* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download optical sensor power supplies
Three-phase electric power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power factor wikipedia , lookup
Standby power wikipedia , lookup
Wireless power transfer wikipedia , lookup
Utility frequency wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power inverter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Power over Ethernet wikipedia , lookup
Audio power wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power engineering wikipedia , lookup
Buck converter wikipedia , lookup
Power electronics wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Alternating current wikipedia , lookup
Power supply unit (computer) wikipedia , lookup
Power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Mains electricity wikipedia , lookup
COMPONENT OPTICAL SENSOR POWER SUPPLIES Power supply options for the CS120, CS125, CS140 and PWS100 CS140 Background Luminance Sensor CS125 Present Weather Sensor Overview There are 3 options available for powering Campbell Scientific optical sensors. They may also be used for other equipment requiring similar power. The CS120A PSU kit, 010818 and PWS100 PSU kit, 010498 are kits including a DIN-rail mounting switch mode convertor. They both provide 24VDC. These are intended to be installed within an enclosure (not included) either alone or along with other equipment such as data loggers or modems. The Power Supply Units 010470 and 010479 in contrast are supplied with an enclosure. The Power Supply Unit type 010479 has a PS150 regulator and back-up battery to provide an additional backed-up 12V supply. CS120A PSU kit, 010818 Specifications This is a kit of parts including: • A DIN rail mounting mains to 24V DC convertor • DIN rail, glands, labels. • The cost of assembly into an enclosure. Input Voltage requirements: 90-132/180-264 V AC, auto select Current requirements: 2.20 A at 115 V AC, 0.83 A at 230 V AC typical. Input frequency 47-63 Hz It does NOT include an enclosure or battery back-up. This is intended to power the CS120A, CS125 or CS140 products or other equipment with similar requirements. It can power the hood heaters and electronics of a CS120A, CS125 or CS140. It can also power a PS150 power supply with a back-up battery to power the sensor during short power supply interruptions. Output 24V DC +/-1% 5A maximum Operating temperature range -35°C to +50°C It can power both a CS120A/CS125 visibility sensor and a CS140 luminance sensor if both need to be co-located. More info: +44(0) 1509 828 888 www.campbellsci.eu/optical_sensor_power_supplies PWS100 PSU kit, 010498 Specifications This is a kit of parts including:• A DIN rail mounting mains to 24V DC converter • DIN rail, glands, labels • The cost of assembly into an enclosure. Input Voltage requirements: 90-132/180-264 V AC, auto select Current requirements: 4.00 A at 115 VAC, 1.55 A at 230 V AC typical. Input frequency 47-63 Hz It does NOT include an enclosure or battery back-up. This is intended to power the PWS100 or other equipment with similar requirements. The 24V DC supply can power the hood heaters and electronics of a PWS100. Alternatively it can power a PS150 power supply with a back-up battery to provide a 12V supply to power the sensor during short power supply interruptions. Output 24V DC +/-1% 10A maximum Operating temperature range -35°C to +50°C Power supply unit 010479 Power supply unit 010470 This is intended for use with the PWS100 present weather sensor or any application requiring a high current at 24V DC and a battery-backed 12V supply. It is supplied in an ENC 12/14 enclosure. There is some spare space inside for communication equipment. This is intended for use with the CS120A, CS125 or CS140 Visibility, present weather or background luminance sensors sensor or any application requiring a high current at 24V DC. It is supplied in an ENC 10/12 enclosure. There is some spare space inside for communication equipment. Specifications It can power both a CS120A or CS125 visibility sensor and a CS140 if both need to be co-located. Input Voltage requirements: 90-132/180-264 V AC, auto select Current requirements: 4.00 A at 115 V AC, 1.55 A at 230 V AC typical. Input frequency: 47-63 Hz. Outputs Output 1: 24V DC +/-1% 10A maximum Output 2: Nominal 12 V DC from 7Ah lead acid battery 4 A nominal maximum output via.Self-Resettable Thermal Fuse Hold Current Limits <20°C: > 4 A 20°C: 4.0 A 50°C: 3.1 A 60°C: 2.7 A Specifications Input Voltage requirements: 90-132/180-264 V AC, auto select Current requirements: 2.20 A at 115 V AC, 0.83 A at 230 V AC typical. Input frequency: 47-63 Hz. Outputs Output: 24V DC +/-1% 5A maximum Dimensions 25.4 x 30.5 x 11.4 cm Environmental specifications -25°C to +50°C Battery back up 12V, 7Ah Dimensions 30.5 x 35.6 x 14 cm Environmental specifications -25°C to +50°C PWS100 Present Weather Sensor 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | [email protected] | www.campbellsci.eu UK | AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | SE ASIA | SOUTH AFRICA | SPAIN | USA © 2012 Campbell Scientific October 20, 2016