* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download LOGO!Power 12
Power factor wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrification wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Stepper motor wikipedia , lookup
Electric power system wikipedia , lookup
Electrical ballast wikipedia , lookup
Audio power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical substation wikipedia , lookup
Power inverter wikipedia , lookup
Current source wikipedia , lookup
Power engineering wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power MOSFET wikipedia , lookup
History of electric power transmission wikipedia , lookup
Schmitt trigger wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Distribution management system wikipedia , lookup
Voltage regulator wikipedia , lookup
Surge protector wikipedia , lookup
Opto-isolator wikipedia , lookup
Power electronics wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
© Siemens AG 2008 LOGO!Power LOGO!Power 5 V ■ Overview ■ Application ■ Technical specifications Power supply, type 5 V/3 A 5 V/6.3 A Order No. 6EP1 311-1SH02 6EP1 311-1SH12 Input Rated voltage Vin rated Single-phase AC 100 - 240 V AC Wide-range input 85 ... 264 V AC Single-phase AC 100 - 240 V AC Wide-range input 85 ... 264 V AC Overvoltage resistance 2.3 x Vin rated/1.3 ms 2.3 x Vin rated/1.3 ms Mains buffering at Iout rated Rated line frequency, rated line-frequency range Rated current Iin rated Switch-on current limit (+25 °C) > 40 ms at Vin = 187 V 50/60 Hz, 47 ... 63 Hz > 40 ms at Vin = 187 V 50/60 Hz, 47 ... 63 Hz 0.36 ... 0.22 A < 15 A 0.71 ... 0.37 A < 30 A I 2t Built-in line-side fuse Recommended miniature circuit breaker (IEC 898) in the mains power input < 0.8 A2s Internal From 16 A, Characteristic B or from 10 A, Characteristic C < 3 A2s Internal From 16 A, Characteristic B or from 10 A, Characteristic C Output Rated voltage Vout rated Total tolerance, static • Static mains compensation • Static load smoothing Controlled, isolated DC voltage 5 V DC ±3 % Approx. 0.2 % Approx. 1.5 % Controlled, isolated DC voltage 5 V DC ±3 % Approx. 0.1 % Approx. 2 % Residual ripple Spikes (bandwidth approx. 20 MHz) Adjustment range Status display Response on activation/deactivation < 100 mVpp (typ. 10 mVpp) < 100 mVpp (typ. 30 mVpp) 4,6 ... 5,4 V Green LED for output voltage OK No overshoot of Vout (soft start) < 100 mVpp (typ. 15 mVpp) < 100 mVpp (typ. 30 mVpp) 4,6 ... 5,4 V Green LED for output voltage OK No overshoot of Vout (soft start) Startup delay/ voltage rise Rated current Iout rated Current range to +55 °C Parallel switching for enhanced performance < 0.5 s/typ. 15 ms < 0.5 s/typ. 10 ms 3A 0 ... 3 A Yes 6.3 A 0 ... 6.3 A Yes Voltage range 12 The power supplies of the LOGO!Power range are primary switched-mode devices that are optimally matched to the LOGO! logic modules in their functionality and design. With the wide-range input 85 V to 264 V AC, radio interference level B and option for installing in built-in miniature distribution boards, they can be used universally in a diverse range of applications in the low-end performance range. Continued on page 12/3. 12/2 Siemens KT 10.1 · 2008 © Siemens AG 2008 LOGO!Power LOGO!Power 5 V Power supply, type 5 V/3 A 5 V/6.3 A Order No. 6EP1 311-1SH02 6EP1 311-1SH12 Efficiency Efficiency at Vout rated, Iout rated Power losses at Vout rated, Iout rated Approx. 76 % Approx. 5 W Approx. 83 % Approx. 6 W <0.2 % Vout <0.2 % Vout Typ. ± 4 %Vout Typ. ± 6.5 %Vout Typ. 20 ms Typ. 20 ms Typ. 20 ms Typ. 20 ms Typ. 3.8 A Constant current characteristic <5A Typ. 8.2 A Constant current characteristic < 10 A – – Yes, safety extra-low output voltage Vout to EN 60950 and EN 50178 Class II (without protective conductor) Yes; CB scheme Yes, safety extra-low output voltage Vout to EN 60950 and EN 50178 Class II (without protective conductor) Yes; CB scheme Yes cULus-listed (UL 508, CSA C22.2 No. 14), File E197259; cURus-recognized (UL 60950, CSA C22.2 No. 60950), File E151273 Yes cULus-listed (UL 508, CSA C22.2 No. 14), File E197259; cURus-recognized (UL 60950, CSA C22.2 No. 60950), File E151273 Marine approval Degree of protection (EN 60529) Class I Div. 2, Group A, B, C, D, T4 GL IP20 Class I Div. 2, Group A, B, C, D, T4 GL IP20 EMC Emitted interference Supply-harmonics limitation Noise immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 Closed-loop control Dyn. mains compensation (Vin rated ± 15 %) Dynamic load smoothing (Iout: 10/90/10 %) Load step settling time • 10 to 90 % • 90 to 10 % Protection and monitoring Current limit Short-circuit protection Sustained short-circuit current rms value Overload/short-circuit indicator Safety Primary/secondary electrical isolation Protection class German Technical Inspectorate approval CE mark UL/cUL (CSA) approval FM approval Operating data Ambient temperature range – 20 ... +55 °C with natural convection Transport/storage temperature range – 40 ... +70 °C Humidity class Climate class 3K3 to EN 60721, no condensation Mechanics Supply-input connections L1, N Connections • Output + • Output – Dimensions (W x H x D) in mm Weight, approx. Installation – 20 ... +55 °C with natural convection – 40 ... +70 °C Climate class 3K3 to EN 60721, no condensation One screw terminal each for 0.5 ... 2.5 mm2 single-core/ finely stranded One screw terminal each for 0.5 ... 2.5 mm2 single-core/ finely stranded 2 screw terminals for 0.5 ... 2.5 mm2 2 screw terminals for 0.5 ... 2.5 mm2 54 x 90 x 55 0.17 kg Snaps onto DIN rail EN 60715 35x7.5/15 72 x 90 x 55 0.25 kg Snaps onto DIN rail EN 60715 35x7.5/15 12 Siemens KT 10.1 · 2008 12/3