ZIEHL-NEELSEN for acid-fast bacteria 04 – 110802 IVD In-vitro diagnostic medical device | CND Code: W01030799 number of tests ........................... 100 procedure time ............................ 50 minutes product validity ............................ 2 years storage temperature ..................... 15 - 25 °C complementary equipment........... not requested Expected aim Product for the preparation of cyto-histological samples for optical microscopy. Application To show pathogenic mycobacteria (especially Koch’s bacillus) in histologic sections, sputum smears and culture smears. Principle Acid resistance is a particular dyeing features of myco-bacteria. Once they have been stained with carbol fuchsin they have the capacity to remain red even if they undergo strong decolorizations. Acid resistance is usually ascribed to the special composition of mycobacteria’s cell walls, which are very rich in lipides. Method 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) Results Koch’ s bacillus and other acid resistant elements ..............................................................................Red Nuclei .................................................................................................................................................. Blue Reagents A) B) C) D) Warning and precaution The product must be used exclusively by specialized technical operators. The product is classified as hazardous. Read with attention the information written on the label (dangerous symbols, risks and safety phrases). Consult always the safety data sheet where the information about the risks of the preparation, precautionary measures during use, first aid and disposal are available. Do not use if primary packaging is damaged. Storage Store the preparation at room temperature. Keep the containers tightly closed. Stability After the first opening, the product is usable until the expiry date, if correctly stored. Disposal Hazardous preparation: observe all state and local environmental regulations regarding waste disposal. Bring section to distilled water. Put on the section 10 drops of reagent A: leave to act 10 minutes. Rinse in distilled water. Put on the section 10 drops of reagent B: leave to act 30 minutes. Wash in distilled water and dry the slide with filter paper. Put on the section 10 drops of reagent C: leave to act 1 minute. Rinse 3 minutes in tap water. Put on the section 10 drops of reagent D: leave to act 2 minutes. Wash in distilled water and blue in running tap water for 5 minutes. Dehydrate through ascending alcohols, xylene and mount. Periodic acid solution.................................................................................................................. 30 ml Carbolfuchsin solution ................................................................................................................ 30 ml Acid differentiation buffer ............................................................................................................ 30 ml Mayer’s hemalum ....................................................................................................................... 30 ml Producer: Bio-Optica Milano s.p.a. Page 1 di 2 Bio Optica Milano s.p.a. via San Faustino 58 • I - 20134 Milano tel. +39 02212713.1 • fax +39 022153000 www.bio-optica.it References • • • Berg JW. Acid-fastness as a histochemical test J Histo-chem Cytochem 1953; 1: 436-441 Berg JW. Chemistry of acid-fastness Proc Soc Exp Biol Med 1953; 84: 196-198 Lillie RD. Acetic methylene blue counterstain in staining tissue in acid fast bacilli. Stain Technol 1944; 19-45 110802/L the kit is available with components in size of 1000 ml on request Date of issue: November 2013 Producer: Bio-Optica Milano s.p.a. Page 2 di 2 Bio Optica Milano s.p.a. via San Faustino 58 • I - 20134 Milano tel. +39 02212713.1 • fax +39 022153000 www.bio-optica.it