* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ABR1E301M - Schneider Electric
Fault tolerance wikipedia , lookup
Electrical ballast wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Peak programme meter wikipedia , lookup
Current source wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Ignition system wikipedia , lookup
Voltage optimisation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Earthing system wikipedia , lookup
Voltage regulator wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
Electrical substation wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
Sound level meter wikipedia , lookup
ABR1E301M Product data sheet Characteristics Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications input interface module - 17.5 mm electromechanical - 230/240 V AC - 1 C/O Main Range of product Interface for discrete signals Product or component type Electromechanical input interface module Contacts type and composition 1 C/O [Uc] control circuit voltage 230...240 V Control circuit type AC Control circuit frequency 50/60 Hz Width pitch dimension 17.5 mm [In] rated current <= 5.5 mA AC Reverse polarity protection Without Short circuit protection 16 A external fuse gF (Ik <= 2.5 kA AC and Ik <= 100 A DC) 16 A external fuse gG (Ik <= 2.5 kA AC and Ik <= 100 A DC) [Ith] conventional free air thermal current 2 A conforming to IEC 60947-1 Local signalling Green mechanical indicator for position of contacts and 1 green LED control signal state Complementary Control circuit voltage limits 264 V energization threshold: 164 V Housing colour Grey Connections - terminals Screw clamp terminal Drop-out voltage <= 78 V Holding current >= 1.5 mA AC Power dissipation in W <= 1.5 W Maximum switching voltage 125 V DC 252 V AC [Ue] rated operational voltage <= 125 V DC conforming to IEC 60947-5-1 <= 230 V AC conforming to IEC 60947-5-1 Network frequency 50/60 Hz [Ie] rated operational current 1 A AC-13 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1 1 A AC-14 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1 Jun 17, 2017 1 1 A AC-15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1 1 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1 2 A AC-12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1 2 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1 Minimum switching current 3 mA Minimum switching voltage 17 V Electrical reliability <= 0.00000001 Operating time <= 12 ms between de-energisation of coil and closing of NC contact <= 12 ms between de-energisation of coil and closing of NO contact <= 12 ms between energisation of coil and closing of NC contact <= 12 ms between energisation of coil and closing of NO contact Contact bounce time <= 3 ms Operating rate in Hz <= 6 Hz at no-load <= 0.5 Hz at Ie Mechanical durability >= 10000000 cycles [Ui] rated insulation voltage 250 V conforming to IEC 60947-1 250 V conforming to VDE 0110 group C Flame retardance V0 conforming to UL 94 Cable cross section 0.27...4 mm², 1 wire rigid 0.34...2.5 mm², 1 or 2 wires flexible with cable end 0.6...2.5 mm², 1 or 2 wires flexible without cable end 0.27...2.5 mm², 2 wires rigid Operating position Any position Installation category II conforming to IEC 60947-1 Mounting support Symmetrical DIN rail Combination rail Asymmetrical DIN rail Product weight 0.09 kg Environment Immunity to microbreaks 6 ms Dielectric strength 1500 V between independent contacts 2500 V between wired interface and earth 4000 V between coil circuit and contact circuits Standards IEC 60947-5-1 Product certifications DNV UL BV LROS (Lloyds register of shipping) CSA IP degree of protection IP20 conforming to IEC 60529 Protective treatment TC Fire resistance 850 °C conforming to IEC 60695-2-1 Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27 Vibration resistance 6 gn (f = 10...55 Hz) conforming to IEC 60068-2-6 Electromagnetic compatibility 1.2/50 ms shock waves immunity test, 0.25 kV for U > 50 V conforming to IEC 255-4 1.2/50 ms shock waves immunity test, 0.5 kV for U < 50 V conforming to IEC 255-4 Electrostatic discharge immunity test level 3, 8 kV conforming to IEC 61000-4-2 Rapid transients immunity test, on input/output 1 kV conforming to IEC 61000-4-4 Rapid transients immunity test, on power supply 2 kV conforming to IEC 61000-4-4 Ambient air temperature for operation -20...60 °C at Un -5...40 °C unrestricted operation Ambient air temperature for storage -40...70 °C Operating altitude <= 3000 m Pollution degree 3 conforming to IEC 60947-5-1 Contractual warranty Warranty period 2 18 months Product data sheet Dimensions Drawings ABR1E301M Electromechanical Interface Module Dimensions 3 Product data sheet Connections and Schema Electromechanical Interface Module Example of Application with PLC Interfacing PLC discrete inputs S1, S2Pushbuttons series contacts (1) 2-wire sensors (2) PLC positive logic discrete inputs (3) 3-wire sensors 4 ABR1E301M Product data sheet Connections and Schema ABR1E301M Interface with Mechanical Indication Circuit Diagram 1 C/O 5