Download Lunera CFL LED GX23 2-Pin

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Resistive opto-isolator wikipedia , lookup

Electric power system wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Stray voltage wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Power engineering wikipedia , lookup

Automotive lighting wikipedia , lookup

Electrification wikipedia , lookup

History of electric power transmission wikipedia , lookup

Mains electricity wikipedia , lookup

Electrician wikipedia , lookup

LED lamp wikipedia , lookup

Home wiring wikipedia , lookup

Oil lamp wikipedia , lookup

Safety lamp wikipedia , lookup

Electrical wiring wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Electrical ballast wikipedia , lookup

Transcript
LUNERA CFL LED LAMP GX23 (GEN 4)
Installation Guide
The LUNERA CFL LED GX23 Gen 4 can be installed directly using the existing CFL ballast (ballast-driven plug
and play installation), or it can be 120V/277V line-driven. In this installation guide, line-driven installation is
presented, which includes bypassing the installed ballast or removing the installed ballast entirely to reduce
total fixture power consumption.
Installation Instructions: Line-Driven or Ballast-Bypass Driven 120V/277V
Note: Bypass instructions apply only to GX23 base Lunera CFL LED lamps.
1. Make sure the circuit breaker that supplies power to the fixture is turned off
2. Remove trim and existing lamp(s) from recessed fixture. Drop housing from plaster frame.
3. Remove inner junction box cover and disconnect ballast from input wiring and lampolder leads.
Dispose of removed ballast and lamps in accordance with government regulations in your area.
4. Connect input wiring to lampholder leads according to the appropriate diagram below (Figures 1 and 2).
Place wires and connection back in wiring box and replace cover.
Retrofit with
Base)
Figure 1.
1. Retrofit
withOne
OneLamp
Lamp(GX23
(GX23
Base)
BEFORE
BEFORE
BLACK
WIRING: (1) TWIN LAMP
Figure 2.
Two
Lamps
(GX23
Base)Base)
Figure
2. Retrofit
Retrofitwith
with
Two
Lamps
(GX23
BEFORE
BEFORE
BALLAST
BLACK
WHITE
WIRING: (2) TWIN LAMP
BALLAST
BLUE
WHITE
RED
AFTER
AFTER
WIRING: (1) TWIN LAMP
AFTER
AFTER
WIRING: (2) TWIN LAMP
BLACK
BLACK
WHITE
BLUE
WHITE
RED
5. Reinstall housing and trim.
6. Install your new Lunera LED PL lamps.
7. Apply relamping Label on a visible location inside the fixture.
8. Turn power on at the breaker box and turn on the lights.
www.lunera.com
T (650) 241-3875
F (650) 362-1987
1 of 2
LUNERA CFL LED GX23
2 of 3
General Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
DANGER - RISK OF SHOCK - DISCONNECT POWER BEFORE INSTALLATION
WARNING - Risk of fire or electric shock, LED Retrofit Kit installation requires knowledge of luminaires
electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
WARNING - Risk of fire or electric shock. Install this kit only in luminaires that have the construction
features and dimensions shown in the photographs and/or drawings and where the input
rating of the retrofit kit does not exceed the input rating of the luminaire.
WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or
other sharp objects.
CAUTION - IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION
(BUZZING, FLICKERING, ETC.) IMMEDIATELY TURN OFF POWER, REMOVE
LAMP FROM LUMINAIRE AND CONTACT MANUFACTURER.
CAUTION - RISK OF FIRE - IF INSTALLING THIS LAMP IN A PRE-HEAT LUMINAIRE
REMOVE THE AUTOMATIC STARTERS FROM THEIR HOLDERS BEFORE
INSTALLING LAMP.
CAUTION - RISK OF FIRE - DO NOT INSTALL THIS LAMP IN A PRE-HEAT LUMINAIRE.
Only those open holes indicated in the photographs and/or drawings may be made or altered as a result
of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit
installation.
Installers should not disconnect existing wires from lampholder terminals to make new connections at
lampholder terminals. Instead, installers should cut existing lampholder leads away from the lampholder
and make new electrical connections to lampholder lead wires by employing applicable connectors.
For Technical Support:
https://lunera.com/freshdesk.com/support/home
www.lunera.com
T (650) 241-3875
LUNERA CFL LED GX23
3 of 3
Intended Applications
When installed as Line-Diven, the Lunera CFL LED GX23 is designed for common commercial fixtures with
2-pin (GX23) CFL sockets that meet the following characteristics:
Lamp
Mount
Power Sources
Controls
5 Watts
Horizontal
Direct Line Voltage
Rocker Switch
(non dimming)
Fixtures
Socket
Dimmers
Lensed / non-lensed
downlights
G2-pin GX23
(with compatible
dimming ballast)
For Technical Support:
https://lunera.com/freshdesk.com/support/home
www.lunera.com
03/17/2016 - R1
© 2016 Lunera ® Lighting
T (650) 241-3875