* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Alpha and Beta can be expressed in terms of a Damping Coefficient
Electric machine wikipedia , lookup
Rotary encoder wikipedia , lookup
Stray voltage wikipedia , lookup
Induction motor wikipedia , lookup
Electrical ballast wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Control system wikipedia , lookup
Current source wikipedia , lookup
Surge protector wikipedia , lookup
Power MOSFET wikipedia , lookup
Power engineering wikipedia , lookup
Distribution management system wikipedia , lookup
Power inverter wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Voltage optimisation wikipedia , lookup
Stepper motor wikipedia , lookup
Three-phase electric power wikipedia , lookup
Mains electricity wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
Digital Motion Control System Design - From the Ground Up Introduction • Break Motion Control Design into three parts – Digital Hardware Design – Power Hardware Design – Software Design • Introduce D3 Engineering’s Motor Control Development Kit Control Hardware • Choose Feedback Method • Choose Communications interface • Isolation requirements – Isolation between control and power electronics – Isolation between control electronics and outside world • • • • Digital I/O Analog I/O Pulse Width Modulation (PWM) Putting it all together Feedback • Incremental or Absolute • Resolution requirements • Environmental considerations Incremental Optical Encoder • • • Code disk with optical transmitter and receiver on either side Outputs two quadrature signals, A and B, and an index pulse Multiple options for output configuration – Open collector – Differential Line Driver – 5V-24V • • • • Each edge is counted giving 4x resolution Commutation tracks also available Available in high resolution (>100K counts per rev) Easy to interface, no analog hardware Incremental Optical Encoder • Standard products not typically good for harsh environments • No absolute position data Resolver • A rotating transformer • Input – AC excitation • Output – Sin and Cos of rotor angle modulated at excitation frequency Resolver • Typically considered rugged, good for harsh environments • Absolute within 1 revolution Resolver • Requires Resolver to Digital Converter (RDC) – Separate ASIC – Implement in DSP • Requires careful analog design • Resolution is a function of RDC Absolute Encoder • Serial or Parallel interface – Typically up to 17-bit single turn resolution • Absolute over single or multiple revolutions – 12-bit multi-turn resolution typical • Available user memory • Currently popular among commercial industrial servo drives Communications • CAN – Host Controller – External Sensors – DeviceNet • LIN – Host Controller – Automotive • RS-232 – Host PC – Display/Keypad • RS-485 – Multi-drop • SPI – Interprocessor – Absolute Encoder – EEPROM • I 2C – EEPROM – Display Digital I/O • Allow drive to interact with the outside world – – – – – Sensors Limit Switches Relays Enable Signal Fault Output Analog I/O • To/From the outside world – Velocity command – Torque command – External sensor • Potentiometer • LVDT – Monitor Output (DAC) – +/-10V – 4-20mA • Within the drive – Current sensing – Voltage sensing – Temperature sensing Pulse Width Modulation (PWM) • Modulate the duty cycle of a square wave to generate an output waveform – Generate the switching pattern of power transistors in a motor drive – Regulate Current flow – Generate AC motor voltages High Performance DSP • TMS320C28x Family • Up to 150MHz • Internal Flash Memory (Up to 512K) • Internal RAM (Up to 68K) • Floating Point Unit (300 MFLOPS) • Includes peripherals needed for motor control High Performance DSP • ADC – 12-bit, 12.5 MSPS – – – – Current Sensing Voltage Sensing Resolver Analog Inputs High Performance DSP • Enhanced Quadrature Encoder Pulse Module (eQEP) – Implement incremental encoder feedback – Use as Pulse/Direction input High Performance DSP • Enhanced PWM Module (ePWM) – Control switching of the power hardware – Digital to Analog Conversion (DAC) • Generate resolver excitation signal High Performance DSP • Communications Peripherals – – – – SPI SCI I2C CAN Power Hardware Design • • • • • DC Bus Inverter Control power High-side supplies Current Sense DC Bus • The DC Bus supplies power to the motor • Supply can be from a DC source or rectified AC • An AC source is typically single or three-phase DC Bus – Single Phase AC Input • Rectifier • Inrush current limiting • DC Bus capacitors • Voltage doubler DC Bus – Rectifier • Single-phase for up to 1-2KW • Higher power requires three-phase input and three-phase rectifier DC Bus – Inrush Current Limiter • During a “cold start” DC Bus capacitors initially look like a short circuit • Need to limit inrush current to prevent damage to rectifier and DC Bus capacitors. DC Bus – Inrush Current Limiter • Classic approach is to use a resistor in series with the DC Bus • Once capacitors are charged resistor is shunted by a relay • Resistor doesn’t need to carry full DC Bus current DC Bus – Inrush Current Limiter • Resistor and Relay inrush current limiter is a common failure point in motor drives • Relay can’t be used in some hazardous environments DC Bus Inrush Current Limiter • Alternative – Negative Temperature Coefficient Thermistor (NTC) • Starts out at high resistance when cold, resistance decreases to a few milliohms as current flows and device heats up • No need for shunt relay • Limited range of continuous current ratings • May not work when ambient temperature requirements are high DC Bus – Inrush Current Limiter • Replace relay with a solid state device • OK for hazardous environments • Requires more hardware to turn the device ON DC Bus – Inrush Current Limiter • Need to extensively test whatever method you choose – At max ambient temperature – At max load – Power cycle testing DC Bus – Voltage Doubler • Ability to obtain 300V DC Bus from 110VAC source • Each capacitor charges separately on opposing half cycles of the AC input • Rectified DC Bus is equal to 2 times the peak AC input • Output power must stay the same so max continuous current is cut in half Inverter • A three-phase bridge made of IGBTs or MOSFETs that switch power to the motor • Usually implemented as 6 discrete devices or 1 Intelligent Power Module Inverter - IPM • Intelligent Power Modules are typically designed to directly interface to a DSP or microcontroller • Integrated high and low-side gate drive • Integrated UVLO • Integrated Over-current/Short-circuit protection • Limited packaging options • Limited current/voltage ratings Inverter – Discrete Implementation • More packaging flexability • Greater variety in voltage/current ratings • Need to design external gate drive, UVLO, and over-current detection Control Power Supply • Minimum of two supplies – Gate Drive supply – Logic supply • Regulated from DC Bus or separate control power input • Isolated or Non-isolated Non-isolated Buck Converter • Usually used in lowcost designs • Regulate control supplies directly from DC Bus • Digital supply regulated from Gate Drive supply with LDO • Isolated Flyback Converter Powered from DC bus or separate control power input • Generate multiple voltages High-Side Supplies • Why do we need separate high-side supplies? • Boot-strap supplies • Separate floating supplies Why High-Side Supplies • IGBT needs VGE > VGEsat to turn completely on • MOSFET needs VGS > VGSsat to turn completely on Why High-Side Supplies • Emitter (or Source) of High-Side device “floats” with motor phase Bootstrap Supplies • High-Side Gate Drive powered by bootstrap capacitor • Capacitor charged through diode when low-side device is ON Bootstrap Supplies • Can’t run at 100% PWM duty cycle indefinitely • Need some low-side ON-time to charge bootstrap capacitor • Inexpensive Bootstrap Supplies • Some considerations for sizing bootstrap components – Minimum Vboot voltage – Gate driver quiescent current – IGBT Gate charge – High-side On-time • Separate Floating Supplies Add three additional windings to flyback transformer • No more limitations on duty cycle • Bigger transformer • More expensive Current Sense • Shunt resistor – Current is measured as voltage drop across a current sense resistor • Hall-effect device – The magnetic field of a current carrying wire is sensed and converted to a voltage Shunt Resistor • Place between low-side power device and DC Bus N – Current sense when lowside is ON and high-side is off – Can’t achieve 100% duty cycle, need some OFF time to sense current – Because of power loss, becomes less practical as current gets higher Shunt Resistor • Place shunt resistor in motor phase – Need isolated measurement circuitry – Able to sense currents at 100% duty cycle Hall-effect Current Sensor DC Bus P Hall Effect Current Sensor U V W DC Bus N Hall Effect Current Sensor Motor • Inherently and isolated sensor • Usually able to be powered from logic supply • Less power dissipation, able to sense higher currents • Typically more expensive than shunt measurement • Available in fixed sensitivity ranges Motor Control Hardware/Software Interface d p (t ) r (nT ) + + eˆ(nT ) D(z) u (nT ) D/A yˆ (nT ) A/D Sensor d s (t ) u (t ) G(z) y (t ) • Information about the system is acquired through the ADC • The system is controlled by the PWMs • Both information exchanges happen through peripherals in the 28x DSPs • Other feedback is acquired through logical interfaces like GPIO, QEP, Capture and Comm. peripherals ADC Sampling • • • • • For a quality motion control algorithm, accurate current information is required Noise can be reduced by synching current sampling with PWM frequency Some phase delay between PWM switching edge and ADC sample should be applied to allow for signal to settle If sampling more than one phase of a motor simultaneous Sampling should be used to acquire signals at same point in time. Proper capacitance on ADC inputs should be used to allow for good charge transfer. A good rule is 200x the ADC capacitance ADC Sampling for FOC • • • • • Current can be sampled in leg of switch or inline with motor phase If sampled in leg of switch a time when all Switches are switched to ground must be allowed Leg sampling will not allow for 100% duty cycle operation Depending on worst case slew rate as much as 10% duty cycle might be lost Sampling in line with phase requires either a floating reference point or the use of hall or other non intrusive current sensors. PWM • Sampling should be synched to PWM frequency • System torque/current loop should also run at PWM frequency and should be able to be processed/executed in the same period • The main control loop should also run at this frequency or some even multiple of this frequency to keep system synchronous. FOC Controls Diagram Sample Custom Designed Blocks Control Logic (State Table) Profile Generator Direct Current PID Vd Velocity PID Vq Inverse Park Transform 3 Phase BLDC Motor Space Vector PWM Generator Quadrature Current PID AD Voltage Supervisory TI DMC Library Blocks Velocity Vd Park Transform Vq Id Iq Current Phase A Clark Transform Current Phase B Rotor Position PWM Velocity Calculator from Estimated Position Rotor Position Estimator Vds Vqs Voltage Phase Voltage Reconstruction AD Motor Bus Voltage IQ Math Library Near Floating Point Precision with Fixed Point Performance • TI provided IQ math Library is just one tool available to TI customers. • Library is available in both Mathworks and as a C library. • TI, its customers and 3rd Parties like D3 have worked together to optimize available tools and algorithms like the IQ math Library. More info available at www.ti.com/iqmath Digital Filtering For Feedback • • • • • Observer Tracking filter Performance adjusted by changing Alpha and Beta Possible application as a resolver angle filter Can be related to basic 2nd order Transfer function (TF) Alpha and Beta can be expressed in terms of a Damping Coefficient and a Natural Frequency A Alpha 1 Input B 1 Derivative of Output Beta Unit Delay1 1 z Unit Delay 1 z 2 Output Communications • • • • • CAN SCI I2C SPI I/O Modular Design With Simulink® Mathworks and TI Tools Motor Control Development Kit • A platform for D3 and our customers to begin development of motor control applications • Include many common features of a motor control application • Allow expansion and flexibility • A two board design, control board and power board – Allows mix and match of control and power boards – Allows control board to be a stand-alone product Motor Development Kit • Contol board based on TMS320F2806 DSP • Isolated from power board and outside world • 5V input from power board or wall pack • All peripherals come to headers for expansion Motor Development Kit • Feedback – Encoder – Resolver • Communications – RS-232 – USB – CAN • Digital I/O – Inputs (4) – Outputs (3) • Power Board Interface – – – – – – PWM (6) Motor Phase Current Sense (3) DC Bus Current Sense DC Bus Voltage Sense Power Board Fault signal 5V Motor Development Kit • Power board designed to accept Smart Power Modules from 3A to 30A • DC Bus rectified from 110V or 220V AC • Voltage Doubler • Separate control power and DC bus • Isolated from control board • Sense three phase currents and DC bus current through shunt resistors • Bootstrap high-side supplies • DC Bus voltage sense Motor Development Kit • Come see the MDK in action at our booth