Download I. Cardiac cycle A. Consists of one beat, or one P-QRS

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Cardiac contractility modulation wikipedia , lookup

Quantium Medical Cardiac Output wikipedia , lookup

Arrhythmogenic right ventricular dysplasia wikipedia , lookup

Heart arrhythmia wikipedia , lookup

Electrocardiography wikipedia , lookup

Transcript
I. Cardiac cycle
A. Consists of one beat, or one P-QRS-T sequence.
1. The sequence: Atrial contraction (systole) and relaxation (diastole), followed
by ventricular contraction and relaxation
2. The cardiac cycle is measured on ECG from one R wave to the next R wave
3. Between cycles the ECG recorder returns to baseline or isoelectric line – the
flat line between the T wave and the next P wave
B. Waveform deflections
1. Any waveform above the isoelectric line is positive (upright)
2. Any waveform below the isoelectric line is negative (downward)
3. Any waveform having both a positive and a negative component is called a
biphasic deflection
II. Waveforms and current flow
A. An ECG lead provides a particular view of the hearts electrical activity between two
points or poles
B. Each lead consists of a positive (+) pole and a negative (–) pole
C. The configuration of the waveform seen in each lead will depend on the placement of
that lead relative to the path of cardiac electrical activity
D. The wave will be positive (deflected upward) if the electrical activity of the heart
approaches the positive lead
E. Conversely, the wave will be negative (deflected downward) if the electrical activity
of the heart move away from the positive lead
III. ECG paper
A. The P-QRS-T sequence is recorded on special graph paper
B. The vertical lines measure amplitude or voltage
1. Each small box represents 0.1 mV
2. Each large block (made up of 5 small boxes) represents 0.5 mV
3. To determine the amplitude of a wave, segment or interval, count the number
of small boxes from the baseline to the highest or lowest point
C. The horizontal lines measure time
1. Each small box equals 0.04 seconds
2. Each large block (made up of 5 small boxes) equals 0.2 seconds (multiply 0.04
x 5 = 0.2)
3. The width of complexes and intervals are determined by the number of small
boxes they extend over, then multiply by the time 0.04
4. When measuring or analyzing a heart rate or rhythm, a minimum of 6 seconds
(30 large blocks) should be used
IV. Waves, Intervals, Segments, and Complexes
A. P wave
1. The first deflection of the cardiac cycle
2. Represents depolarization of the atria
3. Begins as the waveform begins to leave the baseline, and ends when it returns
to baseline
4. Normal: Location - precedes every QRS complex
b) Amplitude - 0.5 to 2.5 mm high Rounded
c) Duration - 0.06 to 0.12 seconds
d) Configuration - small, rounded, similar in size and shape
e) Deflection - positive (upright) in lead II
5. Normal P waves indicate:
a) the electrical impulse originated in the SA node
b) that normal depolarization of the atria occurred
6. Abnormal P waves:
a) Inverted - indicates reverse (retrograde) conduction from the AV
junction backward toward the atria
b) Peaked, notched or enlarged - the sinus impulse traveled through altered
or damaged atria
c) Varying - the impulse may be coming from different sites
d) Absent - conduction by a route other that the SA node
e) Not preceding a QRS - heart block
B. PR interval
1. Represents the time required for the electrical impulse to leave the SA node and
travel through the atria, AV node, bundle branches, and Purkinje fibers
2. Normal:
a) Location - from the beginning of the P wave to the beginning of the
QRS complex, includes the P wave and the short flat (isoelectric) line that
follows it
b) Amplitude - not measured
c) Duration - 0.12 to 0.20 seconds
3. Normal PR interval indicates that the electrical impulse leaving the SA node
was conducted through the entire electrical system within a normal amount of
time
4. Abnormal PR interval:
a) Short
(1) Electrical impulse was conducted through an abnormal
pathway that bypasses the AV node, or
(2) The impulse originated in an ectopic site close to the AV
junction
b) Long - indicates the electrical impulse is delayed traveling through the
AV node and bundle of His
C. QRS complex
1. Represents ventricular depolarization
2. Measured from the beginning of the QRS as the first wave leaves the baseline
to the J point
3. J point
a) The junction between the QRS and the ST segment
b) Where the last wave of the complex begins to flatten out at, above, or
below the baseline
c) Elevation or depression of the ST segment can make finding the J point
difficult
4. Normal:
a) Location - follows the PR interval
b) Amplitude - varies greatly
c) Duration - 0.06 to 0.10
d) Configuration (use figure 3-6, p18, Huff)
(1) consists of the Q wave (the negative deflection before the R
wave), the R wave (the first positive deflection after the Q wave),
the S wave (the first negative deflection after the R wave)
(2) May not always see all three waves.
(3) The second R or S waves are labeled R'(R prime) or S'(S
prime)
e) Deflection - different in each lead
5. Normal QRS indicates that ventricular depolarization occurred within a normal
amount of time
6. Abnormal (wide) QRS indicates that abnormal depolarization has occurred due
to
a) Bundle branch block
b) Conduction through an abnormal pathway
c) The impulse originated in an ectopic site in the ventricles
D. ST segment
1. Represents the end of ventricular conduction
2. Normal:
a) Location - extends from the S wave to the beginning of the T wave
b) Deflection - usually isoelectric
3. Normal indicates the end of ventricular depolarization and the beginning of
repolarization
4. Abnormal
a) Elevation is a sign of myocardial injury
b) Depression is most often associated with myocardial ischemia
E. T wave
1. Represents ventricular recovery or repolarization
2. Normal:
a) Location - follows the S wave
b) Amplitude - 0.5 mm, greater in MCL
c) Duration - duration 0.10 to 0.25 seconds
d) Configuration - rounded, slightly asymmetrical (ascends more slowly
than the descent)
e) Deflection - usually positive
3. Abnormal T waves indicate abnormal repolarization has occurred
F. QT interval
1. Measures ventricular depolarization and repolarization
2. Normal:
a) Location - from the beginning of the QRS to the end of the T wave
b) Duration
(1) Varies according to heart rate, influence of medications, and
other factors
(2) Should not be greater than half the distance between two
regular R waves
3. Abnormal:
a) Long - indicates that ventricular repolarization time has slowed, which
means that the relative refractory period (the vulnerable period) of the
cardiac cycle is longer, predisposing patients to potentially lethal
ventricular dysrhythmias
b) Short - may result from digitalis toxicity or hypercalcemia
G. U wave
1. Represents the recovery period of the Purkinje fibers
2. Is not present of every rhythm strip, best seen with slow heart rates
3. Configuration is the most important characteristic
4. Normal:
a) Location - after the T wave and before the next P wave
b) Configuration - upright and rounded
c) Deflection - upright
5. Abnormal - prominent U waves may be due to hypercalcemia, hypokalemia or
digitalis toxicity
V. Cardiac monitors – 2 types of recordings
A. Standard 12 lead (additional material regarding 12 lead recordings is outside the scope
of this class)
1. Uses 10 electrodes to obtain a more complete view the heart
2. Records 12 different views of the heart, at different angles
3. Provides a complete picture of the hearts electrical activity
B. Single lead
1. Also known as rhythm monitoring
2. Provides continuous information about the hearts electrical activity
3. Chest leads pick up the electrical activity and displays it on a monitor
4. Electrodes are conductive gel discs that are placed on the patient's chest, these
discs should be changed every 24 hours to avoid drying of the discs. Drying of the
disc can cause poor tracings
VI. Types of single lead monitoring
A. Hard wire monitoring
1. Electrodes are attached to a cable which feed into a cardiac monitor
2. The monitor can be permanently attached in a patient room or can be portable
3. 3 leadwire system (used with portable monitors)
a) Made up of 3 leadwires
(1) white – right arm (RA)
(2) black – left arm (LA)
(3) red – left leg (LL)
b) Lead placement
(1) RA is placed right below the clavicle (2nd intercostal space)
right midclavicular line
(2) LA is placed right below the clavicle (2nd intercostal space) left
midclavicular line
(3) LL is placed on the left lower rib cage (8th intercostal space,
left midclavicular line)
c) Leads placed in this position will allow the monitoring in leads I, II, or
III using the lead select on the monitor
d) To monitor MCL (V1) – reposition the LL lead to the V1 position (4th
intercostal space, right sternal border), and change the lead select on the
monitor
4. 5 leadwire system (used mostly in the Critical Care Units)
a) Made up of 5 leadwires
(1) white – right arm (RA)
(2) black – left arm (LA)
(3) red – left leg (LL)
(4) green – right leg (RL)
(5) brown – chest lead (C)
b) Lead placement
(1) RA is placed right below the clavicle (2nd intercostal space)
right midclavicular line
(2) LA is placed right below the clavicle (2nd intercostal space) left
midclavicular line
(3) LL is placed on the left lower rib cage (8th intercostal space,
left midclavicular line)
(4) RL is placed on the right lower rib cage ( 8th intercostal space,
right midclavicular line)
(5) C is usually placed in the MCL or V1 position (4th intercostal
space, right sternal border), but can be moved to any of the 6 chest
lead positions
c) This configuration allows you to monitor any of the of the standard 12
leads using the lead selector on the monitor
B. Telemetry
1. The patient is attached to a small transmitter box
2. Radio waves transmit the tracing to a central monitor (this is when cell phones
can interfere)
3. Telemetry systems
a) Also made up of 3 leadwires
(1) negative – usually white
(2) positive – usually red
(3) ground – usually black
b) The lead that will be monitored depends on the placement of the
electrodes
c) Most commonly used leads are: (refer to lead placement handouts)
(1) lead II – NEGATIVE (white) @ 2nd intercostal space, right
midclavicular line, POSITIVE (red) @ 8th intercostal space, left
midclavicular line, GROUND (black) @ (2nd intercostal space, left
midclavicular line
(a) best lead for viewing the atrial activity – P wave
(b) lead II tracing shows a positive or upward deflection
since the electrical activity of the heart approaches the
positive lead
(2) MCL – NEGATIVE (white) @ 2nd intercostal space, left
midclavicular line, POSITIVE (red) @ 4th intercostal space, right
sternal border, GROUND (black) @ 2nd intercostal space, right
midclavicular line
(a) best lead for differentiating ventricular arrhythmia
(b) MCL tracing shows a negative or downward deflection
since the electrical activity of the heart move away from the
positive lead
C. Applying electrodes
1. Prepare the skin
a) Shave the skin if necessary – hair interferes with the contact between
the electrode disc and the skin
b) Remove skin oil – use a dry washcloth or soap and water
2. Attach electrode disc
a) Avoid placing over bony areas
b) Check to make sure electrode dics are not dry
VII. Criteria for identification of rhythm strips
A. Use calipers
B. 6 step method of interpretation
1. Check rhythm for regularity
a) Is the rhythm regular
b) Is the rhythm irregular
c) Is the rhythm regularly irregular
2. Calculate the ventricular rate (use one of the three methods)
a) If regular: divide 1500 by the number of small boxes between two R
waves
b) If irregular: count the number of R waves on a 6 second strip and
multiply by 10
c) Rapid method: start with an R wave that falls on a heavy black line and
stop at the closest R wave counting 300, 150, 100, 75, 60, 50, 43, 37
3. Measure the QRS complex
a) Are all the complexes the same size and shape
b) Is the QRS complex normal, less than 0.10 seconds
4. Identify and examine the P waves
a) Do the P waves have normal configuration
b) Do all the P waves have the same size and shape
c) Is there only one P wave for each QRS
d) If more than one P wave for each QRS, what is the ratio
5. Measure the PR interval
a) Is the PR interval normal, 0.12 - 0.20 seconds
b) Is the PR interval constant
6. Identify the rhythm or rhythms