* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Electrical Power Generation, Transmission, Storage and Utilization
Utility frequency wikipedia , lookup
Power inverter wikipedia , lookup
Audio power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Stray voltage wikipedia , lookup
Wireless power transfer wikipedia , lookup
Power over Ethernet wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Buck converter wikipedia , lookup
Power factor wikipedia , lookup
Overhead power line wikipedia , lookup
Electric power system wikipedia , lookup
Electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power electronics wikipedia , lookup
Electrification wikipedia , lookup
Electrical substation wikipedia , lookup
Electrical grid wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Mains electricity wikipedia , lookup
Power engineering wikipedia , lookup
Electrical Power Generation, Transmission, Storage and Utilization Ray Findlay IEEE 2002 President McMaster University, Canada [email protected] Robert K.Green, President & CEO of UtiliCorp United • “The utility of the future is multinational, carries its expertise into emerging parallel businesses, has the flexibility and willingness to unbundle, adapts readily to new structures and concepts, goes beyond its traditional borders to grow, and is an expert manager of risk.” What’s in the Future? • • • • • • Global power Privatization Consolidation Deregulation Free market competition Emphasis on capital, investment strategy and economics, including cost reduction Technical Requirements • Generation: need the lowest cost generation available to meet demand There are many factors involved in this process, complicated, not only by technical considerations, but also by political considerations: Environmental considerations Maintenance and operating costs Inefficiencies as a result of transmission Regulatory issues Some Elements of the Competitive Power Market • • • • • • • • • Energy network owners - transmission Energy traders Energy brokers Mechanisms for exchange Wholesale energy pricing Cost of energy trading Energy service providers - distribution Retail operations - supply Marketing services Challenges • • • • • • • • • Aging infrastructure Maintenance & scheduling Power Quality & harmonic distortion Advances in machine & drive design Reducing transmission loss System complexity Networked generation distribution Business VS engineering decision-making Educational issues Opportunities • Generation asset management • Efforts to optimize utilization of generation facilities according to market demand • Incentive to increase efficiencies of power plants and systems • Incentive to rationalize maintenance schedules to minimize downtime • Improvement of communications among suppliers, and of monitoring systems Transmission/Network Grids, A Problem • Unbundling the transmission grid from both the generation and delivery creates a problem - by definition it must be a monopoly. • Need to ensure open access • Need for regulation and oversight • Need for maintenance & development of more capability as required • Danger of fragmentation, congestion, tariffs, scheduling difficulties, etc. The Retail Environment • • • • • Role of the retailer One, two, how many bills? Wholesale versus retail Large customers versus small customers Multiple service opportunities: gas, electricity, water, financial services (credit) • Methods of pricing for retail delivery – fixed term pricing – spot market pricing – regulated, capped or open access pricing Control • With large, multi-connected systems inter-tying substantial areas of the globe, communication and control become problems • Dedicated communication lines • Internet operation and control • DC generation/conversion transmission versus AC generation and transmission CoGeneration • Issue of small plants * * * * Methane Wind power Solar power Tidal power • Interconnections as a virtual plant • Control issues • Specialized components Power Quality • Harmonics • Distortion: power electronic loads, adjustable speed drives & switch-mode power supplies • Electromagnetic compatibility • Component magnetics: machines, transformers, ACSR, etc. • Power factor: displacement power factor versus true power factor Power Factor Displacement power factor: PFd = Cos (/VfIf) True power factor: PFt = P/(VrmsIrms) For 100% THD on current, the maximum true power factor will be about 0.71 Measuring Power Quality • • • • Total harmonic distortion Irms/I1 True power factor Communications influence Gw2Ii2/Irms Crest factor Vpeak/Vrms • There are several other special purpose power quality indices. Harmonic Sources • Saturable devices include electrical machines, transformers, some transmission conductors, and fluorescent lights with magnetic ballasting • Power electronic (switching) loads include switch-mode power supplies, PWM converters, voltage source converters, fluorescent lighting with electronic ballasting, computers, etc. • Although not strictly a source, a resonant system can exacerbate harmonics - systems containing both capacitance and inductance. An example is an inductive load with power factor correction. Voltage Sags in a Multisource Environment • Motor starting, transformer energizing, faults and load switching can all lead to voltage sag. • Normal clearing time for a fault is 2 or 3 cycles • Clearing for a motor start can take 10 cycles • For a load switch/transformer energize, it can take 25 - 50 cycles Voltage Sag Mitigation Strategies • Reduce the number of faults. This can be accomplished by upgrading equipment • Improve the system. Loads susceptible to faults should be multi-sourced. Use high-impedance grounding with )Y transformers to reduce the effects of a single phase to ground fault • Interface between system and load - installed additional equipment. Dynamic voltage restorer. • Improve the load equipment Power Acceptability • To ascertain power acceptability we can use power acceptability curves that measure the sensitivity of the load against voltage sags or over-voltages. The curves are logarithmic for time duration to recovery against change in voltage. • Rectifier loads are particularly sensitive to voltage sags DeRegulation & Generators • Particular utilities have standard requirements (called grid codes) for generators before the generator can connect to the grid. • However, between utilities there is, as yet, no consistency among the grid codes used. • Once requirements in a utility are established they may be historical and may revolve around the weakest link in the utility system. • This may cause problems for some units that may be required to conform to the weakest link grid codes. (Extreme frequency deviations, extreme VAR limits, etc.) Resulting Problems • Result is inconsistent standards in delivery • May result in more expensive units to meet the codes • In some areas of operation can lead to extreme anomalies in operation, for example may never operate in the leading PF range. • Difficulties in matching overall system requirements to generator capacity. • Although the machines may be capable of producing the power they may be penalized for not operating in the extremes - hence leading to more expensive power. New Technologies • To develop a rational maintenance schedule we need to make us of new technologies, for example monitoring partial discharges of the stator windings of generators. • Some insulation materials have predictable partial discharge behaviour which may make it possible to determine the state of the winding, as well as the specific aging mechanism. • By keeping a record of PD activity it is then possible to develop a rational maintenance schedule. • This type of monitoring can be set up as an intelligent system to warn of impending winding failure. Partial Discharge Tests • • • • Pulse peak magnitude Pulse polarity Repetition rate Phase location • • • • Plotted results: Pulse height analysis Pulse phase analysis Trends From these plots we can determine: • The overall degradation of the stator winding • The partial discharge activity: the maximum magnitude of pulses with a particular repetition rate • The trend of partial discharge activity which yields the progression of insulation aging • Analysis of the pulse phase plot can pinpoint the location of the activity - slot or endwinding • Pulse patterns reveal the nature of the partial discharge activity, including the predominant sources. Winding Deterioration Factors • • • • • • • • Voltage switches and variations Operating conditions Fluctuations in load Mean operating voltage level Winding temperature Humidity Aging Winding displacement in slot - fit Web-Based Monitoring and Control • The web presents an opportunity for system automation and control. • For large deregulated systems information transfer plays a large part in determining success. • This gives rise to the concept of an on-line System Control and Data Acquisition System (SCADA) . • When combined with an interactive energy management system, we have an effective operating system over long distances and between systems. • To take advantage of this possibility will require substantive changes in individual SCADAs, as well as a very cooperative approach to selecting standards An ACSR Conductor current direction longitudinal flux current in steel core current in aluminum wires circular fulx 54 aluminum conductors in three layers 19 steel conductors, two layers over a single wire COOLTEMP M HT RC EM Predicts conductor behaviour over the life time by introducing statistical distribution of system loads, ambient temperature, and rise of conductor surface over ambient Conductor dimensions Complex Layer’s Current COOLTEMP Electromagnetic Model Heat transfer Model Mag. Field Strength Complex Permeability Data Radial Conduction Model Layer’s temperature Pretensioning variables Stringing variables Mechanical Model Running-out variables Annealing Avg. aluminium temp. Creep Avg.steel temp. Steel Stress current Sag Aluminium Stress Horizontal Tension I total Loop inductance I total j(I +I +I + koI )k ln[Do/(Do-d)] s i m o j(I +I +I + kiI )k ln[(Do-d)/Dm] s i m o j(Is+Ii +koI m )k ln[Dm/(Dm-d)] j(Is+Ii +kiI m)k ln[(Dm-d)/Di] j(I s+koIi )k ln[Di/(Di-d)] j(I +kiI )k ln[(Di-d)/Ds] s i Cicular inductances Resistances Longitudinal inductances d Electromagnetic Model