Download Non-Ideal Inductors

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ohm's law wikipedia , lookup

Memristor wikipedia , lookup

Electrical ballast wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Coilgun wikipedia , lookup

Transformer wikipedia , lookup

Loading coil wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Alternating current wikipedia , lookup

Buck converter wikipedia , lookup

Multimeter wikipedia , lookup

Skin effect wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Magnetic-core memory wikipedia , lookup

Transcript
Non-Ideal Inductors
S. Durkin
Coil Resistance:
Real Inductors contain large lengths of wire wrapped around a central core, which can
be hollow (air core) or magnetic (magnetic core). This length of wire can have sizeable
resistance. Thus one must treat your inductor in the LRC circuit as an ideal inductor in
series with a resistance RL. You can measure the ideal inductance using the inductance
meter. You can measure the resistance RL using your fluke meter. This resistance must be
taken into account when calculating Q!
Air core inductors unfortunately are hard to purchase, typically have low inductance,
and are expensive. In lab we use inexpensive ferrite core inductors. You can test with an
external magnet if you are unsure whether your inductor is air core or not. The
introduction of a ferrite core, causes other problems listed below.
Eddy Currents/Hysteresis
Eddy currents and hysteresis can cause local heating, and thus act like an extra source
of resistance. Both effects increase with frequency. Thus for ferrite core inductors one
can expect an additional effective resistance in series with the coil resistance. This
effective resistance will act to lower your measured Q.
Saturation
At high currents the ferrite core can saturate (all domains aligned), thus decreasing
the inductance. This will increase your resonance frequency. You can test for this by
tuning your LRC circuit to resonance, and varying the input voltage amplitude. If the
resonance point shifts you are see saturation. If you see saturation working at lower input
voltages should give you close to the inductance measured by the fluke meter. Hysteresis
and saturation can also significantly distort the voltage across the inductor, yielding a
very non-sinusoidal result.