* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download PRD-ES-055 - Low Voltage Equipment
Index of electronics articles wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Regenerative circuit wikipedia , lookup
Integrated circuit wikipedia , lookup
Rectiverter wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Integrated Management System PRD-ES-055 LOW VOLTAGE EQUIPMENT Name Title Prepared by Vilas Tighare Senior Automation Engineer Projects Reviewed by Zaky Zeid Electrical Manager Projects Approved by Ahmed Al-Dhaheri Vice President Projects Sig. EMIRATES STEEL Low Voltage Equipment PRD-ES-055 CONTENTS 1. GENERAL 2. CIRCUIT BREAKERS 3. CONTACTORS 4. THERMAL OVERLOAD RELAYS 5. AUXILIARY RELAYS 6. TIME RELAYS 7. SPECIAL RELAYS 8. PUSH BUTTONS AND INDICATOR LIGHTS 9. MEASURING INDICATORS 10. FIELD DEVICES Issue No.: 01 2 of 5 Issue Date: 08.06.2011 EMIRATES STEEL Low Voltage Equipment 1. PRD-ES-055 GENERAL All low voltage (up to 1000V) equipment components shall be manufactured by a single reputable electrical company having worldwide after sales services (e.g. ABB, AEG, SIEMENS, GE, Schneider, Cutler Hammer). 2. CIRCUIT BREAKERS 2.1 RATED CURRENT HIGHER THAN 630A Circuit breakers for rated current higher than 630A shall be draw-out type air circuit breakers (ACBs) equipped with motor operating mechanism with stored energy feature. The ACBs shall comply as a minimum with IEC 60947; Low Voltage Switchgear and Controlgear. All circuit breakers shall have padlock facilities. Adjustable electronic short circuit and temperature compensated thermal overcurrent releases shall be fitted directly to the circuit breaker and automatically trip all 3 phases of the circuit breaker simultaneously when the adjusted threshold setting value is reached. The releases fitted shall be readily exchangeable. Adjustment of the releases shall be from the front of the panels without the necessity of withdrawing the circuit breaker portion from the fixed housing. For indication purposes each circuit breaker shall be provided with minimum 1 NO and 1 NC auxiliary contacts. 2.2 RATED CURRENT MAX. 630A Circuit breakers for rated current up to 630A shall be moulded case circuit breakers (MCCBs). The circuit breakers shall preferably be plug-in on a fixed base, or at least easily replaceable. In cases where they are used in motor starter units, the circuit breakers are to be installed into the cassettes of the starter units. The MCCBs shall comply as a minimum with IEC 60947; Low Voltage Switchgear and Controlgear. The MCCBs shall be rated to withstand and break the prospective full short circuit current without the need for replacement. 2.3 MINIATURE CIRCUIT BREAKERS Miniature circuit breakers (MCBs) shall be used in control and lighting circuits. They shall have Type C, D or K characteristics and minimum breaking capacity of 10 kA in compliance with IEC 60947-2 (IEC60947-4 for use with motor circuits). Issue No.: 01 3 of 5 Issue Date: 08.06.2011 EMIRATES STEEL Low Voltage Equipment 3. PRD-ES-055 CONTACTORS Contactors for AC and DC operation shall be air break electromagnetic type and shall be suitable for a minimum of 1 million operations and contactor size 00 for a minimum of 3 million operations. The contactors shall comply with IEC 60158-1. The coils of the contactors shall be rated for 110V -50Hz maximum. 4. THERMAL OVERLOAD RELAYS Thermal overload relays for motor starters shall incorporate protection against single phasing. They shall have adjustable settings and the range of adjustment shall be selected such that the motor may operate continuously at 100% rated current and such that inadvertent trips shall not occur during the motor start conditions. Contactors with ratings of 630A or larger shall be fitted with electronic overload relays. 5. AUXILIARY RELAYS The coils of auxiliary relays in AC-circuits shall be rated for 110V, 50Hz max. and 24V DC in case controlled directly by outputs of PLC subject to the switching limitations of the output. 6. TIME RELAYS Only electronic time relays shall be used. 7. SPECIAL RELAYS The Contractor shall submit technical details of all special relays proposed for the Purchaser’s approval. . 8. PUSH BUTTONS AND INDICATOR LIGHTS The mounting diameter of the devices shall be dia. 22mm and the rated operational current Ie/AC-1 shall be minimum 10A. Indicator lamps shall be of LED type. The equipment shall be suitable for operations in a typical steel works environment. 9. MEASURING INDICATORS All measuring indicators shall be installed in such a way that they can be read easily. The size of measuring indicators shall be 96 x 96mm with measuring accuracy to Class 1. Where LCD displays are used the character height shall be 8mm minimum. 10. FIELD DEVICES All field devices (limit switches, proximity switches, level switches, pressure switches, temperature switches, tachometers, etc.) shall comply with applicable IEC or recognised national standards standards. Issue No.: 01 4 of 5 Issue Date: 08.06.2011 EMIRATES STEEL Low Voltage Equipment Issue Status 01 Date 08/06/2011 Issue No.: 01 PRD-ES-055 Page / s Revision Details 5 Formatted as per ISO corporate standard 5 of 5 Issue Date: 08.06.2011