Download N-Vision Motor Controller AI-NV002-01-x

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Opto-isolator wikipedia , lookup

Standby power wikipedia , lookup

Public address system wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Stepper motor wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power inverter wikipedia , lookup

Induction motor wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Voltage optimisation wikipedia , lookup

Control system wikipedia , lookup

Buck converter wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Electric power system wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Audio power wikipedia , lookup

Studio monitor wikipedia , lookup

Power electronics wikipedia , lookup

Electrification wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Power engineering wikipedia , lookup

Power over Ethernet wikipedia , lookup

Switched-mode power supply wikipedia , lookup

AC adapter wikipedia , lookup

Stage monitor system wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Transcript
N-Vision Motor Controller
AI-NV002-01-x
Product Description
The AI-NV002-01-x provides motor control for LCD monitor
extending and retracting and is designed to specifically interface
with the in-seat LCD 6.5” Monitor. The unit activates the ON/OFF
controls of the video monitor mechanism.
The “-x” suffix denotes the type of connector utilized in
installation.
Features
The following list provides an overview of features for the
AI-NV002-01-x:
G
G
G
G
G
G
G
G
G
Reverse voltage protection
Delayed power reset
Variable time shut-off during opening and closing
Variable motor speed control
Monitor supply switch output
Video input BNC connector
5 second power interrupt protection
Compact, lightweight
Designed to meet aircraft standards
7.
Application Notes
1.
2.
3.
The AI-NV002-01-x is utilized in applications where motorized
deployment of in-arm 6.5” LCD video monitors is required.
A motor speed adjust screw (POT 1) is located on the rear of
the unit. To increase the speed of the arm motor, turn the
screw clockwise. To decrease the motor speed, turn the
screw counterclockwise.
A limit timeout adjust screw (POT 2) is located on the rear of
the unit. To increase the amount of timeout, turn the screw
clockwise. To decrease the amount of timeout, turn the
screw counterclockwise.
8.
The power for the LCD monitor is controlled via monitor input
pin 1 and output pin 18. When the monitor is open, power is
switched “on” via an internal relay to output pin 18. When the
monitor is closed, the power is switched “off”. This ensures
the monitor is not powered when the monitor is closed. Pins
13 and 14 are provided for an external kill switch that will
disable the monitor system when applicable.
Video signals from source equipment are sent to the
controller via shielded, coaxial cable. The cable connects to
the BNC connector on the back of the controller. The video
signal passes directly to the monitor through the control
module. Video output is provided on pins 15 through 17.
Technical Specifications
Electrical
Power
Installation Guidelines
1.
2.
3.
4.
5.
6.
Mounting screws are required to secure the unit. Refer to
outline drawing for mounting hole diameters and
configurations.
All video output lines shall be RG-179 coaxial cable or
equivalent. All video input cable shall be twisted shielded
cable with the shields properly grounded at the source.
All power and ground wires shall be 22 AWG, minimum
20 AWG preferred. Power ground wires shall be grounded
within twelve (12) inches of the unit. All wires shall be in
accordance with MIL-W-22759 or equivalent.
Twisted,
shielded cable must be in accordance with MIL-W-27500 or
equivalent. Protect power wires with circuit breakers or fuses
located close to the electrical power source bus.
The AI-NV002-01-x power input is protected against reverse
voltage polarity and is filtered to produce a more stable
supply.
The limit switch provides internal relays to control inputs for
external limit switches for minimum and maximum travel.
Open S-1 is located on pins 5 and 6, close S-2 on pins 7
and 8. To provide protection against limit switch failures, an
adjustable 2-15 second timing circuit is utilized; POT 1. This
circuit controls the time delay that shuts off the motor and
solenoid. When the time limit has expired, the motor and
solenoid will disengage for added protection.
Power reset controls the power up sequence for the
controller. It ensures the controller will begin at a known state
and serves as a safety feature. The LCD monitor will
automatically close if the monitor is open and power has been
removed for more than 5 seconds. Any power interruption
less than 5 seconds will have no affect on the monitor. By
interrupting power via the kill switch for more than 5 seconds,
the monitor will automatically close if the trigger input is not
active. Also, the control circuitry is designed to prevent power
glitches from affecting the status of the LCD monitor.
Potentiometer 1
Mechanical
Potentiometer 2
Motor
Solenoid
Total Power
Consumption
Dimensions
(L x W x H)
Weight
Drawings
522398 Rev IR
Level
IR
45 mA @ +28 VDC
(when closed)
500 mA @ +28 VDC
(while opening)
2-15 second timing circuit
variable timed shutoff
Motor speed control
1.5 Amps
1.5 Amps
48W maximum
5.0” x 3.1” x 1.1”
12.7cm x 7.87cm x 2.79cm
0.42 lbs / 0.19 kg
Description
AI-NV002-01-x Outline Drawing
Document # 530343 – Revision History
Date
Description
2/2000
Initial Release
PROPRIETARY NOTICE
Despite any copyright notice, this data and information
disclosed herein contains confidential, proprietary designs owned
by Audio International, Incorporated. Neither this data nor the data
contained herein shall be reproduced, used, or disclosed to
anyone without the written authorization of Audio International, Inc.
Audio International, Inc. • 7300 Industry Drive, N Little Rock, AR 72117 • Phone 501-955-2929 / Fax 501-955-2988 / www.audiointl.com