* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 256 Directional Power Relay www.GEindustrial.com/pm Simplify the
Ground (electricity) wikipedia , lookup
Standby power wikipedia , lookup
Stray voltage wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Fault tolerance wikipedia , lookup
Wireless power transfer wikipedia , lookup
Power factor wikipedia , lookup
Power over Ethernet wikipedia , lookup
History of electric power transmission wikipedia , lookup
Buck converter wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power dividers and directional couplers wikipedia , lookup
Audio power wikipedia , lookup
Power electronics wikipedia , lookup
Electric power system wikipedia , lookup
Nominal impedance wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electrification wikipedia , lookup
Power engineering wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
MIW Directional Power/Loss of Field Once the magnitude of the three-phase total power in the forward direction (positive MW) falls below the pickup level for the specified period of time an alarm will occur. 10 The level is programmed in per unit of generator MW calculated from the rated MVA and rated power factor. The low forward power element is active only when the generator is online and will be blocked until the generator is brought online, for a period of time defined by the setpoint. The pickup level should be set lower than expected generator loading during normal operations. If the fuse failure function is operated the 32LF unit will be disabled. Fuse Failure (60) The MIW includes a VT fuse failure unit. The unit checks the presence of negative sequence voltage against positive sequence voltage and the current value. Simplify the order process – visit our on-line store www.GEindustrial.com/pm 256 Directional Power Relay Z1oe Metering z2 MIW provides metering values for phase and ground currents. The accuracy is 3% in the complete range. 741752A1.ai VAB IA - IB = M1oe<Ø1oe The formula: Z1oe = where: Z1oe = Configurable Logic Secondary phase to phase loss of excitation impedance M1oe<Ø1oe = Secondary impedance phasor (magnitude and angle) All relay quantities are in terms of secondary impedances. The formula to convert primary impedance quantities to secondary impedance quantities is provided below. Up to a maximum of 4 configurable logic schemes can be implemented into the MIW by means of using a set of 4 pre-configured logic gates and timer cells. A graphical user interface is provided for configuration of MIW logic. The outputs of the MIW configurable logic can be used to configure digital outputs and LEDs. Zpri X CTratio VTratio primary ohms impedance programmed CT ratio, if CT ratio is 1200:5 use a value of 1200/5 = 240 programmed VT ratio, if VT ratio is 100:1 use a value of 100 where: Zsec Zpri = CTratio = VTratio = = WIRING OPEN DELTA VT CONNECTION PHASE A CT A B A C B SINGLE PHASE VT CONNECTION NOTE: 14 AWG wiring recommended AC or DC C A B C B1 B2 B3 B4 A3 A4 B1 B2 B3 B4 A3 A4 C1 C2 A1 A2 B1 B2 B3 B4 A3 A4 VA N VB N VC N VA N VB N VC N IA N +/L -/N VA N VB N VC N VOLTAGE INPUTS VOLTAGE INPUTS POWER Loss of Excitation (40) The MIW detects loss of excitation by using an impedance element on wye connected generators. When the impedance falls within the impedance circle for the delay time specified a trip will occur if it is enabled. The user can enable circle#1 and/or circle#2 to tune their protection feature to their system. The larger circle diameter should be set to the synchronous reactance of the generator, xd and the circle offset should be set to the generator transient reactance x’d/2. This element will be blocked if there is a fuse failure condition or if the generator is offline. Offset z1 Diameter 52a TRIP COIL CONTROL POWER + << 52a TRIP COIL GE Power Management >> A5 A6 CAUTION: Fork or ring terminals must be used on the termainal block. NOTE: Suitable disconnect devices (switch or circuit breaker) recommended located near the relay. OVERVOLTAGE CATEGORY: II B5 B6 MIW Internally fused 1A/250V fast blow Directional Power & Loss of Field Relay A8 CC1 A9 CC2 A10 COM RS232 SAFETY GND GROUND GROUND BUS CURRENT INPUT VOLTAGE INPUTS SDA B12(*) A SDB A12(*) B GND B11(*) GROUND JX COM OUT4 OUT3 OUT1/2 OUT1 Directional Low Forward Power (32LF) M1oe RS485 If the generator is accelerated from the power system rather than the prime mover, the reverse power element may be blocked from start for a selectable period of time. Ø1oe DIGITAL OUTPUTS(**) The level is programmed in per unit of generator MW calculated from the rated MVA and rated power factor. DIGITAL INTPUTS(**) Once the magnitude of the three-phase total power exceeds the pickup level in the reverse direction (negative MW) for the specified period of time a trip will occur. jx Two configurable inputs are provided for breaker status and block the loss of field. Four configurable outputs are provided for the operation of the 32RP, 32LP, 40 and 47 units. TRIP Directional Reverse Power (32RP) Inputs and Outputs READY PROTECTION B7 B8 INPUT PROGRAMMABLE CONTROLLER B9 B10 A7 INPUT 741750A1.ai ORDERING To order select the basic model and the desired features from the Selection Guide below. MIW1 0 * 0 E 2 0 0 * 0 0 * 1 5 F H Phase CT In = 1A (0.1 - 2.4 A) Phase CT In = 5A (0.5 - 12 A) 24-48 VDC (Range: 19 ~ 58 Vdc) Power Supply 110-250 VDC (Range: 88 ~ 300 Vdc) Power Supply 120-230 VAC (Range: 88 ~ 264 Vac) Power Supply C Individual relay S Mounted in an M+ system† Accessories DEPTH REDUCING COLLAR: Reduces the mounting depth in 63 mm. †If relays are to be mounted in an M+ system either an M050 half 19" rack or M100 full 19" rack case must be ordered. The M050 and M100 racks are provided at no additional cost. www.GEindustrial.com/pm