* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Grid measurement module - Bachmann electronic GmbH
Power factor wikipedia , lookup
Power over Ethernet wikipedia , lookup
Ground (electricity) wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Audio power wikipedia , lookup
Current source wikipedia , lookup
Electrification wikipedia , lookup
Electrical ballast wikipedia , lookup
Utility frequency wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Time-to-digital converter wikipedia , lookup
Electric power system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage regulator wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrical substation wikipedia , lookup
Protective relay wikipedia , lookup
Power engineering wikipedia , lookup
Distributed generation wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Distribution management system wikipedia , lookup
Surge protector wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Grid measurement module Grid Measurement and Protection module GMP232 Bachmann electronic‘s Grid Measurement and Protection module, the GMP232, is part of the M1 controller and enables safe, reliable, and fast measurement for three phase electrical networks. The GMP232 also provides a number of monitoring functions for generator and grid protection. Up to two circuit-breakers/ trip circuits are triggered by the m odule directly via relay outputs. The continuous m onitoring of grid harmonics up to the 50th harmonic can be used for direct responses as well as for evaluating the power quality. Item Item No. GMP23200017829-00 GMP232 00019063-00 The GMP232 module is provided with an integrated real-time data recorder for high-precision recording of up to 16 measuring channels during alarm/protection events. Error events are continuously recorded and stored within the module‘s internal memory along with precise time stamps. The internal time base of the module can be synchronized to an external time source (e.g. IEEE 1588 Precision Time Protocol), which supports the analysis of the data from spatially separated measurement and protection devices. The GMP232 is fully integrated into the Bachmann SolutionCenter. User-defined configurations are easily created and stored for later use. Both measured channel values and derived values are made available directly within the user interface. Commissioning and fault analysis are simplified with tabular, phasor, and time sequence displays. Event logs and recorded time sequences can be exported as CSV or COMTRADE file formats. The integrated simulation monitoring functions simplifies the configuration of protection and monitoring functions. Features: •Measurement of current, voltage, frequency, power, power factor, phase angle •Direct connection to input voltages up to 690 VL-L, RMS •Measurement of grid harmonics up to the 50th order (power quality) •Monitoring/Protection functions for grid and generator •Direct relay outputs for circuit-breaker/trip circuits •Integrated real-time data recorder •Integrated event logging •4Q energy counter •Measured value simulation 7 System Overview • Bachmann electronic GmbH • 05/2015 • Specification subject to change – the product’s characteristics are exclusively governed by the data of the respective user manual. Grid measurement module GMP232 – Grid measurement General Measurement channels 3 voltage, 3 current Sampling/resolution 20 kHz/16 Bit Digital relay outputs 2 changeover contacts Dimensions W x H x D 110 x 119 x 65 mm Weight 535 g Operation temperature -30 °C to +60 °C (-22 °F to 140 °F) Protection class 2, overvoltage category 3 Measurement Maximum rated voltage UL-L, RMS: 690 Vrms UL-N, RMS: 400 Vrms Voltage measuring range UL-L, RMS: 17.3 to 1030 Vrms, UL-N, RMS: 10 to 595 Vrms Voltage accuracy ≤ ±0.1 % Maximum rated current 5 Arms Current accuracy ≤ ±0.15 % Short-term overload (5x1 s, interval 300 s) 100 Arms Rated frequency 50/60 Hz, updated at each positive zero crossing Reference range 35 to 75 Hz Frequency accuracy/resolution 0.002 Hz/0.001 Hz Grid quality features Power quality Harmonic characteristics (THD, TDD) applied standard IEC61000-4-7 Harmonic amplitudes up to the 50th harmonic (voltage and current) Energy counter 4-quadrant counter, active and reactive, delivered and received Power measurement P, Q, S per phase and total (calculation methods: DIN40110-2, IEC61400-21) Power factor, rate of change of frequency (ROCOF), vector jump, current and voltage asymmetry, grid statistics Protection features Undervoltage, overvoltage U<, U<<, U>, U>> Overcurrent I>, I>> Underfrequency, overfrequency f<, f<<, f<<<, f>, f>>, f>>> Event logging SER (sequenece of events recorder) Digital fault recorder (DFR) 16 channels, 100 μs sampling rate, 40960 samples per channel, pretrigger function Reactive power undervoltage protection Q (U), ROCOF, vector jump, voltage asymmetry, current asymmetry, fault ride through: FRT, power quality monitoring: PQM Approvals/certificates General CE, UL/cUL, CCC Medium voltage directive BDEW:2008, FGW TR3:2011 (Rev. 22), FGW TR8:2011 (Rev. 5) Marine GL, DNV, LR, ABS, BV Others ENA ER G59/3:2013, IEEE Std. C37.90:2005 8 System Overview • Bachmann electronic GmbH • 05/2015 • Specification subject to change – the product’s characteristics are exclusively governed by the data of the respective user manual.