Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Cost Allocation / Cost Center Acquisition Energy Meters for direct measurement Energy Meters for direct measurement For single-phase or three-phase mains - 1x 230 V or 3x 230/400 V - 80 A direct connection - MID approval. Subject to technical changes © FRAKO GmbH Main Catalogue 2015 - EM 307 EM-EC 380 / EM-EC 380 MID* EM-PM 380 ● ● Consumed active energy ● ● Consumed reactive energy ● - Regenerated active energy ● ● Regenerated reactive enery ● - - / ● (MID)* - - - B/2 B/2 Number/consumed active energy 1 (T1 and T2) 1 Number/consumed reactive energy 1 (T1 and T2) - Number/regenerated active energy - 1 Infrared interface for connecting communication modules ● ● Modbus RTU / M-Bus 1) ● ● KNX-EIB (Energy and demand) 1) ● ● Page 309 ff. Page 311 ff. Energy Meters for direct measurement Measurements Calibratable Calibrated Accuracy class (active energy/reactive energy) Impulses Interfaces Catalogue page 1) using a suitable interface adapter 308 Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH Cost Allocation / Cost Center Acquisition Energy Meters for direct measurement EM-EC 380 / EM-EC 380 MID Electronic Energy Meter Three-phase energy meter, four-wire system for measuring electrical active and reactive power in low voltage networks with counter, performance indication and output for active and reactive pulse. Current inputs: direct up to 80 A EM-EC 380 MID: MID calibrated Description ■■ One impulse for consumed active energy and one impulse for consumed reactive energy ■■ Performance measurement as value and bars ■■ Side infrared interface for connecting communication modules Modbus RTU / M-Bus for energy and performance U, I, PF, F, KNX-EIB for energy and power Subject to technical changes © FRAKO GmbH Main Catalogue 2015 - EM 309 Technical Data Versions Power supply Supply voltage Taken from measurement voltage Measurements Consumed active energy/ reactive energy ●/● Regenerated active energy/ reactive energy ●/● Approval EM-EC 380: EM-EC 380 MID: calibrated (MID) Article-No. Type Description 29-20098 EM-EC 380 Three-phase energy meter, four-wire technology 29-20099 EM-EC 380MID Three-phase energy meter, four-wire technology, calibrated Optional Accessories Accuracy class Active energy/reactive energy: B/2 Connection type 2- up to 4-wire Article-No. Type Description 29-20104 EM-CM MODBUS Modbus communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power U, I, PF and F. 29-20105 EM-CM MBUS M-Bus communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power U, I, PF and F. 29-20121 EM-CM SD-Card SD Card data logger with SD Card. The communication between the module and the energy meter is realized via the infrared interface. 29-20106 EM-CM KNX EIB/KNX communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power. Current measurement Transformer x/... - Directly up to 80 A Ratio adjustable - Power consumption 0.8 VA/Phase Current inputs galvanically isolated Voltage measurement Range of voltage 3 x 230/400 V +/- 20 % Power consumption 0.5 VA Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/consumed active energy T1 and T2 1/consumed reactive energy T1 and T2 Valency 500 Imp/kWh at 80 A Duration 30 +/- 2 ms Load 5...230 V AC/90 mA, 5...300 V DC/90 mA LED 1000 Imp/kWh LC-Display (illuminated) ● Detection of faulty connection ● Tariffs 2 Mechanical construction Dimensions 72 x 90 x 70 mm (W x H x D), 4 HP Ingress protection Housing: IP51 Terminal block with clamp lid: IP20 Conductor crosssection Transformer: Direct: 35 mm2 Installation Standard rail 35 mm Weight 0.4 kg Dimensions Operating conditions Operating temperature -10 °C bis +55 °C All dimensions in mm 310 Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH Cost Allocation / Cost Center Acquisition Energy Meters for direct measurement EM-PM 380 Energy Meter Three-phase Energy Meter, four-wire system for carrying out electrical measurements in low voltage networks such as I, U, PF, F as well as all power ratings for each phase. ■■ ■■ ■■ ■■ ■■ ■■ Description Measurement of energy consumption and energy output Pulse output Current inputs are galvanically isolated One pulse output for consumed and a separate one for regenerated energy Measurement of I, U (Ph/Ph), U (Ph/N), PF, F as well as all power values for each phase Side infrared interface for connecting communication modules Modbus RTU / M-Bus for above mentioned values, KNX-EIB for energy and power Subject to technical changes © FRAKO GmbH Main Catalogue 2015 - EM 311 Technical Data Optional Accesories Power supply Supply voltage Taken from measurement voltage Measurements Consumed active energy/ reactive energy ●/- Regenerated active energy/ reactive energy ●/- Approval - Accuracy class Active energy/reactive energy: B/2 Connection type 2- up to 4-wire Article-No. Type Description 29-20104 EM-CM MODBUS Modbus communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power U, I, PF and F. 29-20105 EM-CM MBUS M-Bus communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power U, I, PF and F. 29-20121 EM-CM SD-Card SD Card data logger with SD Card. The communication between the module and the energy meter is realized via the infrared interface. 29-20106 EM-CM KNX EIB/KNX communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power. Current measurement Transformer x/... - Directly up to 80 A Ratio adjustable - Power consumption 0.8 VA/Phase Current inputs galvanically isolated Voltage measurement Range of voltage 3 x 230/400 V +/- 20 % Power consumption 0.5 VA Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/ consumed active energy 1/consumed reactive energy Valency 2000 Imp/kWh at 80 A Duration 30 +/- 2 ms Load 5...230 V AC/90 mA, 5...300 V DC/90 mA LED 1.000 Imp/kWh LC-Display ● Detection of faulty connection ● Tariffs - Dimensions Mechanical construction Dimensions 72 x 90 x 70 mm (W x H x D), 4 HP Ingress protection Housing: IP51 Terminal block with clamp lid: IP20 Conductor crosssection Transformer: Direct: 35 mm2 Installation Standard rail 35 mm Weight 0.4 kg Operating conditions 312 Operating temperature -10 °C up to +55 °C Article-No. 29-20103 All dimensions in mm Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH Cost Allocation / Cost Center Acquisition Energy Meters for measurement via Current Transformers (CT) Energy Meters for measurement via current transformer (CT) For single-phase or three-phase networks - 1x 230 V or 3x 57.7/100 V .... 230/400 V - 1 A and 5 A transformer connection in one device - MID-approval. Subject to technical changes © FRAKO GmbH Main Catalogue 2015 - EM 313 EMC ETAR EM-EC 35 / EM-EC 35 MID* EM-PM 35 ● ● ● Consumed active energy ● ● ● Consumed reactive energy ● ● - Regenerated active energy - ● ● Regenerated reactive energy - ● - Calibratable - - / ● (MID)* - Calibrated - - - 1/2 B/2 B/2 Number/consumed active energy 1 1 (T1 and T2) 1 Number/consumed reactive energy 1 1 (T1 and T2) - Number/regenerated active energy - - 1 Infrared interface for connecting communication modules - ● ● Modbus RTU / M-Bus 1) - ● ● Energy Meters for measurements via CTs Measurements Accuracy class (active energy/reactive energy) Impulses Interfaces KNX-EIB (energy and power) Catalogue page 1) - ● ● Page 315 ff. Page 317 ff. Page 319 ff. 1) using a suitable interface adapter 314 Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH Cost Allocation / Cost Center Acquisition Energy Meters for measurement via Current Transformers (CT) EMC ETAR Energy Meter Three-phase energy meter in three/four-wire technique for detecting electrical active and reactive energy in low and medium voltage networks with counter and output for active and reactive pulse. Description ■■ Current inputs are galvanically isolated Subject to technical changes © FRAKO GmbH Main Catalogue 2015 - EM 315 Technical Data Optional Accessories Power supply Supply voltage Taken from measurement voltage Article-No. Type Description 29-20062 EMC ETAR front frame Front frame (7 HP) for the installation of the energy meter (EMC ETAR) in a cabinet door Measurements Consumed active energy/ reactive energy ●/● Regenerated active energy/ reactive energy -/- Approval - Accuracy class Active energy/reactive energy: 1/2 Connection type 3-/4-wire Dimensions Current measurement Transformer x/... 1 A and 5 A Directly up to - CT-ratio adjustable x/1 or x/5; 1... 999 999 Power consumption 0.8 VA/Phase Current inputs ● galvanically isolated All dimensions in mm Voltage measurement Range of voltage 3 x 57.7 / 100 V... 3 x 230/400 V +/- 15 % Power consumption < 1 VA, 1 W Frequency 50/60 Hz Pulse output SO (potential-free contact) Number/use 1 for consumed active energy 1 for consumed reactive energy Valency 0.1 Wh/Imp...100 kWh/Imp, 0.1 varh/Imp...100 kvarh/Imp Duration 50...1500 ms Load 5...230 V AC/100 mA, 5...325 V DC/100 mA LED 1 Imp/Wh / 1 Imp/varh LC-Display (illuminated) ● Detection of faulty connection ● Tariffs - Mechanical construction 316 Dimensions 122.5 x 100 x 58.5 mm (W x H x D); 7 HP Ingress protection Housing: IP51 Terminal block with clamp lid: IP20 Conductor crosssection Transformer: 6 mm2 Direct: - Installation Standard rail 35 mm Weight 0.4 kg Article-No. 29-20107 Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH Cost Allocation / Cost Center Acquisition Energy Meter for measurement via Current Transformers (CT) EM-EC 35 / EM-EC 35 MID Energy Meter Three-phase energy meter, four-wire technology for measuring electrical active and reactive power in low voltage networks with counter, performance indication and output for active and reactive pulse. Current inputs (x/5A) galvanically isolated. EM-EC 35 MID: MID calibrated Description ■■ One impulse for consumed active energy and one impulse for consumed reactive energy ■■ Performance measurement as value and bars ■■ Side infrared interface for connecting communication modules -- Modbus RTU / M-Bus for energy and performance U, I, PF, F, -- KNX-EIB for energy and power Subject to technical changes © FRAKO GmbH Main Catalogue 2015 - EM 317 Technical Data Versions Power supply Supply voltage Taken from measurement voltage Measurements Consumed active energy/ reactive energy ●/● Regenerated active energy/ reactive energy ●/● Approval EM-EC 35: EM-EC 35 MID: calibrated (MID) Article-No. Type Description 29-20100 EM-EC 35 Three-phase energy meter, four-wire technology 29-20101 EM-EC 35 MID Three-phase energy meter, four-wire technology, calibrated Optional Accessories Accuracy class Active energy/reactive energy: B/2 Connection type 4-wire Article-No. Type Description 29-20104 EM-CM MODBUS Modbus communication module. The communication between the module and the energy meter is realized via the infrared interface. Valuese: energy and power U, I, PF and F. 29-20105 EM-CM MBUS M-Bus communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power U, I, PF and F. 29-20121 EM-CM SD-Card SD Card data logger with SD Card. The communication between the module and the energy meter is realized via the infrared interface. 29-20106 EM-CM KNX EIB/KNX communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power. Current measurement Transformer x/... 5A Directly up to - Ratio adjustable x/5; 5...10 000; Smallest input step: 5 Power consumption 0.7 VA/Phase Current inputs ● galvanically isolated Voltage measurement Range of voltage 3 x 230/400 V +/- 20 % Power consumption 0.5 VA Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/consumed active energy T1 and T2 1/consumed reactive energy T1 and T2 Valency I primary 5...300 A = 100 Imp/kWh or Imp/kvarh, 301...3000 A = 10 Imp/kWh or Imp/kvarh, 3001...10 000 A = 1 Imp/kWh or Imp/kvarh Duration 30 +/- 2 ms Load 5...230 V AC/90 mA, 5...300 V DC/90 mA LED 10.000 Imp/kWh LC-Display (illuminated) ● Detection of faulty connection ● Tariffs 2 Dimensions Mechanical construction Dimensions 72 x 90 x 70 mm (W x H x D), 4HP Ingress protection Housing: IP51 Terminal block with clamp lid: IP20 Conductor crosssection Transformer: 6 mm2 Direct: - Installation Standard rail 35 mm Weight 0.4 kg Operating conditions Operating temperature 318 -10 °C up to +55 °C Dimensional drawing EM-EC 35 / EM-EC 35 MID All dimensions in mm Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH Cost Allocation / Cost Center Acquisition Energy Meter for measurement via Current Transformers (CT) EM-PM 35 Energy Meter Three-phase, four-wire measuring technique for electrical measurements in low voltage networks: I, U, PF, F and all power ratings for each phase. ■■ ■■ ■■ ■■ ■■ ■■ Description Measurement of consumed and regenerated energy Pulse output Current inputs are galvanically isolated One impulse for consumed and one for regenerated energy Measurement of I, U (Ph/Ph), U (Ph/N), PF, F sas well as all power ratings for each phase Side infrared interface for connecting communication modules Modbus RTU / M-Bus for above mentioned values, KNX-EIB for energy and power Subject to technical changes © FRAKO GmbH Main Catalogue 2015 - EM 319 Technical Data Optional Accessories Power supply Supply voltage Taken from measurement voltage Measurements Consumed active energy/ reactive energy ●/- Regenerated active energy/ rective energy ●/- Approval - Accuracy class Active energy/reactive energy: B/2 Connection type 4-wire Article-No. Type Description 29-20104 EM-CM MODBUS Modbus communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power U, I, PF and F. 29-20105 EM-CM MBUS M-Bus communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power U, I, PF and F. 29-20121 EM-CM SD-Card SD Card data logger with SD Card. The communication between the module and the energy meter is realized via the infrared interface. 29-20106 EM-CM KNX EIB/KNX communication module. The communication between the module and the energy meter is realized via the infrared interface. Values: energy and power. Current measurements Transformer x/... 5A Directly up to - Ratio adjustable x/5; 5...10 000; Smallest input step: 5 Power consumption 0.7 VA/Phase Current inputs ● galvanically isolated Voltage measurement Range of voltage 3 x 230/400 V +/- 20 % Power consumption 0.5 VA Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/for consumed active energy 1/for consumed reactive energy Valency dependent on the current transformer Duration 30 +/- 2 ms Load 5...230 V AC/90 mA, 5...300 V DC/90 mA LED 10 000 Imp/kWh LC-Display ● Detection of faulty connection ● Tariffs - Dimensions Mechanical construction Dimensions 72 x 90 x 70 mm (W x H x D), 4HP Ingress protection Housing: IP51 Terminal block with clamp lid: IP20 Conductor crosssection Transformer: 6 mm2 Direct: - Installation Standard rail 35 mm Weight 0.4 kg Operating conditions 320 Operating temperature -10 °C bis +55 °C Article-No. 29-20102 All dimensions in mm Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH Cost Allocation / Cost Center Acquisition Cost Centre and Alarm Unit EMF 1102 Cost Centre and Alarm Unit The EMF 1102 is a compact and cost-effective system for the aquisition and storage of meter readings, switching status and alarm signals. Description It consists of a data acquisition and memory unit plus modular software components for easy user configuration and for the evaluation and management of the data. Remote alarms can be transmitted by SMS via modem. The EMF 1102 can be used as a stand-alone system for the acquisition of utilities and operating data in a factory or other premises, or can be installed as an integral part of a FRAKO Energy Management System. Data acquisition for all types of utility such as electricity, water, gas, compressed air, or meter pulse inputs via an S0 interface. Subject to technical changes © FRAKO GmbH ■■ Calculation of power, energy and flow rates ■■ Monitoring of power, energy or flow rate with high and low alarm settings ■■ Determination of running time and downtime for each channel (running time meter) ■■ Operating cycle counter ■■ Monitoring of running times and downtimes with alarm settings (e.g. to detect instrument failure) ■■ Monitoring of key operating conditions ■■ Remote alarms by SMS in an event of system faults or if monitored variables exceed critical limits ■■ Storage of all utility data with memory for several days ■■ Connection: -- via RS-232 adapter with modem or COM server or direct to PC or -- via FRAKO Starkstrombus® to the EMP communications process or the EMZ bus central unit ■■ Option of visualising and evaluating the meter data via the FRAKO Energy Management System software module (EMVIS 3000) ■■ Option of displaying, configuring and evaluating the recorded data via the PC by means of the EMF-SW cost centre and alarm software EMF-SW (optional) Main Catalogue 2015 - EM 321 Technical Data Optional Accessories Power supply Mains voltage 230 V AC +/- 10 % Frequency 45 to 65 Hz Article-No. Type Description 20-10310 EM-RS 232 RS-232 Adapter for direct access via PC to the data of EMA 1101 (SW-Version 1.11*), EMR 1100 (SW-Version 1.95*) and EMF 1102 (SW-Version 1.0*) 20-10309 EM-RS 232 for modem operation RS-232 Adapter for direct access via PC to the data of EMA 1101 (SW-Version 1.11*), EMR 1100 (SW-Version 1.95*) or EMF 1102 (SW-Version 1.0*) via modem 20-10319 Registration license EMF 1102 License allows EMVIS 3000 access to a Cost Centre and Alarm System EMF 1102, if this is logged on using a virtual data connector. 20-10313 EMF-SW Display, analysis and configuration software for Cost Centre and Alarm System EMF 1102. Access via: EMIS® 1500, EMP 1100, EMT 1101 and RS-232 adapter. Note: included in scope of delivery of FRAKONET (for CD delivery) Power consumption Approx. 10 VA Inputs General 12 Pulse Inputs S0-Interfaces (DIN 43864) for connection of potential-free contacts, common 'E-'-Potential switching time: >= 25 ms Voltage with open contact: 12 V DC +/- 10 % Short circuit current: 12 mA +/- 10 % Pulse frequency: max. 20 Hz Internal shifter shafts: 'Off' at approx. 3 mA, 'On' at approx. 7.5 mA Outputs 1 Voltage output 12 V DC, max. 50 mA Interfaces (Betriebsart wahlweise) 1 FRAKO Starkstrombus® For connection to FRAKO Energy Management System, according to EN 50170 (P-Net), standardised fieldbus, RS-485 Transfer rate: 76.8 kbit/s RS-232 Interface Optional via RS-232 Adapter direct connection to PC Tranfer rate: 19.200 Baud Display elements 14 LEDs Connections Screw terminals Conductor cross-section: max. 2.5 mm² Mechanical construction Dimensions 140 x 90 x 59 mm (W x H x D), DIN module cases 8 TE Ingress protection Housing/Terminals IP40/20 Version Protection class II according to VDE 0411 / DIN EN 61010-1 Housing flame retardant UL94-V0 Installation on standard rail 35 mm according to DIN EN 50022 Mounting position Optional Weight Approx. 0.6 kg * or higher Dimensions Operating conditions Ambient temperature 0 °C up to +60 °C Article-No. 20-40005 All dimensions in mm 322 Main Catalogue 2015 - EM Subject to technical changes © FRAKO GmbH