* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Insulation monitor - GMWISO 1.05
Pulse-width modulation wikipedia , lookup
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electric machine wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrification wikipedia , lookup
Voltage optimisation wikipedia , lookup
Ground (electricity) wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power electronics wikipedia , lookup
Voltage regulator wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Surge protector wikipedia , lookup
Electrical substation wikipedia , lookup
Buck converter wikipedia , lookup
Stage monitor system wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
Stray voltage wikipedia , lookup
Portable appliance testing wikipedia , lookup
Distribution management system wikipedia , lookup
Studio monitor wikipedia , lookup
Earthing system wikipedia , lookup
Insulation monitor - GMWISO 1.05 Insulation monitor - GMWISO 1.05 GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 1 Insulation monitor - GMWISO 1.05 Copyright No part of this Operation Manual may be reproduced, published or transmitted in any form or by any means without the express permission of Generator-Technik Schwäbisch Gmünd GmbH &Co. KG. © 2001 Generator-Technik Schwäbisch Gmünd GmbH & Co. KG. All rights reserved. General information Technical modifications after date of printing are not considered. Subject to change without notice. Issue date: August 2001 Manufacturer's address For any information and support concerning technical problems, services and orders please contact us. Generator-Technik Schwäbisch Gmünd GmbH & Co. KG Ziegelfeldstraße 18 D-73563 Mögglingen Telefon +49 7174 89 80 0 0 Telefax +49 7174 89 80 0 25 www.gts-generator.com [email protected] 2 GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 Insulation monitor - GMWISO 1.05 Conception GMWISO insulation monitors are insulation monitoring modules taking especially into account the increased safety need and the current regulations for portable, combustion?engined stand?by electricpower units. Ungrounded, portable stand-by electric-power units with the optimum system of protection "Fuse disconneetion with insulation monitoring and cut-off" realised with the GMWISO insulation monitor may also be commissioned by non-electricians and be operated in areas with an increased threat to persons (for ex. damp areas). Several consumers may be connected to the stand-by electric-power generator at the same time. A "built" and measured grounding device is not necessary. Extensive electricity distribution supply networks are admissible. GMWISO insulation monitors have been developed especially for the difficult operating conditions in the case of direct mounting to portable stand-by electricpower generators. GMWISO insulation monitors can be supplied as individual modules for OEMs to be integrated into newly-designed electric-power generators and as retrofitting kit for generators already available on the market. Product description The GMWISO insulation monitors serve for the insulation monitoring in ungrounded A.C. networks (as well as chained threephase networks in star connection) of portable stand?by electric-power generators. With GMWISO insulation monitors, it is easy to generate electric-power generators according to regulations (for ex. GW308, VDE1) 0100.728) with little time needed for assembly and wiring. The distribution supply network of the stand-by electric-power generator may include pure A.C. consumers as well as non-electrically separated, D.C. fed devices (for ex. frequency converter, threephase to single-phase rotary welding converter, D.C. operated solenoid valves and brakes etc.). Spurious releases due to devices with D.C. components connected to the generator are largely impossible because of the new circuit technology with automatic sign-dependant sensitivity adaptation. It must, however, be taken into account that faulty insulation on the D.C. side can lead to a release, but with diverging sensitivity. The threshold value indicated for the devices for faulty insulation is valid for faults in the A.C. network. In the Technical Data of the GMWISO insulation monitors you flind a typical threshold value indicated for a faulty insulation on the D.C. side of the connected devices. The indications are valid for the D.C. circuits used mostly. Regarding the threshold value and the behaviour during switch-off time GMWISO insulation monitors have been matched with the valid regulations and are fail-safe. The stand-by electric-power units must be built according to DIN 6280, part 10, and on the altemator side laid out according to VDE 0530. They must be laid out and tested for the network structure (IT network) provided for in VDE 0100, part 728/ 4.2.2. with the method 4.2.4.2.1. 1) *VDE = German Electric Engineers Regulations GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 3 Insulation monitor - GMWISO 1.05 The devices GMWISO insulation monitor have been realised in SMD technology, without transforrners or relays. They have been encapsulated entirely in a fully insulated, moisture-proof housing, resistant to vibration and therefore also suitable for a direct mounting to generators with diesel engines. GMWISO insulation monitors can be used with an extended, admissible distribution voltage range / frequency range (with respect to VDE 0413.2/1.73) and in a temperature range which is practical for generators. The distribution voltage of the GMWISO insulation monitor is drawn directly from the output voltage of the generator's network to be monitored. A D.C. voltage is used as measuring voltage, which constantly measures the insulating resistance between the altemator output circuit/load circuit and PE. When the set threshold value for the insulating resistance has been reached (or the value gets below the threshold value), the extemal load current release/remote release of the load circuit switch is triggered. lf the insulating resistance of all active components has deereased below 100 Ω/V (i.e. 23 kΩ LI, N/PE) with respect to the equipotential bonding conductor (PE) or (with an existing grounding) with respect to the earth potential (:), all consumers are switched off immediately. A signal lamp connected in parallel to the load current release displays the insulating error (error display memory) until the GMWISO insulation monitor is reset. In order to reset the GMWISO insulation monitor when an insulating error has occurred or when the test button has been pressed, switch off the distribution voltage for at least 2 seconds (for example by stopping the stand-by electricpower intemal combustion engine). Safety information The function and reliability of the safety measure "Fuse disconnection with insulation monitoring and all-polo cut-off" is particularly important for personal protection and stand-by electric-power generators in the case of a rushed operation by "non electricians". Therefore the compliance with the following safety information is very irnportant. − For the equipment with or retrofitting of GMWISO insulation monitors only generators which meet the relevant rules (particularly DIN/VDE 0100, part 728, DIN/VDE 0530, DIN 6280, part 10) are suitable. − Generators with a high system of protection (at least IP 44) are to be preferred, because they cause less problems due to reduced insulating values (contamination, humidity in the machine). The minimum requirement for the system of protection for generators according to DIN 6280, part 10 is the reliable compliance with the system of protection IP 23 according to DIN 40050. − If commercial stand-by electric-power generators or generators already in operation are to be retrofit with GMWISO insulation monitors, the insulating resistance/electric strength of the output winding(s) must be measured before the GMWISO insulation monitor is installed. Only if the measured insulating values ($5 MΩ-:/Umeas= 500 V DC) and the electric strength (UM= 2500 V/50 Hz-:) 4 GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 Insulation monitor - GMWISO 1.05 according to DIN 62 80T.10§5.7.1.1 are met the generator is suitable for retrofitting. − GMWISO insulation monitors have been conceived for altemators with a largely sinusoidal output voltage. lf altemators with a high relative harmonic content or very asymmetric courses of the curves are used, an influence on the response level is possible. In such cases the usability must be checked before the use. − Altemators with speeial voltages or special frequencies cannot be equipped with GMWISO insulation monitors. See also "Technical Data GMWISO 1.05". − lf the altemator has got several electrically separated output windings, for each output circuit an individual insulation monitoring must be carried out. It is usually not allowed to use combined welding electric power generators with nonelectrically separated welding winding or generators with load winding tap within the scope of the VDE rules. − The installation, the ftmctional test and the first commissioning of stand-by electric-power generators retrofit with GMWISO insulation monitors may only be carried out by an electrician. − GMWISO insulation monitors must be installed carefully (particular attention must be paid to abrasion when the connecting lines are installed) and the correct connection must be tested before the commissioning. A wrong connection may lead to the destruction of the GMWISO insulation monitor! − The functional test during the first commissioning should be carried out with an extemal test resistance (Rtest = 22 kΩ/tol.: ± 5 %/at least 5W). For this all live connections of all sockets (including a possible neutral wire) must be connected briefly − one after the other − with the PE via the resistance. In all cases the cut-off must be effected after max. 1 s. − In connection with GMWISO insulation monitors it is only allowed to use load current releases remote releases approved by GMW. − Only VDE tested devices with approval for a direct connection to the stand-by electric-power generator network are admissible for the extemal test button and signal lamp. When selecting these components, for the accommodation of the components and regarding the power switch, the system of protection required for the switch box of the generator must be complied with. Only signal lamps which are resistant to vibration (glow lamp or LED) should be used. − Before the stand-by electric-power generator is handed over to the client, he must be informed about the particular features and the operation of the generator with the system of protection "potential segregation with insulation monitoring and cut-off". − The supplied test protocol must be handed over to the client of the stand-by electric-power generator (completely filled in) together with the brief operator's guide, as a supplement to the Operator's Guide. GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 5 Insulation monitor - GMWISO 1.05 − Before insulation or voltage tests are carried out at the stand-by electric-power generators (for example in the case of high-voltage tests/earth contact tests) or at parts of the installation, the GMWISO insulation monitor must be separated from the generator and all parts of the installation for the duration of the test. − In each electrically connected distribution system only one insulation monitor may be connected (i. e. in the case of an insulation monitoring with GMWISO insulation monitor at the generator, socalled "Solid-rubber distributors" or similar with insulation monitor are not admissible!) because insulation monitors can have an influence on each other. − It is possible to connect D.C. powered devices (solenoid valves, brakes, converters etc.) in the network of the stand-by electric-power generator to be monitored. It must be taken into account, however, that faulty insulation in the D.C. circuit is registered with an increased sensitivity in both current directions. − Distributions and devices with built-in residual current operated devices are not fail-safe with ungrounded, portable stand-by electric-power generators (due to the missing grounding installation/potential segregation), but they are not necessary when the system of protection "potential segregation with insulation monitoring and cut-off" is used. − If the GMWISO insulation monitor is used within the scope of GW308 a brief operator's guide for the insulation monitoring must be attached at the stand-by electric-power generator pointing out the daily functional test. − Further inforination and regulations for the use of generators with the system of protection "Fuse disconnection with insulation monitoring and cut-off" can be found in VDE 0 100, part 728 and GW 308. − Additional provisions or regulations limiting the operation of the generator in the case of particular operating conditions (for ex. rules for prevention of accidents/ VBG, VDE 0706, conditions by the (German) employer's liability insurance association or similar) must be taken into account. 6 GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 Insulation monitor - GMWISO 1.05 Warnings and informations on generatots with GMWISO Since the stand-by electric-power generators equipped with the system of protection "Fuse disconnection with insulation monitoring and cut-off" have mainly been conceived for the use by non-electricians, it must be possible for all users of the stand-by electric-power generator to safely operate the stand-by electric-power generator and to test the additional safety measure against direct contact. Both must be identified at the device. At least the following instructions must be attached visibly and permanently to the electric-power generator. COMMENT: Depending on the electric-power generator or its purpose, it might be necessary to attach or enclose further instructions. The exemplary text refers to the operation of the GMW-SYNCHRO stand-by electric-power generator. Short operator's guide/information − Used safety measure: "Fuse disconnection with insulation monitoring and all-polo Cut-off". − This device can be operated without grounding. − The following tests must be carried out daily with the motor running: 1. Unplug all devices; open the cover; safety switch in position "ON", 2. press the test button, 3. check whether the safety switch has triggered and the signal lainp has been activated, 4. stop the electric?power generator, 5. safety switch in position "ON", close the cover. − NOTICE: The electric-power generator may only be used if the safety switch triggered during the test. − The total length of all lines connected to the electric-power generator mustnt exceed 250 m. − If several stand-by electric-power generators are used or if the general network is also available, the networks mustn't be connected to each other. − Corrective maintenance at the electrical components of the stand-by electric power generator and at the electric equipment may only be carried out by electricians. − For further safety and operating inforination, please refer to the Operator's Guide and the relevant regulations. GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 7 Insulation monitor - GMWISO 1.05 Technische Daten Nominal supply voltage (supply/voltage/output) Operating area UN AC 230 V 0.7..1.2 x UN Nominal supply frequency (V./M./A.) fN Operating area 50 Hz 35 Hz..65 Hz Own consumption P 0.5 VA typ. Operating time/Operating mode ED 100 %/S1=DB (duty cycle) Measuring D.C. voltage (RISO 6 4) UM Holding wire current (at RISO=23 kΩ) I M Leakage holding-wire current (RISO=0) I MK DC 11 V DC 125 µA DC 165 µA D.C. internal resistance Impedance (at 50 Hz) 80 kΩ 100 kΩ RI ZI Max. admissible external D.C. voltage Max. admissible test voltage (1s) UN x 2.4 AC 1500 V Threshold value (static i. e. tA 6 4 = VDE 0413T2/$6.1.1.) U1, U2 or L1, N/PE (:) RISO 30 kΩ ± 15 % L2, L3/PE (:) RISO 40 kΩ ± 15 % response lag (sudden modification tAmax RISO 6 4 9 RISO # 23 kΩ = 100 kΩ/V Kriterium VDE 01000T728/§4.2.4.2.1) <1s Example Threshold value in the case of faulty insulation/: behind rectifiers E1 (L1, N) RISO 100 kΩ ± 25 % (examples) B2 (L1, N) RISO 125 kΩ ± 25 % M3, B6 RISO 400 kΩ ± 25 % Output for automatically switching load current releases/remote releases Output current max. AC 1A (semiconductor output TRIAC ch.) to connection (2) Admissible ambient temperature for storage for function (VDE 0413T2/§4.6.) TAmbSt TAmb Fitting position any Attachment Fast attachment on mounting rail DIN 50022; chassis assembly with adapter (on request) weight m 8 -30°C..+85°C/243 K..358 K -10°C..+70°C/263 K..343 K (0..+40°C/f.gr. VDE 0413T2§4.4) approx. 180 g (including connecting line) GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 Insulation monitor - GMWISO 1.05 Dimensions (height x width x depth) 77 mm x 35 mm (2 T-N) x 44 mm Connection approx. 400 mm connecting line with end splices with 5 leads Connection method Load current switch - supply circuit identical with voltage circuit (input voltage - switched internally) System of protection(DIN40050) IP 65 for compund-filled module Build Shakeproof in the completely compound-filled module housing Regulations Device corresponds to VDE 0413 part 2/1.73; Application for applications acc. to VDE 0100T728§4.2.4.2.1 as well as GW 308 GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen, Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-25 9