Comparative Biochemistry and Physiology Part A 124 (1999) 447 – 460 www.elsevier.com/locate/cbpa Review Understanding autonomic sympathovagal balance from short-term heart rate variations. Are we analyzing noise? Jordi Altimiras * Department of Zoophysiology, Institute of Biological Sciences, Uni6ersity of Aarhus, Building 131, Uni6ersitetsparken, DK-8000 Aarhus C, Denmark Received 21 September 1998; received in revised form 15 March 1999; accepted 30 March 1999 Abstract Heart rate variations reflect the output of the complex control of the heart mediated by the autonomic nervous system. Because of that, they also encode different types of information, namely the efferent outflow of reflex mechanisms involved in the beat-to-beat control of cardiac function, the efferent activity of neurohumoral elements involved in the control of other cardiovascular parameters and random noise resulting from the hysteresis of the different controllers. The degree to which power spectrum estimation methods will uncover the periodic component of heart rate variations is in direct relation with the status of the system under study. Although the utility of spectral methods is now established in mammalian research, very little is known on the utility of these techniques in non-mammalian cardiovascular research. This review covers this space by discussing the physiological significance of heart rate variations in non-mammalian vertebrates. A detailed account of the different steps of the technique, its limitations and the ways to overcome these problems are also presented. These are: the recording of the cardiac event signal, the detection and digital processing methods, the satisfaction of stationarity conditions, the problem of spectral leakage and the different methods to estimate the power spectrum. © 1999 Elsevier Science Inc. All rights reserved. Keywords: Spectral analysis; Heart rate; Heart rate variability; Respiratory sinus arhythmia; Sympathovagal balance; Power spectrum; Autonomic nervous system; Cardiac function 1. Introduction The study of cardiac autonomic regulation using reductionistic methods, i.e. isolating surgically or pharmacologically the different autonomic effectors implicated in cardiac regulation, has provided a consistent body of knowledge of the magnitude and the dynamic time course of the response of the cardiovascular system after different types of perturbations. However, as a recognized limitation of this experimental approach, the original system under study needs to be disrupted. Instead of describing ‘the’ original system, we are studying ‘a’ perturbed system that may or may not * Present address: Department of Zoophysiology, Zoological Institute, University of Göteborg, Medicinaregatan 18, Box 463, S-40530 Göteborg, Sweden. Tel.: +46-317-733-693; fax: +46-317-733-807. E-mail address: [email protected] (J. Altimiras) display the features aimed to understand. Thus, there is a need to combine these reductionistic studies with integrative approaches aiming to characterize the complexities of autonomic cardiac regulation without the need to experimentally isolate the different components. Spectral analysis is instrumental in fulfilling such goal. Under the denomination ‘spectral analysis’ we include a large set of mathematical tools that permit the characterization of signals according to its frequency content. As a crude comparison, spectral analysis is to time signals what a prism is to light, a tool to unravel the different spectral components (colors) hidden under a white light. Over the last two decades, it has been consistently demonstrated that the beat-to-beat variations of heart rate contain information about the activity of the autonomic effectors controlling cardiac output [63]. The interest of spectral analysis is focused on the quantita- 1095-6433/99/$ - see front matter © 1999 Elsevier Science Inc. All rights reserved. PII: S 1 0 9 5 - 6 4 3 3 ( 9 9 ) 0 0 1 3 7 - 3 448 J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 tive separation of physiologically relevant mechanisms from a complex output, the beat-to-beat variations in instantaneous heart rate or, what has been more appropriately called the heart rate variability signal (HRVS). Irrespective of the internal intricacies of the system, which is treated like a black-box, the resulting autonomic drive results from the combination of the parasympathetic and the sympathetic cardiac autonomic outflow, together with a third component that encompasses other physiological humoral mechanisms and the intrinsic noise of the control circuitry. In virtue of their different time constants [20], these mechanisms can be separated as will be discussed in Section 2.4. Comparative physiologists have made little use of spectral analysis, despite the interest to study cardiac regulation in a large set of species with widely diversified central flow patterns and gas exchange organs and with the capacity to adapt and survive in constantly changing environments. The study of non-mammalian vertebrates can be viewed as an evolutionary showroom of relict and modern control mechanisms, obvious predecessors and, at the same time, actual survivors in a process of distilled missed and successful trials. In this framework, spectral analysis techniques can contribute to a deeper understanding of the intricacies of autonomic cardiac control through the vertebrate phylogeny. However, in order to apply these spectral analysis techniques in a comparative context, it is important to identify and understand the shortcomings and the requirements of the technique itself. While this is usually irrelevant in mammalian studies, it acquires an important dimension in comparative research because of the lack of standardized procedures. If the HRVS is contaminated by artifacts arising from improper recording, detection or processing, the low signal-to-noise ratio will be compromised and the results will be difficult to interpret. This review intends to discuss critically the detailed applicability of one specific type of spectral analysis to HRVS, namely the power spectrum estimation methods. To do this, the paper will be divided in several sections. First, the physiological significance of heart rate variations will be discussed to emphasize that heart rate variations are intrinsically linked to different mechanisms of cardiac control. In Section 3 the common methodology employed in mammalian studies will be reported, together with a brief account of alternative methods. In Section 4, the critical steps to establish an appropriate analytical protocol will be presented and discussed with an emphasis on its application in non-mammalian vertebrates. Finally, the last section will be used as a concluding corollary of the review. 2. Heart rate variations have a physiological significance ‘‘Physiologists, both by tradition and design, typically express their data as mean values with some additional indicator of variance. While this conveys information on the central tendency in that population of animals, it de-emphasizes any variation in the data’’ [23]. Referred by Bennett as ‘the tyranny of the golden mean’ [19], this trend was originally applied to interindividual differences in a given population. It also applies to a single individual if a physiological variable recorded over a given period of time is reduced to its mean value. In this case, the ‘golden mean’ would give a statistically acceptable estimation of the variable, neglecting at the same time its intrinsic variation around the mean value. But these variations have a physiological significance because changes in heart rate (HR) are coupled to changes in cardiac output. The changes in heart rate originate as part of the homeostatic response to a perturbation or in response to cyclic oscillations of cardiovascular parameters. The result is the modification of the inputs to the centers responsible for cardiovascular control, maintaining cardiac function in a state of homeodynamic balance via, among other systems, a constant modulation of heart rate. In the following sections I will stress the significance of heart rate variations and the possibility to obtain significant information to understand the cardiovascular control by the application of several specialized tools. This has only been studied in mammals and what follows is a general revision of our present knowledge. 2.1. Variations in heart rate distribute o6er a wide frequency range In a broad sense, any change in heart rate qualifies as heart rate variability (HRV). Since the origin of these changes can differ widely, it is relevant to categorize them. Six types have been proposed [53]. From slowest to fastest (Fig. 1): 2.1.1. Age related changes During embryonic life there is a common increase in heart rate associated with the functional maturation of the cardiac muscle [69]. After birth, heart rate tends to decrease with age due to structural and hemodynamic changes [65]. 2.1.2. Seasonal changes Hibernating or aestivating species will display marked seasonal differences in heart rate throughout the year. Temperature fluctuations and changes in the hormonal profile are probably the most important causes behind such changes [52]. J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 2.1.3. Circadian or daily rhythms Guided by internal clocks. In humans they are clearly seen in 24-h electrocardiographic recordings and reflect alterations in the autonomic nervous system during the day [55]. 2.1.4. Ultradian rhythms Submultiples of the circadian rhythm with a period of 1 –3 h [32,46]. The mechanism of action is not well understood but hormonal as well as central influences have been implicated. 2.1.5. Minute changes Minute changes, associated with neurohumoral oscillations in the epinephrine – norepinephrine and/or angiotensin levels in the circulating blood [53]. 2.1.6. Beat-to-beat changes Beat-to-beat changes, which will be referred as short heart rate variability (SHRV). Mediated by the autonomic nervous system (ANS), reflect the activity of the reflex mechanisms involved in cardiovascular control. This paper will be exclusively committed to discuss the highest frequency type of variations, i.e. heart rate changes occurring in a beat-to-beat basis with a time response roughly inferior to a minute and mediated by the ANS. 2.2. Short term heart rate 6ariations are associated with the inner6ation of the cardiac pacemaker SHRV arise mainly from the innervation of the sinoatrial node, as has been shown in numerous species. Human patients with a transplanted heart display a reduction up to 90% in SHRV [60]. Sympathectomized rats show an increased HRV [26]. In fish, bilateral vagotomy reduced SHRV drastically [8]. Blockade of vagal activity with atropine is responsible for a large decrease in total HRV in all the species tested, from fish to humans [13,30,37]. 449 2.3. Parasympathetic and sympathetic responses ha6e a different time constant The spectral range of adrenergic and cholinergic effectors differ due to several factors: 1. Mechanism of elimination of the neurotransmitters in the synaptic cleft. While norepinephrine is mainly reuptaken in the sympathetic nerve terminals or washed out in the coronary circulation, acetylcholine is enzymatically hydrolyzed in the same nerve terminals [44]. 2. Post-synaptic effects. b-adrenoceptors are coupled to a cAMP pathway, while muscarinic receptors are directly coupled to specific sarcolemmal potassium channels that trigger membrane hyperpolarization within 100 ms of the initiation of vagal stimulation. As a result, cholinergic dependent responses are faster than b-adrenenergic dependent responses and this sets the basis for the analysis of SHRV using spectral analysis. 2.4. The components of the power spectrum of the HRV are associated with different mechanisms of cardio6ascular regulation The power spectrum of HRV in mammals usually reveals three spectral components. Taking the pioneering study of Akselrod and co-workers [5] in anesthetised dogs as an example (Fig. 2), these components are the following: 1. A high frequency component (HF) at 0.4 Hz 2. A low frequency component (LF) centered at 0.12 Hz 3. A very low frequency component (VLF) centered at 0.05 Hz The HF component is caused by an inhibition of the vagal tone during inspiration. This inspiratory inhibition is evoked centrally on the cardiovascular center and explains why heart rate fluctuates with the respira- Fig. 1. Time – frequency scale of the different types of heart rate variations. Data for the different panels was obtained from the following sources: panel 1 [12]; panel 2 [33]; panel 3 [55] and panel 4 [46]. 1 - Age-related; 2 - Seasonal; 3 - Circadian; 4 - Ultradian; 5 - Minute; 6 - Beat to beat. 450 J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 Fig. 2. Original figures from the pioneering work of Akselrod and co-workers reporting the power spectrum of HRV from anaesthetized dogs [5]. With permission from the publisher. tory frequency. In addition, peripheral reflexes arising from thoracic stretch receptors also contribute to this so-called respiratory sinus arrhythmia (RSA). RSA is clearly abolished by atropine or vagotomy and the power of the HF component has been used as an index of the vagal drive. The LF component of HRV is usually characterized by an oscillatory pattern with a period of 10 s. This rhythm originates from self-oscillation in the vasomotor part of the baroreflex loop as a result of negative feedback [47] and it is commonly associated with synchronous fluctuations in blood pressure, the so-called Mayer waves. Muscarinic and b-adrenoceptor antagonists are known to change the area of the LF peak. In the dog, the LF component appear to be mainly mediated by the parasympathetic nervous system [4], while in rats the sympathetic influence accounts for 80% of the LF area [25]. The very low frequency component (VLF) accounts for all other heart rate changes, including those associated with thermoregulation and humoral and local factors. Some of these changes might be oscillatory (when the period of oscillation is long) while others are known to be chaotic. For the identification of long period oscillatory components, long periods of recording of the electrocardiogram are required. For the identification of chaotic components, special methods of non-linear analysis have been developed and will be briefly discussed in Section 3.5.2. In any case, the deterministic components of the HRVS associated with autonomic cardiac control are basically contained in the HF and the LF spectral components, and these will receive most attention. 2.5. An index of sympatho6agal balance based on the power spectrum The two divisions of the ANS are classically seen working in a reciprocal manner, with increases in one division associated with decreases in the other [20]. Although this reciprocal modulation does not occur in some physiological states, a non-invasive index of sympathovagal balance obtained through the analysis of the power spectrum is clearly of physiological and clinical use. The relative ratio between the different components of the power spectrum has been used as such an index [48]. A linear relation of the area of the HF component and cardiac vagal tone obtained pharmacologically has been demonstrated [39,40]. Similarly, a linear relationship between the LF component and sympathetic activity has also been established [22]. The suitability of this index of sympathovagal balance has been shown during mental stress, tilt and mild exercise [49] but not when sympathetic drive is high such as during heavy dynamic exercise [49] or during baroreceptor loading [37]. 3. Short-term heart rate variations can be studied with appropriate techniques and analysed with relatively simple mathematical tools A detailed algorithm on how to carry out the spectral analysis of SHRV has already been published [9]. The purpose here is to review the different steps of the procedure, specifically those required for the application of the most commonly used spectral tool, which is the fast Fourier transform (FFT). In Fig. 3 a step-bystep scheme is provided as a guide through this part, which will include the accurate detection of each cardiac beat from the signal of choice, the correction of artifacts and the preparation of the time series for spectral analysis. In the second part, the FFT and the autoregressive method will be described and their limitations discussed and compared with alternative procedures such as time–frequency methods, wavelet analysis and non-linear fractal methods. J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 3.1. Accurate detection of instantaneous heart rate The accurate detection of beat-to-beat heart rate usually relies on tachographs, analog devices that trigger on the rising slope of the QRS wave and measure time between trigger pulses in real time. The alternative is the storage of the analog signal on tape for posterior analysis, either analog post-processing using tachographs or digital processing via computers (Holter systems, for instance). Nowadays, the complete digitalization and storage of the signal on digital devices through analog-to-digital conversion hardware is the most convenient method to use. Depending on the way the signal is stored, the detection can be carried out in real-time or offline. Real-time detection (on-line) with analog or digital tachographs [56] is convenient in terms of storage capacity because only the time of each event is stored. On the other hand, off-line detection is advantageous because the signal can be analyzed many times and detection artifacts can be easily discovered and corrected. With the 451 current prices of digital storage, it is a good advice to record the entire signal even with good on-line detectors in operation. 3.2. Correction of artifacts in beat-to-beat instantaneous heart rate series. Need or con6enience? SHRV analysis requires long periods of recording, and this usually results in the introduction of errors in the time data series associated with periods of low signal quality or artifacts in the QRS detection routine. Although this is a common problem encountered in any approach to the analysis of SHRV, it has not been thoroughly treated. The most common approach consists in manually editing the data series, splitting the long artifactual R–R intervals caused by missed beats or joining consecutive short R–R intervals caused by the detection of P or T waves. As a usual practice, the data is discarded when more than 5% of the beats need correction. This solution is probably a good compromise but it still involves a lot of subjective decisions from the analyst/operator. This problem is accentuated in experiments on undisturbed animals that are allowed to move freely because the signal to noise ratio usually decreases. A correction routine based on non-linear filters and neural networks that will eliminate some of the subjective criteria associated with the manual edition of the data is currently under test in my laboratory. With this technique, the most common artifacts and the appropriate corrections are used to train the neural network, which can then be used to process the time series automatically. 3.3. Pre-processing of the time series Fig. 3. Step-by-step graphical scheme of the methodology for the estimation of the power spectrum of SHRV. See text for details. The beat-to-beat heart rate series is, by definition, sampled at a frequency-modulated rate [68], the instantaneous heart rate itself and because of that has been named the Interval Tachogram [58]. Some authors prefer to transform this time series to a time evenly sampled series using linear interpolation procedures between consecutive beats. This new series has been called the Interval Function [58]. Since the pioneering work of Akselrod and co-workers [5], other authors have used the Interval Function as the basis for spectral analysis [25,27]. In this case, a proper selection of the sampling frequency of the new time series is needed. Sampling frequencies from 4 [41], 2 [42] or to 1 Hz [35] have been used in human studies. Higher sampling frequencies might be required when working with higher heart rates. Despite the extensive use of interpolation procedures, it has been demonstrated that the FFT algorithm operates equally well with the Interval Tachogram because the resulting interval spectrum is completely equivalent [29]. By removing the interpolation step, the processing 452 J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 tral resolution and to overcome stationarity limitations, most of our knowledge on SHRV and autonomic cardiac modulation is based on two fundamental algorithms: the FFT and the autoregressive modelling algorithm. Fig. 4. Demonstration of the truncation effect depending on the selection of the finite signal to analyze. In the lower panel note the introduction of high frequency transients due to the ‘apparent’ truncation of the signal caused by the iteration of a finite signal. of the time series prior to spectral analysis is greatly simplified [9,11]. Other alternative ways to derive a variability signal from the cardiac event series have been reported [58] but are rarely used. A second step in the processing of the time series is important to prevent what is known as spectral leakage. Because the computation of the FFT requires an infinite data series, the FFT algorithm starts by iterating the time series infinite number of times, as shown in Fig. 4. If the whole signal contains exact multiples of the frequencies included, as happens in Fig. 4 top, no effects due to a finite data series will be observed in the power spectrum. However, if the signal is not in phase with itself, which is the most likely situation when multiple frequencies are present (shown in Fig. 4 bottom), a truncation effect occurs. This is called spectral leakage or truncation effect and is due to the presence of sudden transitions in the data that introduce high frequency noise in the power spectrum estimate. Spectral leakage can be corrected by applying a tapering window that smoothes the edges of the finite signal [18]. Many tapering windows are in use: Blackman – Harris [6]; Exact Blackman [41] or the Hanning window. The latter, also known as the cosinus taper, is the most widely used [22,42,62]. Importantly, the tapering window has the effect of reducing the overall variability, effect that is corrected after the FFT computation by dividing the spectral power at each frequency by 0.875 (if the Hanning window is used). 3.4. The FFT and autoregressi6e algorithms are the most commonly used tools to study the SHRV The final step in SHRV analysis includes the application of power spectrum estimation methods to characterize the frequency components associated with vagal and/or sympathetic outflow. Although new algorithms and methods are constantly improved to increase spec- 3.4.1. The fast Fourier transform Any signal can be described as a sum of sine waves and this decomposition is called the Fourier transform. An efficient algorithm to carry out this transformation is the FFT, which, with some improvements and modifications, is still in use in many applications such as voice analysis or vibration studies. The analysis of SHRV is another one of these applications. FFT algorithms impose some constraints on the signal to analyze because an evenly sampled, infinite and stationary time series is required. Although HR series do not fulfil these strict requirements, different techniques to minimize the errors are currently in use and will be discussed in detail in the framework of SHRV analysis in Section 4. 3.4.2. Autoregressi6e modeling An alternative method to the FFT is the autoregressive identification algorithm (AR) combined with power spectral estimation for the assessment of SHRV [14– 16]. The method fits the data to an a priori defined model and estimates the parameters of the model. The power spectrum implied by the model is then computed [57]. The AR approach offers some advantages over the classical Fourier analysis [50]: 1. Due to intrinsic quasi-randomness of HRV, AR methods enhance the extraction of the non-random oscillations superimposed on a wide-band noise. This type of noise is characteristic of the power spectrum estimation obtained with the FFT algorithm. 2. AR algorithms can automatically furnish the number, amplitude, and center frequency of the oscillatory components without requiring the a priori decision on which peaks will be considered. 3. AR methods operate efficiently on shorter series of events that are also more likely stationary. 4. The resolution of AR procedures is higher [61]. AR methods are more complex both in design and operation and this factor has limited its application. Although a priori decisions on the spectral components are not needed, the method still introduces a subjective consideration of the order of the AR model to evaluate, and there is no common agreement about it [49,66,67]. 3.4.3. FFT or AR modelling, which to choose? Both methods share a common goal: the estimation of the power spectrum of a signal. FFT-based methods are also called non-parametric methods because there is J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 no assumption on how the data were originated. AR methods are parametric because they require a priori information of the system under study. Thus, I suggest that FFT-based methods are still the best choice for the assessment of SHRV in comparative studies, where no previous knowledge of the system is available. In addition, FFT algorithms are readily available in many different languages, even in commercial statistical packages. Once the basic spectral content of the system is known and an initial model of the signal can be formulated, AR algorithms should be a better choice because they provide better frequency resolution and avoid the problems of spectral leakage (see Section 3.3). 3.5. New spectral analysis techniques are in continuous de6elopment to resol6e new problems and o6ercome current limitations FFT and AR methods have served a critical role in the understanding of basal autonomic cardiac control. However, these algorithms have limitations in the study of long-term non-linear variations of heart rate as well as in the analysis of transient alterations of heart rate. Although a detailed discussion of alternative procedures to overcome these limitations is out of the scope of this review, I will summarize the most representative. 3.5.1. Study of transient alterations of heart rate The need to study transient alterations of heart rate is directly linked to the localization of specific events in the spectral estimate. This need has to be studied under the framework of the uncertainty principle, which states that arbitrarily good time and frequency resolutions, at the same location, cannot be achieved. Some methods that can overcome this problem and be instrumental in understanding the modulation of heart rate under timevarying conditions are described here. A more extensive description of these methods can be found in the excellent book by Akay [1]. During classical conditioning tests an animal learns that a signal predicts the occurrence of a traumatic or pleasing event. The signal itself elicits a complex, highly dynamic sequence of changes, the so-called conditioned response. To study these fast changes involved in the conditioned response a complex demodulation algorithm has been proposed [64]. Complex demodulation provides a good solution to this problem because it provides time local estimates of the properties of the process. Joint time–frequency analysis (JTFA) is another alternative to balance spectral versus time resolution. It is based on the recursive implementation of power spectrum estimation methods using the Short-time Fourier transform, the Gabor spectrogram or the Wigner-Ville distribution. It has been used to demonstrate that transient ischemic attacks in humans are preceded by an 453 activation of the sympathetic innervation of the heart [21]. The newest methodology to study transient changes in the HRVS is based on time–scale methods, also known as wavelet transforms. Their utility in the understanding of the physiology of HRV has recently been demonstrated during antistenotic surgery of the carotid artery. In this case, the declamping of the carotid vessel after surgery is followed by a significant increase of the power of the high frequency spectral bands, suggesting a recovery of the autonomic modulation of the heart [2]. Interestingly, the application of the STFT transform rendered imprecise conclusions, suggesting that wavelet transforms are more appropriately suited for the study of transient alterations than time–frequency methods. The wide application of wavelet transforms in other areas of biomedical engineering such as the analysis of pulmonary hemodynamics [45] or ECG compression and characterization [28,59] envisions an important role for wavelet transforms in our future understanding of physiological processes. 3.5.2. Methods of non-linear and fractal analysis The presence of self-similarity features in the HRVS revealed by a non-flat 1/f spectra [43] opened up a new area of study in the understanding of cardiac dynamics. Self-similarity is indicative of the presence of aperiodic but deterministic components also known as fractals. These chaotic components are all embedded in the VLF band described in Section 2.4, and are thought to be an important part of the regulatory repertoire of the healthy heart [36]. From a clinical point of view this suggestion has been applied to the monitoring of sudden infant death syndrome, sudden cardiac death and aging using the approximate entropy measurement developed by Pincus and co-workers (reviewed in [17]). The physiological mechanisms responsible for the genesis of fractal HRV, however, are largely unknown. Blood pressure regulation through the baroreflex and respiratory sinus arhythmia are poorly related to the fractal HRV [24,71]. As to the effector mechanisms, the sympathetic nervous system plays a minor role in modulating fractal HRV dynamics [73], and the parasympathetic nervous system seems to be largely responsible [74]. The physiological study of the fractal components of the HRVS has greatly benefited from the coarse graining spectral analysis method developed by Yamamoto and Hughson [72], which permits the separation and quantification of fractal and periodic components. 4. The use of power spectrum estimation methods requires the understanding of its limitations and a proper application of solutions The algorithms required in the analysis of SHRV via the power spectrum are conceptually simple. However, 454 J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 their practical implementation requires certain considerations of the processing of the cardiac-related signal that will largely determine the quality of the results. In the next sections I will discuss some important considerations to carry out the spectral analysis of iHR series such as the type and the quality of the signal to use, the signal processing steps and the length of the recording period. As a corollary to this section, the statistical reliability of the interval spectrum obtained from the FFT algorithm will be discussed. 4.1. What cardiac-related signals are appropriate for the analysis of SHRV? The electrocardiogram (ECG) is the most appropriate signal to study SHRV because it offers the most accurate representation of the electrical cardiac events. In particular, the QRS complex of the ECG sharply defines the onset of ventricular electrical depolarization and is the closest approach to time the occurrence of pacemaker potentials, which in turn are modulated by the autonomic outflow. The simplicity and little invasivity of ECG recording have been exploited to study SHRV in a wide variety of species, from fish [11] and Fig. 5. Comparison of instantaneous heart rates obtained from ECG and blood pressure signals. (A) Simultaneous recording of the ECG and the blood pressure trace in a saltwater crocodile Crocodylus porosus. (B) Relationship between heart rate and the relative difference in instantaneous rate as estimated from the two different signals. Data as mean 9SD. Open symbols show the maximum and minimum error at each heart rate. reptiles [38] to mammals ([4,39,54] among many others). If the ECG signal cannot be recorded, can other signals be used? For example, average heart rates have been routinely obtained from other signals like blood pressure, blood flow, finger pulse pressure, heart sonography, plethysmography or Doppler ultrasound imaging among others. What determines if a cardiac-related signal is suitable for the study of SHRV? The main requirement is a good correspondence between the signal of choice and the standard ECG signal. Commonly, the signal of choice will be delayed in relation to the bioelectric signal. For instance, the QRS complex precedes the onset of systolic blood pressure in the cardiac cycle (Fig. 5A). If this delay is relatively constant, we can conclude that blood pressure is a reasonable estimator of instantaneous heart rate. This is what occurs in the example presented in Fig. 5, that compares the instantaneous heart rate obtained simultaneously from the ECG and the femoral blood pressure trace in the saltwater crocodile Crocodylus porosus [10]. The results from eight animals (2000 heartbeats randomly picked from each animal) support several conclusions: 1. The relative difference between instantaneous HR (iHR) obtained from ECG or BP signals is rate dependent, i.e. a larger error is obtained at larger iHR. 2. The distribution of relative differences is symmetrical. For a given iHR obtained from the ECG the probability of overestimating or underestimating iHR using the BP signal is the same. 3. The average maximum error is 9 2%. The impact of this error on the spectral estimate will be discussed in detail in the next section but taking into account the low average heart rates and the high HRV, the blood pressure signal is appropriate in this case to analyze the SHRV. Another example to discuss the suitability of cardiacrelated signals to estimate instantaneous heart rates is the chicken embryo. The chicken embryo is an excellent model for the study of the ontogeny of cardiovascular regulation. A quick glance at the literature reveals many different techniques directly or indirectly related with different mechanical or electrical phenomena of the cardiac cycle that have been used to measure heart rate. These techniques are outlined in Fig. 6A in relation with the developmental window in which they can be used. Most of these signals can be immediately excluded in order to estimate the instantaneous heart rate for SHRV analysis. The acoustocardiogram, ballistocardiogram, pulse oximetry trace and obviously the visual observation methods are unsuitable because the signal under study reflects a complex interaction between car- J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 455 vessel. This procedure has little impact on the embryo because it can be performed on a small circular opening on the eggshell (5-mm diameter) and can be used reliably from day 7 onwards. In these cases we have to assume that vascular compliance does not change over time or that the time lag between electrical cardiac systole and the maximum speed or pressure in the vessel is constant. Although these assumptions have not yet been verified, it is feasible that even small deviations would not have a large impact on the SHRV spectra. In Fig. 6B, an example of the ECG, the impedance cardiogram (IP) and the Doppler velocity (DOP) signals are shown to compare the temporal resolution of the systolic events. Note the different definition of the peak maxima, clearly distinguished for the ECG trace but flattened and more susceptible to noise contamination for DOP and IP. 4.2. Which are the parameters during signal processing that critically determine the quality of the heat rate series? Fig. 6. (A) Outline of the different techniques used in the literature to measure heart rate in chicken embryos. Each method is displayed against a developmental ruler to delimit the ontogenetic window where it can be used. (B) Trace example of three different signals obtained in the same chicken embryo (HH stage 20). Note the different definition of the peak maxima, well defined for the ECG trace and considerably flattened for the Doppler Flow signals and the impedance cardiogram. diac and embryonic movements, all of them buffered and dampened by the viscosity of the egg albumen. When obtained from electrodes inserted in the shell, the impedance cardiogram has the same disadvantage. None of these signals can guarantee a constant delay between pacemaker potentials and the fiduciary point detected in the signal of choice More reliable impedance cardiograms can be obtained by inserting the electrodes close to the heart at those embryonic stages where the embryo floats on top of the yolk sack. We have recently employed this technique to obtain noise-free 10-min recordings of iHR from Hamburger Hamilton Stage 18 to HH Stage 30 chicks. However, this technique constraints the measurements to a very specific window in cardiovascular development. Methods based on direct measurements of Doppler shifts or pressure in extraembryonic vessels are probably the most appropriate to derive precise iHR time series when the ECG is not available. Blood pressure recordings are intrinsically more invasive than blood flow measurements because the shell needs to be penetrated in order to catheterize the vessel. However, a Doppler crystal can be easily placed on top of the external shell membrane overlying an extraembryonic In order to time and detect each cardiac event the digitalization of the cardiac signal is required, i.e. the analog signal is converted to a sequence of numbers. The key parameters governing this transformation are the resolution of the analog-to-digital (AD) converter and the sampling rate. The resolution of the AD converter is important for a proper reconstruction of the signal but it is of little relevance in terms of event timing. Nowadays, most commercially available signal acquisition devices will have at least a 12-bit resolution, which is sufficient for SHRV analysis. More relevant is the choice of an appropriate sampling frequency. The quality of the iHR series is largely dependent on it because low sampling frequencies introduce an error in the determination of the iHR, resulting in a low signal-to-noise ratio. Although the Nyquist theorem (a signal must be sampled at a rate at least twice that of its highest frequency component) is commonly used as an indicator of an appropriate sampling frequency, it is not sufficient to guarantee a good signal-to-noise ratio. The relationship between the average signal-to-noise ratio (aSNR) and the sampling frequency can be described by the following equation (adapted from [51]): aSNR= 6·Var·SF2 − 1 (1) where Var is the total variance of the signal and SF is the sampling frequency in Hz. As the sampling frequency is reduced, aSNR decreases. Interestingly, the total variance of the signal also plays a role in the aSNR, the lower the variance the lower the ASNR for a given sampling frequency. In human studies, sampling frequencies lower than 128 Hz J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 456 should be avoided, which has important implications when using data from Holter recordings [51]. In comparative studies, sampling frequencies of 250 Hz can be safely applied in most cases where heart rates range between 10 and 100 beats·min − 1 and the variance is large. However, at higher heart rates, particularly if lower variances are involved, care needs to be taken to sample the signal with higher frequencies or to apply correction routines that will be discussed below. This can be shown by modeling the maximum error (expressed in beats·min − 1) in the measurement of instantaneous heart rate as a function of the sampling frequency: Error= 2HR2 60SF+HR (2) Fig. 7 plots the maximum error incurred at different sampling frequencies when average heart rate is 30, 60, 120 or 240 beats·min − 1. For example, for heart rates below 120 beats·min − 1, a maximum sampling frequency of 500 Hz will suffice to estimate each instantaneous heart rate with an accuracy of 1 beat·min − 1. However, due to the reciprocal relationship between time and rate, much higher sampling frequencies are required in order to maintain the same level of accuracy when average heart rates are about 240 beats·min − 1. An example where sampling frequencies are critical in the determination of the SHRV estimation is the embryonic chicken model. Two factors contribute to it: (a) the high average heart rate (over 250 beats·min − 1 for the last half of incubation) and (b) the intrinsic low variability of short-term heart rate changes. In this case, a high sampling frequency is required if a reasonable aSNR is to be obtained. If practical reasons limit the utilization of the optimum high sampling frequency, alternative oversampling routines need to be applied. Oversampling algorithms work ‘filling the gaps’ and increasing the time resolution of the signal by various interpolation procedures. A signal sampled at 500 Hz can be easily converted to 1000 Hz by interpolating a new point between each pair of truly acquired points. A sinusoid interpolation procedure to reconstruct acoustocardiograms sampled at 50 Hz from chicken embryos has been recently reported [3]. In this example the signal was oversampled at 4000 Hz (i.e. a ratio SFoversampled:SFreal of 80:1) in order to achieve a proper time resolution in the detection of the cardiac event. The authors based their criteria on a comparison between signals sampled at 4kHz and the same signal undersampled at their working sampling frequency of 50 Hz. It is important to stress however, that a proper oversampling ratio will directly depend on the type of signal under study and that this procedure can never restore the original signal with complete accuracy. 4.3. Which is the appropriate length of the heart rate series for SHRV analysis? The length of the iHR series is not a matter of convenience but a fine balance between two important issues: stationarity of the time series and resolution of the spectral estimate. The longer the recording time, the better will be the spectral resolution because it will be based on more data points. However, by extending the recording time it is also more likely to run into problems with non-stationary conditions. There is no fixed rule to define how long the iHR series need to be. What follows is an explanation of some examples with the aim that the criteria discussed will be helpful to determine the best conditions for any new study. Fig. 7. Effect of sampling frequency on the error in the accuracy in the determination of heart rate. (A) Description of the empirical model. (B) Plot of the error at four different average heart rates as a function of the sampling frequency. 4.3.1. Stationarity conditions Most algorithms of spectral analysis require that the time series is stationary. This is particularly true for non-parametric algorithms as described in Section 3. A random process is stationary if its statistical characteristics are invariant under time shifts, that is, if they remain the same when t is replaced by t+Dt, where Dt is arbitrary. Although strict stationarity is unknown in biological systems [48], partial stationarity is often sufficient to obtain reliable results. J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 457 series, the better the spectral resolution, but there will also be a higher probability that the series is non-stationary. In practice, the FFT is usually computed in fragments of 29 –211 points, which provide a sufficient resolution to study the LF and HF spectral components but is inefficient to resolve the VLF spectral component. This is not critical for the understanding of shortterm neural control of the heart because the VLF component is determined by a complex set of neural and humoral factors that requires the application of non-linear techniques such as chaos analysis (see previous Section 2.3). 4.4. Statistical reliability of the power spectrum Fig. 8. Examples of heart rate series in three different species to illustrate the presence of non-stationarities. x-axis: number of beats. Upper panel, data from the red eared slider Trachemys scripta (stars show the start of ventilation episodes) [7]. Middle panel, data from the Atlantic cod Gadus morhua [7]. Lower panel, data from the Atlantic salmon Salmo salar [11]. Several examples of stationary and non-stationary instantaneous heart rate series are shown in Fig. 8. Long-term heart rate series in reptiles are always nonstationary due to the highly unpredictable episodic nature of the respiratory events. Ventilation bouts are always coupled to tachycardia in order to improve oxygen uptake when the lungs are ventilated (cardiorespiratory synchrony, [70]). This is seen in Fig. 8 for the red-eared slider turtle Trachemys scripta, where average heart rate during apnea was increased at the onset of a ventilatory episode (signaled by stars in the figure). In fish, non-stationarities often occur as a result of external disturbances to the animal resulting in sudden bradycardias or tachycardias (as seen in the Atlantic cod Gadus morhua in the middle panel on the right of Fig. 8), and special care needs to be taken to avoid these external perturbations. A common test to verify stationary conditions is the use of a run test [18]. The run test assumes that any non-stationarity of interest will be revealed by changes in the standard deviation of the data. This is likely to occur for HR series, where non-stationarities of biological origin due to tachycardic or bradycardic periods are usually coupled with changes in the total variation of the signal. 4.3.2. Resolution of the spectral estimate The resolution of the spectra is the reciprocal of the total recording time [34]. Thus, the longer the data The periodogram that results of each single computation of the FFT algorithm is a poor estimator of the power spectrum due to the limitation of non-parametric FFT-based methods previously discussed [57]. In order to obtain a better estimate, two different methods are of common use: the Welch method and the Blackman– Tukey method. The Welch method improves the statistical likelihood of the estimated power spectrum by averaging the periodogram of consecutive segments of data. Using this approach, the iHR series is divided in segments short enough to be stationary and long enough not to limit the spectral resolution. The Blackman–Tukey method relies on smoothing the periodogram via a moving average window. Both methods are not mutually exclusive and are usually combined. An extended discussion on these methods and their basic statistical properties can be found elsewhere [57]. 5. Are we trying to describe noise? It should be clear at this point that heart rate variations reflect the output of a complex system and include harmonic and non-harmonic components of physiological origin. Aside, the processing of the cardiac-event signal might introduce artifactual noise that is important to minimize in order to obtain meaningful results. If the criteria discussed in Section 4 are taken into account, the HRVS is a coherent representation of the combined complexities of chronotropic cardiac regulation irrespective of the species and the stage of development. In adult individuals this complexity is channeled through the autonomic innervation of the sinoatrial node of the heart. However, during early embryonic development, HRV might be uncoupled from the immature autonomic innervation and linked to the mechanical stresses and tensions of cardiac organogenesis, and this is an interesting area of research that remains largely unexplored. 458 J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 The degree to which the different methods of power spectrum estimation are able to uncover the periodic components of heart rate variations is directly related to the technique itself and to the physiological status of the system under study. On one hand, each technique has advantages and limitations such as the sensitivity to non-stationarities or spectral leakage and the spectral resolution achieved. They have been discussed in Sections 3 and 4. On the other hand, all the components of the HRVS are subjected to the fine balance of the sympathovagal autonomic outflow, which in turn is very sensitive and responds promptly to internal and external perturbations. Not surprisingly, some of the best results in comparative studies have been obtained by using telemetry equipment on undisturbed animals [11,31]. To conclude, the application of spectral analysis techniques to unveil the intricacies of the autonomic regulation of heart rate in non-mammalian species is not only possible but also necessary to understand the evolution of cardiac control under different environmental and internal perturbations. Thus, the variations of instantaneous heart rate should not be seen as noise but as a valuable resource providing new information on the mechanisms of heart rate homeodynamics. The utility of the power spectrum estimation methods is now firmly established and with this background knowledge it is then possible to approach cardiovascular regulation in a highly integrative manner without denying the value and the need of other experimental methods. Acknowledgements The Dan Charitable Trust Fund for Research in Biological Sciences of the Nippon Trust Bank Limited provided financial support for the presentation of this work at the International Symposium on ‘‘Cardiac Rhythms in Animals: regulation, development and environmental influences’’ held in Muroran, Japan. Support from Waxman International is also greatly appreciated. References [1] Akay M. Detection and Estimation Methods for Biomedical Signals. San Diego: Academic Press, 1996. [2] Akay M, Landesberg G, Welkowitz W, Akay YM, Sapoznikov D. Carotid – cardiac interaction: heart rate variability during the unblocking of the carotid artery. In: Sideman S, Beyar R, editors. Interactive Phenomena in the Cardiac System. New York: Plenum, 1993:365 – 72. [3] Akiyama R, Ono H, Höchel J, Pearson JT, Tazawa H. Non-invasive determination of instantaneous heart rate in developing avian embryos by means of acoustocardiogram. Med Biol Eng Comput 1997;35:323 – 7. [4] Akselrod S, Gordon D, Madwed JB, Snidman NC, Shannon DC, Cohen RJ. Hemodynamic regulation: investigation by spectral analysis. Am J Physiol 1985;249:H867– 75. [5] Akselrod S, Gordon D, Ubel FA, Shannon DC, Barger AC, Cohen RJ. Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control. Science 1981;213:220 – 2. [6] Allen AM, Adams JM, Guyenet PG. Role of the spinal cord in generating the 2-Hz to 6-Hz rhythm in rat sympathetic outflow. Am J Physiol 1993;264:R938– 45. [7] Altimiras J. Heart Rate Variability. Its Significance in Lower Vertebrates. Ph.D. Thesis. Barcelona: Department of Biochemistry and Physiology, University of Barcelona, 1995. [8] Altimiras J, Aissaoui A, Tort L. Is the short-term modulation of heart rate in teleost fish physiologically significant? Assessment by spectral analysis techniques. Braz J Med Biol Res 1995;28:1197– 206. [9] Altimiras J, Feliu M, Aissaoui A, Tort L. Computing heart rate variability using spectral analysis techniques: HRVUAB, a readyto-use program. CABIOS 1994;10:559 – 62. [10] Altimiras J, Franklin CE, Axelsson M. Relationships between blood pressure and heart rate in the saltwater crocodile Crocodylus porosus. J Exp Biol 1998;201:2235– 42. [11] Altimiras J, Johnstone ADF, Lucas MC, Priede IG. Sex differences in the heart rate variability spectrum of free-swimming Atlantic salmon (Salmo salar L.) during the spawning season. Phys Zool 1996;69:770 – 84. [12] Altman PL, Dittmer DS. Respiration and Circulation. Bethesda, MD: Federation of American Societies for Experimental Biology, 1971. [13] Axelsson M. The importance of nervous and humoral mechanisms in the control of cardiac performance in the Atlantic cod Gadus morhua at rest and during non-exhaustive exercise. J Exp Biol 1988;137:287 – 303. [14] Baselli G, Cerutti S, Civardi S, Liberati D, Lombardi F, Malliani A, Pagani M. Spectral and cross-spectral analysis of heart rate and arterial blood pressure variability signals. Comput Biomed Res 1986;19:520 – 34. [15] Baselli G, Cerutti S, Civardi S, Lombardi F, Malliani A, Merri M, Pagani M, Rizzo G. Heart rate variability signal processing: a quantitative approach as an aid to diagnosis in cardiovascular pathologies. Int J Bio-Med Comput 1987;20:51 – 70. [16] Baselli G, Cerutti S, Civardi S, Malliani A, Orsi G, Pagani M, Rizzo G. Parameter extraction from heart rate and arterial blood pressure variability signals in dogs for the validation of a physiological model. Comput Biol Med 1988;18:1 – 16. [17] Bassingthwaighte JB, Liebovitch LS, West BJ. Fractal Physiology. New York: Oxford University Press, 1994. [18] Bendat JS, Piersol AG. Random Data: Analysis and Measurement Procedures. New York: Wiley Interscience, 1971. [19] Bennett AF. Interindividual variability: an underutilitzed resource. In: Feder ME, Bennett AF, Burggren WW, Huey RB, editors. New Directions in Ecological Physiology. Cambridge: Cambridge University Press, 1987:147 – 69. [20] Berntson GG, Cacioppo JT, Quigley KS. Respiratory sinus arrhythmia-autonomic origins, physiological mechanisms, and psychophysiological implications. Psychophysiology 1993;30:183– 96. [21] Bianchi AM, Mainardi L, Petrucci E, Signorini MG, Mainardi M, Cerutti S. Time-variant power spectrum analysis for the detection of transient episodes in HRV signal. IEEE Trans Biomed Eng 1993;40:136 – 44. [22] Bootsma M, Swenne CA, Vanbolhuis HH, Chang PC, Cats VM, Bruschke AVG. Heart rate and heart rate variability as indexes of sympathovagal balance. Am J Physiol 1994;266:H1565–71. [23] Burggren W, Tazawa H, Thompson D. Genetic and maternal environmental influences on embryonic physiology: intraspecific J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] [34] [35] [36] [37] [38] [39] [40] [41] [42] [43] [44] variability in avian embryonic heart rates. Isr J Zool 1994;40:351 – 62. Butler GC, Yamamoto Y, Hughson RL. Fractal nature of short term systolic BP and HR variability during lower body negative pressure. Am J Physiol 1994;267:R26–33. Cerutti C, Barres C, Paultre C. Baroreflex modulation of blood pressure and heart rate variabilities in rats: assessment by spectral analysis. Am J Physiol 1994;266:H1993–2000. Cerutti C, Gustin MP, Paultre CZ, Lo M, Julien C, Vincent M, Sassard J. Autonomic nervous system and cardiovascular variability in rats: a spectral analysis approach. Am J Pathol 1991;261:H1292– 9. Cerutti C, Gustin MP, Paultre CZ, Lo M, Julien C, Vincent M, Sassard J. Role of the autonomic nervous system in blood pressure and heart rate variability in rats — a spectral analysis approach. In: Dirienzo M, Mancia G, Parati G, Pedotti A, Zanchetti A, editors. Blood Pressure and Heart Rate Variability. Amsterdam: Ios Press, 1992:180 –91. Crowe JA, Gibson NM, Woolfson MS, Someck MG. Wavelet transform as a potential tool for ECG analysis and compression. J Biomed Eng 1992;14:268–72. De Boer RW, Karemaker JM, Strackee J. Comparing spectra of a series of point events particularly for heart rate variability data. IEEE Trans Biomed Eng 1984;31:384–7. De Vera L, González J. Power spectral analysis of short-term RR interval and arterial blood pressure oscillations in lizard (Gallotia galloti ): effects of parasympathetic blockade. Comp Biochem Physiol A 1997;118:671–8. De Vera L, Priede IG. The heart rate variability signal in rainbow trout (Oncorhynchus mykiss). J Exp Biol 1991;156:611–7. De Vera L, Priede IG. Ultradian oscillation in the heart rate of rainbow trout (Oncorrhynchus mykiss). Comp Biochem Physiol A 1993;106A:183– 6. Delaney RG, Lahiri S, Fishman AP. Aestivation of the African lungfish Protopterus aethiopicus: cardiovascular and respiratory functions. J Exp Biol 1974;61:111–28. Dempster J. Computer Analysis of Electrophysiological Signals. London: Academic Press, 1993. Elghozi J-L, Laude D, Girard A. Effects of respiration on blood pressure and heart rate variability in humans. Clin Exp Pharmacol Physiol 1991;18:735 –42. Goldberger AL. Is the normal heartbeat chaotic or homeostatic? NIPS 1991;6:87 – 91. Goldberger JJ, Ahmed MW, Parker MA, Kadish AH. Dissociation of heart rate variability from parasympathetic tone — rapid communication. Am J Physiol 1994;266:H2152–7. González J, De Vera L. Spectral analysis of heart rate variability of lizard, Gallotia galloti. Am J Physiol 1988;254:R242–8. Hayano J, Sakakibara Y, Yamada A, Yamada M, Mukai S, Fujinami T, Yokoyama K, Watanabe Y, Takata K. Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects. Am J Cardiol 1991;15:199–204. Hayano J, Mukai S, Sakakibara M, Okada A, Takata K, Fujinami T. Effects of respiratory interval on vagal modulation of heart rate. Am J Physiol 1994;267:H33–40. Jaffe RS, Fung DL, Behrman KH. Optimal frequency ranges for extracting information on autonomic activity from the heart rate spectrogram. J Autonom Nerv Syst 1994;46:37–46. Kingwell BA, Thompson JM, Kaye DM, McPherson GA, Jennings GL, Esler MD. Heart rate spectral analysis, cardiac norepinephrine spillover, and muscle sympathetic nerve activity during human sympathetic nervous activation and failure. Circulation 1994;90:234 – 40. Kobayashi M, Musha T. 1/f fluctuation of heartbeat period. IEEE Trans Biomed Eng 1982;29:456–7. Levy MN, Martin PJ. Neural control of the heart. In: Berne RM, [45] [46] [47] [48] [49] [50] [51] [52] [53] [54] [55] [56] [57] [58] [59] [60] [61] [62] [63] [64] 459 Sperelakis N, editors. Handbook of Physiology. The Cardiovascular System. I. The heart. Bethesda, MD: American Physiological Society, 1979:581 – 620. Li Z, Grant BJB, Lieber BB. Time-varying pulmonary arterial input impedance via wavelet decomposition. J Appl Physiol 1995;78:2309 – 19. Livnat A, Zehr JE, Broten TP. Ultradian oscillations in blood pressure and heart rate in free-running dogs. Am J Physiol 1984;246:R817– 24. Madwed JB, Albretcht P, Mark RG, Cohen RJ. Low-frequency oscillations in arterial pressure and heart rate: a simple computer model. Am J Physiol 1989;256:H1573– 9. Malliani A, Lombardi F, Pagani M. Power spectrum analysis of heart rate variability — a tool to explore neural regulatory mechanisms. Br Heart J 1994;71:1 – 2. Malliani A, Pagani M, Lombardi F. Importance of appropriate spectral methodology to assess heart rate variability in the frequency domain. Hypertension 1994;24:140 – 1. Malliani A, Pagani M, Lombardi F, Cerutti S. Cardiovascular neural regulation explored in the frequency domain. Circulation 1991;84:482 – 92. Merri M, Farden DC, Mottley JC, Titlebaum EL. Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability. IEEE Trans Biomed Eng 1990;17:99–106. Milsom WK, Burlington RF, Burleson ML. Vagal influence on heart rate in hibernating ground squirrels. J Exp Biol 1993;185:25– 32. Moser M, Lehofer M, Sedminek A, Lux M, Zapotoczky HG, Kenner T, Noordergraaf A. Heart rate variability as a prognostic tool in cardiology — a contribution to the problem from a theoretical point of view. Circulation 1994;90:1078 – 82. Novak P, Novak V. Time/frequency mapping of the heart rate, blood pressure and respiratory signals. Med Biol Eng Comput 1993;31:103 – 10. Ong JJC, Sarma JSM, Venkataraman K, Levin SR, Singh BN. Circadian rhythmicity of heart rate and QTc interval in diabetic autonomic neuropathy — implications for the mechanism of sudden death. Am Heart J 1993;125:744 – 52. Pan J, Tompkins WJ. A real-time QRS detection algorithm. IEEE Trans Biomed Eng 1985;32:230 – 6. Proakis JG, Manolakis DG. Digital Signal Processing. Principles, Algorithms and Applications. Singapore: Maxwell MacMillan International, 1992. Rompelman O, Coenen AJRM, Kitney RI. Measurement of heart-rate variability. Part 1-Comparative study of heart-rate variability analysis methods. Med Biol Eng Comput 1977;15:233– 9. Sahambi JS, Tandon SN, Bhatt RKP. Using Wavelet transforms for ECG characterization. IEEE Eng Med Biol Mag 1997;16:77– 83. Sands KE, Appel ML, Lilly LS, Schoen FJ, Mudge GHJ, Cohen RJ. Power spectrum analysis of heart rate variability in human cardiac transplant recipients. Circulation 1989;79:76 – 82. Sapoznikov D, Luria MH, Mahler Y, Gotsman MS. Computer processing of artifact and arrhythmias in heart rate variability analysis. Comput Method Program Biomed 1992;39:75– 84. Sarma JSM, Singh N, Schoenbaum MP, Venkataraman K, Singh BN. Circadian and power spectral changes of RR and QT intervals during treatment of patients with angina pectoris with nadolol providing evidence for differential autonomic modulation of heart rate and ventricular repolarization. Am J Cardiol 1994;74:131– 6. Saul JP. Beat-to-beat variations of heart rate reflect modulation of cardiac autonomic outflow. NIPS 1990;5:32 – 7. Shin SJ, Tapp WN, Reisman SS, Natelson BH. Assessment of autonomic regulation of heart rate variability by the method of 460 J. Altimiras / Comparati6e Biochemistry and Physiology, Part A 124 (1999) 447–460 complex demodulation. IEEE Trans Biomed Eng 1989;36:274 – 83. [65] Smith JJ, Kampine JP. Circulatory Physiology — The Essentials. Baltimore: Williams and Wilkins, 1990. [66] Takalo R, Korhonen I, Turjanmaa V, Majahalme S, Tuomisto M, Uusitalo A. Short-term variability of blood pressure and heart rate in borderline and mildly hypertensive subjects. Hypertension 1994;23:18 – 24. [67] Takalo R, Korhonen I, Turjanmaa V, Majahalme S, Uusitalo A. Importance of appropriate spectral methodology to assess heart rate variability in the frequency domain — response. Hypertension 1994;24:141 – 2. [68] Tenvoorde BJ, Faes TJC, Rompelman O. Spectra of data sampled at frequency-modulated rates in application to cardiovascular signals. 1. Analytical derivation of the spectra. Med Biol Eng Comput 1994;32:63 –70. [69] Territo PR, Altimiras J. The ontogeny of cardio-respiratory . [70] [71] [72] [73] [74] function under chronically altered gas compositions in Xenopus lae6is. Resp Physiol 1998;111:311 – 23. Wang T, Hicks JW. Cardiorespiratory synchrony in turtles. J Exp Biol 1996;199:1791 – 800. Yamamoto Y, Fortrat J-O, Hughson RL. On the fractal nature of heart rate variability in humans: effects of respiratory sinus arrhythmia. Am J Physiol 1995;269:H480– 6. Yamamoto Y, Hughson RL. Coarse-graining spectral analysis: new method for studying heart rate variability. J Appl Physiol 1991;71:1143 – 50. Yamamoto Y, Hughson RL. On the fractal nature of heart rate variability in humans: effects of data length and beta-adrenergic blockade. Am J Physiol 1994;266:R40 – 9. Yamamoto Y, Nakamura Y, Sato H, Yamamoto M, Kato K, Hughson RL. On the fractal nature of heart rate variability in humans: effects of vagal blockade. Am J Physiol 1995;269:R830– 7.