Download Molded Case Circuit Breakers

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Flexible electronics wikipedia , lookup

Buck converter wikipedia , lookup

Mains electricity wikipedia , lookup

Opto-isolator wikipedia , lookup

Alternating current wikipedia , lookup

Surge protector wikipedia , lookup

Television standards conversion wikipedia , lookup

Rectiverter wikipedia , lookup

Earthing system wikipedia , lookup

Electrical substation wikipedia , lookup

Residual-current device wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Circuit breaker wikipedia , lookup

Transcript
Molded Case Circuit Breakers
Introduction
What’s New?
Sentron Distribution Lug
DIN Rail mounted 120/240 V Breaker
Distribution lugs are now available for
use with Siemens Sentron E, F, J and
L-frame circuit breakers. These lugs are
UL 486-B recognized and are ideal for UL
508 control panel applications to replace
a distribution block. Using the Sentron
distribution lugs can reduce the need for
extra wire stripping. They also reduce
the use of extra crimp connectors
going between the circuit breaker
and distribution block.
The Siemens BQ breakers are now
available in 1- and 2-pole construction,
from 15 to 60 Amps in lug in – lug out
DIN rail mounted configuration. These
breakers, rated 120/240 Volts, are ideal
for applications in control panels and
HVAC, and with their available finger
safe terminal shields can qualify as
service disconnects.
Siemens Energy & Automation is proud
to announce several new products. These
new concepts serve the OEM and power
distribution markets.
WL Power Circuit Breakers
It’s the Circuit Breaker that changes
everything! And it’s armed with a full
array of competitive advantages:
▪ Reliable – increased operations and
better than 1% metering accuracy
▪ Compact – smallest switchgear
footprint in the industry
▪ Easy to Use – straightforward catalog
numbers & selection tools
▪ Modular – drop-in, front-mounted
accessories & field changeable main
contacts
▪ System Solution – Internet/Ethernet,
Modbus and Profibus communications
▪ Safety – customized interlocking and
unique status indicators
Specifications and Applications:
▪ Standards: UL489, UL1066 and ANSI
C37
▪ Frame Ratings: 800A to 5000A
▪ Rated Nominal Voltages: 240, 480 and
600VAC
▪ Interrupting Ratings: from 50KA to
150KA un-fused and 200KA fused
▪ Assemblies: Fixed mounted, draw-out
Circuit Breaker or Non-automatic
Switch
▪ Applicable for all ICCB or RL Breaker
applications
The WL Circuit Breaker may be new to
North America, but it has already been
proven in the field – with two years of
flawless performance in Europe. No
other product on the market today offers
more flexibility or greater reliability.
17/2
CE Marking
A wide range of Sentron® thermal
magnetic circuit breakers has been fully
tested for compliance with the European
community's Low Voltage Directive,
and carry the CE mark, indicating their
compliance with that directive. These are
noted in the Speedfax with the stylized CE in watermark behind the catalog
numbers. Declarations of conformity
are available for these products. A point
of misunderstanding lies in the area of
handle operators. A handle operator
alone, such as that for the Max-flex,
since there is no applicable European
Directive, may not carry the CE mark.
The mark is affixed to the finished
equipment that incorporates the handle,
but not to this component device.
PLC Level Auxiliary Switches
A new family of gold flashed auxiliary
switches for the FD through ND breakers
allows sensing at very low voltage and
currents for interface directly to
programmable logic controllers and other
electronic devices. Standard contacts,
built to switch 120 Volts and higher
currents can be unreliable when the
sensing current is in the milliamp range,
and the sensing voltage is 12 Volts or
lower. These very reliable low level
switches overcome that limitation.
Standard switch contacts should, of
course, continue to be used in standard
current and voltage applications.
NGG Type 125A Frame Circuit Breaker
The new NGG Circuit Breaker is a
compact, industrial design with true
value-added features such as Global
Ratings (UL/CSA/IEC/CE/NOM), flexible
DIN or base mounting without the need
for adapters and UL Listed for field
install-able accessories. This NGG125
has a 25KAIC interrupting rating at
480VAC and features a Quick
Make/Quick Break Trip-free Mechanism.
All this in a 3.0W x 5.4H x 2.8D package.
Please consult your sales office for
availability.
HID Lighting Breakers
Siemens BQD and CQD circuit breakers
have been tested and approved for use
in switching HID lighting. One, two and
three pole breakers from 15A to 50A are
now approved and marked for use in
these high energy lighting systems
where the breakers is used to directly
control the lighting in 120VAC, 240VAC,
277AC or 480/277VAC circuits.
Siemens Canada Limited
Industrial Controls Catalogue
Molded Case Circuit Breakers
Catalog Numbering System
Selection/Application
If used on 250A frame and above means
non-interchangeable trip breaker with
factory assembled frame and trip. Solid
state trip and current limiting (S or C in
first character) are non-interchangeable
only, and the “X” is omitted.
X D
Trip Unit Type
— Omitted – Thermal-Magnetic
S — Sensitrip® Electronic Trip
Sentron Series Type/Interrupting Range
— Omitted – Standard Rating
H — High IC Rating
HH — Extra High IC Rating
C — Highest IC Rating and Current Limiting
Frame Identifier
E — Type ED
F — Type FD
J — Type JD
L — Type LD
LM — Type LMD
M
N
P
R
T
—
—
—
—
—
Type
Type
Type
Type
Type
MD
ND
PD
RD
TD
Maximum Voltage
2 — 240 Vac
4 — 480 Vac
6 — 600 Vac
Number of Poles
1
2
3
9 used to indicate the max. functions for an electronic trip circuit breaker (always 3 poles)
(Specific Application Type)
B — Standard 40°C Breaker
M — Calibrated for 50°C Application
F — Frame Only
T — 40°C Trip Unit Only
W — 50°C Trip Unit Only
S — Molded Case Switch
L — Low Instantaneous Range ETI Breaker
A — Standard Range ETI Breaker
H — High Instantaneous Range ETI Breaker
Maximum Continuous Current Rating
ED Frame — 015, 020, 025, 030, 035, 040, 045, 050, 060, 070, 080, 090, 100, 110, 125
FD Frame — 070, 080, 090, 100, 110, 125, 150, 175, 200, 225, 250
JD Frame — 200, 225, 250, 300, 350, 400
LD Frame — 250, 300, 350, 400, 450, 500, 600
LMD Frame — 500, 600, 700, 800
MD Frame — 500, 600, 700, 800
ND Frame — 900, 100 (1000A), 120 (1200A)
PD Frame — 120 (1200A), 140 (1400A), 160 (1600A)
RD Frame — 160 (1600A), 180 (1800A), 200 (2000A)
TD Frame — 2000, 2500, 3200
Suffix
L — where applicable indicates a breaker shipped with line/loads lugs installed
A — used with a switch to show automatic self protection
Y — 400 Hertz
H — 100% rated
P — Load side lugs only
NOTE:
— Position omitted if not used.
17/4
Siemens Canada Limited
Industrial Controls Catalogue
Molded Case Circuit Breakers
JD 400A Frame Sentron Series
Selection
Type JXD2-A
Blue Label
240V AC, 2-Pole 250V DC Only
Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)
2-Pole (3 Pole Width)
Catalog
List
Number
Price $
JXD22B200■
JXD22B225■
JXD22B250■
JXD22B300
JXD22B350■
JXD22B400
Continuous
Current Rating
@ 40°C
200
225
250
300
350
400
3-Pole
List
Price $
Catalog
Number
JXD23B200
JXD23B225
JXD23B250
JXD23B300
JXD23B350
JXD23B400
Type JXD6-A Blue
600V AC, 2-Pole 250V DC, 3-Pole 500V DC Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)
JXD62B200■
JXD62B225■
JXD62B250■
JXD62B300
JXD62B350■
JXD62B400
200
225
250
300
350
400
Label
JXD63B200
JXD63B225
JXD63B250
JXD63B300
JXD63B350
JXD63B400
Type JD6-A
Blue Label
Interchangeable Trip
Continuous
Current Rating
@ 40°C
Complete Breaker
Unassembled with Lugs
Catalog
List
Number
Price $
Frame Only
Catalog
Number
Trip Unit Only
Catalog
List
Number
Price $
List
Price $
2-Pole 600V AC, 250V DC (3 Pole Width)
200
225
250
300
350
400
JD62B200■
JD62B225■
JD62B250■
JD62B300■
JD62B350■
JD62B400
JD62F400
JD62T200■
JD62T225■
JD62T250■
JD62T300■
JD62T350■
JD62T400
JD63F400
JD63T200
JD63T225
JD63T250
JD63T300
JD63T350
JD63T400
Ordering Information
Complete Breaker Unassembled
with Lugs
Prices of JD6, HJD6, and HHJD6
breakers include frame, trip and
both line and load lugs (TA2J6500).
When ordered by these catalog
numbers, the customer will receive
the frame, trip, and lugs separately
packaged. For applications
requiring different lugs, order
individual items as needed.
Complete Breaker Assembled without Lugs
Prices of JXD6, HJXD6, HHJXD6,
and CJD6 include frame with
non-interchangeable trip unit
installed only. Order required lugs
separately. For line and load lugs
(TA2J6500) installed, add suffix “L”
to catalog number (add 2 times list
price of lugs for each pole).
100% Rated
Types JXD6 and HJXD6 breakers
are available with 100% ratings.
To order add suffix “H” to catalog
number, and 10% to list price.■
100% rated JD breakers require the
use of 90° C Cu cable and lugs
TC1J6600 or TC2J6500.
50° C Applications see page 17/70.
400Hz Applications see page 17/70.
3-Pole 600V AC, 500V DC 200
225
250
300
350
400
JD63B200
JD63B225
JD63B250
JD63B300
JD63B350
JD63B400
Lugs For 75°C Wire Interrupting Ratings
Breaker
Type
JXD2-A
JXD6-A, JD6-A
HJD6-A, HJXD6-A
HHJD6, HHJXD6 CJD6-A
RMS Symmetrical Amperes (KA)
UL 489 AIR (File E10848)
Volts AC
Volts DC
(50/60Hz)
240
065
065
100
200
200
480
—
035
065
100
150
600
—
025
035
050
100
250
30 (2-P)
30 (2-P)
30 (2-P)
—
—
500 —
25 (3-P)
35 (3-P)
—
50 (3-P)
IEC 947-2
Volts AC (50/60Hz)
220/240 380/415
500
lcu
—
065
100
200
—
lcu
—
30
42
65
—
lcs
—
033
050
100
—
lcu
—
040
065
100
—
Cables
per
Lug
1, 2
2
1
TA1L6750 1
1
TC1J6600 1
TC2J6500 1, 2
Compression Lug
CCL600
1
Catalog
Number
TA2J6500
lcs
—
20
33
50
—
lcs
—
15
21
33
—
Wire
Range
#3/0-500 kcmil Cu
#4/0-500 kcmil Al
250-500 kcmil Al
500-750 kcmil Al
500-600 kcmil Cu
#3/0-600 kcmil Cu
#3/0-500 kcmil Cu
List
Price $
500 kcmil Cu/Al
Instantaneous Adjustment Trip Range
Breaker Ampere
Rating
200-300
350-400
Nominal Instantaneous Values
+20%
Tolerance
Low
2
3
4
5
6
7
1250
2000
1960
3140
2140
3430
2320
3710
1430
2290
1610
2570
■ Built to order. Allow 2–3 weeks for delivery.
Type
JXD2 and JXD6 circuit breakers are UL Listed for
reverse feed applications.
When
wired as shown on page 17/3, this circuit breaker
is UL listed and rated for use on 500V DC ungrounded
UPS systems only.
17/26
1790
2860
+20%
Tolerance
High
2500
4000
See
Note: A, page 17/67.
type circuit breakers meet the UL criteria for
“current limiting” at 240 and 480V AC.
HACR rated.
Note: JD frame qualified to UL489 supplement B
“NAVAL.” See page 17/70 for additional information.
HHJD6
Modifications page 17/70
Accessories pages 17/29 and 17/71 to 17/77
Siemens Canada Limited
Industrial Controls Catalogue
Enclosed Circuit Breakers
Complete Assemblies—Molded Case Circuit Breakers
Siemens Enclosed Circuit Breaker
Complete Assemblies consist of a thermal
magnetic molded case circuit breaker
frame, trip unit, enclosure and standard
line and load pressure wire connectors —
assembled and shipped as one unit from
the Siemens modification center. For
service equipment or applications
Selection
requiring a solid neutral, neutrals must be
priced and ordered separately except as
noted.
To order, select the appropriate prefix
from the table below and place it in front
of the desired non-interchangeable trip or
interchangeable trip circuit breaker catalog
number. For circuit breaker selection,
refer to pages 6-20 thru 6-53.
Note: Lead times are determined based
on availability of components.
Items marked with ■ or ▲ in this
section may contain components
that are not normally stocked.
Catalog Numbering
Prefix
Enclosure Type
E1S
Type 1 Surface
E1F
Type 1 Flush
E3R
Type 3R
Example:
Catalog number E1SJD63B400 consists of:
(1)
(1)
(1)
(6)
E12
Type 12
E4X
Type 4X Stainless Steel
JD63F400 frame
JD63T400 trip unit
J6N1 enclosure
TA2J6500 wire connectors
Selection And Pricing By Enclosure Type
Circuit Breaker
Breaker
Frame
QJ2
QJH2
ED4
ED6
Type
3R
Neutrals
Type
12
Type
4, 4X
2
60-225
617.00
800.00
NA
NA
3
60-225
1268.00
1490.00
NA
NA
2
60-225
1177.00
1360.00
NA
NA
3
60-225
1689.00
1911.00
NA
NA
2
60-225
1410.00
1593.00
NA
NA
3
60-225
2085.00
2307.00
NA
NA
2
2
15-60
70-100
416.00
590.00
664.00
838.00
516.00
690.00
2980.00
3154.00
3
3
15-60
70-100
550.00
726.00
798.00
974.00
650.00
826.00
3114.00
3290.00
2
2
2
15-60
70-100
110-125
638.00
795.00
1578.00
886.00
1043.00
2010.00
738.00
895.00
1748.00
3202.00
3359.00
4026.00
3
3
3
15-60
70-100
110-125
793.00
908.00
1776.00
1041.00
1156.00
2208.00
893.00
1008.00
1946.00
3357.00
3472.00
4224.00
2
2
15-60
70-100
726.00
878.00
974.00
1126.00
826.00
978.00
3290.00
3442.00
3
3
3
15-60
70-100
110-125
883.00
1069.00
2041.00
1131.00
1317.00
2473.00
983.00
1169.00
2211.00
3447.00
3633.00
4489.00
Discount Schedule F
Lug
Catalog
Number
(included)
Catalog
Number
List
Price $
TA1Q300
TA1Q300
Included with
enclosure
TA1Q300
Enclosed
Circuit Breakers
ED2
Ampere
Rating
Type 1
Surface
or
Flush
5
QJ2-H
Number
of
Poles
List Price $ — Complete Assembly
15-25A
SA1E025
30-60A
Line LN1E100
Load LD1E060
70-100
LN1E100
Catalog Number
W53045
included with
enclosure
110-125A
TA1E6125
Siemens Electrical Distribution Products Catalog 2006 SPEEDFAX
5-3