* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Cardiac Arrhythmias in thalassaemia
Coronary artery disease wikipedia , lookup
Management of acute coronary syndrome wikipedia , lookup
Cardiac contractility modulation wikipedia , lookup
Myocardial infarction wikipedia , lookup
Electrocardiography wikipedia , lookup
Quantium Medical Cardiac Output wikipedia , lookup
Arrhythmogenic right ventricular dysplasia wikipedia , lookup
Cardiac Arrhythmia in Thalassaemia Limassol, 24 – 26 October 2012 Malcolm Walker University College and the Heart Hospitals, London Clinical Director Hatter Cardiovascular Institute Cardiac Arrhythmias in thalassaemia • Plan of talk 1. 2. 3. 4. 5. Historical aspects Relationship to iron overload Clinical Management: Principles & Investigation Specific arrhythmia Technology: Ablation & Devices Malcolm Walker TIF 2012 Cardiac Arrhythmia in thalassaemia 1. Historical aspects Malcolm Walker TIF 2012 History: incidence of arrhythmia & ECG changes thalassaemia, transfused but not chelated Age Normal ECG % LV hypertrophy % Rhythm abnormality % Heart block % 5-10 67 33 6 6 11-15 39 28 44 6 16-20 30 40 50 40 21-30 12 62 19 19 TOTAL 39 40 27 14 Malcolm Walker TIF 2012 Adapted from Ehlers et al 1980 Cardiac Arrhythmia in thalassaemia 2. Relationship to iron overload Malcolm Walker TIF 2012 Arrhythmia and myocardial iron assessed by cMR T2* ● 652 patients with b-thalassaemia ● Mean age 27 yr ● Excluded those with heart failure (HF) at first scan Malcolm Walker TIF 2012 Arrhythmia and myocardial iron assessed by cMR T2* Threshold for arrhythmia T2*<20ms Types & frequency: ● AF 78 (12%) ● SVT 14 (2%) ● VT 5 (<1%) ● VF 1 MIOT study group: gender differences Italian MIOT Cohort 25 Frequency % 20 p=0.14 15 10 5 W M en LV D ys fu om nc tio en n LV D ys fu nc tio n M en ar rh yt hm W om ia en ar rh yt hm ia 0 Adapted from: Marsella et.al. Haematologica 2011; 96: 515 Malcolm Walker TIF 2012 MIOT study group: T2* and cardiac arrhythmia Adapted from: Marsella et.al. Haematologica 2011; 96: 515 Malcolm Walker TIF 2012 Arrhythmia and myocardial iron assessed by cMR T2* Conclusions •Incidence of arrhythmia very low in this Italian cohort •25 out of 776 patients (3.2%); compared to overall 15% incidence in 1 year (UK cohort; Kirk et al 2009) •No statistical relationship with heart iron by T2* in Italian group; clear cut risk associated with T2* in UK cohort (Kirk et al 2009) Arrhythmia and myocardial iron assessed by cMR T2* Reasons for differences between Italian and UK patients? •Italian cohort more recent •Overall lower T2*; very few patients with T2* < 20 ms •More patients on combination Rx (DFO + DFP) AF in thalassaemia major – UCH clinic • 80 consecutive clinic attenders 2011-2012 Mean age 38 yr; 51% female AF current History of AF or pAF DM Thyroid Hep C (ever) Heart failure in last 12 months Malcolm Walker TIF 2012 8.75% 33.7% 48.7% 22.0% 15.0% 10.0% AF in thalassaemia – UCH clinic % incidence 55 11 10 Heart iron load by current cMR T2* Malcolm Walker TIF 2012 AF in thalassaemia – UCH clinic Relationship between iron load & AF Reasons for differences between Italian and UK patients? T2* ms P < 0.05 Walker et al unpublished observations Range 5 to 13 yr ago AF in thalassaemia – UCH clinic Relationship between iron load & AF Reasons for differences between Italian and UK patients? T2* ms P < 0.05 •Atrial fibrillation (AF) occurs late in life and reflects past history, not current iron status Walker et al unpublished observations Range 5 to 13 yr ago AF in thalassaemia – UCH clinic Risk factors for AF Diabetes link 71% of those in AF now have DM 69% of those with a history or pAF have DM LA size (by area by ECHO – cMR volumes awaited) No clear correlation with AF Current LV function (systolic, by EF) No clear correlation with AF Correlation with previous episode of LV dysfunction Malcolm Walker TIF 2012 Cardiac Arrhythmia in thalassaemia 3. Clinical Management principles & investigation Malcolm Walker TIF 2012 Clinical aspects of arrhythmia in thalassaemia • Symptoms Palpitation Breathlessness Dizziness or near fainting Collapse • There is a mismatch between symptoms & severity of arrhythmia • “Trivial” problems may cause immense anxiety • Potentially severe arrhythmia may cause only minor complaints (or no symptoms) Malcolm Walker TIF 2012 Clinical aspects of arrhythmia in thalassaemia • Symptoms Palpitation Breathlessness Dizziness or near fainting Collapse Near fainting, loss of consciousness or collapse Always need to be taken very seriously Malcolm Walker TIF 2012 Clinical aspects of arrhythmia in thalassaemia • Management requires 1. Diagnosis of the arrhythmia causing the symptoms ECG Holter ambulatory monitor – 24 hr or longer • Techniques which may be useful Malcolm Walker TIF 2012 Implantable loop recorder – “Reveal” device Analysis of repolarisation (QT and JT dispersion) Electrophysiology study Clinical aspects of arrhythmia in thalassaemia – the clinic ECG Supraventricular tachycardia SVT Atrial Fibrillation AF Ventricular ectopic VE Malcolm Walker TIF 2012 Clinical aspects of arrhythmia in thalassaemia • Management requires 1. Diagnosis of the arrhythmia causing the symptoms ECG Holter ambulatory monitor – 24 hr or longer Event recorders • Techniques which may be useful Malcolm Walker TIF 2012 Implantable loop recorder – “Reveal” device Clinical aspects of arrhythmia in thalassaemia – the Holter 24hr ECG Holter 24 hr ECG Patient aged 27 yr Symptom: palpitation + dizziness Shows Ventricular tachycardia VT Malcolm Walker TIF 2012 Holter ambulatory ECG screening • Holter screening failed to predict 2 patients •Significant arrhythmia detected in 15% patients (n=4) •Holter screening failed to predict 2 patients who went on to have significant arrhythmia •30% of the patients with a normal Holter had symptoms •CONCLUSION •Routine screening of TM population with Holter not sensitive nor specific •Need to consider newer technologies – event recorders, ILR Malcolm Walker TIF 2012 From Qureshi et al. Annals NY Acad Sci 2005 Clinical aspects of arrhythmia in thalassaemia • Management requires 1. Diagnosis of the arrhythmia causing the symptoms ECG Holter ambulatory monitor – 24 hr or longer Event recorders • Techniques which may be useful Malcolm Walker TIF 2012 Implantable loop recorder – “Reveal” device Clinical aspects of arrhythmia in thalassaemia • Management requires 1. Diagnosis However, making the ECG diagnosis is not enough on its own • Importance of the arrhythmia depends critically on knowledge of the underlying cardiac status 1. 2. 3. Malcolm Walker TIF 2012 Ventricular function; structural heart defects Iron burden (cMR T2*) Pro-thrombotic tendency Clinical aspects of arrhythmia in thalassaemia • Management requires 1. Precise diagnosis 2. Knowledge of underlying cardiac status Ventricular function & cardiac structure by ECHO Iron burden (T2*) by cMR An ECHO + cMR are URGENT when 1 2 3 Malcolm Walker TIF 2012 Ventricular arrhythmia Poorly tolerated AF Symptoms include loss of consciousness/ collapse/ heart failure Clinical aspects of arrhythmia in thalassaemia - conclusions • ECG Necessary baseline at least every 12/12 At every cardiovascular assessment It tells us more about the heart than just arrhythmia • Holter 24hr ECG Useful to investigate symptoms Poor as a screening tool in asymptomatic well chelated TM patients with good LV function Malcolm Walker TIF 2012 Cardiac Arrhythmia in thalassaemia 4. Specific arrhythmia VT AF Malcolm Walker TIF 2012 Specific arrhythmia Tachycardia – ventricular (VT) • Ventricular tachycardia (VT) or broad complex tachycardia Malcolm Walker TIF 2012 Specific arrhythmia Tachycardia – ventricular (VT) • Ventricular tachycardia (VT) or broad complex tachycardia This is a medical emergency Input of emergency physicians/ cardiologists Immediate cardioversion if in collapse or shock It always complicates severe iron overload It may respond to iv chelation with DFO iv DFO must be started immediately Combination treatment may be indicated Malcolm Walker TIF 2012 Specific arrhythmia Tachycardia – ventricular (VT) • Ventricular tachycardia (VT) or broad complex tachycardia Once acute event controlled Consider implantation of ICD Poor LV function not improving with iv chelation VT occurs without high iron overload – look for another cause! ICD must be MRI compatible Malcolm Walker TIF 2012 Specific arrhythmia Atrial Fibrillation AF • AF: the commonest arrhythmia Paroxysmal Persistent Permanent Malcolm Walker TIF 2012 Specific arrhythmia: Atrial Fibrillation Risk to patient: Heart Failure 1 Cardiac decompensation/ overt heart failure Most likely when AF first appears - when heart rate is high Target treatment to: 1. 2. Control rate Restore normal sinus rhythm Check, urgently if significant heart failure signs: 1. 2. 3. Malcolm Walker TIF 2012 LV function by ECHO Cardiac iron status by cMR T2* Thyroid function etc. Specific arrhythmia: Atrial Fibrillation Risk to patient: Stroke 2 Stroke risk depends critically on: Prothrombotic status Structural heart disease Impaired LV Higher risk if AF is persistent or permanent or frequent paroxysms of more than 12 hr duration 1. 2. Check 1. Malcolm Walker TIF 2012 Restore normal sinus rhythm where possible Anti-coagulation with warfarin (INR 2.5) or new agents Cardiac ECHO for LA size, LV function, valve disease Specific arrhythmia AF – special circumstances 1. 2. 3. 4. Complicating cardiac failure Precipitating cardiac failure In iron loaded TM with good LV function In non iron loaded TM with good function Malcolm Walker TIF 2012 Specific arrhythmia AF – special circumstances 1. Complicating cardiac failure 2. Precipitating cardiac failure These are urgent situations requiring admission 1. Consider TOE guided DC Cardioversion 2. Itensify Rx: iv DFO: 24r x 7 days plus DFP (?) 3. Conventional long term management: aim to prevent further attacks 1. 2. 3. Malcolm Walker TIF 2012 Betablockers Amiodarone (short to medium term) Anticoagulation Specific arrhythmia AF – special circumstances 3. In iron loaded TM with good LV function 4. In non iron loaded TM with good function These are non-urgent situations requiring 1. Consider TOE guided DC Cardioversion after 4 weeks anticoagulation 2. Itensify chelation Rx: if iron overloaded 3. Conventional rate & rhythm control 1. 2. Betablockers Rate lowering calcium channel blockers 4. Anticoagulation with warfarin or new agents Malcolm Walker TIF 2012 Specific arrhythmia AF – long term prevention strategy • Long term prevention strategies of AF Medication: generally poor at long term prevention Effective drugs potentially too toxic (Amiodarone) Less toxic drugs often less effective (Beta-block, Flecainide) Thalassaemia population may have an advantage, if AF complicates iron overload. Removing iron may effectively prevent AF for many years (?) Consider ablation and other therapies Malcolm Walker TIF 2012 Catheter based ablation for AF • Cardiac catheter based techniques • Complex & time consuming (2 to 4hr) • Often GA required • Specialist EP cardiologists & service • Success rates 70 to 80% • Recurrence rates approx 15% at 1 year • Risk of Stroke, cardiac perforation 1% to 2% Complications and success rates may be different for thalassaemia population Catheter based ablation for AF Malcolm Walker TIF 2012 Catheter based ablation for AF Malcolm Walker TIF 2012 Catheter based ablation for AF • Rhythm control by ablation General success rates 70% to 80% “cure” 15% need second ablation • In TM population Experience is young Anecdotal evidence of much higher recurrence rates Malcolm Walker TIF 2012 AF: Interventional techniques to reduce stroke risk • Left atrial appendage occluder Catheter based technique Reduces risk of stroke • Structural defect closure Patent foramen ovale (PFO) closure If patient has strong pro-thrombotic tendency Malcolm Walker TIF 2012 Bradycardia & heart block in thalassaemia • Complete heart block common in the past is rare today Malcolm Walker TIF 2012 Bradycardia & heart block in thalassaemia • Complete heart block is rare • Mandates the use of a pacemaker Historically this would prevent the use of cMR forever! Malcolm Walker TIF 2012 “Patients and the implanting community deserve nothing less than devices that are safe by design and not by chance.” – J. Rod Gimbel, MD, FACC Emanuel Kanal, MD, FACR For more information visit: http://www.medtronic.com/mrisurescan/ Malcolm Walker TIF 2012 4 chambers LA RA Lead Signal alteration Malcolm Walker TIF 2012 LV RV cMR safe pacemakers Malcolm Walker TIF 2012 Arrhythmia and thalassaemia Conclusions • Complex pathophysiology, which may be changing as TM population ages • Practical management issues largely revolve around intensified chelation, as this may control problem • Role of EP techniques needs to be fully defined • Devices need to be cMR compatible Malcolm Walker TIF 2012