Transcript
COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT IEC 62040-1, 1st ED (2008) TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING R=Required by Lab S=May be subcontracted - ‘RB’ = ‘Required Basic’; test and measurement equipment required for all equipment. - ‘RT’ = ‘Required for telecom’; in addition to ‘RB’, required for testing apparatus with connection(s) to a telecommunication network. Clause 62040-1 1.2 Reference Clause 60950-1 1.1.2 4.4 - 4.6 4.7.16 1.6.2 1.7.11 4.7.2 4.7.13 4.7.20 5.1.3 2012-01-11 modified 5.1 2.1.1.5 Measurement/testing Reference clause IEC 60950-1 in () Ingress of water, Annex H Reference Loads Power interfaces (Input current) Durability of markings (Durability) Power Rating Testing / measuring equipment / material needed IP foreign object and water test apparatus per IEC 60529. Simulated/artificial loads, Annex L. Amp-meter suitable for the current and waveform Petroleum spirit (aliphatic solvent hexane or reagent grade hexane)/water/piece of cloth Amp-Voltage meter for input and output, power meter, power factor meter Measuring instruments of Annex D High leakage current (Touch current and protective conductor current) Battery Variable resistive load Protection for UPS intended to be used in restricted access areas (Energy Hazard) IEC 62040-1, 1st ED (2008) Subcontracting S Note: “As these simulated loads may be very different, they need not to be available in the CBTL but may be supplied by the manufacturer” RB RB RB RB RB COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 62040-1 5.1.1 Reference Clause 60950-1 2.1.1.7 5.1.3 2.1.1.1 5.2.3 2.4.2 5.1.4 5.3.2 2.10 5.3.2 8.2 2.10.3.9 2.10.4 2.10.9 & 2.10.10 & 2.10.11 (and 2.10.8.2) 2.10.8.4 2.10.7 3.1.5, 3.1.9 and 4.2.2 5.2 2012-01-11 modified Measurement/testing Reference clause IEC 60950-1 in () Protection for UPS intended to be used in operator access areas (Plug discharge) Protection for UPS intended to be used in restricted access areas (Access to energized parts) Limited current circuits (Limited current circuits, limit values) Backfeed protection Protective earthing (Creepage distance/clearance/distance through insulation (determination of requirements; working voltage measurements)) (Creepagedistance/clearance/distance through insulation (measurements)) Testing / measuring equipment / material needed Subcontracting Measuring instrument with input impedance 100M M in parallel with an input capacitance of 25pF or less. Test finger (joint /rigid 30N, fig. 2A) RB Test pin (fig. 2B/ Ø4mm/Ø3mm/15 mm long) Test probe (Fig. 2C, Ø12mm/80mm) Resistor 2 000 10%, Capacitance measuring device RB RB RB Oscilloscope RB RB Dial gauge Micrometer Pins etc. With different diameters Microscope Test-generator; reference 2 of table N.1 Test equipment for tracking index per IEC 60112 Full draught oven ( 2ºC) Cooling facility (0º C) RB RB RB RB S S S (Abrasion resistance test) (Enclosed and sealed parts) (10 N steady force test) Scratch test device with steel pin See 2.10.9 & 2.10.10 Suitable tool for applying steady force of 10 N +/- 1N S S RB Protective earthing Electric strength (Electric strength) Test equipment with the relevant voltage and tripping current. RB (Measurement of transient levels) (Creepage distances) (Thermal cycling and thermal ageing) IEC 62040-1, 1st ED (2008) COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 62040-1 Reference Clause 60950-1 7.3 Measurement/testing Reference clause IEC 60950-1 in () Mechanical strength (Steady force test 30 N) 4.2.3 Test tool 250N 10N with a circular plan surface 30mm. RB 4.2.5 Mechanical strength (Impact test) 50mm/500g 25g steel ball RB 4.2.6 Mechanical strength (Drop test) RB 4.2.7 Mechanical strength (Stress relief) 4.2.8 4.2.10 Mechanical strength (Cathode ray tube) Mechanical strength (Wall or ceiling mounted equipment) Protective bonding (Resistance of earthing conductors) General provisions for connection to power (AC Power Supply Cords) General provisions for connection to power (Cord anchorage and strain relief) General provisions for connection to power (Cord guards) Hard wood 13mm on 18mm ± 2mm plywood, two layers. Measuring equipment according tp IEC 60695-10-3 or Oven 70K over normal temp. Test equipment acc. IEC 60065 Several weights High current source with a voltage <12V RB 6.2.1 3.2.5.1 3.2.6 3.2.8 7.1 2012-01-11 modified RB Test finger (rigid 30N 3N, fig. 2A) Mechanical strength (Steady state force, 250 N) 2.6.3.4 7.4.1 Subcontracting 4.2.4 5.3.3 7.2 Testing / measuring equipment / material needed Test equipment according IEC 60227 RB S RB S Appropriate weights RB See 3.2.6 RB Force 250N/ Test tool 800N with a flat surface 12,5cm by 20cm Test probe (Fig. 2C, 12mm/80mm) RB RT 6.2.1 Enclosure (Separation requirements) 4.1. Stability (Stability) Inclined plane 10 RB Construction details Force 15N/20N/30N/50N RB IEC 62040-1, 1st ED (2008) COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 62040-1 Reference Clause 60950-1 4.3.2 7.4.1 4.4 7.4.1; 7.7 4.5 Measurement/testing Reference clause IEC 60950-1 in () Construction details (Protection against hazardous moving parts) Construction details Temperature rise (Thermal requirements) (Voltage supply) (Voltage) (Current) 4.5.5 4.7.3 7.5 9 2012-01-11 modified Openings in the top Equipment movement Temperature rise (Resistance to abnormal heat) (Materials, Tests see Annex A) Resistance to fire 4.7.3.6 2.3.1 Subcontracting (Handles and manual controls) Temperature (rise) 7.4.2 7.4.4 7.7 Testing / measuring equipment / material needed Materials used in high-voltage components Connection to telecommunication networks IEC 62040-1, 1st ED (2008) Test finger (joint /rigid 30N, fig. 2A) RB RB Single phase voltage supply systems/variability/adequacy Three phase voltage supply systems Temperature recorder (multi-channel) Thermocouples Winding resistance (normally > 1,0 2-wire, 4-wire <1,0 ). Voltmeters (ac/dc) High voltage meter (probe) Currents (ac/dc) Loads (resistive) calliper Scale (25kg), force meter Ball pressure test apparatus according to IEC60695-10-2, Oven at least 125ºC V-1, V-2, HF-2, 5V Bunsen burner (9,5 0,5 mm) Gas for burner (~37 MJ/m3) Oven for preconditioning Test of Annex A or test of 14.4 of IEC 60065 or needle flame test according to IEC 60695-2-2 RB S RB RB RB RB RB RB RB RB RB RB RB RB RB RB RB RT COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 62040-1 Reference Clause 60950-1 Measurement/testing Reference clause IEC 60950-1 in () Annex M.4 Annex I.2 Annex D Annex I.3 Annex D Annex I.4 - (Limits of TNV circuits) Connection to telecommunication networks (Connection of TNV circuits to other circuits) Connection to telecommunication networks (Test for operating voltages generated externally) Ventilation of battery compartments Test for pluggable UPS (Limited current circuits, limit values) Test for permanently connected UPS (Limited current circuits, limit values) Load-induced change of reference potential Annex I.5 - Solid state backfeed protection 2.3.4 2.3.5 Testing / measuring equipment / material needed Subcontracting Non-inductive Resistor 5000 RT RT hydrogen gas concentration measurement S RB Measuring of Annex D, Timer RB 22 nF capacitors (C ) and resistive loads Note: “As these simulated loads may be very different, they need not to be available in the CBTL but may be supplied by the manufacturer” Test generators for transient O/V, voltage variations, S EM susceptibility, ESD as outlined in 7.1 through 7.5 of IEC 62040-2. Note: The presence of equipment alone does not indicate a satisfactory situation. Assessors must evaluate the equipment design, calibration, uncertainty and documentation to ensure compliance with the directions of the standard. The requirements of ISO/IEC 17025 regarding validation are applicable, as the tests of this standard are not standardised tests. IEC 62040-1 equipment has been sub-grouped into: 1)Equipment with connection(s) to a telecommunication network (called RT) Other apparatus with none of the features mentioned under 1) will at least need RB 2012-01-11 modified IEC 62040-1, 1st ED (2008)