* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download The Physics of Lightning
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power engineering wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Voltage optimisation wikipedia , lookup
Opto-isolator wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Earthing system wikipedia , lookup
Surge protector wikipedia , lookup
Stray voltage wikipedia , lookup
Overhead power line wikipedia , lookup
Single-wire earth return wikipedia , lookup
Alternating current wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical substation wikipedia , lookup
The Physics of Lightning Michael F. Stringfellow 2006 PQIG Workshop Introduction • • • • • • • • The Physics of Lightning: How lightning originates Leader propagation Strike mechanism The return stroke Subsequent strokes Channel multiplicity Lightning flash density Lightning interaction with overhead power lines 2006 PQIG Workshop The Thundercloud 2006 PQIG Workshop How Lightning Starts •Lightning starts in cloud – Around 0°C - that’s typically 15,000 ft above ground – Breakdown starts in high-field region – Branching discharge moves up and down 2006 PQIG Workshop + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + - Leader Propagation •Ground flashes almost always start with downward (usually) stepped leader from high charge region •Steps 10-100 m long •Pauses between steps •Lowers charge to earth • Negative in > 95% of ground flashes 2006 PQIG Workshop B r e a k d o w n z o n e - - -- - - Connecting Leaders •Launched upward by electric field of stepped leader as it approaches earth •Occur at many locations near descending flash •Most are unsuccessful •One or more connect with downward leader to provide final channel to earth •Not often seen, but frequently heard 2006 PQIG Workshop --- -- + + + + + + Connecting Leaders 2006 PQIG Workshop Return Stroke •Large current impulse flows to ground •Large electromagnetic pulse radiated •Leader charge neutralized 2006 PQIG Workshop VHF Radio Picture - First Stroke 2006 PQIG Workshop Subsequent Strokes •"Dart" leaders launched from cloud •Follow path of first return stroke •Tap new cloud charges •Cause subsequent return strokes •Often depart from old path 2006 PQIG Workshop VHF Radio Picture Subsequent Stroke 2006 PQIG Workshop Video Stills of Multi-Stroke Flash 2006 PQIG Workshop Multiple Stroke Flashes •Typically 2-4 strokes per flash •Stroke intervals 5 -100 milliseconds •Reach ground at 1 to 5 points •Severe flashes have >4 strokes •Continuing currents likely 2006 PQIG Workshop Multiple Ground Channels •Multiple ground channels are common • Root branching • Simultaneous leader branches • Successive strokes may depart from "main" channel •Three major channels for every two flashes 2006 PQIG Workshop Multiple Ground Channels 2006 PQIG Workshop Currents & Voltages •Cloud charging current a few amps •Cloud voltages 50 MV to 500 MV •Leader currents 10 A to 1000 A •Return stroke currents 5kA to 500 kA – Approximately lognormal distribution with 30 kA to 40 kA median 2006 PQIG Workshop Retu r K ilo a mp 1 2 0 1 0 0 8 0 6 0 4 0 2 0 0 0 5 1 0 1 0 2 5 0 2 0 0 3 5 0 0 M ic r o Electricity Production, Transmission & Distribution PRODUCTION MEDIUM VOLTAGE TRANSMISSION EXTRA HIGH VOLTAGE 345-765 kV HIGH VOLTAGE 115-230kV DISTRIBUTION MEDIUM VOLTAGE 24-69kV LOW VOLTAGE 120-600V 1 TIE-LINE 2 HEAVY INDUSTRIAL USER MEDIUM INDUSTRIAL USER SUBSTATIONS TRANSMISSION SMALL INDUSTRIAL TRANSMISSION SUBSTATIONS COMMERCIAL RESIDENTIAL POWER INTERCONNECTING DISTRIBUTION PLANTS SUBSTATIONS SUBSTATIONS 2006 PQIG Workshop Lightning and Overhead Lines • Direct strikes affect all voltage systems – Problems decrease with insulation level – Flashover when lightning strikes phase conductor – Also back flashover when tower or shield wire struck • Indirect strikes affect distribution and sub-transmission systems – Induced voltages up to 300 kV 2006 PQIG Workshop Striking Distance •Major influences – Height of structure – Charge on lightning leader – Slenderness of structure – Random effects " Q " e g r a h C " I " t n e r r u -C - g n i k i r t S e c n a t s i D " H " t h g i e H e r u t p a C s u i d a R " c R " 2006 PQIG Workshop Striking Distance •Can be inferred from photographs – Point of last downward branch – Upward connecting leader path – Apparent junction 2006 PQIG Workshop Voltages from Direct Strikes to Overhead Lines • Stroke to conductor – Conductor has surge impedance of about 400 ohms – Average return stroke current 30 kA – Conductor voltage = 400 x 15,000 V = 6 MV • Stroke to tower – Tower has footing resistance of 30 ohms – Tower voltage = 30 x 30,000 V = 900 kV • Shielding and grounding provide effective protection – Especially for higher voltage systems 2006 PQIG Workshop Transmission Lines & Lightning •Characteristics – Shielded construction – High insulation levels – Good tower grounding – Effective protection • Well coordinated fast switchgear •Result – Excellent lightning performance – Permanent damage rare – Few flashovers quickly cleared by protection 2006 PQIG Workshop Shielding Effectiveness 2006 PQIG Workshop Shielding Failure •Likely low current strokes – Less leader charge – Smaller striking distance – Flashover less probable 2006 PQIG Workshop Distribution Lines & Lightning •Characteristics – Unshielded construction – Low insulation levels – Poor pole grounding – Less effective protection • Slower switchgear, autoreclosers and fuses •Result – Poor lightning performance – Permanent damage common – Many flashovers cleared • Some may take several shots – Nuisance fuse blowing – Many sags and short-duration outages 2006 PQIG Workshop Voltages from Indirect Lightning Strikes Number per Year 1000 100 10 1 10 100 Induced Voltage kV 2006 PQIG Workshop 1000 Induced Voltage Flashover 2006 PQIG Workshop Lightning Transients on AC Power System 2006 PQIG Workshop Lightning Transients on AC Power System 2006 PQIG Workshop Some Power System Lightning Problems Multi-stroke flashes can stress switchgear – Transients occur when open Multi-channel flashes can defeat system protection – Simultaneous faults occur on different parts of circuit Frequent strikes in severe storm can overwhelm protection “Weak-link” structures will flash over frequently – May limit line performance 2006 PQIG Workshop Lightning Tracking •Radio location used to locate lightning – Real time • Storm warning • Allocation of resources – Archival data • Lightning flash density • Fault investigations 2006 PQIG Workshop Lightning Incident Investigation 2006 PQIG Workshop US Flash Density 2006 PQIG Workshop Ground Flash Density • Highest in southeast & Gulf coast USA • Tampa bay 60 per square mile per year • Houston 40 per square mile per year • Lower as you move north and west • Washington & Alaska < 0.1 per square mile per year • Phoenix area ~10 per square mile per year • Highly variable from year to year • Lightning “hot spots” or “lightning nests” 2006 PQIG Workshop Lightning Hot Spots • Local areas of high lightning incidence • Appear over several years’ recording • Important to ignore short-term random variations • May reflect surface features that steer or promote storms • Mountains & rivers • Cities • Industries • May be useful for line performance improvements • Shielding • Arresters • Enhanced grounding 2006 PQIG Workshop Phoenix Lightning Ground Flash Density 2006 PQIG Workshop Summary • Overhead transmission lines are resistant to lightning – Shielded, grounded, high insulation levels – EHV systems are almost immune • Electricity distribution systems are vulnerable – Unshielded, poorly grounded, low insulation levels – Some newly discovered challenges from multichannel flashes • Lightning location systems have many benefits – Real-time tracking – Archival flash density 2006 PQIG Workshop