* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Molded Case Circuit Breakers
Flexible electronics wikipedia , lookup
Buck converter wikipedia , lookup
Mains electricity wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Surge protector wikipedia , lookup
Television standards conversion wikipedia , lookup
Rectiverter wikipedia , lookup
Earthing system wikipedia , lookup
Electrical substation wikipedia , lookup
Residual-current device wikipedia , lookup
Molded Case Circuit Breakers Introduction What’s New? Sentron Distribution Lug DIN Rail mounted 120/240 V Breaker Distribution lugs are now available for use with Siemens Sentron E, F, J and L-frame circuit breakers. These lugs are UL 486-B recognized and are ideal for UL 508 control panel applications to replace a distribution block. Using the Sentron distribution lugs can reduce the need for extra wire stripping. They also reduce the use of extra crimp connectors going between the circuit breaker and distribution block. The Siemens BQ breakers are now available in 1- and 2-pole construction, from 15 to 60 Amps in lug in – lug out DIN rail mounted configuration. These breakers, rated 120/240 Volts, are ideal for applications in control panels and HVAC, and with their available finger safe terminal shields can qualify as service disconnects. Siemens Energy & Automation is proud to announce several new products. These new concepts serve the OEM and power distribution markets. WL Power Circuit Breakers It’s the Circuit Breaker that changes everything! And it’s armed with a full array of competitive advantages: ▪ Reliable – increased operations and better than 1% metering accuracy ▪ Compact – smallest switchgear footprint in the industry ▪ Easy to Use – straightforward catalog numbers & selection tools ▪ Modular – drop-in, front-mounted accessories & field changeable main contacts ▪ System Solution – Internet/Ethernet, Modbus and Profibus communications ▪ Safety – customized interlocking and unique status indicators Specifications and Applications: ▪ Standards: UL489, UL1066 and ANSI C37 ▪ Frame Ratings: 800A to 5000A ▪ Rated Nominal Voltages: 240, 480 and 600VAC ▪ Interrupting Ratings: from 50KA to 150KA un-fused and 200KA fused ▪ Assemblies: Fixed mounted, draw-out Circuit Breaker or Non-automatic Switch ▪ Applicable for all ICCB or RL Breaker applications The WL Circuit Breaker may be new to North America, but it has already been proven in the field – with two years of flawless performance in Europe. No other product on the market today offers more flexibility or greater reliability. 17/2 CE Marking A wide range of Sentron® thermal magnetic circuit breakers has been fully tested for compliance with the European community's Low Voltage Directive, and carry the CE mark, indicating their compliance with that directive. These are noted in the Speedfax with the stylized CE in watermark behind the catalog numbers. Declarations of conformity are available for these products. A point of misunderstanding lies in the area of handle operators. A handle operator alone, such as that for the Max-flex, since there is no applicable European Directive, may not carry the CE mark. The mark is affixed to the finished equipment that incorporates the handle, but not to this component device. PLC Level Auxiliary Switches A new family of gold flashed auxiliary switches for the FD through ND breakers allows sensing at very low voltage and currents for interface directly to programmable logic controllers and other electronic devices. Standard contacts, built to switch 120 Volts and higher currents can be unreliable when the sensing current is in the milliamp range, and the sensing voltage is 12 Volts or lower. These very reliable low level switches overcome that limitation. Standard switch contacts should, of course, continue to be used in standard current and voltage applications. NGG Type 125A Frame Circuit Breaker The new NGG Circuit Breaker is a compact, industrial design with true value-added features such as Global Ratings (UL/CSA/IEC/CE/NOM), flexible DIN or base mounting without the need for adapters and UL Listed for field install-able accessories. This NGG125 has a 25KAIC interrupting rating at 480VAC and features a Quick Make/Quick Break Trip-free Mechanism. All this in a 3.0W x 5.4H x 2.8D package. Please consult your sales office for availability. HID Lighting Breakers Siemens BQD and CQD circuit breakers have been tested and approved for use in switching HID lighting. One, two and three pole breakers from 15A to 50A are now approved and marked for use in these high energy lighting systems where the breakers is used to directly control the lighting in 120VAC, 240VAC, 277AC or 480/277VAC circuits. Siemens Canada Limited Industrial Controls Catalogue Molded Case Circuit Breakers Catalog Numbering System Selection/Application If used on 250A frame and above means non-interchangeable trip breaker with factory assembled frame and trip. Solid state trip and current limiting (S or C in first character) are non-interchangeable only, and the “X” is omitted. X D Trip Unit Type — Omitted – Thermal-Magnetic S — Sensitrip® Electronic Trip Sentron Series Type/Interrupting Range — Omitted – Standard Rating H — High IC Rating HH — Extra High IC Rating C — Highest IC Rating and Current Limiting Frame Identifier E — Type ED F — Type FD J — Type JD L — Type LD LM — Type LMD M N P R T — — — — — Type Type Type Type Type MD ND PD RD TD Maximum Voltage 2 — 240 Vac 4 — 480 Vac 6 — 600 Vac Number of Poles 1 2 3 9 used to indicate the max. functions for an electronic trip circuit breaker (always 3 poles) (Specific Application Type) B — Standard 40°C Breaker M — Calibrated for 50°C Application F — Frame Only T — 40°C Trip Unit Only W — 50°C Trip Unit Only S — Molded Case Switch L — Low Instantaneous Range ETI Breaker A — Standard Range ETI Breaker H — High Instantaneous Range ETI Breaker Maximum Continuous Current Rating ED Frame — 015, 020, 025, 030, 035, 040, 045, 050, 060, 070, 080, 090, 100, 110, 125 FD Frame — 070, 080, 090, 100, 110, 125, 150, 175, 200, 225, 250 JD Frame — 200, 225, 250, 300, 350, 400 LD Frame — 250, 300, 350, 400, 450, 500, 600 LMD Frame — 500, 600, 700, 800 MD Frame — 500, 600, 700, 800 ND Frame — 900, 100 (1000A), 120 (1200A) PD Frame — 120 (1200A), 140 (1400A), 160 (1600A) RD Frame — 160 (1600A), 180 (1800A), 200 (2000A) TD Frame — 2000, 2500, 3200 Suffix L — where applicable indicates a breaker shipped with line/loads lugs installed A — used with a switch to show automatic self protection Y — 400 Hertz H — 100% rated P — Load side lugs only NOTE: — Position omitted if not used. 17/4 Siemens Canada Limited Industrial Controls Catalogue Molded Case Circuit Breakers JD 400A Frame Sentron Series Selection Type JXD2-A Blue Label 240V AC, 2-Pole 250V DC Only Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) 2-Pole (3 Pole Width) Catalog List Number Price $ JXD22B200■ JXD22B225■ JXD22B250■ JXD22B300 JXD22B350■ JXD22B400 Continuous Current Rating @ 40°C 200 225 250 300 350 400 3-Pole List Price $ Catalog Number JXD23B200 JXD23B225 JXD23B250 JXD23B300 JXD23B350 JXD23B400 Type JXD6-A Blue 600V AC, 2-Pole 250V DC, 3-Pole 500V DC Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) JXD62B200■ JXD62B225■ JXD62B250■ JXD62B300 JXD62B350■ JXD62B400 200 225 250 300 350 400 Label JXD63B200 JXD63B225 JXD63B250 JXD63B300 JXD63B350 JXD63B400 Type JD6-A Blue Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Catalog List Number Price $ Frame Only Catalog Number Trip Unit Only Catalog List Number Price $ List Price $ 2-Pole 600V AC, 250V DC (3 Pole Width) 200 225 250 300 350 400 JD62B200■ JD62B225■ JD62B250■ JD62B300■ JD62B350■ JD62B400 JD62F400 JD62T200■ JD62T225■ JD62T250■ JD62T300■ JD62T350■ JD62T400 JD63F400 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400 Ordering Information Complete Breaker Unassembled with Lugs Prices of JD6, HJD6, and HHJD6 breakers include frame, trip and both line and load lugs (TA2J6500). When ordered by these catalog numbers, the customer will receive the frame, trip, and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of JXD6, HJXD6, HHJXD6, and CJD6 include frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA2J6500) installed, add suffix “L” to catalog number (add 2 times list price of lugs for each pole). 100% Rated Types JXD6 and HJXD6 breakers are available with 100% ratings. To order add suffix “H” to catalog number, and 10% to list price.■ 100% rated JD breakers require the use of 90° C Cu cable and lugs TC1J6600 or TC2J6500. 50° C Applications see page 17/70. 400Hz Applications see page 17/70. 3-Pole 600V AC, 500V DC 200 225 250 300 350 400 JD63B200 JD63B225 JD63B250 JD63B300 JD63B350 JD63B400 Lugs For 75°C Wire Interrupting Ratings Breaker Type JXD2-A JXD6-A, JD6-A HJD6-A, HJXD6-A HHJD6, HHJXD6 CJD6-A RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC Volts DC (50/60Hz) 240 065 065 100 200 200 480 — 035 065 100 150 600 — 025 035 050 100 250 30 (2-P) 30 (2-P) 30 (2-P) — — 500 — 25 (3-P) 35 (3-P) — 50 (3-P) IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 500 lcu — 065 100 200 — lcu — 30 42 65 — lcs — 033 050 100 — lcu — 040 065 100 — Cables per Lug 1, 2 2 1 TA1L6750 1 1 TC1J6600 1 TC2J6500 1, 2 Compression Lug CCL600 1 Catalog Number TA2J6500 lcs — 20 33 50 — lcs — 15 21 33 — Wire Range #3/0-500 kcmil Cu #4/0-500 kcmil Al 250-500 kcmil Al 500-750 kcmil Al 500-600 kcmil Cu #3/0-600 kcmil Cu #3/0-500 kcmil Cu List Price $ 500 kcmil Cu/Al Instantaneous Adjustment Trip Range Breaker Ampere Rating 200-300 350-400 Nominal Instantaneous Values +20% Tolerance Low 2 3 4 5 6 7 1250 2000 1960 3140 2140 3430 2320 3710 1430 2290 1610 2570 ■ Built to order. Allow 2–3 weeks for delivery. Type JXD2 and JXD6 circuit breakers are UL Listed for reverse feed applications. When wired as shown on page 17/3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. 17/26 1790 2860 +20% Tolerance High 2500 4000 See Note: A, page 17/67. type circuit breakers meet the UL criteria for “current limiting” at 240 and 480V AC. HACR rated. Note: JD frame qualified to UL489 supplement B “NAVAL.” See page 17/70 for additional information. HHJD6 Modifications page 17/70 Accessories pages 17/29 and 17/71 to 17/77 Siemens Canada Limited Industrial Controls Catalogue Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit, enclosure and standard line and load pressure wire connectors — assembled and shipped as one unit from the Siemens modification center. For service equipment or applications Selection requiring a solid neutral, neutrals must be priced and ordered separately except as noted. To order, select the appropriate prefix from the table below and place it in front of the desired non-interchangeable trip or interchangeable trip circuit breaker catalog number. For circuit breaker selection, refer to pages 6-20 thru 6-53. Note: Lead times are determined based on availability of components. Items marked with ■ or ▲ in this section may contain components that are not normally stocked. Catalog Numbering Prefix Enclosure Type E1S Type 1 Surface E1F Type 1 Flush E3R Type 3R Example: Catalog number E1SJD63B400 consists of: (1) (1) (1) (6) E12 Type 12 E4X Type 4X Stainless Steel JD63F400 frame JD63T400 trip unit J6N1 enclosure TA2J6500 wire connectors Selection And Pricing By Enclosure Type Circuit Breaker Breaker Frame QJ2 QJH2 ED4 ED6 Type 3R Neutrals Type 12 Type 4, 4X 2 60-225 617.00 800.00 NA NA 3 60-225 1268.00 1490.00 NA NA 2 60-225 1177.00 1360.00 NA NA 3 60-225 1689.00 1911.00 NA NA 2 60-225 1410.00 1593.00 NA NA 3 60-225 2085.00 2307.00 NA NA 2 2 15-60 70-100 416.00 590.00 664.00 838.00 516.00 690.00 2980.00 3154.00 3 3 15-60 70-100 550.00 726.00 798.00 974.00 650.00 826.00 3114.00 3290.00 2 2 2 15-60 70-100 110-125 638.00 795.00 1578.00 886.00 1043.00 2010.00 738.00 895.00 1748.00 3202.00 3359.00 4026.00 3 3 3 15-60 70-100 110-125 793.00 908.00 1776.00 1041.00 1156.00 2208.00 893.00 1008.00 1946.00 3357.00 3472.00 4224.00 2 2 15-60 70-100 726.00 878.00 974.00 1126.00 826.00 978.00 3290.00 3442.00 3 3 3 15-60 70-100 110-125 883.00 1069.00 2041.00 1131.00 1317.00 2473.00 983.00 1169.00 2211.00 3447.00 3633.00 4489.00 Discount Schedule F Lug Catalog Number (included) Catalog Number List Price $ TA1Q300 TA1Q300 Included with enclosure TA1Q300 Enclosed Circuit Breakers ED2 Ampere Rating Type 1 Surface or Flush 5 QJ2-H Number of Poles List Price $ — Complete Assembly 15-25A SA1E025 30-60A Line LN1E100 Load LD1E060 70-100 LN1E100 Catalog Number W53045 included with enclosure 110-125A TA1E6125 Siemens Electrical Distribution Products Catalog 2006 SPEEDFAX 5-3