Download HH ILS C DC 200 5K V

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Control system wikipedia , lookup

Opto-isolator wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Rectiverter wikipedia , lookup

Electrical ballast wikipedia , lookup

Transcript
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
CIRCULAR SYSTEM
CIRCULAR LAMP SYSTEM SPECIFICATIONS
System Model
Number
HH-ILS-CP40-5K
HH-ILS-CDS40-5K
HH-ILS-CP55-5K
HH-ILS-CP70-5K
HH-ILS-CDS70-5K
Input Power
(W)
Rated Initial
Lumens (LM)
Efficacy
(LM/W)*
40
Input current
(Amp) 120V 277V
0.35 - 0.15
42
2800 - 3000
70 - 75
55
0.48 - 0.21
58
4125 - 4380
75 - 80
70
0.62 - 0.27
74
4900 - 5250
70 - 75
80
0.70 - 0.30
84
5600 - 6000
70 - 75
100
0.88 - 0.38
105
7500 - 8000
75 - 80
120
1.05 - 0.45
126
9000 - 9600
75 - 80
Watts
Lumen Maintenance
CRI
(60Khrs)
Color Temp.
(Kelvin)
Average Lamp
Life (Hours)
2700K - 6500K
(5K Standard Color)
100,000
HH-ILS-CP80-5K
HH-ILS-CDS80-5K
HH-ILS-CDC80-5K
HH-ILS-CP100-5K
HH-ILS-CDS100-5K
HH-ILS-CDC100-5K
HH-ILS-CP120-5K
HH-ILS-CDS120-5K
HH-ILS-CDC120-5K
70%-75%
HH-ILS-CP150-5K
HH-ILS-CDS150-5K
150
1.32 - 0.57
158
12000 - 12750
80 - 85
200
1.75 - 0.76
210
16000 - 17000
80 - 85
250
2.19 - 0.95
263
21250 - 22500
85 - 90
300
2.63 - 1.14
315
25500 - 27000
85 - 90
400
3.50 - 1.52
420
34000 - 36000
85 - 90
500
4.61 - 2.00
525
42500 - 45000
85 - 90
> 80
HH-ILS-CDC150-5K
HH-ILS-CP200-5K
HH-ILS-CDS200-5K
HH-ILS-CDC200-5K
HH-ILS-CP250-5K
HH-ILS-CDS250-5K
HH-ILS-CDC250-5K
HH-ILS-CDS300-5K
HH-ILS-CDC300-5K
HH-ILS-CDS400-5K
HH-ILS-CDC400-5K
HH-ILS-CDS500-5K
* NOTE: Bare Lamp specifications will vary from fixture test results; LM/W is based on tested Lamp Power.
Reference "RELATIVE LUMEN OUTPUT CHART" and contact Fulham for proper Spectrophotocolormeter "Sphere" test procedures.
SYSTEM ELECTRICAL SPECIFICATION COMMON TO ALL GENERATORS
CERTIFICATIONS
Input Voltage
120-277V
EMI/RFI Compliance
FCC Part 18-A
Voltage Fluctuation Tolerance
±10%
Sound Rating
Class A
Input Frequency
50/60 Hz
Type
1 Outdoor
Output Frequency
<250K Hz
Surge Protection**
Yes (Reference hi-pot test footnote)
THD
< 10%
Max. Remote Distance***
7 ft. (84”) (Reference Wiring Footnote)
Power Factor
> 0.95
Wiring
Plug-n-Play Connectors
Constant Wattage Output
<5%
150°C 600V (Lamp Wire Shielded)
Case Temp.
< 65°C
Wire Rating
Electrostatic Discharge (ESD)
Operating Temp. Open Fixture 0°C to 50°C
Operating Temp. Closed Fixture -20°C to 50°C
E323972
IEC 61000-4-2:Class 4
Electrical Fast Transient/Burst(EFT) IEC 61000-4-4: Level 4
Surge Immunity
IEC 61000-4-5: Class 4
**Surge Protection: Contact Fulham before conducting Hi-Pot test.
***Wiring: Do not modify wire type or length without contacting Fulham for assistance. Reference remote mount options chart for special factory order systems and wire extensions under Lamp Advanced Features.
SYSTEM MODEL NUMBER EXAMPLE
HH
HH = HIGHHORSE
ILS
C
ILS = INDUCTION
LIGHTING SYSTEM
C = CIRCULAR
LAMP
DC
200
SYSTEM WATTS
DC = DIE CAST
DS = DISC BALLAST
P = PROFILE BALLAST
5K
KELVIN TEMP.
Specify Kelvin when ordering.
5K is standard stock color.
V
REMOTE MOUNT
Reference Remote
Mount Options
Chart for Code.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-1-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
CIRCULAR SPECIFICATIONS
CIRCULAR LAMP SYSTEM SPECIFICATIONS
Lamp Type
Circular/Tubular
External Inductor Type
Hybrid Fluores cent
All
Prim ary Ignition
Low Frequency Inductor Coil
Operating Temperature Range (Thermal Management)
Induction Lam p Core Mounting Bas e
100°C - 130°C
Am algam Lam p Tip Tem perature Range
55°C - 125°C
Lam p Coil
160°C - 200°C
Circular/Tubular
Convection or Conduction
Lamp Operation
Color Tem perature Fluctuation
<10%
LPW Fluctuation
<10%
Lamp Kelvin Temperature Options
Kelvin Tem perature (Standard)
5000K
Lim ited Stock (call Fulham for availability)
3500K, 4000K
Special Factory Order (call Fulham )
2700K, 3000K, 6000K, 6500K
Kelvin Color Tem perature Tolerance
±300K
Cold Start and Operation Systems
Operating Tem perature (Clos ed Fixture)
-40°C Freezer Operation Only (Call Fulham for As s is tance)
EMI
Meets International Standard L Level FCC Non-Cons um er units Com pliant FCC 47-CFR Part 18
Vibration Tests
The HighHors e Induction lam p is des igned to tolerate s hock and vibration that would be expected in typical applications
s uch as pos t top, bridge, roadway underpas s or tunnel lighting. HighHors e Induction lam ps have been tes ted under the
following conditions with no dam age:
-Shock - Lam ps s ubjected to three (3) one-half wave s hocks of 10 m s duration at 20 g.
-Vibration param eters adapted from ANSI C136.31-2001, Am erican National Standard for Roadway Lighting Equipm ent Lum inaire Vibration, Section 5, lum inaire vibration tes t.
Start Freq.
5Hz
Amplitude
1.5 G
End Freq.
7.07107 Hz
10Hz
3.5 G
30Hz
Sweep between 5 Hz and 30 Hz at 0.861654 Min/s weep (Linear)
Duration: 100,000 cycles at 100%
Total tes t tim e: 1:36:30
Care s hould be taken when m ounting ballas t to m inim ize vibration
Amplitude
3.5 G
3.5G
UV
UV (bare lam p-les s with lens )
5uw/cm 2
* LPW is related to the temperature of Amalgam and Kelvin Temperature to maintain >90% output.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-2-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
CIRCULAR SPECIFICATIONS
CIRCULAR LAMP SYSTEM SPECIFICATIONS (Part II)
Am algam Hg.
Am algam Type
High Quality Solid Pellet
Am algam Chart
Lamp Type
C40W
C55W
C70W
C80W C100W C120W C150W C200W C250W C300W C400W C500W
Amalgam Type
B
B
B
B
B
B
B
C
C
C
C
C
Weight/ PC (mg)
40
40
40
40
40
40
40
40
40
40
40
40
PCS
2
2
3
3
3
4
5
6
9
10
11
11
Total Weight (mg)
80
80
120
120
120
160
200
240
360
400
440
440
Content of Hg in %
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3
3
3
3
3
Pure
HgOrientation
Weight (mg)
Lam p
2.8
2.8
4.2
4.2
4.2
5.6
7
7.2
10.8
12
13.2
13.2
Circular (Am algam Tube-Down Orientation)
See page 4
Lam p Advanced Features
• Ultra-High Life 100,000hr Rated Lam p Technology
• Wide Range of Wattage Options 40W - 400W
• Full Kelvin Color Range 2700-6500K
• Ins tant Start
• Flicker Free Operation
• Frequency Power Tuned Wattage to Ballas t
• High Quality Phos phor Blends
• High CRI (Color Rendering Index)
• High Quality Solid Am algam Pellet
• Ultra-Low Mercury Content (Encaps ulated)
• Pre-Wired Lam p Input Connector
• Univers al Heat Sink Mounting
• Alum inum Coil Shield (Non-Corros ive)
• Com patible with Fulham Dim m ing Generators
• Com patible with Motion and Light Sens or Line Controls
MADE IN AMERICA
The Office of Energy Efficiency and Renewable Energy (“EERE”) at the US Department of Energy (“DOE”) has recently issued guidance relating to the Buy American Provisions of the
Recovery Act. EERE issued the attached (i) Guidance on Manufactured Goods and Substantial Transformation for Financial Assistance Awards on May 24, 2010 (“Guidance”) and (ii)
Memorandum of Decision granting a waiver of Section 1605 for Induction Lamps and Generators on August 11, 2010 (“Waiver”). The Guidance and Waiver are applicable to projects
receiving financial assistance under the Recovery Act and are in effect until further notice from the DOE.
Applying the terms of the Waiver, Fulham’s induction lamps and generators are categorically exempt from the Buy American Provisions. Please use the matrix below in determining the
applicability of the Buy American Provisions to the constituent parts provided by Fulham for New or Retrofit Induction Fixtures.
Fulham Induction Lamps
Exempt Under Waiver
Fulham Induction Generators
Exempt Under Waiver
Fulham Retrofit Kit (Reflector and Mounting Kit only) Made in America
The above determination does not apply to imported New or Retrofit Induction Fixtures (including the constituent housing, reflector, mounting kit and lens) supplied by customers or
third parties. Each such item must be evaluated under the Recovery Act, Guidance and Waiver on a case by case basis by the customer or third party for compliance with the Buy
American Provisions.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-3-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
LAMP ORIENTATION
Amalgam Tube on the down side orientation for all possible lamp orientations.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-4-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
INRUSH / INDUCTANCE
CIRCULAR SYSTEM INRUSH CURRENT
System Model
Number
HH-ILS-CP40-5K
Watts
Voltage
Inrush
Current
Inrush
Period
40
120V
9.0A
600.0ìs
System Model
Number
HH-ILS-CP70-5K
55
70
120V
120V
14.0A
14.0A
700.0ìs
700.0ìs
120V
14.0A
700.0ìs
277V
18.0A
500.0ìs
70
277V
27.0A
600.0ìs
80
277V
27.0A
600.0ìs
100
277V
27.0A
600.0ìs
120
277V
27.0A
600.0ìs
150
277V
32.0A
700.0ìs
200
277V
34.0A
800.0ìs
250
277V
35.0A
800.0ìs
300
277V
36.0A
830.0ìs
400
277V
39.0A
830.0ìs
HH-ILS-CP100-5K
100
120V
14.0A
700.0ìs
HH-ILS-CDS100-5K
HH-ILS-CDC100-5K
HH-ILS-CP120-5K
120
120V
14.0A
700.0ìs
HH-ILS-CDS120-5K
HH-ILS-CDC120-5K
HH-ILS-CP150-5K
HH-ILS-CP150-5K
150
120V
14.0A
850.0ìs
HH-ILS-CDS150-5K
As with all electronic
equipment, Fulham Induction
Systems have a peak current
shortly after the mains is
switched on; while this is a
momentary condition it is
important to calculate the total
load during this peak current
demand. It is advised to use
C-type MCBs in lighting
installations with electronic
ballasts. If it is absolutely
necessary to connect more
than the specified maximum
number of fixtures based on
peak demand contact a
Licensed Electrician and
consider a relay in the wiring
circuit to limit the number of
activated fixtures at one time.
HH-ILS-CDC150-5K
HH-ILS-CDC150-5K
HH-ILS-CP200-5K
HH-ILS-CP200-5K
200
120V
16.0A
900.0ìs
HH-ILS-CDS200-5K
HH-ILS-CDC200-5K
HH-ILS-CDC200-5K
HH-ILS-CDS250-5K
HH-ILS-CDS250-5K
250
120V
18.0A
900.0ìs
HH-ILS-CP250-5K
HH-ILS-CDC250-5K
HH-ILS-CDC250-5K
300
120V
22.0A
HH-ILS-CDS300-5K
900.0ìs
HH-ILS-CDC300-5K
HH-ILS-CDC300-5K
HH-ILS-CDS400-5K
55
HH-ILS-CDC80-5K
HH-ILS-CDC120-5K
HH-ILS-CDS300-5K
500.0ìs
HH-ILS-CDS80-5K
HH-ILS-CP120-5K
HH-ILS-CP250-5K
18.0A
HH-ILS-CP80-5K
80
HH-ILS-CDC100-5K
HH-ILS-CDS200-5K
277V
HH-ILS-CDS70-5K
HH-ILS-CP100-5K
HH-ILS-CDS150-5K
40
HH-ILS-CP70-5K
HH-ILS-CDC80-5K
HH-ILS-CDS120-5K
Inrush
Period
HH-ILS-CP55-5K
HH-ILS-CP80-5K
HH-ILS-CDS100-5K
Inrush
Current
HH-ILS-CDS40-5K
HH-ILS-CDS70-5K
HH-ILS-CDS80-5K
Voltage
HH-ILS-CP40-5K
HH-ILS-CDS40-5K
HH-ILS-CP55-5K
Watts
400
120V
25.0A
HH-ILS-CDS400-5K
950.0ìs
HH-ILS-CDC400-5K
HH-ILS-CDC400-5K
NOTE: ALWAYS CONSULT A LICENSED ELECTRICIAN BEFORE INSTALLING ANY ELECTRICAL DEVICE.
CIRCULAR LAMP INDUCTANCE
Coupler Value
40W
55W
70W
80W
100W
120W
150W
200W
250W
300W
400W
L (Inductance)
600.0µH
600.0µH
760.0µH
680.0µH
600.0µH
760.0µH
530.0µH
650.0µH
700.0µH
650.0µH
650.0µH
Windings (Turns)
16
16
18
17
16
18
15
16
13
12
12
Frequency
250khz
Connected Method
Ls
Room Ambient
25°C
All types of Inductance (Self/Mutual/Partial/Loop/Loop Mutual) are directly related to the number of magnetic fields around a conducter
per amp of current; it requires special equipment to measure inductance. Fulham Retro-fit Engineering Services is equipped to measure
and mitigate the effects of Inductance which ultimately can produce failure of the system when not considered in the design of an
Induction fixture. All Fulham engineered systems are certified to operate properly relative to Inductance, Thermal, and overall fixture
efficacy.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-5-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
REMOTE MOUNT
CIRCULAR SYSTEM REMOTE MOUNT OPTION
Standard Length
(in-stock)
Output Wire length:
10 ft.
20 ft.
30 ft.
40 ft.
50 ft.
HH-ILS-CP40-5K
HH-ILS-CP40-5KV
HH-ILS-CP40-5KW
HH-ILS-CP40-5KX
HH-ILS-CP40-5KY
HH-ILS-CP40-5KZ
HH-ILS-CP55-5K
HH-ILS-CP55-5KV
HH-ILS-CP55-5KW
HH-ILS-CP55-5KX
HH-ILS-CP55-5KY
HH-ILS-CP55-5KZ
HH-ILS-CP70-5K
HH-ILS-CP70-5KV
HH-ILS-CP70-5KW
HH-ILS-CP70-5KX
HH-ILS-CP70-5KY
HH-ILS-CP70-5KZ
HH-ILS-CP80-5K
HH-ILS-CP80-5KV
HH-ILS-CP80-5KW
HH-ILS-CP80-5KX
HH-ILS-CP80-5KY
HH-ILS-CP80-5KZ
HH-ILS-CDC80-5K
HH-ILS-CDC80-5KV
HH-ILS-CDC80-5KW
HH-ILS-CDC80-5KX
HH-ILS-CDC80-5KY
HH-ILS-CDC80-5KZ
HH-ILS-CP100-5K
HH-ILS-CP100-5KV
HH-ILS-CP100-5KW
HH-ILS-CP100-5KX
HH-ILS-CP100-5KY
HH-ILS-CP100-5KZ
HH-ILS-CDC100-5K
HH-ILS-CDC100-5KV HH-ILS-CDC100-5KW HH-ILS-CDC100-5KX HH-ILS-CDC100-5KY HH-ILS-CDC100-5KZ
HH-ILS-CP120-5K
HH-ILS-CP120-5KV
HH-ILS-CDC120-5K
HH-ILS-CDC120-5KV HH-ILS-CDC120-5KW HH-ILS-CDC120-5KX HH-ILS-CDC120-5KY HH-ILS-CDC120-5KZ
HH-ILS-CP150-5K
HH-ILS-CP150-5KV
HH-ILS-CDC150-5K
HH-ILS-CDC150-5KV HH-ILS-CDC150-5KW HH-ILS-CDC150-5KX HH-ILS-CDC150-5KY HH-ILS-CDC150-5KZ
HH-ILS-CP200-5K
HH-ILS-CP200-5KV
HH-ILS-CDC200-5K
HH-ILS-CDC200-5KV HH-ILS-CDC200-5KW HH-ILS-CDC200-5KX HH-ILS-CDC200-5KY HH-ILS-CDC200-5KZ
HH-ILS-CP250-5K
HH-ILS-CP250-5KV
HH-ILS-CDC250-5K
HH-ILS-CDC250-5KV HH-ILS-CDC250-5KW HH-ILS-CDC250-5KX HH-ILS-CDC250-5KY HH-ILS-CDC250-5KZ
HH-ILS-CDC300-5K
HH-ILS-CDC300-5KV HH-ILS-CDC300-5KW HH-ILS-CDC300-5KX HH-ILS-CDC300-5KY HH-ILS-CDC300-5KZ
HH-ILS-CDC400-5K
HH-ILS-CDC400-5KV HH-ILS-CDC400-5KW HH-ILS-CDC400-5KX HH-ILS-CDC400-5KY HH-ILS-CDC400-5KZ
HH-ILS-CP120-5KW
HH-ILS-CP150-5KW
HH-ILS-CP200-5KW
HH-ILS-CP250-5KW
HH-ILS-CP120-5KX
HH-ILS-CP150-5KX
HH-ILS-CP200-5KX
HH-ILS-CP250-5KX
HH-ILS-CP120-5KY
HH-ILS-CP150-5KY
HH-ILS-CP200-5KY
HH-ILS-CP250-5KY
HH-ILS-CP120-5KZ
HH-ILS-CP150-5KZ
HH-ILS-CP200-5KZ
HH-ILS-CP250-5KZ
Factory Special Order Only; subject to minumum quantity and lead times at time of order.
Contact Fulham for requirements prior to order. Orders are non-cancellable.
Lamp Advanced Features
POWER SOURCE:
120V - 277V
EXTENSION WIRE P/N
HHILPE00004
HHILPE00012
HHILPE00003
*HHILPE00007
LENGTH
INCHES
4"
12"
36"
84"
FEET
0.3'
1.0'
3.0'
7.0'
ASSEMBLY VIEW
SCALE 1:5
NOTE: Product is shipped as shown
SCALE 1:3
LENGTH
WIRE SHIELD
FEMALE CONNECTOR TO BALLAST
WIRE SPECIFICATIONS:
150°
600V
18AWG
MALE CONNECTOR TO LAMP
NOTE: Standard Extension Wires HHILPE00007 available for Circular and Tubular Lamp systems only.
Contact Fulham for assistance in engieering your custom wires options.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-6-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
LUMEN MAINTENANCE
Cold Start Lumen Maintenance Chart
Lumen Output (Fc)
Input Power (W)
(52ºC)
Lamp Amalgam Temp. ((°C)
°C)
(-30ºC)
10
20
40
60
80
100
120
140
160
180
200
220
240
322
382
MINUTES
HighHorse induction systems operate
within a wide range of ambient; the chart
is an example of a 100W induction system
operated at extreme cold temperature. It
is recommended if the system requires a
cold start at -30°C that a thermal blanket be
installed at the factory on the amalgam tip;
this will ensure a consistent start and rapid
stabilization of the lamp and lumen output.
Note: Closed fixture example, actual performance varies
with fixture types.
NOTE: Purpose of Lumen Maintenance Chart is strictly to show relation of the three variables over time.
% RATED LUMENS
100
95
Rated Lumen Maintenance Chart
90
Rated Lumen Maintenance is largely determined by operating temperature
of the lamp and quality of lamp design; Fulham HighHorse induction
systems are designed and manufactured with high quality tri-phosphors
and solid amalgam to optimize the performance and rated life of the lamp.
The above chart is intended to represent an average rated lumen output
stated as a percentage of the initial lumen output over the rated life of
the lamp. Operating the lamp within the temperatures specifcation will
typically result in not less than 70% lumen output at 60Khrs.
85
80
75
70
65
60
55
50
0
20,000
40,000
60,000
OPERATING HOURS
80,000
100,000
SURVIVAL %
100
90
System Rated Life Chart
80
System Rated Life varies with operating temperature and application.
Fulham HighHorse induction generators are designed with high quality
long lasting components and when operated at the rated Tc 65ºC
expected life is 60Khrs with failure rate of 15% to 20%. Operating
temperatures less than the rated Tc 65ºC can typically improve life
expectancy and reduce failure rate.
70
60
50
20,000
0
40,000
60,000
80,000
100,000
Relative Lumen Output
OPERATING HOURS
110
220
100
200
90
180
80
160
70
140
60
120
50
40
100
100W ballast
80
30
60
20
Lumen output is directly related t System Power and Amalgam Temperature;
properly designed systems result in a stable lamp condition and maximum light
output. All Fulham Engineered HighHorse Induction systems operate with less than a
15% vatiation over a wide range of Amalgam operating temperature (60ºC - 125ºC).
Fulham Retro-fit systems are engineered for a maximum light output and improved life
expectancy.
40
Relative Light Output
System Power
10
0
40
Relative Lumen Output Chart
50
60
70
80
90
100
110
120
130
20
0
140
Amalgam Temperature (C°)
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-7-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
TEMPERATURE TEST POINTS
PLEASE NOTE: Induction lamps are fragile and require care when
handling; DO NOT allow the glass to come in contact with metal
objects. The amalgam glass can be easily broken.
8
1
7
6
CIRCULAR LAMP
1
2
3
DISC BALLAST
3
3
1
2
2
DIE CAST BALLAST
PROFILE BALLAST
CIRCULAR INDUCTION SYSTEM TEMPERATURE CHART
T E S T P O IN T
1
2
3
4
5
6
7
8
9
10
11
12
13
T E M P E R AT U R E T E S T P O IN T S :
B ALLAS T : T C
B ALLAS T : S ID E 1
B ALLAS T : S ID E 2
B ALLAS T P LAT E /MO UNT ING LO C AT IO N
B ALLAS T AMB IE NT
LAMP B AS E (HE AT S INK )
LAMP C O IL
LAMP AMALGAM T IP
LAMP AMB IE NT
C O IL W IR E R AT ING
N/A
LAMP T UB E O N INS ID E C E NT E R
W IR E C O NNE C T O R
Note: Test points 2 and 3 are on the side of the
ballast; location is not precise.
R AT E D T E M P E R AT U R E
< 65ºC (149ºF )
< 65ºC (149ºF )
< 65ºC (149ºF )
N/A
N/A
100ºC (212ºF ) - 130°C (266°F )
< 160ºC (320ºF )
55ºC (131ºF ) - 125ºC (257ºF )
< 80ºC (176ºF )
< 140ºC (284ºF )
N/A
< 140ºC (284ºF )
< 105ºC (221ºF )
M AX T E M P E R AT U R E
65ºC (149ºF )
65ºC (149ºF )
65ºC (149ºF )
N/A
N/A
130ºC (266ºF )
200ºC (392ºF )
125ºC (257ºF )
< 100ºC (212ºF )
150ºC (302ºF )
N/A
180ºC (356ºF )
105ºC (221ºF )
NOTE: TEMPERATURE MEASUREMENTS ARE RECOMMENDED TO BE AT THE RATED TEMPERATURE FOR BEST PERFORMANCE AND LIFE EXPECTANCY.
LAMP AND GENERATOR TEMPERATURES MAY NOT EXCEED THE MAXIMUM OPERATING AMBIENT TEMPERATURE WHEN INSTALLED IN A FIXTURE.
CONTACT FULHAM FOR APPROVED TEMPERATURE TEST PROCEDURE.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-8-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
DIMENSIONS - CIRCULAR
H .03"
H .03”
L .15"
L .03"
X .15"
X .15"
40W - 55W
70W~400W
Circular Lamp
Model No.
L (in)
H (in)
ØX (in)
Input Wire L (in)
HH-IL-C40W5K
6.49
2.78
6.04
15 ± 1"
HH-IL-C55W5K
6.49
2.78
6.04
15 ± 1"
HH-IL-C70W5K
7.89
3.04
7.22
15 ± 1"
HH-IL-C80W5K
7.89
3.04
7.22
15 ± 1"
HH-IL-C100W5K
9.46
3.04
8.57
15 ± 1"
HH-IL-C120W5K
10.75
3.04
9.82
15 ± 1"
HH-IL-C150W5K
12.58
3.04
11.62
15 ± 1"
HH-IL-C200W5K
14.97
3.04
13.92
15 ± 1"
HH-IL-C250W5K
15.76
3.02
15.28
15 ± 1"
HH-IL-C300W5K
18.20
3.02
17.28
15 ± 1"
HH-IL-C400W5K
18.61
3.00
17.80
15 ± 1"
Contact Fulham for detailed drawings.
* Subject to change. Contact Fulham for specific wire lengths.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-9-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
DIMENSIONS - BALLASTS
X .05"
H .10"
Disc Ballast (White)
Disc Ballast
Model No.
SIZE
H (in)
ØX (in)
Input wire L (in)
Output wire L (in)*
HH-IB-UNV-CDS40
SMALL
9.52
8.04
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS70
SMALL
9.52
8.04
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS80
SMALL
9.52
8.04
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS100
SMALL
9.52
8.04
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS120
MEDIUM
10.30
9.60
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS150
MEDIUM
10.30
9.60
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS200
MEDIUM
10.30
9.60
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS250
STANDARD
10.94
11.04
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS300
STANDARD
10.94
11.04
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS400
STANDARD
10.94
11.04
10 ± 1"
10 ± 1"
HH-IB-UNV-CDS500
LARGE
11.75
14.99
10 ± 1"
10 ± 1"
Contact Fulham for detailed drawings.
* Subject to change. Contact Fulham for specific wire lengths.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-10-Rev Q
SYSTEM MODEL #:
DATE
/
/
PROJECT
TYPE
DIMENSIONS - BALLASTS
W± .03”
W± .03”
L± .03”
L± .03”
H± .03”
H± .03”
RUBBER GASKET
Die Cast Ballast (White)
Profile Aluminum Ballast (Black)
Die Cast ballast
Model No.
Size
L
W
H
Input Wire L (in)
Output Wire L (in)*
HH-IB-UNV-TCDC80
SMALL
10.16
7.49
3.12
35-45
4-5
HH-IB-UNV-TCDC100
SMALL
10.16
7.49
3.12
35-45
4-5
HH-IB-UNV-TCDC120
SMALL
10.16
7.49
3.12
35-45
4-5
HH-IB-UNV-TCDC150
SMALL
10.16
7.49
3.12
35-45
4-5
HH-IB-UNV-TCDC200
STANDARD
13.49
7.49
3.12
35-45
4-5
HH-IB-UNV-TCDC250
STANDARD
13.49
7.49
3.12
35-45
4-5
HH-IB-UNV-TCDC300
STANDARD
13.49
7.49
3.12
35-45
4-5
HH-IB-UNV-CDC400
STANDARD
13.49
7.49
3.12
35-45
4-5
Size
L
W
H
Input Wire L (in)
Output Wire L (in)*
HH-IB-UNV-CP40
SMALL "40"
5.98
3.66
1.63
10± 1"
10± 1"
HH-IB-UNV-CP55
SMALL "40"
5.98
3.66
1.63
10± 1"
10± 1"
HH-IB-UNV-TCP70
MEDIUM
7.06
4.12
1.91
10± 1"
10± 1"
HH-IB-UNV-TCP80
MEDIUM
7.06
4.12
1.91
10± 1"
10± 1"
HH-IB-UNV-TCP100
MEDIUM
7.06
4.12
1.91
10± 1"
10± 1"
HH-IB-UNV-TCP120
STANDARD
8.46
4.75
2.07
10± 1"
10± 1"
HH-IB-UNV-TCP150
STANDARD
8.46
4.75
2.07
10± 1"
10± 1"
HH-IB-UNV-TCP200
STANDARD
8.46
4.75
2.07
10± 1"
10± 1"
HH-IB-UNV-TCP250
LARGE
10.00
4.75
2.07
10± 1"
10± 1"
Profile Ballast
Model No.
Contact Fulham for detailed drawings.
* Subject to change. Contact Fulham for specific wire lengths.
This is an original product from Fulham, Co., Inc.
Fulham extends a limited warranty only to the original purchaser or to the first user for a period of 5 years from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please reference the Fulham product catalog (www.fulham.com)
Due to a program of continuous improvement, Fulham reserves the right to make modifications or variations in design or construction
to the equipment described.
2009-512-11-Rev Q