
Two port network
communication
F8 / F8P (MOM5)
NL4
Four port network
communication
M8 / M8P
Requires NL4
Enclosure Options
Part Number Builds Your System
INDUSTRY
Quick
Pick GuideCOMPARISON
- 4/8 Door Access
EQ Cost <$145 FPO75-E1 6A/12V PS/enclosure




On board FAI, 1A micro charging circuit, dual outputs
110/230VAC, Multi-listed
IP ready with optional network module
Listed to all standards
EQ Cost <$280 FPO75/150 vs AL400ULX & AL600ULX






One enclosure vs two
One conduit drop vs two
Less wall space
Easy to expand with accessories
IP ready… and more
Listed to all standards
4 Door Access
Access Power
FPO75-B100C4E1
2A/12V & 2A/24V
Lock Power
two (2) AC drops
two (2) enclosures
two (2) battery sets





One enclosure
One AC drop
One battery set
Pre-wired LSP boards
Order as E2 for larger enclosure
 Saves wall space, installation time, system cost
 Easy upgrade to remote power management for
 Remote service and reporting
 Power cycle outputs over the web
 Auto test battery condition remotely
 Time to service notification
8 Door Access
Access Power
FPO150-B100C8E2
4A/12V & 4A/24V
Lock Power
two (2) AC drops
two (2) enclosures
two (2) battery sets




One enclosure
One AC drop
One battery set
Pre-wired LSP boards
 Saves wall space, installation cost, system cost
 Distribution expansion room
 Easy upgrade to remote power management
FLEXPOWER managed power
 Service system anywhere, instantly … PC, iPad, Smartphone
 Customize battery and power management
 Set proactive notifications email / SNMP
UCB Medical Center
Garage Level 5
Door Strike (over current) 09:10AM 12/15/13
Battery Service due 12/31/14
45 Park Avenue Center
Main Reception /Access Panel #503
AC LOSS
12/19/14 3:43AM
AC RESTORE 12/19/14 4:07AM
FLEXPOWER managed power
QUICKER RESPONSE, SMARTER DISPATCHING
 Power cycle frozen devices remotely - saves on-site service calls
 Detect, test and report standby battery health
 Review time/date stamped event logs
UCB Medical Center
Garage Level 5
Door Strike (over current) 09:10AM 12/15/14
Battery Service due 12/31/14
45 Park Avenue Center
Main Reception /Access Panel #503
AC LOSS
11/19/14 3:43AM
AC RESTORE 11/19/14 4:07AM
15
PowerCom Monitoring Dashboard
Browser-based
 Easy set up
 Live – quick access status screen
 Configure reporting detail
Remote Service – saves time and money!





Set alerts
Diagnose trouble reports
Remote test batteries
Power cycle outputs
Review and capture event log detail
… simply smarter power
PowerCom Monitoring Dashboard
Power Supply Dashboard
… simply smarter power
17
PowerCom Monitoring Dashboard
Managed Outputs Dashboard
Reports if device
voltage or current goes out of spec
… simply smarter power
18
PowerCom Monitoring Dashboard
SNMP or EMAIL Notification
√
√
√
Notification
proactively know when locks or cameras
draw outside their rated current
Normal
Range
…and replace them before
they fail
time
Notification
… simply smarter power
19
IP Video
Managed PoE Midspan Injectors
All units include battery backup & remote monitoring!
 120/230VAC or 48VDC operation
 Power and data to PoE devices at full 32W/port
 10/100/100Base-T Gigabit support
 Monitor and Manage individual outputs online
 Built in 48V battery charger for cost
effective back-up
 View and manage status from any browser across devices
 Instant alerts via email / SNMP on output trouble
 Remote reset - saves onsite visit just to recycle power!
21