* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SPS-3S - RADProductsOnline, Buy RAD Products Online at Great
Switched-mode power supply wikipedia , lookup
Ground (electricity) wikipedia , lookup
Fault tolerance wikipedia , lookup
Mains electricity wikipedia , lookup
Power over Ethernet wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Distribution management system wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Rectiverter wikipedia , lookup
Installation and Operation Manual SPS-3S Multiprotocol FRAD/PAD Packet Switch SPS-3S Multiprotocol FRAD/PAD Packet Switch Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the SPS-3S and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD. SPS-3S is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the SPS-3S. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the SPS-3S, based on or derived in any way from the SPS-3S. Your undertaking in this paragraph shall survive the termination of this Agreement. This Agreement is effective upon your opening of the SPS-3S package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the SPS-3S and all copies and portions thereof. For further information contact RAD at the address below or contact your local distributor. International Headquarters RAD Data Communications Ltd. North America Headquarters RAD Data Communications Inc. 24 Raoul Wallenberg St. Tel Aviv 69719 Israel Tel: 972-3-6458181 Fax: 972-3-6498250 E-mail: [email protected] 900 Corporate Drive Mahwah, NJ 07430 USA Tel: (201) 529-1100, Toll free: 1-800-444-7234 Fax: (201) 529-5777 E-mail: [email protected] © 1993–2006 RAD Data Communications Ltd. Publication No. 159-200-10/06 Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the SPS-3S to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the appropriate corrective action: a) supply a replacement part, or b) request return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location. In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs. RAD shall be released from all obligations under its warranty in the event that the equipment has been subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were made by persons other than RAD's own authorized service personnel, unless such repairs by others were made with the written consent of RAD. The above warranty is in lieu of all other warranties, expressed or implied. There are no warranties which extend beyond the face hereof, including, but not limited to, warranties of merchantability and fitness for a particular purpose, and in no event shall RAD be liable for consequential damages. RAD shall not be liable to any person for any special or indirect damages, including, but not limited to, lost profits from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, repair, maintenance or use of the SPS-3S, and in no event shall RAD's liability exceed the purchase price of the SPS-3S. DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating to SPS-3S and for ensuring that replacements and other adjustments required in connection with the said warranties are satisfactory. Software components in the SPS-3S are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of use, interruption of business or indirect, special, incidental or consequential damages of any kind. In spite of the above RAD shall do its best to provide error-free software products and shall offer free Software updates during the warranty period under this Agreement. RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this Agreement and the SPS-3S shall not exceed the sum paid to RAD for the purchase of the SPS-3S. In no event shall RAD be liable for any indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the possibility of such damages. This Agreement shall be construed and governed in accordance with the laws of the State of Israel. Product Disposal To facilitate the reuse, recycling and other forms of recovery of waste equipment in protecting the environment, the owner of this RAD product is required to refrain from disposing of this product as unsorted municipal waste at the end of its life cycle. Upon termination of the unit’s use, customers should provide for its collection for reuse, recycling or other form of environmentally conscientious disposal. General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols Warning This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel. Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines. . Protective earth: the marked lug or terminal should be connected to the building protective earth bus. Warning Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions: • Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter. • Do not attempt to adjust the laser drive current. • Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam. • The use of optical devices with the equipment will increase eye hazard. • Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure. ATTENTION: The laser beam may be invisible! In some cases, the users may insert their own SFP laser transceivers into the product. Users are alerted that RAD cannot be held responsible for any damage that may result if non-compliant transceivers are used. In particular, users are warned to use only agency approved products that comply with the local laser safety regulations for Class 1 laser products. Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user. Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts. Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets. Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground. Connection of AC Mains Make sure that the electrical installation complies with local codes. Always connect the AC plug to a wall socket with a protective ground. The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A. Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation. In cases when the power distribution system is IT type, the switch must disconnect both poles simultaneously. Connection of DC Mains Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded. Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards. DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel. Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes. The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A. Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation. If the DC mains are floating, the switch must disconnect both poles simultaneously. Connection of Data and Telecommunications Cables Data and telecommunication interfaces are classified according to their safety status. The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual. Ports Safety Status V.11, V.28, V.35, V.36, RS-530, X.21, 10 BaseT, 100 BaseT, Unbalanced E1, E2, E3, STM, DS-2, DS-3, S-Interface ISDN, Analog voice E&M SELV xDSL (without feeding voltage), Balanced E1, T1, Sub E1/T1 TNV-1 Telecommunication Network Voltage-1: FXS (Foreign Exchange Subscriber) TNV-2 Telecommunication Network Voltage-2: Safety Extra Low Voltage: Ports which do not present a safety hazard. Usually up to 30 VAC or 60 VDC. Ports whose normal operating voltage is within the limits of SELV, on which overvoltages from telecommunications networks are possible. Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are not possible. These ports are not permitted to be directly connected to external telephone and data lines. FXO (Foreign Exchange Office), xDSL (with feeding voltage), U-Interface ISDN TNV-3 Telecommunication Network Voltage-3: Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are possible. Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a qualified safety engineer. Always make sure that the equipment is grounded before connecting telecommunication cables. Do not disconnect the ground connection before disconnecting all telecommunications cables. Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms. When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections should comply with the local codes. The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors. Caution Attention To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure. Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions. Do not attempt to tamper with any carrier-provided equipment or connection hardware. Electromagnetic Compatibility (EMC) The equipment is designed and approved to comply with the electromagnetic regulations of major regulatory bodies. The following instructions may enhance the performance of the equipment and will provide better protection against excessive emission and better immunity against disturbances. A good earth connection is essential. When installing the equipment in a rack, make sure to remove all traces of paint from the mounting points. Use suitable lock-washers and torque. If an external grounding lug is provided, connect it to the earth bus using braided wire as short as possible. The equipment is designed to comply with EMC requirements when connecting it with unshielded twisted pair (UTP) cables. However, the use of shielded wires is always recommended, especially for high-rate data. In some cases, when unshielded wires are used, ferrite cores should be installed on certain cables. In such cases, special instructions are provided in the manual. Disconnect all wires which are not in permanent use, such as cables used for one-time configuration. The compliance of the equipment with the regulations for conducted emission on the data lines is dependent on the cable quality. The emission is tested for UTP with 80 dB longitudinal conversion loss (LCL). Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondary protection against surges on the data lines. Primary protectors should be provided in the building installation. The equipment is designed to provide adequate protection against electro-static discharge (ESD). However, it is good working practice to use caution when connecting cables terminated with plastic connectors (without a grounded metal hood, such as flat cables) to sensitive data lines. Before connecting such cables, discharge yourself by touching earth ground or wear an ESD preventive wrist strap. FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the Installation and Operation manual, may cause harmful interference to the radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Warning per EN 55022 (CISPR-22) Warning This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures. Avertissement Cet appareil est un appareil de Classe A. Dans un environnement résidentiel, cet appareil peut provoquer des brouillages radioélectriques. Dans ces cas, il peut être demandé à l’utilisateur de prendre les mesures appropriées. Achtung Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkströrungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist. Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel Declares that the product: Product Name: SPS-3S Conforms to the following standard(s) or other normative document(s): EMC: Safety: EN 55022 (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment. EN 50082-1 (1992) Electromagnetic compatibility – Generic immunity standards for residential, commercial and light industry. EN 60950 (1992/93) Safety of information technology equipment, including electrical business equipment. Supplementary Information: The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC. The product was tested in a typical configuration. Tel Aviv, 7 November 1996 Haim Karshen VP Quality European Contact: RAD Data Communications GmbH, Otto-Hahn-Str. 28-30, 85521 Ottobrunn-Riemerling, Germany Contents Chapter 1. Introduction 1.1 Overview..................................................................................................................... 1-1 1.2 Technical Specifications............................................................................................... 1-2 Chapter 2. Installation 2.1 Introduction................................................................................................................. 2-1 2.2 Unpacking ................................................................................................................... 2-1 2.3 Site Requirements........................................................................................................ 2-2 Power................................................................................................................................... 2-2 Data Channel Connections ................................................................................................... 2-2 Main Links Connections........................................................................................................2-2 Front and Rear Panel Clearance ............................................................................................ 2-2 Ambient Requirements ......................................................................................................... 2-2 2.4 Hardware Configuration .............................................................................................. 2-3 General Information ............................................................................................................. 2-3 Internal Jumpers ................................................................................................................... 2-4 Interface Board ..................................................................................................................... 2-5 Jumper Setting Procedure .....................................................................................................2-6 2.5 Installation in 19" Racks ............................................................................................... 2-7 Installation of the Unit .......................................................................................................... 2-7 2.6 Cable Connections ...................................................................................................... 2-8 General ................................................................................................................................ 2-8 Asynchronous Data Channel Connections ............................................................................. 2-8 Synchronous Links Connection ............................................................................................. 2-8 Power Connection ................................................................................................................ 2-8 Chapter 3. Operation 3.1 General ....................................................................................................................... 3-1 3.2 Controls, Indicators and Connectors ............................................................................ 3-1 Front Panel ........................................................................................................................... 3-1 Rear Panel ............................................................................................................................ 3-3 3.3 Operating Instructions ................................................................................................. 3-3 General ................................................................................................................................ 3-3 Power-On ............................................................................................................................ 3-3 Normal Operation ................................................................................................................ 3-4 Power-Off ............................................................................................................................ 3-4 3.4 What to do in Case of Malfunction .............................................................................. 3-4 Preliminary Checks ............................................................................................................... 3-4 Troubleshooting.................................................................................................................... 3-4 Appendix A. Connector Pinouts SPS-3S i Table of Contents ii Installation and Operation Manual SPS-3S Chapter 1 Introduction 1.1 Overview SPS-3S is a FRAD/PAD packet switch that enables multiprotocol connection between the enterprise headquarters and remote branches, and it also provides packet switching capability for both X.25 and Frame Relay. SPS-3S has three ports which support aggregate data rates up to 2 Mbps. Each port can be configured to any of the following protocols: X.25, Frame Relay, HDLC, STM, ASYNC (soft-selectable for each port), SNA/SDLC (for X version only) or IP/SLIP (for X version only). Switching between ports is provided for X.25, Frame Relay, SDLC and encapsulated protocols. The ports can be V.24, V.35, X.21, V.36, DDS or RS-530. Link 1 can be ISDN-S or IR-ETH. Interfaces for the ports can be DCE or DTE layer 1 (user configurable). An optional DDS interface can be provided only on port 1 and is always DTE layer 1. The SPS-3S supports a wide range of applications. For information on the SPS-3S features and applications, refer to the RAD Packet Switching Applications Guide. Figure 1-1. SPS-3S Unit SPS-3S Overview 1-1 Chapter 1 Introduction 1.2 Interfaces Protocols Control Port 1-2 Installation and Operation Manual Technical Specifications Number of ports 3 multiprotocol and 1 async port Data Rate Each link aggregates up to 2 Mbps Interface V.24, V.35, X.21, RS-530 (selected during ordering) DDS for port 1 only Connectors: Link 1 (DTE) V.24 X.21 V.35 V.36 RS-530 IR-ETH ISDN DDS 25-pin D-type, female 25-pin D-type, female 25-pin D-type, female 25-pin D-type, female 25-pin D-type, female 10BaseT, UTP cable, RJ-45 S-interface, UTP cable, RJ-45 RJ-45, female (X version only) Connectors: Link 2 and 3 (DTE or DCE) V.24 X.21 V.35 V.36 RS-530 25-pin D-type, female 25-pin D-type, female 25-pin D-type, female 25-pin D-type, female 25-pin D-type, female Compatibility X.25, Frame Relay, HDLC, STM, ASYNC (softselectable for each port), SNA/SDLC (for X version only), IP/SLIP (for X version only). X.25 Complies with 1988 UTI X.25, LAP-B. STM Compatible with STM-4, STM-8, STM-16 and STM-24 statistical multiplexers. Frame Relay Supports CLLM, LMI and ANSI PVC management protocols; complies with ANSI T1.606, T1.617 Annex D, T1.618, and UTI Rec. Q.922 Annex A. IP (X version only) Supports IP encapsulation over X.25 network (complies with RFC 1356) or Frame Relay network (complies with RFC 1490). Supports dial-up link for X.25 with X.32 protocols Packet Size Up to 4096 bytes for X.25 Up to 8192 bytes for other protocols Data Rate 75 bps to 38.4 kbps Flow Control XON/XOFF CTS/RTF Command Mode X.28, extended Terminal Handling Enhanced asynchronous terminal, handling beyond X.3 requirements. Technical Specifications SPS-3S Installation and Operation Manual Chapter 1 Introduction Interface Compatible with AT&T PUB 62310: Standard Digital Data Services, Channel Interface Specifications Connector RJ-45 (8 pins) Data Rates 4.8, 9.6, 19.2 and 56 kbps Timing Recovered from line signal Locked to receive signal, internal oscillator Attenuation Up to 43 dB Range (AWG 24, 0.6 mm) 9.6 kbps: 6.5 miles (10.5 km) 19.2 kbps: 5 miles (8 km) 56 kbps: 4 miles (6.5 km) Transmit BPV sequence Zero suppression Received BPV sequence Out of service (OOS) Out of frame (OOF) DSU Loopback General Indicators Power Sync Channel 1 Sync Channel 2 Sync Channel 3 ACTIV Channel 1 ACTIV Channel 2 ACTIV Channel 3 Error Overflow Test ACT Power Power 100 to 230 VAC (±10%) 47 to 63 Hz Power Consumption 20W max Height 42 mm (1.7 in) Width 215 mm (8.5 in) Depth 240 mm (9.4 in) Weight 1.2 kg (2.6 lb) Temperature 0°–45°C (32°–113°F) Humidity Up to 90%, non-condensing DDS Links (X version only) Physical Environment SPS-3S Technical Specifications 1-3 Chapter 1 Introduction 1-4 Technical Specifications Installation and Operation Manual SPS-3S Chapter 2 Installation 2.1 Introduction This chapter provides mechanical and electrical installation procedures and basic operating procedures for SPS-3S. SPS-3S is delivered completely assembled. It is designed for installation as a desktop unit or mounted in a 19" rack. After installing the unit, refer to the RAD Packet Switching Guide for system configuration information and procedures. In case a problem is encountered, refer to the RAD Packet Switching Guide for test and diagnostics instructions. 2.2 Unpacking A preliminary inspection of the equipment container should be made before unpacking. Evidence of damage should be noted and reported immediately. To unpack the equipment: 1. Place the container on a clean flat surface. 2. Cut all straps. 3. Open or remove top. 4. Take out the unit carefully and place it securely on a clean surface. 5. Inspect the product for damage. Report immediately any damage found. SPS-3S Unpacking 2-1 Chapter 2 Installation Installation and Operation Manual 2.3 Site Requirements Power The SPS-3S unit should be installed within 1.5m (5 feet) of an easily accessible grounded AC outlet capable of furnishing 115 or 230VAC, in accordance with the nominal supply voltage of the unit. Data Channel Connections SPS-3S has an RJ-45 connector for the asynchronous data channel. Refer to the RAD Packet Switching Guide for pin allocations. Main Links Connections SPS-3S has three main link connectors. The main links connector depends on the ordered interface: • V24: 25-pin D-type, female connector • X.21: 25-pin D-type, female connector (via adapter cable) • V.35: 25-pin D-type, female connector (via adapter cable) • RS-530: 25-pin D-type, female connector • V.36: 25-pin D-type female connector (via adapter cable) • IR-ETH: 10BaseT, UTP cable, RJ-45 • ISDN: S-interface, UTP cable, RJ-45 • DDS: 8-pin RJ-45, female connector. Appendix A provides the pin allocations. Front and Rear Panel Clearance When the unit is installed in a 19" rack, allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at least 10 cm (4 inches) clearance at the rear of the unit for interface cable connections. Ambient Requirements The ambient operating temperature of the SPS-3S should be 0° to 45°C (32° to 122°F), at a relative humidity of up to 90%, non-condensing. 2-2 Site Requirements SPS-3S Installation and Operation Manual 2.4 Chapter 2 Installation Hardware Configuration General Information SPS-3S contains two different types of printed circuit boards. Figure 2-1 shows an internal view of the unit with the different boards. • The main board contains most of the SPS-3S circuits, and has two jumpers. • Three main link interface boards for SPS-3S which determine the interface type. The appropriate board is installed in the factory in accordance with your order, and cannot be replaced by the customer. See the RAD Packet Switching Guide for further details. This paragraph provides information on the functions of the internal jumpers, and provides step-by-step instructions for setting these jumpers. The default settings for each jumper are also listed. Note The default settings of the SPS-3S jumpers are usually suitable for most applications. Check the default positions explained below. If your requirements are different, set the internal jumpers in accordance with your requirements before the installation. All other configuration actions are performed using the SPS-3S command facility after installation is completed. Detailed instructions for these operations appear in the RAD Packet Switching Guide. Figure 2-1. SPS-3S Internal Board SPS-3S Hardware Configuration 2-3 Chapter 2 Installation Installation and Operation Manual Internal Jumpers In order to avoid the possibility of electrical shock, always disconnect the power cable from mains before opening the SPS-3S. Warning The SPS-3S main board has a number of internal jumpers. Refer to Figure 2-2 and use the following descriptions of the more important jumpers. INIT - NOR jumper, JP25 The JP25 jumper is used to select the default set of configuration parameters stored in the unit. The jumper has two positions: • NOR – Normal operation. SPS-3S uses the parameters selected by the user during the last configuration session. • INIT – Initialization. Upon turn-on, SPS-3S loads the default configuration (determined by the factory and common to all the SPS-3S units). To select the default configuration, refer to the RAD Packet Switching Guide. The factory setting is NOR. JP1 JP1 is not used. It is for future applications only. The JP1 factory setting is NORMAL-NVRAM. JP21, JP22 JP21 and JP22are not used. It is for future applications only. The factory setting for JP21 and JP22 is RTS. JP2 This jumper is used to set the unit when an IR-ETH or U-INT interface is used. • IR-ETH JP2 is shorted to pins 2 and 3 (towards the front panel) • U-INT JP2 is shorted to pins 1 and 2 (towards the back panel) The factory setting for JP2 is U-INT. BRG1, BRG2, BRG3, JP4, JP5, JP6 These jumpers are in use when working with the X.21 interface in the DCE mode. To work the X.21 interface in the DCE mode, the jumper must be connected in accordance with the interface in use. For example, if you are using the X.21 interface in DCE mode, JP4 (BRG2) must be connected to Link 2. To work with Link 1, connect JP5 (BRG1). To work with Link 3, connect JP3. When working with the X.21 interface in DTE mode, the jumper must be disconnected. 2-4 Hardware Configuration SPS-3S Installation and Operation Manual Chapter 2 Installation Figure 2-2. SPS-3S Identification of Internal Jumpers Interface Board SPS-3S is available with four types of removable interface boards. Port 1 of the unit is available as DDS for DDS CSU/DSU interface. The interface board types are: SPS-3S • V.24 (RS-232) interface • V.35 interface • RS-530 (V.36) interface • X.21 interface • IR-ETH • ISDN • DDS CSU/DSU interface. Hardware Configuration 2-5 Chapter 2 Installation Warning Installation and Operation Manual In order to avoid the possibility of electrical shock, always disconnect the power cable from wall plug before opening the SPS-3S. Each interface board can be configured as DCE or DTE by changing the main jumper. The main jumper consists of multiple jumpers that must be changed together. Each board is marked DCE DTE. The UI-X21 interface board is shown in Figure 2-3. Figure 2-3. UI-232 Interface Board The interface board determines the physical layer configuration of a SPS-3S link. When the board is set as DTE, the link must be used with a flat cable to connect to a terminal. The link receives its clock from outside and the clock parameter must be configured as external clock. When the board is set as DCE, the link uses the internal clock, and the clock parameter must be configured as internal clock (for more information, see the RAD Packet Switching Guide). Jumper Setting Procedure In order to avoid the possibility of electrical shock, always disconnect the power cable from the wall plug before opening the unit. Warning To access the printed circuit board of SPS-3S, loosen screws on the bottom of the unit and remove the top cover. Refer to Figure 2-2 or Figure 2-3and identify jumper locations and settings. Change settings as required. Replace the SPS-3S cover, gently push it down until it clips into place and fasten screws. 2-6 Hardware Configuration SPS-3S Installation and Operation Manual 2.5 Chapter 2 Installation Installation in 19" Racks SPS-3S can be installed in 19" racks. Unit height corresponds to 1U (1.75"). The width of the unit is slightly less than the available mounting width. An adapter kit provides the hardware necessary for installation of the unit in 19" racks. The paragraph below provides step-by-step instructions for this procedure. Disconnect the units from AC power while performing the following procedures. Warning Installation of the Unit The rack adapter kit for the installation includes two long-arm brackets. The brackets are fastened by means of screws to the two side walls of the case. The installation of SPS-3S is shown in Figure 2-4. To prepare the unit for rack installation, attach the two brackets to the side walls of the unit. Each bracket is fastened by means of two screws (with flat washers), which are inserted into the two front holes on the side wall (nuts are already in place, on the inner side of the wall). After attaching the brackets, the unit is ready for installation in the 19" rack. Fasten the brackets to the side rails of the 19" rack by means of four screws (not included in the kit), two on each side. Figure 2-4. Installation of SPS-3S in 19" Rack SPS-3S Installation in 19" Racks 2-7 Chapter 2 Installation Installation and Operation Manual 2.6 Cable Connections General SPS-3S has three connectors located on the rear panel that serve the synchronous links, and an RJ-45 connector located on the front panel for the asynchronous data channels. Asynchronous Data Channel Connections The SPS-3S channel interfaces are configured as data communication equipment (DCE) interfaces, thereby allowing direct connection, via RS-232 port cables, to data terminal equipment (DTE). When modems are used to extend the range (tailend circuits), cross-over cables are required. Channel interfaces are asynchronous, therefore clock signals are neither supported, or required. The Packet Switching Guide lists pin allocations in SPS-3S data channel connectors, and provides typical wiring diagrams for straight-through and cross-over cables. Synchronous Links Connection Each interface board can be configured as DCE or DTE by changing the main jumper. The main jumper consists of multiple jumpers that must be changed together. Each board is marked DCE DTE. The X.25 link connectors type depends on the SPS-3S interface: • V.24: 25-pin D-type, female connector • X.21: 25-pin D-type, female connector (via adapter cable) • V.35: 25-pin D-type, female connector (via adapter cable) • V.36: 25-pin D-type, female connector (via adapter cable) • RS-530: 25-pin D-type, female connector • IR-ETH: 10BaseT, UTP cable, RJ-45 • ISDN S-interface, UTP cable, RJ-45 • DDS: 8-pin RJ-45, female connector. Appendix A provides the pin allocations. Note The user data cables and the synchronous links cables should be shielded, in order to comply with FCC rules. The SPS-3S and its data interfaces will work well even if the cables are not shielded, but some radio interference may occur. Power Connection AC power should be supplied to the SPS-3S through the 5 feet (1.5m) power cable terminated by a standard 3-prong plug. Connect the cable between the AC mains connector on the SPS-3S rear panel and a standard grounded AC outlet. 2-8 Cable Connections SPS-3S Installation and Operation Manual Warning Chapter 2 Installation BEFORE APPLYING POWER TO THIS UNIT, the protective earth terminals of this instrument must be connected to the protective ground conductor of the (mains) power cord. The mains plug should only be inserted in a socket outlet provided with a protective earth contact. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding). Make sure that only fuses with the required rated current, as marked on the SPS-3S rear panel, are used for replacement. The use of repaired fuses and the short-circuiting of fuse holders must be avoided. Whenever it is likely that the protection offered by fuses has been impaired, the instrument must be made inoperative and be secured against any unintended operation. Any interruption of the protective (grounding) conductor (inside or outside the unit) or disconnecting the protective earth terminal can make this unit dangerous. Intentional interruption is prohibited. SPS-3S Cable Connections 2-9 Chapter 2 Installation 2-10 Cable Connections Installation and Operation Manual SPS-3S Chapter 3 Operation 3.1 General SPS-3S supports a wide range of applications. These include: • Connection of a bridge/router using HDLC encapsulation over Frame Relay • Encapsulating private X.25 over Frame Relay networks • Connecting SDLC/QLLC/LLC environment T-PADs and FEPs over X.25 or Frame Relay Networks • Providing interfaces to DDS Networks • SLIP communication and IP encapsulation over Frame Relay or X.25 protocols. For more detailed configuration information, refer to the RAD Packet Switching Guide and RAD Packet Switching Applications Guide. 3.2 Controls, Indicators and Connectors Front Panel Table 3-1 lists the functions of the SPS-3S front panel indicators and connectors. The numbers under the heading “Item” refer to the identification numbers in Figure 3-1. Figure 3-1. SPS-3S Front Panel SPS-3S Controls, Indicators and Connectors 3-1 Chapter 3 Operation Installation and Operation Manual Table 3-1. SPS-3S Controls, Indicators and Connectors Item Control, Indicator or Connector Function 1 PWR Indicator Lights up when SPS-3S is powered. 2 Main Links Activity Indicators Indicators, one for each main link, light up when the corresponding link is active (receives or transmits frames). 3 Channel Activity Indicator Indicator lights up when the channel is active (receives or transmits data). 4 SYN Indicators Indicators, one for each main link, indicate synchronization status. Condition: Indication: Off SPS-3S is not powered On SPS-3S is powered and synchronized with the corresponding peer. Flashing SPS-3S is powered but (Continuous) not synchronized with the corresponding peer. 3-2 5 ERR Indicator Lights up when a hardware malfunction is detected during the self-test automatically performed upon power-up, or after pressing the RESET push-button. 6 OVF Indicator Lights up when the SPS-3S buffers are full. In a properly designed system, this condition usually indicates that one of the units connected to the unit does not respond to the flow control commands sent by SPS-3S, a condition that could be caused by incorrect configuration of the unit. 7 TEST Indicator Lights up to indicate that SPS-3S is in diagnostics mode (one of the test loops active). In either case, traffic is interrupted. 8 Channel Connector Connection to the SPS-3S channel. Controls, Indicators and Connectors SPS-3S Installation and Operation Manual Chapter 3 Operation Rear Panel Table 3-2 lists the functions of the SPS-3S rear panel controls and connectors. The numbers under the heading “Item” refer to the identification numbers in Figure 3-2. Figure 3-2. SPS-3S Rear Panel Controls and Connectors Table 3-2. SPS-3S Rear Panel Controls and Connectors Item Control or Connector Function 1 Power Connector AC power connector with integral fuse 2 Synchronous Links Connectors Connection to synchronous link 3.3 Operating Instructions General After being prepared for operation as explained above, SPS-3S normally operates unattended. Operator intervention is only required when the unit is set up for the first time or must be adapted to new operational requirements. Note SPS-3S configuration is stored in a non-volatile memory, and is not affected when power is turned off. Power-On Connect the power cable to the unit's rear power connector; the PWR indicator should light up. All the indicators on SPS-3S should flash, according to the default. Check that after a short interval (during which SPS-3S performs self-test), the ERR, OVF and TEST indicators are extinguished. SPS-3S Operating Instructions 3-3 Chapter 3 Operation Installation and Operation Manual Normal Operation During normal operation, the PWR and SYNC indicators should light up continuously and the TEST, OVF and ERR indicators must remain off. Channel activity indicators flash according to the traffic load, and are extinguished when the channel is idle. Power-Off To turn off the unit, disconnect its power cable from the mains. 3.4 What to do in Case of Malfunction Preliminary Checks In case a problem occurs, the following actions will help you return the to normal operation. • Check that the unit is powered (PWR indicator should light up). • Check that cables are properly connected. • Check that the equipment connected to the unit is powered and operates normally. • Check the LED indicators. • Check the configuration of SPS-3S and that of the remote PAD or switch correspond to the requirements of the equipment connected to its channels. Troubleshooting In case the preliminary checks do not correct the problem, press RESET or turn the unit off, and then turn it on again. If the problem repeats, refer to the RAD Packet Switching Guide for additional operations. 3-4 What to do in Case of Malfunction SPS-3S Appendix A Connector Pinouts This appendix provides information needed for the SPS-3S interface connections. The information presented in this appendix includes a description of the Control connector, connector pin functions and where applicable – the recommended wiring for relevant adapter cables. A.1 Interface Connectors X.21 Port Pinouts V.24 Port Pinouts SPS-3S Interface Connectors A-1 Appendix A Connector Pinouts Installation and Operation Manual V.35 Port Pinouts V.36 Port Pinouts A-2 Interface Connectors SPS-3S Installation and Operation Manual Appendix A Connector Pinouts RS-530 Port Pinouts A.2 Control Connector The control connector of SPS-3S is an RJ-45 8-pin female connector with a serial RS-232 DCE interface, intended for connection to an ASCII-based terminal. Connector pin functions are listed in Table A-1. • To connect a supervision terminal having a 9-pin connector to the control connector, use the appropriate adapter cable (CBL-RJ45/D9/F/STR or CBL-RJ45/D9/M/STR, supplied). Figure A-1 shows the wiring diagram of this cable. Table A-1. RJ-45 Control Connector Pin Functions Pin Function 1 GND 2 Not connected 3 Receive Data (RXD) from terminal 4 Not connected 5 Transmit Data (TXD) to terminal 6 Not connected 7 GND 8 Not connected Terminal Control Table The terminal control port cable has an 8-pin RJ-45 connector on one side, and a 9-pin, D-type, female connector on the other side. SPS-3S Control Connector A-3 Appendix A Connector Pinouts Installation and Operation Manual Figure A-1. Wiring RJ-45 to DB-9 Adapter Cable (CBL-RJ45/DB9/F/STR) A-4 Control Connector SPS-3S 24 Raoul Wallenberg St., Tel Aviv 69719, Israel Tel: +972-3-6458181, Fax: +972-3-6483331, +972-3-6498250 E-mail: [email protected], Web site: www.rad.com Customer Response Form RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an e-mail with your comments. Thank you for your assistance! SPS-3S Manual Name: ______________________________________________________________ 159-200-10/06 Publication Number: __________________________________________________________ Please grade the manual according to the following factors: Installation instructions Operating instructions Manual organization Illustrations The manual as a whole Excellent Good Fair Poor Very Poor What did you like about the manual? ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ Error Report Type of Error(s) Incompatibility with product or Problem(s): Difficulty in understanding text Regulatory information (Safety, Compliance, Warnings, etc.) Difficulty in finding needed information Missing information Illogical flow of information Style (spelling, grammar, references, etc.) Appearance Other _________ Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.) and attach the page to your fax, if necessary. _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ Please add any comments or suggestions you may have. _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ You are: Distributor End user VAR Other ________________________ Who is your distributor? _______________________________ Your name and company: ___________________________________________________________ Job title: __________________________________________________________________________ Address: __________________________________________________________________________ Direct telephone number and extension: _______________________________________________ Fax number: ______________________________________________________________________ E-mail: _____________________________________________________________________ www.rad.com INTERNATIONAL HEADQUARTERS: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 Fax: 972-3-6498250, 972-3-6474436, Email: [email protected] NORTH AMERICA HEADQUARTERS: 900 Corporate Drive, Mahwah, N.J. 07430, Tel: (201) 529-1100 Toll Free: 1-800-444-7234, Fax: (201) 529-5777, Email: [email protected] Publication No. 159-200-10/06