* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download DC Network Analyzer
Power over Ethernet wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electric power system wikipedia , lookup
Opto-isolator wikipedia , lookup
Electrification wikipedia , lookup
Stray voltage wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Transmission line loudspeaker wikipedia , lookup
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power engineering wikipedia , lookup
Zobel network wikipedia , lookup
Mains electricity wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Fault tolerance wikipedia , lookup
Two-port network wikipedia , lookup
Three-phase electric power wikipedia , lookup
Alternating current wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
DC NETWORK ANALYZER MD E INTRODUCTION : The DC network analyzer is design to analyze the fault currents in power system. The symmetrical and unsymmetrical fault analysis can be done with help of analyzer. The unit comprises with variable power supply sources, variable resistance, Milliammeter and ohmmeter. The unit is design with number of sections in power system. The sections are considered for general case. The unit will have two sections of alternators, two sections of sending end transformers with busbars, four sections of transmission lines, four sections of receiving end transformers with busbars and four load sections. The fault impedance diagram can be prepared on per phase basis for symmetrical faults and currents are calculated. The same can be analyzed with dc network analyzer panel. For the unsymmetrical faults, the sequence reactance diagrams are prepared and the positive, negative & zero sequence reactance diagrams are connected in series or parallel according to type of fault for fault current analysis. The DC network analyzer will give the simulated fault current in agnitude but the exact phase can not be found. The assumption is made that fault resistance is very small than the reactance. (i.e. Rf <<< XF) So the fault current is pure reactive & logging behind the phase voltage by 90. For analyzing currents with its phase and magnitude the AC network analyzer is required. The DC network analyzer is simple to operate, easy to understand and full proof with protections. The power supply units in analyzer can be independently used for other applications also. The power supply manual is enclosed separately. The DC network analyzer unit is totally enclosed, free standing, dustproof. The unit powder coated and screen printed for different section parameters. MD E DC NETWORK ANALYZER ELECTRICAL SPECIFICATIONS : Input Auxiliary Supply : 230V +/- 10%, 1-Ph, 50Hz AC Supply. Base quantities (To be assumed for fault analysis) : a) Base KVA = 20 MVA. b) Base KV = 200 KV. c) Base independence = 2000 ohms. No. of sections for analyzer Short circuit protection. : : Digital Ohmmeter. a) Alternators. = 2 nos. b) Busbars & T/F's at SE = 2 nos. c) Transmission lines. = 4 nos. d) Busbars & T/F at RE = 4 nos. e) Load parameters. = 4 nos. With HRC fuses at input, control & output. 0-2K/20K, 3½ digit, 96X96 sq.mm. M D Electricals make D.C. voltage source. : 0-30 V/ 0-1A Dual DC power supply with CV/CC mode operation, MDE make. Variable resistances. : Digital Millimeters 0-2000 ohms, 10 Turn pot. => 16 nos. 0-200 mA, 3½ digit, 68x30 sq.mm => 8 nos. Digital Voltmeters : 0-20 volt , 3½ digit, 68x30 sq.mm. => 01 no Luminous Main Switch : Selector switch with NO elements with bulb & series resistance assembly Fuses : NSH20/2A, EE make Terminals : BTI15 terminal pairs for each component MECHANICAL DIAMENSIONS: SIZE : 800 x 400 x 1000 mm ( L x D x H ) WEIGHT : 120 Kg. For more details please contact : M D ELECTRICALS Office/works: 50/16,VadgaonNarhe Road, Narhe, Pune 411 041. Tel. : 91-020-24393922 Tel fax. : 91- 020-2439 3407. Email. : [email protected] Wesbite : mdelectricals.com Subjected to change without notice