* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ME372
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Multidimensional empirical mode decomposition wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Distribution management system wikipedia , lookup
Smart meter wikipedia , lookup
Opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Energy Measurement and Management ME372 Single-phase electronic meter with built-in communication channel Technical description Version 1.0, 09.03.2006 Contents: 1. Meter appearance ................................................ 5 1.1. Meter case ...................................................... 5 1.2. Over-all and fixing dimensions........................ 6 2. Meter configuration ............................................. 6 2.1. Metering system.............................................. 6 2.2. Power supply stage......................................... 6 2.3. Microcontroller ................................................ 6 2.3.1. Load-profile recorder................................ 7 2.3.2. Log-book .................................................. 7 2.3.3. Keeping of billing results .......................... 7 2.4. Real-time clock ............................................... 7 2.4.1. Time-of-use registration ........................... 7 2.4.2. Maximum demand.................................... 7 2.5. LED ................................................................. 7 2.6. LCD................................................................. 8 2.6.1. Data display.............................................. 8 2.6.2. Signal flags............................................... 8 2.7. Push-buttons................................................... 9 2.7.1. LCD testing............................................... 9 2.7.2. Manual data scroll .................................... 9 2.7.3. Load-profile data display ........................ 10 2.7.4. Manual meter billing reset ...................... 10 2.8. Communication channels ..............................10 2.8.1. Optical port..............................................10 2.8.2. RS485 communication interface - option11 2.8.3. Integrated GSM/GPRS communication interface with antenna - option..........................11 2.8.4. Readout via built-in communication interfaces ..........................................................11 2.9. Inputs and outputs.........................................11 2.9.1. Alarm inputs ............................................11 2.9.2. Load control output .................................12 2.10. Detectors of opening meter and terminal block covers..........................................................12 2.11. Built-in circuit-breaker..................................12 3. Data protection...................................................12 4. Meter connection procedure.............................12 4.1. Connection procedure of GSM/GPRS communication interface ...................................13 5. Accessory for meters managing ......................13 6. Meter maintaining ..............................................13 7. Meter connection ...............................................14 8. Technical data ....................................................15 9. Meter type designation......................................16 Energy Measurement and Management ME372 Single-phase electronic meter The ME372 electronic single-phase meter is designed for measurement and registration of active energy in single-phase two-wire networks for direct connection. The metering and technical properties of the meters comply with the IEC 62053-21 and IEC 62052-11 (former IEC 61036) international standards for electronic meters of active energy for classes 1 and 2. The meters are designed and manufactured in compliance with the ISO 9001 standard. The ME372 meters are the third generation of Iskraemeco electronic single-phase meters for a deregulated market of electric power, with the following common functional properties: • Time-of-use measurement of active energy and maximum demand (in up to 4 tariffs) • Load-profile registration (option) • LCD in compliance with the VDEW specification, with two modes of data display • Internal real-time clock • Two pushbuttons: Reset and Scroll • Optical port in compliance with the IEC 62056-21 standard for local meter programming and data downloading • Built-in interface or a modem for remote meter programming and data downloading • M-Bus • Built-in circuit breaker • Prepaid functionality The first generation of Iskraemeco electronic singlephase meters for a deregulated market of electric power, i.e. the ME420 meters had RS232 or RS485 interface for remote two-way communication, and utilized IEC 62056-21, mode C the communication protocol. The second generation of Iskraemeco electronic single-phase meters for a deregulated market of electric power, i.e. the ME351 had an integrated DLC modem for two-way communication via low voltage distributions network - or upon request - RS485 interface instead, for remote two-way communication. It utilized the DLMS communication protocol in compliance with the IEC 62056-51 standard as well as IEC 62056-21, mode C protocol. These meters had the following additional functional properties: • Two S0 pulse inputs (option) • Pulse output • Tariff input (option) The third generation of Iskraemeco electronic singlephase meters for a deregulated market of electric power consists of two meter types: the ME372 meter with built-in GSM/GPRS modem – or upon request RS485 interface instead, for remote two-way communication. Meter utilize the DLMS communication protocol in compliance with the IEC 62056-46 standard as well as IEC 62056-21, mode C protocol. Further to the ME372 meters functionality they also enable: • Detectors of the meter and the terminal box covers opening • • Module for remote disconnection / re-consection of the customer premises (option) M-Bus for reading other meters (heat, gass, watter) ME372 ─ Electronic three-phase meters with built-in communication channel ME372 meter properties: • Meter of active energy and demand Accuracy class 1 or 2 • • • • Modes of energy measurement and registration For one-way energy flow direction, For two-way energy flow direction, For two-way energy flow direction registered in one (absolute) register but Meter quality: Due to high accuracy and long term stability of metering elements no meter re-calibration over its life-time is required High meter reliability High immunity to EMC Additional meter functions: The second metering element can be built into the meter – measurement of current that flows through the neutral conductor (option for BS housing) Measurement and registration of under- and over-voltage Generation of alarms and their transmitting via the DLC modem and low voltage network • Load-profile recorder: Two load profile objects with 16 capture objects each • Communication channels: Infrared optical port in compliance with the IEC 62056-21 for local meter programming and data down-loading Built-in GSM/GPRS modem or RS485 communication interface instead Built in M-Bus communication interface • LCD: In compliance with the VDEW specification • Data display modes: Automatic cyclic data display with display time of 10 sec Manual data display mode (by pressing the Scroll push-button) • Indicators: LCD: - Presence of phase voltage L1 - Phase currents flow direction - Valid tariff at the moment - Meter status and alarms OBIS data identification code: IEC 62056–61 • Auxiliary inputs / outputs: M-Bus communication interface instead An load control relay output used for load management • Automatic configuration of an AMR system: The meters are registered themselves into an AMR system • Detection of opening meter and terminal block covers • Current terminals: Enable fast installation of meters into network Make good contact with current conductors regardless of their design and material Time-of-use registration (up to 4 tariffs): Tariffs change-over by internal real-time clock • 4 LED: - Imp / kWh - Test frequency for testing accuracy of the meter time base (only in the meter testing mode) • Communication protocols: Optical port: IEC 62056 – 21, mode C or DLMS (in compliance with IEC 62056 – 46) GSM/GPRS modem or RS485: DLMS by IEC 62056 – 46 COSEM organization of data: IEC 62056-53 M-Bus: EN 13757-2 and EN 13757-3 Do not damage conductors. • Potential links: Potential links enable simple disconnection of potential and current circuits of the meter The potential links can be mounted in the terminal block compartment or under the meter cover • • Simple and fast meter installation Compact plastic meter case: Made of high quality self-distinguishing UV stabilized material that can be recycled IP54 protection against dust and water penetration (by IEC 60529) ME372 ─ Electronic three-phase meters with built-in communication channel 1. Meter appearance with a hinge. The lid covers the Reset push-button and can be sealed in the closed position. The terminal block contains current terminals, auxiliary terminals and potential links for supplying potential circuits of the meter. ITEM 1 2 3 4 5 6 7 8 9 DESCRIPTION Licquid cristal display (LCD) Meter tehnichal data Legend for data shovn on LDC A meter cover sealing screw A terminal cover A terminal cover sealing screw Impulse LED Scroll (blue) and Reset (orange) keys IR optical interface Two screws for fixing the meter cover (item 4) are sealed with metrological seals. One screws for fixing the terminal block cover (item 6) and the Reset push-button lid (item 8) are sealed with seals of electric utility. 1.1. Meter case A compact meter case consists of a meter base with a terminal block and three fixing elements for mounting the meter, a meter cover and a terminal block cover. The case is made of self-distinguishing UV stabilized polycarbonate which can be recycled. The case ensures double insulation and IP54 (IEC 60529) protection level against dust and water penetration. The top hanger is on the back side of the meter base, under the top edge. On request an extended top hanger can be mounted on the meter base, which ensures the upper fixing hole height of 230 mm above the line connecting the bottom fixing holes (DIN 43758). The meter cover is made of transparent polycarbonate. A nickel-plated iron ring in the right top corner is utilized for attaching an optical probe to the optical port. There is a lid which is fixed to the meter cover ITEM 1 2 3 4 5 6 7 8 9 DESCRIPTION A switch for detection of terminal cover opening Screw to screwing current cables Aditional voltage terminals Current terminals Neutral terminals Load control output M-Bus communicatin interface Second alarm input First alarm input Current terminals (item 4) are made of galvanized iron sheet. They are universal terminals for all shapes and cross sections of connected conductors up to 25 mm2. The terminals ensure the same contact quality with conductors either they are made of copper or aluminum. Only one screw in a current terminal reduces time needed for the meter installation in the field. Due to the indirect pressure on the conductor it is not damaged. Up to 10 auxiliary terminals can be fitted in the meter. They can be utilized for M-Bus, bi-stabile 6 A relay for load control or alarm-inputs. Inputs and outputs are fitted into the meter regarding the customers request at meter ordering. Voltage terminals (item 3) are built into the meter upon request. They are intended for supplying an add-on unit from the meter terminal block. Detectors of opening the terminal block cover (item 1) and the meter cover (it is on the PCB adjacent to the optical port) are built into the meter upon request. The terminal block cover can be long or short. The meter connection diagram is stuck on the inner side of the terminal block cover. 5 ME372 ─ Electronic three-phase meters with built-in communication channel 1.2. Over-all and fixing dimensions 2.1. Metering system The metering systems enable, beside precission measurement of active energy and demand in a wide metering and temperature range, measurement of phase voltages and currents too. One metering element is built in the meters. The current sensor is shunt, while voltage sensor is resistive voltage divider. Signals of currents and voltages are fed to the A/D converters, and then they are digitally multiplied so that instantaneous power is calculated. The instantaneous powers are integrated and summed in a microcontroller, as well as further processed. Over-all and fixing dimensions of a meter fitted with a long terminla block cover 2. Meter configuration Metering element GSM/GPRS MODEM or Rs485 COMMUNICATION INTERFACE The metering elements ensure excellent metering properties: 1. Wide metering range 2. Negligible influence of disturbances and influence quantities 3. High long-term stability so that meter re-calibration is not required over its life-time 4. Long meter life-time and high reliability in use 2.2. Power supply stage The power supply stage consists of a switcher, which enables a meter to operate accuratelly in a wide voltage range. It enables a meter to operate accuratelly even when voltage in the network is only 80% of the rated voltage. 2.3. Microcontroller The microcontroller acquires signals from the metering elements, processes them and calculates values of measured energy. The results are stored in energy registers for particular tariffs. It also calculates demands and register maximum demand in billing periods. The microcontroller also generates pulses for the LED and the output pulses, enables two-way communication via the optical port, the DLC modem and M-Bus and drives the LCD and the control outputs. The microcontroller enables registration of a load-profile and events into a log-book, as well. 6 ME372 ─ Electronic three-phase meters with built-in communication channel 2.3.1. Load-profile recorder 2.4.1. Time-of-use registration Two load profile objects are provided with up to sixteen capture objects each. The following registration periods 15, 30 and 60 minutes or a daily value can be set. The meter enables registration of energy and demand in up to four tariffs. Tariff changeover is defined with hour, minute and second. Minimal resolution between changeovers is one minute. The real-time clock enables complex daily and weekly tariff struc-tures, as well as a couple of seasons in a year: • Up to 4 seasons in a year • Up to 8 daily definitions of the changeover program • Up to 8 changeovers inside individual daily tariff programs • Up to 32 holidays in which a special tariff program is defined including the holidays relating to the lunar calendar Data in a load-profile recorder are accompanied with a time stamp and with the meter status in the last saving period as well as with a check sum. The time stamp indicates the end of a registration period. 2.3.2. Log-book The meters can register up to 128 events and meter status in a log-book which is organized as a FIFO memory. In this way, the last 128 events and meter status are always available. The following events and meter status can be registered: • Meter fatal error • Billing reset of the meter • Time setting of the real-time clock • Voltage failure • Voltage re-establishing in the network • Erased registers of the load-profile recorder • Erased registers of the log-book • Voltage failure • Voltage re-establishing • Opening of the meter and the terminal block covers 2.3.3. Keeping of billing results The meter keeps billing results (energy and demand values registered by tariffs) for last 18 billing periods. A number of billing periods (months) for which billing results are kept is set in the factory and can not be changed subsequently. The billing results are stored in a FIFO memory, so that they are always available for the last n (n = 1, 2, …18) billing periods, regardless if the meter billing reset was performed by means of the Reset push-button, RTC or remotely via communication channel. The metering results of the past billing periods can not be displayed; they can be read out via communication channels, i.e. via optical port and DLC modem. 2.4.2. Maximum demand The real-time clock generates a demand period. Demand is calculated as an average value over the demand period. The following demand periods can be set in the meter: 5, 15, 30 and 60 minutes. At the end of the demand period, calculated demand value is transferred from a register for current demand period into a register for previous demand period and is compared with a value in a register of the maximum demand. If new demand value is larger than the value in the maximum demand register, then it is entered into the maximum demand register, otherwise the old maximum demand value is kept. In this way, a maximum demand is registered at the meter billing reset. 2.5. LED The meter is provided with a LED on the front plate. The LED emits pulses with frequency that is proportional to the measured power and is intended for the meter calibration and testing. The LED is turned-on and glows steadily if load is lower than the meter starting current. 2.4. Real-time clock A real-time clock is controlled with a 32.768 kHz crystal. Its accuracy complies with the IEC 62052-21 standard for time switches. The RTC involves an internal calendar that assures information on year, month, day, day in a week, hour, minute, second and leap year. A super capacitor is used as the RTC back-up power supply. It assures 250 hours of the RTC operation reserve. For a complete charging of the super capacitor the meter should be connected to network voltage for at least 60 minutes. 7 ME372 ─ Electronic three-phase meters with built-in communication channel 2.6. LCD The 7-segment LCD, with additional characters and symbols, complies with the VDEW specifications. Large characters and a wide angle view enable easy data reading. Data are displayed in the right-side bottom corner by means of eight 8 mm high alphanumeric characters. The OBIS code (by IEC 62056-61) is employed for data identification. It is displayed in the left bottom corner by means of five 6 mm high alphanumeric characters. An indicator of energy flow direction is displayed in the left top corner. A physical unit of displayed quantity is shown in the right top corner. The indicator of L1 phase voltage presence is displayed in the middle of the top row. In the LCD bottom row there are eleven signal flags that indicate current valid tariff, meter status and alarms. Meaning of each signal flag is engraved on the meter name plate beneath each of the signal flags in use. 2.6.1. Data display Data defined in Auto scroll sequence and in Manual scroll sequence are displayed on the LCD. Data from Auto scroll sequence are dispalyed in a circle, each is displayed for 10 sec. At Manual scroll sequence the blue push-button should be pressed for displaying the next piece of data. Data in Manual scroll sequence remains displayed until the blue push-button is pressed again or until time for automatic return into the Auto scroll sequence is not elapsed. Data that can be displayed are listed in the table bellow. Which of them will be displayed depends on customer request at meter ordering. CODE DATA DESCRIPTION 0.0.0 C.1.0 0.9.1 0.9.2 1.2.1.8.0 1.3.1.8.0 1.8.0 15.8.0 1.8.1 15.8.1 1.8.2 Meter serial number Meter manufacturer number Time Date Value on counter for the first pulse input Value on counter for the second pulse input Total imported active energy (A+) Total absolute active energy |A| Imported active energy in the first tariff (T1) Absolute active energy in the first tariff |T1| Imported active energy in the 2-nd tariff (T2) 8 CODE DATA DESCRIPTION 15.8.2 1.8.3 15.8.3 1.8.4 15.8.4 2.8.0 2.8.1 2.8.2 2.8.3 2.8.4 1.6.1 1.6.2 1.6.3 1.6.4 2.6.1 2.6.2 2.6.3 2.6.4 F.F* Absolute active energy in the 2-nd tariff |T2| Imported active energy in the third tariff (T3) Absolute active energy in the third tariff |T3| Imported active energy in the fourth tariff (T4) Absolute active energy in the fourth tariff |T4| Total exported active energy (A-) Exported active energy in the first tariff (T1) Exported active energy in the 2-nd tariff (T2) Exported active energy in the third tariff (T3) Exported active energy in the 4-th tariff (T4) A+ import. max. demand in the first tariff (T1) A+ import.max. demand in the 2-nd tariff (T2) A+ import. max. demand in the 3-rd tariff (T3) A+ import. max. demand in the 4-th tariff (T4) A- export. max. demand in the first tariff (T1) A- export.max. demand in the 2-nd tariff (T2) A- export. max. demand in the 3-rd tariff (T3) A- export. max. demand in the 4-th tariff (T4) Meter fatal error* 2.6.2. Signal flags The signal flags in the display bottom row indicate certain meter status and alarms. The following flags are active at the ME372 meters: FLAG STATUS T1 T2 T3 T4 Lit Lit Lit Lit T1, T2, Blinking T3, T4 CB Lit MEANING The first tariff is active The second tariff is active The third tariff is active The fourth tariff is active The meter is in the program mode. Mode is acceble when meteorological seals from the meter cover are remowed. Circuit breaker disconect customer, output is open Signal quality SQ REG Lit Lit Lit DRO Blinking FF Lit SET Lit The meter is registered into the AMR communication network Meter data down-loading is in progress Data package is present in the AMR communication network Meter fatal error (the meter should be dismounted and sent to examination) Meter is in setting mode * If the FF code is displayed, the meter should be dismounted from a place of measurement and sent to an authorized repair shop or to the manufacturer for examination. ME372 ─ Electronic three-phase meters with built-in communication channel 2.7. Push-buttons There are two push-buttons on the meter front side: • RESET push-button – the orange pushbutton that is under the lid with a hinge and can be sealed independently from the meter cover. Its primary function is to perform the meter billing reset. • SCROLL push-button – the blue push-button that is always accessible. Its primary function is to scroll data from the Manual scroll sequence on the LCD. Besides the above described push-buttons, the meters are provided with the third one, which is builtin on the PCB under the meter cover – a Param push-button. When depressed it enables to enter into the meter programming in a laboratory, and at the same time it is used as a hardware-lock against tamper attempt. 2.7.1. LCD testing The LCD should be tested in order to check if all its segments are in order. When the meter is in Auto scroll mode, the blue push-button should be pressed shortly (Tp < 2 sec) to enter into the LCD test mode. The LCD test lasts for 10 seconds so that all LCD segments are displayed. After that time the meter returns back into the Auto scroll mode. 2.7.2. Manual data scroll Depending on the time of depressing the pushbuttons and a combination of depressed pushbuttons they enable: • Selection mode of meter operation mode, • Testing the LCD • Scrolling of metering results and setting meter parameters, • Performing manual billing reset of the meters • Alarms reset Time of depressing the orange push-button does not influence in its function, while at the blue push-button three different lengths of depression times are available: a. Short – time of push-button depression shorter than 2 sec – next data in the manual sequence is displayed. b. Long – time of push-button depression longer than 2 sec and shorter than 5 sec – displayed submenu or function is selected c. Extended – time of push-button depression longer than 5 sec – displayed data get back one level up (e.g. if data from the third level are displayed, then the blue push-button should be pressed three times, and each time it should be kept depressed for more than 5 sec in order to return back to Auto scroll mode). Data from the Manual scroll sequence are displayed in the following manner. The meter should be put into the LCD test mode (see item 2.7.1) and during the LCD testing the blue push-button should be depressed for a short time (Top <2 sec). A Std-data title is displayed on LCD indicating that the meter menu for selecting either Manual data scroll or Loadprofile display function is opened. If Manual data scroll function is to be selected, the blue push-button should be depressed for a long time (2 sec < Tp < 5 sec), after which the first data from the Manual scroll sequence is displayed. For displaying the following data from the Manual scroll sequence, the blue push-button should be depressed for a short time (Tp <2 sec). If the blue push-button is depressed short (Tp <2 sec) when a Std-dAtA title is displayed, the next title P1.0 in the menu (function for displaying data from the load-profile recorder) is displayed. To exit the Manual scroll mode the blue push-button should be depressed for extended time (Tp > 5 sec). 9 ME372 ─ Electronic three-phase meters with built-in communication channel 2.7.3. Load-profile data display When a Std-dAtA title is displayed on the LCD (see item 2.7.2), the blue push-button should be depressed for a short time (Tp <2 sec), so that a P1.0 title of the function for displaying load-profile data is displayed. If Load-profile data display function is to be selected, the blue push-button should be depressed long (2 sec < Tp < 5 sec), after which the last date for which data in the Load-profile recorder exist is displayed. At each short depression (Tp < 2 sec) of the blue push-button date of a previous day is displayed until all dates for which data in the load-profile recorder exist are displayed. When date of a day for which load-profile data are to be read is displayed on the LCD, the blue push-button is to be depressed long (2 sec < Tp < 5 sec), after which the first meter status for that date is displayed. After next short depression (Tp < 2 sec) of the blue push-button a load-profile data for this re-cording period is displayed. By each short depression of the blue pushbutton a load profile data for one previous registration period is displayed. period is completed and after that the billing reset will be executed. As long as the microcontroller waits to execute the meter billing reset, the BR signal flag is displayed. When meter billing reset is executed, data from registers for a current month are transferred into registers for a previous month, the registers for current month are initialized and a reset counter is incremented. In order to prevent temper attempts of the Reset push-button after meter billing reset, the orange push-button is disabled for one demand period. If the Reset push-button is pressed once again in a time period shorter than the demand period, the second meter reset command will not be executed. After pressing the Reset push-button, its lid should be closed and sealed again. Upon request, the function of manual meter billing reset can be disabled by software. 2.8. Communication channels The ME372 meters are equipped with the following communication channels: a. Optic port b. M-Bus (option) c. GSM/GPRS modem or d. RS485 communication interface instead GSM/GPRS modem 1 5 The last date for which load-profile data exist (2004-May-26) 4 Meter status for selected date (code and value – five digit data). Load-profile data of the first channel for the selected date – Total imported active energy A+ (register 1.8.0; 123456 kW) To exit the load-profile data display mode the blue push-button should be depressed for an extended time (Tp > 5 sec) or if load-profile data for a certain date is displayed, the blue push-button should be depressed three times for an extended time (Tp > 5 sec) (load-profile data ⇒ date ⇒ title load-profile function P1.0 ⇒ Auto scroll mode). 2.7.4. Manual meter billing reset In order to perform manual billing reset of the meter, so that the meter is made ready for a new billing period, the seal of the Reset (orange) push-button lid should be broken. The Reset push-button should be pressed when the meter is in the Auto scroll mode. The billing reset will not be executed immediately – the microcontroller will wait until the current demand 10 2 ID 1 2 3 4 5 3 DESCRIPTION Place for external coupling device RS485 communication interface MBus communication interface SIM card bed for GSM/GPRS communication IR optical port 2.8.1. Optical port The optical port complies with the IEC 62056-21 and is used for local meter programming and data downloading. It is located in the right top corner of the meter. The communication protocol complies with IEC 62056-21, mode C or DLMS-HDLC IEC 62056-46. The communication is serial asynchronous with data transmission rate from 300 bit/sec to 19,200 bit/sec. If data transmission rate of the used optical probe is lower than 19,200 bit/sec, the maximum permissible data transmission rate is equal to that value. If higher data transmission rate is set, communication via optical port will not be possible. ME372 ─ Electronic three-phase meters with built-in communication channel M-Bus There is M-Bus module integrated in ME372 meters acording to EN 13757-2 and EN 13757-3 micromaster specification which enables connection of 4 slave devices (water, gass or/and heat meters) and max. length of wireing 50 m. There is auto-install procedure implemented. GSM/GPRS interface: at successful communication, several flags are displayed. The flag above the SQ mark indicates signal strength, the flag above the REG mark – if present - indicates that the meter is ready for telecommunication network, and the flag above the DRO mark indicates that communication is going on. 2.8.2. RS485 communication interface option A built-in communication interface enables setting of meter parameters and a local readout of measuring results. The protocol for data transfer is IEC 62056 – 46. 2.8.3. Integrated GSM/GPRS communication interface with antenna - option It enables data transmission via a communication interface towards the centre for management and billing or a data concentrator. Data transmission rate via network is 9600 baud/s, while actual data transmission rate depends on momentary conditions in network. A GSM antenna is built in the meter. It enables operation in three frequency ranges • 900 MHz • 915 MHz • 1800 MHz Fig. 5 – Display legend 2.9. Inputs and outputs The meters can be provided with up to ten auxiliary terminals. The following inputs and outputs are possible: • Two Alarm inputs (option) • Output for load control by a bi-stabile 6 A relay • M-Bus communication interface 2.9.1. Alarm inputs There can be up to two inputs for detecting auxillary alarm and they are open collector type. If a built-in antenna does not meet the needs of covering the signal, an external antenna can be mounted. Coupling circuit is placed on the meter cover and enables a simple mounting of a coupling module. Common Input Fig. 4 – Coupling circuit 2.8.4. Readout via built-in communication interfaces Built-in communication interfaces enable: • Reading of registers • Reading of load profile • Reading of meter parameters • Changing of meter parameters Communication state is shown on a display, i.e. RS485 and IR interface: during communication, a flag above a DRO mark is blinking 11 ME372 ─ Electronic three-phase meters with built-in communication channel 2.9.2. Load control output The load control output is with a bi-stabile relay. The bi-stabile relay can break 6 A at 250 V, Depending on a customer request the control relay can be controlled by time-schedule set in the meter (for ON/OFF switching of appliances by a time-schedule), by calculating trend of maximum demand (load limiter function), or by remote command (together with a built-in circuit breaker – function of remote disconnecting /re-connecting of customer premises). Load control Common 2.10. Detectors of opening meter and terminal block covers Detectors of opening meter and terminal block covers are built into the meter on request. The detectors are two push-button switches which make a signal when the covers are opened. The event is registered in the log-book together with date and time (a time-stamp) of its occurrence. 2.11. Built-in circuit-breaker Built-in circuit breaker is 100 A circuit-breaker. Additional functionality allows to verify actual connection/dissconnection (anti-temper function). Circuit-breaker can be controlled according to timeschedule, maximum demand or by remote command. 12 3. Data protection Special attention is paid to a system of meter data protection in order to prevent meter tampering. Access to the billing data registers in order to change their values is not possible. Param pushbutton that is under the meter cover, so that two seals should break first. 4. Meter connection procedure 1. The meter should be fixed with three screws at the place of measurement. 2. The meter should be connected according to the meter connection diagram that is attached to the meter terminal block cover. Torque of the screws tightening in the current terminals is 2.5 Nm. 3. The meter operation should be checked: The LED is turned-on (load current is lower than the meter starting current) The LED is blinking with frequency proportional to the engaged electric power (the meter measures and registers energy) The LED is turned-off (the meter is not energized). In this case it should be checked if: a. current conductors are connected to the meter (if not, they should be connected) b. the potential links are in their bottom position (if not, the potential link slides should be pushed to their bottom position) c. If both upper conditions are fulfilled, it means that there is no voltage in the mains. 4. Check the L1 indicator on the LCD. • Check date and time set in the internal RTC and, if needed, set the correct values • Make billing reset of the meter • Seal the meter (terminal block cover and the lid of the orange pushbutton). ME372 ─ Electronic three-phase meters with built-in communication channel 4.1. Connection procedure of GSM/GPRS communication interface 5. Accessory for meters managing Checking of the presence of a SIM card 1. Remove a terminal block cover. 2. Check if a SIM card is inserted as shown on a figure below 3. If a SIM card is not inserted, insert it into the shown place • For maintaining meter programming and data down-loading: MeterView (Iskraemeco software) Optical probe Personal computer: PC, desk-top, lap-top. The accessory is intended for the personel who maintains and programs meters in a repair shop and in the field. • For meter reading and programming in the field: MeterRead (Iskraemeco software) for all types of hand-held computers (Palm-top PC), utilizing the Windows CE operation system, Optical probe. Fig. 8 – SIM card bed Check the GSM/GPRS signal strength on LCD: a. The flag is permanently lit; good covering with a GSM/GPRS signal. b. The flag is blinking; bad covering with the GSM/GPRS signal. It is recommended to find a better location for meter installation. c. The flag is not lit; it is recommended to find a better location for installation. If the flag is not lit even on a new place, an external antenna is required. Note, limits are adjustable For the meters managing the folowing accessories are availble: • For remote meter reading and programming: SEP2W (Iskraemeco software, with modules for remote meter reading, data base management and a module for data presentation and printing) Central station – a server with corresponding software and hardware. 6. Meter maintaining No maintenance is required during the meters lifetime. The implemented metering technique, built-in components and manufacturing procedures ensure high long-term stability of the meters, so that there is no need for their re-calibration during their life-time. 13 ME372 ─ Electronic three-phase meters with built-in communication channel 7. Meter connection The meter connection diagram is stuck on the inner side of the terminal block cover. The meters can be connected in single-phsae two-wire net-works. Communication interface – M-Bus Hardware type Function Communication interface Common Communication interface Mini master Terminal 90 91 Communication interface – RS485 Hardware type Function RS485 – GND G RS485 – A B RS485 – B A RS485 – A B RS485 – B A Terminal 28 27 29 27 29 Inputs Hardware type Low voltage (up to 24V, 27mA) Low voltage (up to 24V, 27mA) Outputs Hardware type High voltage (250V, 6A) 14 Function Common Terminal 20 Alarm input 15 Common 85 Alarm input 80 Function Common Load control Terminal 35 34 ME372 ─ Electronic three-phase meters with built-in communication channel 8. Technical data GENERAL METERING CHARACTERISTICS Accuracy class 2 or 1 ( IEC 62053-21) Base current Ib 5A Max. current Imax 85 A Thermal current 1,2 Imax Starting current <0.005 Ib at cosϕ = 1, for class 2 <0.004 Ib at cosϕ = 1, for class 1 Short-circuit 30 Imax current Reference 1x230 V voltage (other voltages on request) Voltage range 0,8 Un ... 1,15 Un Rated frequency 50 Hz or 60 Hz Meter constant 1.000 imp/kWh at Imax = 85 A (at LED) Operating temperature -25°C ... +60°C range Extended temperature -40°C ... +70°C range Storage -40°C ... +80°C temperature Voltage circuit < 2 W / 10 VA burden Current circuit < 0,16 VA burden (regardless to meter base current ) INTERNAL RTC Accuracy ≤±6 ppm or ≤±3 min / year (at 25°C) RTC operation 150 hours reserve (back-up power source: super cap) Crystal frequency 32 kHz OPTICAL PORT Optical port IEC62056-21 (IEC61107) Protocol IEC62056-21 (IEC61107) Mode E and DLMS IEC62056-46, Data identification OBIS (IEC 62056-61) code 19,200 bit/sec (limited with data Data transmission transmission rate of the used optical rate probe) LOAD-PROFILE RECORDER Number of 2 objects OUTPUTS High voltage output Hardware type; bistable relay Output type; Load control Switching voltage: 250 V Switching current: 6 A INPUTS Low voltage input Hardware type: Passive transistor input Inputs type; Alarm input 1 Switching voltage: 3 – 24 V AC/DC Low voltage input Hardware type: Passive transistor input Inputs type; Alarm input 2 Switching voltage: 3 – 24 V AC/DC BUILT-IN CIRCUIT BREAKER Module type: bi-stabile relay Built-in circuitBreaking voltage: 230 V breaker Breaking current: 100 A EMC Dielectric strength 4 kV, 50 Hz, 1 min Electrostatic 15 kV ( IEC 61000 - 4 - 2 ) discharge High frequency electromagnetic 10 V/m ( IEC 61000 - 4 – 3 ) field Burst 4 kV ( IEC 61000 - 4 - 4 ) Impulse voltage 12kV, 1,2/50 µ s ( IEC 62053-21 and IEC 62052-11) – into the main metering circuitry 6 kV, 1.2/50 µs ( IEC 62053-21 and IEC 62052-11) – into the auxiliary circuits OVER-ALL DIMENSIONS AND MASS Meter with a long terminal block cover Dimensions 132 x 200 x 78 mm (w x h x d) Mass 0.8 kg RS485 communication interface Protocol Data transmission rate IEC62056-46 or IEC62056-21 Marking of registers in compliance with OBIS (IEC62056-61) 115200 bit/sec GSM/GPRS communication interface Protocol GSM Protocol GPRS Data transmission rate IEC62056-46 or IEC62056-21 IEC62056-46, GSM: 9600 bit/sec GPRS: 28000 bit/sec Actual rate depends on network configuration! M-Bus Protocol Baud-rate Wireing length No. slave devices EN 13757-2 and EN 13757-3 2400 bit/s 50 m 4 15 ME372 ─ Electronic three-phase meters with built-in communication channel 9. Meter type designation Electronic meter single-phase meter With built-in remote communication interface M E 372 - Terminal block for Imax=85 A (DIN 43857) Terminal block for Imax=100 A (DIN 43857) Active energy, class 1 Active energy, class 2 One energy-flow direction measurement Two energy-flow direction measurement Measurement of energy absolute value D1 D3 A4 A5 1 2 4 - Pulse input (option) Number of inputs (n = 1, 2) Resistor type pulse input Build in circuit breaker Phase disconection Control output with bi-stabile relay One control output Relay output with make contact V n 2 P 1 B 1 1 M 2 K 0 3 a g Z Internal RTC Back-up power supply source: super capacitor Communication channel Optical port by IEC 62056 – 21 RS485 communication interface Built in GSM/GPRS modem Active M-Bus (master) Load-profile recorder (option) Due to improvements the actually delivered products can differ in some details from the data stated in this technical description. Iskraemeco d.d., Energy Measurement and Management 4000 Kranj, Savska loka 4, Slovenia Phone (+386 4) 206 40 00, Fax: (+386 4) 206 43 76 http://www.iskraemeco.si, E-mail: [email protected] Publisher: Iskraemeco, Marketing Reserved right to modifications without notice. 16 ME372_tehnichal description_20060309.doc