Installation and Operation Manual
SPS-3S
Multiprotocol FRAD/PAD
Packet Switch
SPS-3S
Multiprotocol FRAD/PAD Packet Switch
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD").
No part of this publication may be reproduced in any form whatsoever without prior written approval
by RAD Data Communications.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other
intellectual property or other proprietary rights relating to this manual and to the SPS-3S and any
software components contained therein are proprietary products of RAD protected under international
copyright law and shall be and remain solely with RAD.
SPS-3S is a registered trademark of RAD. No right, license, or interest to such trademark is granted
hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect
to such trademark.
You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the
SPS-3S. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute,
license, or sell any product that supports substantially similar functionality as the
SPS-3S, based on or derived in any way from the SPS-3S. Your undertaking in this paragraph shall
survive the termination of this Agreement.
This Agreement is effective upon your opening of the SPS-3S package and shall continue until
terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon
such termination by RAD, you agree to return to RAD the SPS-3S and all copies and portions thereof.
For further information contact RAD at the address below or contact your local distributor.
International Headquarters
RAD Data Communications Ltd.
North America Headquarters
RAD Data Communications Inc.
24 Raoul Wallenberg St.
Tel Aviv 69719 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
E-mail: [email protected]
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100, Toll free: 1-800-444-7234
Fax: (201) 529-5777
E-mail: [email protected]
© 1993–2006 RAD Data Communications Ltd.
Publication No. 159-200-10/06
Limited Warranty
RAD warrants to DISTRIBUTOR that the hardware in the SPS-3S to be delivered hereunder shall be
free of defects in material and workmanship under normal use and service for a period of twelve (12)
months following the date of shipment to DISTRIBUTOR.
If, during the warranty period, any component part of the equipment becomes defective by reason of
material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have
the option to choose the appropriate corrective action: a) supply a replacement part, or b) request
return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location.
In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs.
RAD shall be released from all obligations under its warranty in the event that the equipment has been
subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were
made by persons other than RAD's own authorized service personnel, unless such repairs by others
were made with the written consent of RAD.
The above warranty is in lieu of all other warranties, expressed or implied. There are no warranties
which extend beyond the face hereof, including, but not limited to, warranties of merchantability and
fitness for a particular purpose, and in no event shall RAD be liable for consequential damages.
RAD shall not be liable to any person for any special or indirect damages, including, but not limited to,
lost profits from any cause whatsoever arising from or in any way connected with the manufacture,
sale, handling, repair, maintenance or use of the SPS-3S, and in no event shall RAD's liability exceed
the purchase price of the SPS-3S.
DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating
to SPS-3S and for ensuring that replacements and other adjustments required in connection with the
said warranties are satisfactory.
Software components in the SPS-3S are provided "as is" and without warranty of any kind. RAD
disclaims all warranties including the implied warranties of merchantability and fitness for a particular
purpose. RAD shall not be liable for any loss of use, interruption of business or indirect, special,
incidental or consequential damages of any kind. In spite of the above RAD shall do its best to provide
error-free software products and shall offer free Software updates during the warranty period under
this Agreement.
RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims,
demands, or actions arising out of or relating to this Agreement and the SPS-3S shall not exceed the sum
paid to RAD for the purchase of the SPS-3S. In no event shall RAD be liable for any indirect, incidental,
consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the
possibility of such damages.
This Agreement shall be construed and governed in accordance with the laws of the State of Israel.
Product Disposal
To facilitate the reuse, recycling and other forms of recovery of waste
equipment in protecting the environment, the owner of this RAD product
is required to refrain from disposing of this product as unsorted municipal
waste at the end of its life cycle. Upon termination of the unit’s use,
customers should provide for its collection for reuse, recycling or other
form of environmentally conscientious disposal.
General Safety Instructions
The following instructions serve as a general guide for the safe installation and operation of
telecommunications products. Additional instructions, if applicable, are included inside the manual.
Safety Symbols
Warning
This symbol may appear on the equipment or in the text. It indicates
potential safety hazards regarding product operation or maintenance to
operator or service personnel.
Danger of electric shock! Avoid any contact with the marked surface while
the product is energized or connected to outdoor telecommunication lines.
.
Protective earth: the marked lug or terminal should be connected to the building
protective earth bus.
Warning
Some products may be equipped with a laser diode. In such cases, a label
with the laser class and other warnings as applicable will be attached near
the optical transmitter. The laser warning symbol may be also attached.
Please observe the following precautions:
• Before turning on the equipment, make sure that the fiber optic cable is
intact and is connected to the transmitter.
• Do not attempt to adjust the laser drive current.
• Do not use broken or unterminated fiber-optic cables/connectors or look
straight at the laser beam.
• The use of optical devices with the equipment will increase eye hazard.
• Use of controls, adjustments or performing procedures other than those
specified herein, may result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
In some cases, the users may insert their own SFP laser transceivers into the product. Users are alerted
that RAD cannot be held responsible for any damage that may result if non-compliant transceivers are
used. In particular, users are warned to use only agency approved products that comply with the local
laser safety regulations for Class 1 laser products.
Always observe standard safety precautions during installation, operation and maintenance of this
product. Only qualified and authorized service personnel should carry out adjustment, maintenance or
repairs to this product. No installation, adjustment, maintenance or repairs should be performed by
either the operator or the user.
Handling Energized Products
General Safety Practices
Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be
present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is
blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards
may still exist.
Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any
other metallic object that may come into contact with energized parts.
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is
provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is
provided on the product, it should be connected to the protective earth at all times, by a wire with a
diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and
cabinets.
Always make the ground connection first and disconnect it last. Do not connect telecommunication cables
to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the
ground.
Connection of AC Mains
Make sure that the electrical installation complies with local codes.
Always connect the AC plug to a wall socket with a protective ground.
The maximum permissible current capability of the branch distribution circuit that supplies power to the
product is 16A. The circuit breaker in the building installation should have high breaking capacity and must
operate at short-circuit current exceeding 35A.
Always connect the power cord first to the equipment and then to the wall socket. If a power switch is
provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in
case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the
building installation.
In cases when the power distribution system is IT type, the switch must disconnect both poles
simultaneously.
Connection of DC Mains
Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground.
Any single pole can be externally grounded.
Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply
to avoid short-circuits and fire hazards.
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to
qualified service and maintenance personnel.
Make sure that the DC supply is electrically isolated from any AC source and that the installation complies
with the local codes.
The maximum permissible current capability of the branch distribution circuit that supplies power to the
product is 16A. The circuit breaker in the building installation should have high breaking capacity and must
operate at short-circuit current exceeding 35A.
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the
circuit breaker of the panel board that services the equipment and switch it to the OFF position. When
connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the
positive pole and last the negative pole. Switch the circuit breaker back to the ON position.
A readily accessible disconnect device that is suitably rated and approved should be incorporated in the
building installation.
If the DC mains are floating, the switch must disconnect both poles simultaneously.
Connection of Data and Telecommunications Cables
Data and telecommunication interfaces are classified according to their safety status.
The following table lists the status of several standard interfaces. If the status of a given port differs from
the standard one, a notice will be given in the manual.
Ports
Safety Status
V.11, V.28, V.35, V.36, RS-530,
X.21, 10 BaseT, 100 BaseT,
Unbalanced E1, E2, E3, STM, DS-2,
DS-3, S-Interface ISDN, Analog voice
E&M
SELV
xDSL (without feeding voltage),
Balanced E1, T1, Sub E1/T1
TNV-1 Telecommunication Network Voltage-1:
FXS (Foreign Exchange Subscriber)
TNV-2 Telecommunication Network Voltage-2:
Safety Extra Low Voltage:
Ports which do not present a safety hazard. Usually
up to 30 VAC or 60 VDC.
Ports whose normal operating voltage is within the
limits of SELV, on which overvoltages from
telecommunications networks are possible.
Ports whose normal operating voltage exceeds the
limits of SELV (usually up to 120 VDC or telephone
ringing voltages), on which overvoltages from
telecommunication networks are not possible. These
ports are not permitted to be directly connected to
external telephone and data lines.
FXO (Foreign Exchange Office), xDSL
(with feeding voltage), U-Interface
ISDN
TNV-3 Telecommunication Network Voltage-3:
Ports whose normal operating voltage exceeds the
limits of SELV (usually up to 120 VDC or telephone
ringing voltages), on which overvoltages from
telecommunication networks are possible.
Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a
qualified safety engineer.
Always make sure that the equipment is grounded before connecting telecommunication cables. Do
not disconnect the ground connection before disconnecting all telecommunications cables.
Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables.
Extra caution should be exercised during thunderstorms.
When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The
earthing and bonding of the ground connections should comply with the local codes.
The telecommunication wiring in the building may be damaged or present a fire hazard in case of
contact between exposed external wires and the AC power lines. In order to reduce the risk, there are
restrictions on the diameter of wires in the telecom cables, between the equipment and the mating
connectors.
Caution
Attention
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords.
Pour réduire les risques s’incendie, utiliser seulement des conducteurs de
télécommunications 26 AWG ou de section supérieure.
Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such
cases, a notice will be given in the installation instructions.
Do not attempt to tamper with any carrier-provided equipment or connection hardware.
Electromagnetic Compatibility (EMC)
The equipment is designed and approved to comply with the electromagnetic regulations of major
regulatory bodies. The following instructions may enhance the performance of the equipment and will
provide better protection against excessive emission and better immunity against disturbances.
A good earth connection is essential. When installing the equipment in a rack, make sure to remove all
traces of paint from the mounting points. Use suitable lock-washers and torque. If an external
grounding lug is provided, connect it to the earth bus using braided wire as short as possible.
The equipment is designed to comply with EMC requirements when connecting it with unshielded
twisted pair (UTP) cables. However, the use of shielded wires is always recommended, especially for
high-rate data. In some cases, when unshielded wires are used, ferrite cores should be installed on
certain cables. In such cases, special instructions are provided in the manual.
Disconnect all wires which are not in permanent use, such as cables used for one-time configuration.
The compliance of the equipment with the regulations for conducted emission on the data lines is
dependent on the cable quality. The emission is tested for UTP with 80 dB longitudinal conversion loss
(LCL).
Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondary
protection against surges on the data lines. Primary protectors should be provided in the building
installation.
The equipment is designed to provide adequate protection against electro-static discharge (ESD).
However, it is good working practice to use caution when connecting cables terminated with plastic
connectors (without a grounded metal hood, such as flat cables) to sensitive data lines. Before
connecting such cables, discharge yourself by touching earth ground or wear an ESD preventive wrist
strap.
FCC-15 User Information
This equipment has been tested and found to comply with the limits of the Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the Installation and Operation manual, may cause harmful interference to the radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Canadian Emission Requirements
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing
Equipment Regulation.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
Warning per EN 55022 (CISPR-22)
Warning
This is a class A product. In a domestic environment, this product may cause
radio interference, in which case the user will be required to take adequate
measures.
Avertissement
Cet appareil est un appareil de Classe A. Dans un environnement résidentiel, cet
appareil peut provoquer des brouillages radioélectriques. Dans ces cas, il peut
être demandé à l’utilisateur de prendre les mesures appropriées.
Achtung
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können
bei Betrieb dieses Gerätes Rundfunkströrungen auftreten, in welchen Fällen der
Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Declaration of Conformity
Manufacturer's Name:
RAD Data Communications Ltd.
Manufacturer's Address:
24 Raoul Wallenberg St.
Tel Aviv 69719
Israel
Declares that the product:
Product Name:
SPS-3S
Conforms to the following standard(s) or other normative document(s):
EMC:
Safety:
EN 55022 (1994)
Limits and methods of measurement of radio disturbance
characteristics of information technology equipment.
EN 50082-1 (1992)
Electromagnetic compatibility – Generic immunity standards
for residential, commercial and light industry.
EN 60950 (1992/93)
Safety of information technology equipment, including
electrical business equipment.
Supplementary Information:
The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the Low
Voltage Directive 73/23/EEC. The product was tested in a typical configuration.
Tel Aviv, 7 November 1996
Haim Karshen
VP Quality
European Contact: RAD Data Communications GmbH, Otto-Hahn-Str. 28-30,
85521 Ottobrunn-Riemerling, Germany
Contents
Chapter 1. Introduction
1.1 Overview..................................................................................................................... 1-1
1.2 Technical Specifications............................................................................................... 1-2
Chapter 2. Installation
2.1 Introduction................................................................................................................. 2-1
2.2 Unpacking ................................................................................................................... 2-1
2.3 Site Requirements........................................................................................................ 2-2
Power................................................................................................................................... 2-2
Data Channel Connections ................................................................................................... 2-2
Main Links Connections........................................................................................................2-2
Front and Rear Panel Clearance ............................................................................................ 2-2
Ambient Requirements ......................................................................................................... 2-2
2.4 Hardware Configuration .............................................................................................. 2-3
General Information ............................................................................................................. 2-3
Internal Jumpers ................................................................................................................... 2-4
Interface Board ..................................................................................................................... 2-5
Jumper Setting Procedure .....................................................................................................2-6
2.5 Installation in 19" Racks ............................................................................................... 2-7
Installation of the Unit .......................................................................................................... 2-7
2.6 Cable Connections ...................................................................................................... 2-8
General ................................................................................................................................ 2-8
Asynchronous Data Channel Connections ............................................................................. 2-8
Synchronous Links Connection ............................................................................................. 2-8
Power Connection ................................................................................................................ 2-8
Chapter 3. Operation
3.1 General ....................................................................................................................... 3-1
3.2 Controls, Indicators and Connectors ............................................................................ 3-1
Front Panel ........................................................................................................................... 3-1
Rear Panel ............................................................................................................................ 3-3
3.3 Operating Instructions ................................................................................................. 3-3
General ................................................................................................................................ 3-3
Power-On ............................................................................................................................ 3-3
Normal Operation ................................................................................................................ 3-4
Power-Off ............................................................................................................................ 3-4
3.4 What to do in Case of Malfunction .............................................................................. 3-4
Preliminary Checks ............................................................................................................... 3-4
Troubleshooting.................................................................................................................... 3-4
Appendix A. Connector Pinouts
SPS-3S
i
Table of Contents
ii
Installation and Operation Manual
SPS-3S
Chapter 1
Introduction
1.1
Overview
SPS-3S is a FRAD/PAD packet switch that enables multiprotocol connection
between the enterprise headquarters and remote branches, and it also provides
packet switching capability for both X.25 and Frame Relay.
SPS-3S has three ports which support aggregate data rates up to 2 Mbps. Each port
can be configured to any of the following protocols: X.25, Frame Relay, HDLC,
STM, ASYNC (soft-selectable for each port), SNA/SDLC (for X version only) or
IP/SLIP (for X version only). Switching between ports is provided for X.25, Frame
Relay, SDLC and encapsulated protocols.
The ports can be V.24, V.35, X.21, V.36, DDS or RS-530. Link 1 can be ISDN-S or
IR-ETH. Interfaces for the ports can be DCE or DTE layer 1 (user configurable). An
optional DDS interface can be provided only on port 1 and is always DTE layer 1.
The SPS-3S supports a wide range of applications. For information on the SPS-3S
features and applications, refer to the RAD Packet Switching Applications Guide.
Figure 1-1. SPS-3S Unit
SPS-3S
Overview
1-1
Chapter 1 Introduction
1.2
Interfaces
Protocols
Control Port
1-2
Installation and Operation Manual
Technical Specifications
Number of ports
3 multiprotocol and 1 async port
Data Rate
Each link aggregates up to 2 Mbps
Interface
V.24, V.35, X.21, RS-530 (selected during
ordering) DDS for port 1 only
Connectors: Link 1 (DTE)
V.24
X.21
V.35
V.36
RS-530
IR-ETH
ISDN
DDS
25-pin D-type, female
25-pin D-type, female
25-pin D-type, female
25-pin D-type, female
25-pin D-type, female
10BaseT, UTP cable, RJ-45
S-interface, UTP cable, RJ-45
RJ-45, female (X version only)
Connectors: Link 2 and 3
(DTE or DCE)
V.24
X.21
V.35
V.36
RS-530
25-pin D-type, female
25-pin D-type, female
25-pin D-type, female
25-pin D-type, female
25-pin D-type, female
Compatibility
X.25, Frame Relay, HDLC, STM, ASYNC (softselectable for each port), SNA/SDLC (for X
version only), IP/SLIP (for X version only).
X.25
Complies with 1988 UTI X.25, LAP-B.
STM
Compatible with STM-4, STM-8, STM-16 and
STM-24 statistical multiplexers.
Frame Relay
Supports CLLM, LMI and ANSI PVC
management protocols; complies with ANSI
T1.606, T1.617 Annex D, T1.618, and UTI
Rec. Q.922 Annex A.
IP (X version only)
Supports IP encapsulation over X.25 network
(complies with RFC 1356) or Frame Relay
network (complies with RFC 1490). Supports
dial-up link for X.25 with X.32 protocols
Packet Size
Up to 4096 bytes for X.25
Up to 8192 bytes for other protocols
Data Rate
75 bps to 38.4 kbps
Flow Control
XON/XOFF
CTS/RTF
Command Mode
X.28, extended
Terminal Handling
Enhanced asynchronous terminal, handling
beyond X.3 requirements.
Technical Specifications
SPS-3S
Installation and Operation Manual
Chapter 1 Introduction
Interface
Compatible with AT&T PUB 62310: Standard
Digital Data Services, Channel Interface
Specifications
Connector
RJ-45 (8 pins)
Data Rates
4.8, 9.6, 19.2 and 56 kbps
Timing
Recovered from line signal
Locked to receive signal, internal oscillator
Attenuation
Up to 43 dB
Range
(AWG 24, 0.6 mm)
9.6 kbps: 6.5 miles (10.5 km)
19.2 kbps: 5 miles (8 km)
56 kbps: 4 miles (6.5 km)
Transmit BPV sequence
Zero suppression
Received BPV sequence
Out of service (OOS)
Out of frame (OOF)
DSU Loopback
General
Indicators
Power
Sync Channel 1
Sync Channel 2
Sync Channel 3
ACTIV Channel 1
ACTIV Channel 2
ACTIV Channel 3
Error
Overflow
Test
ACT
Power
Power
100 to 230 VAC (±10%)
47 to 63 Hz
Power Consumption
20W max
Height
42 mm (1.7 in)
Width
215 mm (8.5 in)
Depth
240 mm (9.4 in)
Weight
1.2 kg (2.6 lb)
Temperature
0°–45°C (32°–113°F)
Humidity
Up to 90%, non-condensing
DDS Links
(X version only)
Physical
Environment
SPS-3S
Technical Specifications
1-3
Chapter 1 Introduction
1-4
Technical Specifications
Installation and Operation Manual
SPS-3S
Chapter 2
Installation
2.1
Introduction
This chapter provides mechanical and electrical installation procedures and basic
operating procedures for SPS-3S.
SPS-3S is delivered completely assembled. It is designed for installation as a
desktop unit or mounted in a 19" rack.
After installing the unit, refer to the RAD Packet Switching Guide for system
configuration information and procedures.
In case a problem is encountered, refer to the RAD Packet Switching Guide for test
and diagnostics instructions.
2.2
Unpacking
A preliminary inspection of the equipment container should be made before
unpacking. Evidence of damage should be noted and reported immediately.
To unpack the equipment:
1. Place the container on a clean flat surface.
2. Cut all straps.
3. Open or remove top.
4. Take out the unit carefully and place it securely on a clean surface.
5. Inspect the product for damage. Report immediately any damage found.
SPS-3S
Unpacking
2-1
Chapter 2 Installation
Installation and Operation Manual
2.3
Site Requirements
Power
The SPS-3S unit should be installed within 1.5m (5 feet) of an easily accessible
grounded AC outlet capable of furnishing 115 or 230VAC, in accordance with the
nominal supply voltage of the unit.
Data Channel Connections
SPS-3S has an RJ-45 connector for the asynchronous data channel. Refer to the
RAD Packet Switching Guide for pin allocations.
Main Links Connections
SPS-3S has three main link connectors. The main links connector depends on the
ordered interface:
•
V24:
25-pin D-type, female connector
•
X.21:
25-pin D-type, female connector (via adapter cable)
•
V.35:
25-pin D-type, female connector (via adapter cable)
•
RS-530:
25-pin D-type, female connector
•
V.36:
25-pin D-type female connector (via adapter cable)
•
IR-ETH:
10BaseT, UTP cable, RJ-45
•
ISDN:
S-interface, UTP cable, RJ-45
•
DDS:
8-pin RJ-45, female connector.
Appendix A provides the pin allocations.
Front and Rear Panel Clearance
When the unit is installed in a 19" rack, allow at least 90 cm (36 inches) of frontal
clearance for operator access. Allow at least 10 cm (4 inches) clearance at the rear
of the unit for interface cable connections.
Ambient Requirements
The ambient operating temperature of the SPS-3S should be 0° to 45°C
(32° to 122°F), at a relative humidity of up to 90%, non-condensing.
2-2
Site Requirements
SPS-3S
Installation and Operation Manual
2.4
Chapter 2 Installation
Hardware Configuration
General Information
SPS-3S contains two different types of printed circuit boards. Figure 2-1 shows an
internal view of the unit with the different boards.
•
The main board contains most of the SPS-3S circuits, and has two jumpers.
•
Three main link interface boards for SPS-3S which determine the interface
type. The appropriate board is installed in the factory in accordance with your
order, and cannot be replaced by the customer. See the RAD Packet Switching
Guide for further details.
This paragraph provides information on the functions of the internal jumpers, and
provides step-by-step instructions for setting these jumpers. The default settings for
each jumper are also listed.
Note
The default settings of the SPS-3S jumpers are usually suitable for most applications.
Check the default positions explained below. If your requirements are different, set
the internal jumpers in accordance with your requirements before the installation.
All other configuration actions are performed using the SPS-3S command facility
after installation is completed. Detailed instructions for these operations appear in
the RAD Packet Switching Guide.
Figure 2-1. SPS-3S Internal Board
SPS-3S
Hardware Configuration
2-3
Chapter 2 Installation
Installation and Operation Manual
Internal Jumpers
In order to avoid the possibility of electrical shock, always disconnect the
power cable from mains before opening the SPS-3S.
Warning
The SPS-3S main board has a number of internal jumpers. Refer to Figure 2-2 and
use the following descriptions of the more important jumpers.
INIT - NOR jumper, JP25
The JP25 jumper is used to select the default set of configuration parameters
stored in the unit. The jumper has two positions:
•
NOR – Normal operation. SPS-3S uses the parameters selected by the user
during the last configuration session.
•
INIT – Initialization. Upon turn-on, SPS-3S loads the default configuration
(determined by the factory and common to all the SPS-3S units). To select the
default configuration, refer to the RAD Packet Switching Guide.
The factory setting is NOR.
JP1
JP1 is not used. It is for future applications only.
The JP1 factory setting is NORMAL-NVRAM.
JP21, JP22
JP21 and JP22are not used. It is for future applications only.
The factory setting for JP21 and JP22 is RTS.
JP2
This jumper is used to set the unit when an IR-ETH or U-INT interface is used.
•
IR-ETH
JP2 is shorted to pins 2 and 3 (towards the front panel)
•
U-INT
JP2 is shorted to pins 1 and 2 (towards the back panel)
The factory setting for JP2 is U-INT.
BRG1, BRG2, BRG3, JP4, JP5, JP6
These jumpers are in use when working with the X.21 interface in the DCE mode.
To work the X.21 interface in the DCE mode, the jumper must be connected in
accordance with the interface in use.
For example, if you are using the X.21 interface in DCE mode, JP4 (BRG2) must be
connected to Link 2. To work with Link 1, connect JP5 (BRG1). To work with
Link 3, connect JP3.
When working with the X.21 interface in DTE mode, the jumper must be
disconnected.
2-4
Hardware Configuration
SPS-3S
Installation and Operation Manual
Chapter 2 Installation
Figure 2-2. SPS-3S Identification of Internal Jumpers
Interface Board
SPS-3S is available with four types of removable interface boards. Port 1 of the unit
is available as DDS for DDS CSU/DSU interface.
The interface board types are:
SPS-3S
•
V.24 (RS-232) interface
•
V.35 interface
•
RS-530 (V.36) interface
•
X.21 interface
•
IR-ETH
•
ISDN
•
DDS CSU/DSU interface.
Hardware Configuration
2-5
Chapter 2 Installation
Warning
Installation and Operation Manual
In order to avoid the possibility of electrical shock, always disconnect the
power cable from wall plug before opening the SPS-3S.
Each interface board can be configured as DCE or DTE by changing the main
jumper. The main jumper consists of multiple jumpers that must be changed
together. Each board is marked DCE DTE. The UI-X21 interface board is shown
in Figure 2-3.
Figure 2-3. UI-232 Interface Board
The interface board determines the physical layer configuration of a SPS-3S link.
When the board is set as DTE, the link must be used with a flat cable to connect to
a terminal. The link receives its clock from outside and the clock parameter must
be configured as external clock.
When the board is set as DCE, the link uses the internal clock, and the clock
parameter must be configured as internal clock (for more information, see the
RAD Packet Switching Guide).
Jumper Setting Procedure
In order to avoid the possibility of electrical shock, always disconnect the
power cable from the wall plug before opening the unit.
Warning
To access the printed circuit board of SPS-3S, loosen screws on the bottom of the
unit and remove the top cover.
Refer to Figure 2-2 or Figure 2-3and identify jumper locations and settings. Change
settings as required.
Replace the SPS-3S cover, gently push it down until it clips into place and fasten
screws.
2-6
Hardware Configuration
SPS-3S
Installation and Operation Manual
2.5
Chapter 2 Installation
Installation in 19" Racks
SPS-3S can be installed in 19" racks. Unit height corresponds to 1U (1.75"). The
width of the unit is slightly less than the available mounting width.
An adapter kit provides the hardware necessary for installation of the unit in 19"
racks. The paragraph below provides step-by-step instructions for this procedure.
Disconnect the units from AC power while performing the following
procedures.
Warning
Installation of the Unit
The rack adapter kit for the installation includes two long-arm brackets. The
brackets are fastened by means of screws to the two side walls of the case. The
installation of SPS-3S is shown in Figure 2-4.
To prepare the unit for rack installation, attach the two brackets to the side walls of
the unit. Each bracket is fastened by means of two screws (with flat washers),
which are inserted into the two front holes on the side wall (nuts are already in
place, on the inner side of the wall).
After attaching the brackets, the unit is ready for installation in the 19" rack. Fasten
the brackets to the side rails of the 19" rack by means of four screws (not included
in the kit), two on each side.
Figure 2-4. Installation of SPS-3S in 19" Rack
SPS-3S
Installation in 19" Racks
2-7
Chapter 2 Installation
Installation and Operation Manual
2.6
Cable Connections
General
SPS-3S has three connectors located on the rear panel that serve the synchronous
links, and an RJ-45 connector located on the front panel for the asynchronous data
channels.
Asynchronous Data Channel Connections
The SPS-3S channel interfaces are configured as data communication equipment
(DCE) interfaces, thereby allowing direct connection, via RS-232 port cables, to
data terminal equipment (DTE). When modems are used to extend the range (tailend circuits), cross-over cables are required. Channel interfaces are asynchronous,
therefore clock signals are neither supported, or required.
The Packet Switching Guide lists pin allocations in SPS-3S data channel connectors,
and provides typical wiring diagrams for straight-through and cross-over cables.
Synchronous Links Connection
Each interface board can be configured as DCE or DTE by changing the main
jumper. The main jumper consists of multiple jumpers that must be changed
together. Each board is marked DCE DTE. The X.25 link connectors type
depends on the SPS-3S interface:
•
V.24:
25-pin D-type, female connector
•
X.21:
25-pin D-type, female connector (via adapter cable)
•
V.35:
25-pin D-type, female connector (via adapter cable)
•
V.36:
25-pin D-type, female connector (via adapter cable)
•
RS-530:
25-pin D-type, female connector
•
IR-ETH:
10BaseT, UTP cable, RJ-45
•
ISDN
S-interface, UTP cable, RJ-45
•
DDS:
8-pin RJ-45, female connector.
Appendix A provides the pin allocations.
Note
The user data cables and the synchronous links cables should be shielded, in order
to comply with FCC rules. The SPS-3S and its data interfaces will work well even if
the cables are not shielded, but some radio interference may occur.
Power Connection
AC power should be supplied to the SPS-3S through the 5 feet (1.5m) power cable
terminated by a standard 3-prong plug. Connect the cable between the AC mains
connector on the SPS-3S rear panel and a standard grounded AC outlet.
2-8
Cable Connections
SPS-3S
Installation and Operation Manual
Warning
Chapter 2 Installation
BEFORE APPLYING POWER TO THIS UNIT, the protective earth terminals of
this instrument must be connected to the protective ground conductor of the
(mains) power cord. The mains plug should only be inserted in a socket outlet
provided with a protective earth contact. The protective action must not be
negated by use of an extension cord (power cable) without a protective
conductor (grounding).
Make sure that only fuses with the required rated current, as marked on the
SPS-3S rear panel, are used for replacement. The use of repaired fuses and
the short-circuiting of fuse holders must be avoided.
Whenever it is likely that the protection offered by fuses has been impaired,
the instrument must be made inoperative and be secured against any
unintended operation.
Any interruption of the protective (grounding) conductor (inside or outside the
unit) or disconnecting the protective earth terminal can make this unit
dangerous. Intentional interruption is prohibited.
SPS-3S
Cable Connections
2-9
Chapter 2 Installation
2-10
Cable Connections
Installation and Operation Manual
SPS-3S
Chapter 3
Operation
3.1
General
SPS-3S supports a wide range of applications. These include:
•
Connection of a bridge/router using HDLC encapsulation over Frame Relay
•
Encapsulating private X.25 over Frame Relay networks
•
Connecting SDLC/QLLC/LLC environment T-PADs and FEPs over X.25 or
Frame Relay Networks
•
Providing interfaces to DDS Networks
•
SLIP communication and IP encapsulation over Frame Relay or X.25 protocols.
For more detailed configuration information, refer to the RAD Packet Switching
Guide and RAD Packet Switching Applications Guide.
3.2
Controls, Indicators and Connectors
Front Panel
Table 3-1 lists the functions of the SPS-3S front panel indicators and connectors.
The numbers under the heading “Item” refer to the identification numbers in
Figure 3-1.
Figure 3-1. SPS-3S Front Panel
SPS-3S
Controls, Indicators and Connectors
3-1
Chapter 3 Operation
Installation and Operation Manual
Table 3-1. SPS-3S Controls, Indicators and Connectors
Item
Control, Indicator or
Connector
Function
1
PWR Indicator
Lights up when SPS-3S is powered.
2
Main Links Activity Indicators
Indicators, one for each main link, light up
when the corresponding link is active
(receives or transmits frames).
3
Channel Activity Indicator
Indicator lights up when the channel is
active (receives or transmits data).
4
SYN Indicators
Indicators, one for each main link, indicate
synchronization status.
Condition:
Indication:
Off
SPS-3S is not powered
On
SPS-3S is powered and
synchronized with the
corresponding peer.
Flashing
SPS-3S is powered but
(Continuous) not synchronized with
the corresponding
peer.
3-2
5
ERR Indicator
Lights up when a hardware malfunction is
detected during the self-test automatically
performed upon power-up, or after
pressing the RESET push-button.
6
OVF Indicator
Lights up when the SPS-3S buffers are full.
In a properly designed system, this
condition usually indicates that one of the
units connected to the unit does not
respond to the flow control commands
sent by SPS-3S, a condition that could be
caused by incorrect configuration of the
unit.
7
TEST Indicator
Lights up to indicate that SPS-3S is in
diagnostics mode (one of the test loops
active). In either case, traffic is interrupted.
8
Channel Connector
Connection to the SPS-3S channel.
Controls, Indicators and Connectors
SPS-3S
Installation and Operation Manual
Chapter 3 Operation
Rear Panel
Table 3-2 lists the functions of the SPS-3S rear panel controls and connectors. The
numbers under the heading “Item” refer to the identification numbers in
Figure 3-2.
Figure 3-2. SPS-3S Rear Panel Controls and Connectors
Table 3-2. SPS-3S Rear Panel Controls and Connectors
Item
Control or Connector
Function
1
Power Connector
AC power connector with integral
fuse
2
Synchronous Links Connectors
Connection to synchronous link
3.3
Operating Instructions
General
After being prepared for operation as explained above, SPS-3S normally operates
unattended. Operator intervention is only required when the unit is set up for the
first time or must be adapted to new operational requirements.
Note
SPS-3S configuration is stored in a non-volatile memory, and is not affected when
power is turned off.
Power-On
Connect the power cable to the unit's rear power connector; the PWR indicator
should light up. All the indicators on SPS-3S should flash, according to the default.
Check that after a short interval (during which SPS-3S performs self-test), the ERR,
OVF and TEST indicators are extinguished.
SPS-3S
Operating Instructions
3-3
Chapter 3 Operation
Installation and Operation Manual
Normal Operation
During normal operation, the PWR and SYNC indicators should light up
continuously and the TEST, OVF and ERR indicators must remain off.
Channel activity indicators flash according to the traffic load, and are extinguished
when the channel is idle.
Power-Off
To turn off the unit, disconnect its power cable from the mains.
3.4
What to do in Case of Malfunction
Preliminary Checks
In case a problem occurs, the following actions will help you return the to normal
operation.
•
Check that the unit is powered (PWR indicator should light up).
•
Check that cables are properly connected.
•
Check that the equipment connected to the unit is powered and operates
normally.
•
Check the LED indicators.
•
Check the configuration of SPS-3S and that of the remote PAD or switch
correspond to the requirements of the equipment connected to its channels.
Troubleshooting
In case the preliminary checks do not correct the problem, press RESET or turn the
unit off, and then turn it on again. If the problem repeats, refer to the RAD Packet
Switching Guide for additional operations.
3-4
What to do in Case of Malfunction
SPS-3S
Appendix A
Connector Pinouts
This appendix provides information needed for the SPS-3S interface connections.
The information presented in this appendix includes a description of the Control
connector, connector pin functions and where applicable – the recommended
wiring for relevant adapter cables.
A.1
Interface Connectors
X.21 Port Pinouts
V.24 Port Pinouts
SPS-3S
Interface Connectors
A-1
Appendix A Connector Pinouts
Installation and Operation Manual
V.35 Port Pinouts
V.36 Port Pinouts
A-2
Interface Connectors
SPS-3S
Installation and Operation Manual
Appendix A Connector Pinouts
RS-530 Port Pinouts
A.2
Control Connector
The control connector of SPS-3S is an RJ-45 8-pin female connector with a serial
RS-232 DCE interface, intended for connection to an ASCII-based terminal.
Connector pin functions are listed in Table A-1.
•
To connect a supervision terminal having a 9-pin connector to the control
connector, use the appropriate adapter cable (CBL-RJ45/D9/F/STR or
CBL-RJ45/D9/M/STR, supplied). Figure A-1 shows the wiring diagram of this
cable.
Table A-1. RJ-45 Control Connector Pin Functions
Pin
Function
1
GND
2
Not connected
3
Receive Data (RXD) from terminal
4
Not connected
5
Transmit Data (TXD) to terminal
6
Not connected
7
GND
8
Not connected
Terminal Control Table
The terminal control port cable has an 8-pin RJ-45 connector on one side, and a
9-pin, D-type, female connector on the other side.
SPS-3S
Control Connector
A-3
Appendix A Connector Pinouts
Installation and Operation Manual
Figure A-1. Wiring RJ-45 to DB-9 Adapter Cable (CBL-RJ45/DB9/F/STR)
A-4
Control Connector
SPS-3S
24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-6458181, Fax: +972-3-6483331, +972-3-6498250
E-mail: [email protected], Web site: www.rad.com
Customer Response Form
RAD Data Communications would like your help in improving its product documentation.
Please complete and return this form by mail or by fax or send us an e-mail with your
comments.
Thank you for your assistance!
SPS-3S
Manual Name: ______________________________________________________________
159-200-10/06
Publication Number: __________________________________________________________
Please grade the manual according to the following factors:
Installation instructions
Operating instructions
Manual organization
Illustrations
The manual as a whole
Excellent
Good
Fair
Poor
Very Poor
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
ˆ
What did you like about the manual?
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
Error Report
Type of Error(s)
ˆ
Incompatibility with product
or Problem(s):
ˆ
Difficulty in understanding text
ˆ
Regulatory information (Safety, Compliance, Warnings, etc.)
ˆ
Difficulty in finding needed information
ˆ
Missing information
ˆ
Illogical flow of information
ˆ
Style (spelling, grammar, references, etc.)
ˆ
Appearance
ˆ
Other _________
Please list the exact page numbers with the error(s), detail the errors you found (information missing,
unclear or inadequately explained, etc.) and attach the page to your fax, if necessary.
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
Please add any comments or suggestions you may have.
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
You are:
ˆ
Distributor
ˆ
End user
ˆ
VAR
ˆ
Other ________________________
Who is your distributor?
_______________________________
Your name and company: ___________________________________________________________
Job title: __________________________________________________________________________
Address: __________________________________________________________________________
Direct telephone number and extension: _______________________________________________
Fax number: ______________________________________________________________________
E-mail: _____________________________________________________________________
www.rad.com
INTERNATIONAL HEADQUARTERS:
24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181
Fax: 972-3-6498250, 972-3-6474436, Email: [email protected]
NORTH AMERICA HEADQUARTERS:
900 Corporate Drive, Mahwah, N.J. 07430, Tel: (201) 529-1100
Toll Free: 1-800-444-7234, Fax: (201) 529-5777, Email: [email protected]
Publication No. 159-200-10/06