* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download mandatory - Energy Measure To Save
Electronic engineering wikipedia , lookup
General Electric wikipedia , lookup
Current source wikipedia , lookup
Electronic paper wikipedia , lookup
Ground (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Transformer wikipedia , lookup
Electric power system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Electrification wikipedia , lookup
Power electronics wikipedia , lookup
Electrical substation wikipedia , lookup
Power engineering wikipedia , lookup
Voltage regulator wikipedia , lookup
Electrical ballast wikipedia , lookup
War of the currents wikipedia , lookup
Three-phase electric power wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Distribution management system wikipedia , lookup
Rectiverter wikipedia , lookup
Opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Surge protector wikipedia , lookup
Alternating current wikipedia , lookup
Street light wikipedia , lookup
LIGHTING –MANDATORY SAFETY & ENERGY SAVING PRACTICE Improving efficiency of energy usage by RETROFIT:– Fast response Voltage Regulation by the individual consumer in their lighting in domestic, commercial and industrial segments leads fewer lighting failures, less fire hazards and achieves greater power savings! EXISTING PRACTICE:Compared to any other electrical loads like motor, pump, fan etc they are classified as heavy and variable loads where as Lighting is a soft load which takes only fixed watts for given volts all the time it is ON. Now we hear many electricity related fires, mishaps etc invariably the diagnosis points to lighting is the one of major causes. Especially the HID High Intensity Discharge lamps fail faster due to heavy voltage fluctuations and this needs to be avoided. When EB power interruptions are more & when power is resumed, definitely the tube lights etc fail faster due to rush of heavy voltages. This voltage become normal after the normal loading of heavy loads, but before that our lighting becomes victim & fail. PROPOSED PRACTICE:If we retrofit in our lighting circuit in our domestic, commercial and in industry; an Automatic Servo stabilizer to operate our tube lights etc at 210 volts instead of 240 volts now, then we can avoid fire hazards, increase the life of light bulbs thus reducing & postponing light failure, power saving around 10 %. The probable burning hours of bulb goes up by six times when operated at 205 volts constantly instead of fluctuating voltages above 240 volts. LIGHTING SURGE PROTECTION:In case of domestic, industry, or commercial segments where in sophisticated electronic equipments are put to use, it is recommended to retrofit Surge Protection Switch gear at the incoming of the Servo Stabilizer circuit. This will protect the lighting, electronic systems downstream against any switching surges occurring at the incoming of premises. They are parallel protection mechanism and act in parallel to relieve the incoming volt surges to earth and allowing the normal voltages to enter into the systems. Their response time to relieve transients is in the order of micro seconds and hence protection to downstream lighting, equipments is ensured. WRONG NOTION BY THE INDUSTRY CONSUMER:Now the trend in each small, medium scale industry itself; they go in Automatic On Load Tap Change over OLTC transformer when replacing their old Off Load Tap Changer type transformer from 250 KVA rating onwards. But the consumer thinks because the OLTC is there now, the voltage from EB will be regulated at the transformer itself hereafter. The consumer thinks that his lighting is protected and the saving achieved. But it is not so! The response of OLTC to sudden voltage fluctuations in the incoming is very slow say by few MINUTES. Before the voltage regulation happens at OLTC, delicate electronic loads like the lighting, High discharge lamps with electronic ballast, delicate electronic loads etc fail due to voltage fluctuations. Even if the consumer has built in OLTC in the transformer, it is safe to retrofit Servo stabilizer with Surge Suppressors for lighting circuits and this stabilizer response time or the voltage correction rate is up to 60 volts per SECOND. Hence the damage to lighting etc equipments is minimized totally. GOVERNMENT INITIATIVE TO MAKE IT MANDATORY:The Ministry needs to take up this action immediately and make it mandatory to retrofit Automatic Servo Stabilizer to light & soft loads especially. This is to protect from breakdowns in lighting, electronic delicate loads in manned, unmanned areas, avoiding electric related fire hazards etc and as well ensure power saving up to 20 % possible! Unless this mandatory electrical safety in lighting circuits is enforced, we will not take the initiative to retrofit the Servo stabilizers in the lighting circuits! Please log on to my site www.energymeasuretosave.com for more tips on energy saving.