* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Constant Voltage LED Driver LCV
Stepper motor wikipedia , lookup
Electrical ballast wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electric battery wikipedia , lookup
History of electric power transmission wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Integrating ADC wikipedia , lookup
Power MOSFET wikipedia , lookup
Current source wikipedia , lookup
Schmitt trigger wikipedia , lookup
Distribution management system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Rechargeable battery wikipedia , lookup
Stray voltage wikipedia , lookup
Power electronics wikipedia , lookup
Alternating current wikipedia , lookup
Current mirror wikipedia , lookup
Voltage regulator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Constant Voltage LED Driver LCV Product Overview The LCV range is a versatile range of emergency lighting conversion equipment for 3 hour emergency lighting supply consisting of a high temperature Nickel Cadmium (NiCd) battery pack and converter/charger module. Using dc-dc switcher circuitry this range provides a constant voltage output (CV) for fixed voltage LEDs and panels. The LCV range offers reliability and compatibility with most types of low power LED sources, providing three hour duration emergency lighting at full output. The range is available in a wide range of LED voltage outputs and varying battery sizes, to suit the developing LED market. The LCV has extra circuitry so that it can provide a higher output voltage than the battery voltage. This means it is possible to drive a 24V load from a 3.6V battery, saving considerably on the number of battery cells required. The converter/charger module is housed in our standard HRN case and comes complete with 6 way and 4 way terminal blocks. The six way block allows connection of the unswitched 240V supply, irreversible battery connector and LED, whilst the four way block allows connection of the two low voltage leads from the LED driver maintaining supply, and two more out to the LEDs. All units are designed to give 3 hour duration and utilise 3, 4, 5, or 6 Cell 4Ah batteries to provide varying maximum output power. Most of the units are designed to run the LEDs at full 100% output, although some of the constant voltage versions can be set to slightly under run the LEDs to give full battery duration (3 hour). The Constant Voltage (Type CV) output units are available in any output voltage in the range 8-27V DC and the maximum loads available are: Unit type LCV/3/zz LCV/4/zz LCV/5/zz LCV/6/zz Number of Cells Maximum load power 3 3W 4 4W 5 5W 6 6W zz=output voltage required Select this type for constant voltage loads (Constant Voltage LED loads will usually have the voltage in their part number.) Normally use the smallest size battery capable of supporting the load for 3 hours, (maximum load =1W per Cell) and then specify the dc output voltage required. Typical Part numbers are as follows: LCV/3/10 Constant Voltage conversion pack utilising a 3 Cell 4Ah battery and providing a 10V DC output, suitable for a load of up to 3W. LCV/4/24 Constant Voltage Conversion pack utilising a 4 Cell 4Ah battery and providing a 24V DC output, suitable for a load of up to 4W. Tel +44 (0) 1708 372 223 Issue 1410 www.liteplan.com Fax +44 (0) 1708 371 345 Liteplan reserve the right to change colour, price or specification Page 1 of 3 Constant Voltage LED Driver LCV Conversion Service Due to the size constraints of LED luminaires and the necessary large size of emergency lighting batteries, the LCV converter/charger module and battery can be supplied in a separate remote box. (Add R suffix to above part numbers) For ease of wiring it will usually be advantageous to remove the LED driver from the luminaire and fix it within the remote box. Dependant on size of the driver this may fit inside standard remote boxes, or a larger size may be required. The LED luminaire can be converted for low voltage input, and the normal switched and unswitched 240V supplies can be taken to the remote box. A colour coded PVC Sleeved loom will be provided to connect the remote box to the luminaire. Attention should also be paid as to placing of the battery charge LED, as the compact size of LED luminaires may prohibit the battery charge LED from being placed in the luminaire. Typical Wiring TYPICAL STANDARD FITTING 240V AC SWITCHED SUPPLY L N CONSTANT CURRENT OR CONSTANT VOLTAGE LV OUTPUT TYPICAL FITTING BLACK LED DRIVER RED TYPICAL CONVERTED FITTING REMOTE BOX BATTERY TWISTED WHITE TWISTED RED RED BLACK CONSTANT CURRENT OR CONSTANT VOLTAGE LV OUTPUT LED INDICATOR LIMITED EMERGENCY LIGHTING LP/LED RANGE DANGER VOLTAGE OUTPUT ELECTRONIC CONTROL GEAR: DO NOT USE HIGH VOLTAGE INSULATION TEST INSTUMENT MAINS SUPPLY 220/240V AC 50HZ ± 1HZ 50mA MAX MIN & MAX CASE OPERATING TEMPERATURE 0°C - 70°C MADE IN ENGLAND FOR USE WITH NI-Cd BATTERY X 4AH NOM CURRENT = 1.1 AMP VOLTAGE RANGE FREQ. RANGE FOR INTERMITTENT OPERATION CHARGING CURRENT BATTERY SUPPLY RED WHITE RED BLACK UNSWITCHED 240V 50HZ AC SUPPLY + + L N FUSE L1 E L N L1 E L N 240V AC UNSWITCHED & SWITCHED SUPPLY LED DRIVER TYPICAL FITTING BLACK RED CHARGE LED Tel +44 (0) 1708 372 223 Issue 1410 www.liteplan.com Fax +44 (0) 1708 371 345 Liteplan reserve the right to change colour, price or specification Page 2 of 3 Constant Voltage LED Driver LCV Technical Specification The LCV converter/charger module is fitted with constant current charger circuit to recharge the battery within 24 hours, and to maintain it in premium condition. There is a 2 pole changeover relay to completely isolate the Led driver from the converter circuit upon mains failure. The battery has an additional single pole deep discharge relay to prevent the battery being discharged below the required level at the end of discharge. In a converted Low voltage LED luminaire the LCV pack is wired between the standard LV LED driver and the LED luminaire. The Constant Voltage Output is fully overload protected, and loading it beyond its rated load will result in a shorter duration output, and a lower output voltage. Specification Summary LCV/3/zz Mains Supply Power Rating Watts Mains Frequency Charge Current Recharge Period Battery Pack Output Voltage Voltage stability Maximum load Module size LxWxH 3 x 4Ah D Cell Ni-Cd LCV/4/zz LCV/5/zz 220-240 Volts AC - 50/60Hz 4.5 Watts 50Hz 200mA Nominal 24 hours 4 x 4Ah D Cell Ni-Cd 5 x 4Ah D Cell Ni-Cd LCV/6/zz 6 x 4Ah D Cell Ni-Cd Constant Voltage (CV) specified by part number zz available in range 8-27V Output in emergency operation is DC ± 5% 3 Watts 4 Watts 5 Watts 6 Watts 165mm x 45mm x 29mm FC =155mm Battery Size (Ni-Cd) LxWxH 220 x 37 x 37mm Fixing centres 205mm 280 x 37 x 37mm Fixing centres 265mm 340 x 37 x 37mm Fixing centres 325mm 2 sticks each 220 x 37 x 37mm Fixing centres 205mm Remote Box size LxWxH 340 x 90 x 40mm 340 x 90 x 40mm 395 x 90 x 40mm 375 x 150 x 50mm Tel +44 (0) 1708 372 223 Issue 1410 www.liteplan.com Fax +44 (0) 1708 371 345 Liteplan reserve the right to change colour, price or specification Page 3 of 3