Cost Allocation / Cost Center Acquisition
Energy Meters for direct measurement
Energy Meters for direct measurement
For single-phase or three-phase mains - 1x 230 V or 3x 230/400 V - 80 A direct connection - MID approval.
Subject to technical changes © FRAKO GmbH
Main Catalogue 2015 - EM
307
EM-EC 380 /
EM-EC 380 MID*
EM-PM 380
●
●
Consumed active energy
●
●
Consumed reactive energy
●
-
Regenerated active energy
●
●
Regenerated reactive enery
●
-
- / ● (MID)*
-
-
-
B/2
B/2
Number/consumed active energy
1 (T1 and T2)
1
Number/consumed reactive energy
1 (T1 and T2)
-
Number/regenerated active energy
-
1
Infrared interface for connecting
communication modules
●
●
Modbus RTU / M-Bus 1)
●
●
KNX-EIB (Energy and demand) 1)
●
●
Page 309 ff.
Page 311 ff.
Energy Meters for direct
measurement
Measurements
Calibratable
Calibrated
Accuracy class
(active energy/reactive energy)
Impulses
Interfaces
Catalogue page
1) using a suitable interface adapter
308
Main Catalogue 2015 - EM
Subject to technical changes © FRAKO GmbH
Cost Allocation / Cost Center Acquisition
Energy Meters for direct measurement
EM-EC 380 / EM-EC 380 MID
Electronic Energy Meter
Three-phase energy meter, four-wire system for measuring electrical active and reactive power in low voltage networks with counter, performance indication and output for active and reactive pulse.
Current inputs: direct up to 80 A
EM-EC 380 MID: MID calibrated
Description
■■ One impulse for consumed active energy and one impulse for consumed reactive energy
■■ Performance measurement as value and bars
■■ Side infrared interface for connecting communication modules Modbus RTU / M-Bus for energy and performance U, I, PF, F,
KNX-EIB for energy and power
Subject to technical changes © FRAKO GmbH
Main Catalogue 2015 - EM
309
Technical Data
Versions
Power supply
Supply voltage
Taken from measurement voltage
Measurements
Consumed
active energy/
reactive energy
●/●
Regenerated
active energy/
reactive energy
●/●
Approval
EM-EC 380: EM-EC 380 MID: calibrated (MID)
Article-No.
Type
Description
29-20098
EM-EC 380
Three-phase energy
meter, four-wire
technology
29-20099
EM-EC 380MID
Three-phase energy
meter, four-wire
technology, calibrated
Optional Accessories
Accuracy class
Active energy/reactive energy: B/2
Connection type
2- up to 4-wire
Article-No.
Type
Description
29-20104
EM-CM MODBUS
Modbus
communication
module. The
communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power U, I, PF and F.
29-20105
EM-CM MBUS
M-Bus communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power U, I, PF and F.
29-20121
EM-CM SD-Card
SD Card data logger
with SD Card. The
communication
between the module
and the energy meter
is realized via the
infrared interface.
29-20106
EM-CM KNX
EIB/KNX
communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power.
Current measurement
Transformer x/...
-
Directly up to
80 A
Ratio adjustable
-
Power consumption 0.8 VA/Phase
Current inputs
galvanically isolated
Voltage measurement
Range of voltage
3 x 230/400 V +/- 20 %
Power consumption 0.5 VA
Frequency
50 Hz
Pulse output SO (potential-free contact)
Number/use
1/consumed active energy T1 and T2
1/consumed reactive energy T1 and T2
Valency
500 Imp/kWh at 80 A
Duration
30 +/- 2 ms
Load
5...230 V AC/90 mA,
5...300 V DC/90 mA
LED
1000 Imp/kWh
LC-Display
(illuminated)
●
Detection of faulty
connection
●
Tariffs
2
Mechanical construction
Dimensions
72 x 90 x 70 mm (W x H x D), 4 HP
Ingress protection
Housing: IP51
Terminal block with clamp lid: IP20
Conductor crosssection
Transformer: Direct: 35 mm2
Installation
Standard rail 35 mm
Weight
0.4 kg
Dimensions
Operating conditions
Operating
temperature
-10 °C bis +55 °C
All dimensions in mm
310
Main Catalogue 2015 - EM
Subject to technical changes © FRAKO GmbH
Cost Allocation / Cost Center Acquisition
Energy Meters for direct measurement
EM-PM 380
Energy Meter
Three-phase Energy Meter, four-wire system for carrying out electrical measurements in low voltage networks such as I, U, PF, F as well
as all power ratings for each phase.
■■
■■
■■
■■
■■
■■
Description
Measurement of energy consumption and energy output
Pulse output
Current inputs are galvanically isolated
One pulse output for consumed and a separate one for regenerated energy
Measurement of I, U (Ph/Ph), U (Ph/N), PF, F as well as all power values for each phase
Side infrared interface for connecting communication modules Modbus RTU / M-Bus for above mentioned values, KNX-EIB for energy
and power
Subject to technical changes © FRAKO GmbH
Main Catalogue 2015 - EM
311
Technical Data
Optional Accesories
Power supply
Supply voltage
Taken from measurement voltage
Measurements
Consumed
active energy/
reactive energy
●/-
Regenerated
active energy/
reactive energy
●/-
Approval
-
Accuracy class
Active energy/reactive energy: B/2
Connection type
2- up to 4-wire
Article-No.
Type
Description
29-20104
EM-CM MODBUS
Modbus
communication
module. The
communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power U, I, PF and F.
29-20105
EM-CM MBUS
M-Bus communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power U, I, PF and F.
29-20121
EM-CM SD-Card
SD Card data logger
with SD Card.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
29-20106
EM-CM KNX
EIB/KNX
communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power.
Current measurement
Transformer x/...
-
Directly up to
80 A
Ratio adjustable
-
Power consumption 0.8 VA/Phase
Current inputs
galvanically isolated
Voltage measurement
Range of voltage
3 x 230/400 V +/- 20 %
Power consumption 0.5 VA
Frequency
50 Hz
Pulse output SO (potential-free contact)
Number/use
1/ consumed active energy
1/consumed reactive energy
Valency
2000 Imp/kWh at 80 A
Duration
30 +/- 2 ms
Load
5...230 V AC/90 mA,
5...300 V DC/90 mA
LED
1.000 Imp/kWh
LC-Display
●
Detection of faulty
connection
●
Tariffs
-
Dimensions
Mechanical construction
Dimensions
72 x 90 x 70 mm (W x H x D), 4 HP
Ingress protection
Housing: IP51
Terminal block with clamp lid: IP20
Conductor crosssection
Transformer: Direct: 35 mm2
Installation
Standard rail 35 mm
Weight
0.4 kg
Operating conditions
312
Operating
temperature
-10 °C up to +55 °C
Article-No.
29-20103
All dimensions in mm
Main Catalogue 2015 - EM
Subject to technical changes © FRAKO GmbH
Cost Allocation / Cost Center Acquisition
Energy Meters for measurement via Current Transformers (CT)
Energy Meters for measurement via current transformer (CT)
For single-phase or three-phase networks - 1x 230 V or 3x 57.7/100 V .... 230/400 V - 1 A and 5 A transformer connection in one device
- MID-approval.
Subject to technical changes © FRAKO GmbH
Main Catalogue 2015 - EM
313
EMC ETAR
EM-EC 35 /
EM-EC 35 MID*
EM-PM 35
●
●
●
Consumed active energy
●
●
●
Consumed reactive energy
●
●
-
Regenerated active energy
-
●
●
Regenerated reactive energy
-
●
-
Calibratable
-
- / ● (MID)*
-
Calibrated
-
-
-
1/2
B/2
B/2
Number/consumed active energy
1
1 (T1 and T2)
1
Number/consumed reactive energy
1
1 (T1 and T2)
-
Number/regenerated active energy
-
-
1
Infrared interface for connecting
communication modules
-
●
●
Modbus RTU / M-Bus 1)
-
●
●
Energy Meters for measurements via CTs
Measurements
Accuracy class
(active energy/reactive energy)
Impulses
Interfaces
KNX-EIB (energy and power)
Catalogue page
1)
-
●
●
Page 315 ff.
Page 317 ff.
Page 319 ff.
1) using a suitable interface adapter
314
Main Catalogue 2015 - EM
Subject to technical changes © FRAKO GmbH
Cost Allocation / Cost Center Acquisition
Energy Meters for measurement via Current Transformers (CT)
EMC ETAR
Energy Meter
Three-phase energy meter in three/four-wire technique for detecting electrical active and reactive energy in low and medium voltage
networks with counter and output for active and reactive pulse.
Description
■■ Current inputs are galvanically isolated
Subject to technical changes © FRAKO GmbH
Main Catalogue 2015 - EM
315
Technical Data
Optional Accessories
Power supply
Supply voltage
Taken from measurement voltage
Article-No.
Type
Description
29-20062
EMC ETAR
front frame
Front frame (7 HP) for
the installation of the
energy meter (EMC
ETAR) in a cabinet
door
Measurements
Consumed
active energy/
reactive energy
●/●
Regenerated
active energy/
reactive energy
-/-
Approval
-
Accuracy class
Active energy/reactive energy: 1/2
Connection type
3-/4-wire
Dimensions
Current measurement
Transformer x/...
1 A and 5 A
Directly up to
-
CT-ratio adjustable
x/1 or x/5;
1... 999 999
Power consumption 0.8 VA/Phase
Current inputs
●
galvanically isolated
All dimensions in mm
Voltage measurement
Range of voltage
3 x 57.7 / 100 V... 3 x 230/400 V +/- 15 %
Power consumption < 1 VA, 1 W
Frequency
50/60 Hz
Pulse output SO (potential-free contact)
Number/use
1 for consumed active energy
1 for consumed reactive energy
Valency
0.1 Wh/Imp...100 kWh/Imp,
0.1 varh/Imp...100 kvarh/Imp
Duration
50...1500 ms
Load
5...230 V AC/100 mA,
5...325 V DC/100 mA
LED
1 Imp/Wh / 1 Imp/varh
LC-Display
(illuminated)
●
Detection of faulty
connection
●
Tariffs
-
Mechanical construction
316
Dimensions
122.5 x 100 x 58.5 mm (W x H x D); 7 HP
Ingress protection
Housing: IP51
Terminal block with clamp lid: IP20
Conductor crosssection
Transformer: 6 mm2
Direct: -
Installation
Standard rail 35 mm
Weight
0.4 kg
Article-No.
29-20107
Main Catalogue 2015 - EM
Subject to technical changes © FRAKO GmbH
Cost Allocation / Cost Center Acquisition
Energy Meter for measurement via Current Transformers (CT)
EM-EC 35 / EM-EC 35 MID
Energy Meter
Three-phase energy meter, four-wire technology for measuring electrical active and reactive power in low voltage networks with counter,
performance indication and output for active and reactive pulse.
Current inputs (x/5A) galvanically isolated.
EM-EC 35 MID: MID calibrated
Description
■■ One impulse for consumed active energy and one impulse for consumed reactive energy
■■ Performance measurement as value and bars
■■ Side infrared interface for connecting communication modules
-- Modbus RTU / M-Bus for energy and performance U, I, PF, F,
-- KNX-EIB for energy and power
Subject to technical changes © FRAKO GmbH
Main Catalogue 2015 - EM
317
Technical Data
Versions
Power supply
Supply voltage
Taken from measurement voltage
Measurements
Consumed
active energy/
reactive energy
●/●
Regenerated
active energy/
reactive energy
●/●
Approval
EM-EC 35: EM-EC 35 MID: calibrated (MID)
Article-No.
Type
Description
29-20100
EM-EC 35
Three-phase energy
meter, four-wire
technology
29-20101
EM-EC 35 MID
Three-phase energy
meter, four-wire
technology, calibrated
Optional Accessories
Accuracy class
Active energy/reactive energy: B/2
Connection type
4-wire
Article-No.
Type
Description
29-20104
EM-CM MODBUS
Modbus
communication
module. The
communication
between the module
and the energy meter
is realized via the
infrared interface.
Valuese: energy and
power U, I, PF and F.
29-20105
EM-CM MBUS
M-Bus communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power U, I, PF and F.
29-20121
EM-CM SD-Card
SD Card data logger
with SD Card. The
communication
between the module
and the energy meter
is realized via the
infrared interface.
29-20106
EM-CM KNX
EIB/KNX
communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power.
Current measurement
Transformer x/...
5A
Directly up to
-
Ratio adjustable
x/5;
5...10 000;
Smallest input step: 5
Power consumption 0.7 VA/Phase
Current inputs
●
galvanically isolated
Voltage measurement
Range of voltage
3 x 230/400 V +/- 20 %
Power consumption 0.5 VA
Frequency
50 Hz
Pulse output SO (potential-free contact)
Number/use
1/consumed active energy T1 and T2
1/consumed reactive energy T1 and T2
Valency
I primary
5...300 A = 100 Imp/kWh or
Imp/kvarh,
301...3000 A = 10 Imp/kWh or
Imp/kvarh,
3001...10 000 A = 1 Imp/kWh or
Imp/kvarh
Duration
30 +/- 2 ms
Load
5...230 V AC/90 mA,
5...300 V DC/90 mA
LED
10.000 Imp/kWh
LC-Display
(illuminated)
●
Detection of faulty
connection
●
Tariffs
2
Dimensions
Mechanical construction
Dimensions
72 x 90 x 70 mm (W x H x D), 4HP
Ingress protection
Housing: IP51
Terminal block with clamp lid: IP20
Conductor crosssection
Transformer: 6 mm2
Direct: -
Installation
Standard rail 35 mm
Weight
0.4 kg
Operating conditions
Operating
temperature
318
-10 °C up to +55 °C
Dimensional drawing EM-EC 35 / EM-EC 35 MID
All dimensions in mm
Main Catalogue 2015 - EM
Subject to technical changes © FRAKO GmbH
Cost Allocation / Cost Center Acquisition
Energy Meter for measurement via Current Transformers (CT)
EM-PM 35
Energy Meter
Three-phase, four-wire measuring technique for electrical measurements in low voltage networks: I, U, PF, F and all power ratings for
each phase.
■■
■■
■■
■■
■■
■■
Description
Measurement of consumed and regenerated energy
Pulse output
Current inputs are galvanically isolated
One impulse for consumed and one for regenerated energy
Measurement of I, U (Ph/Ph), U (Ph/N), PF, F sas well as all power ratings for each phase
Side infrared interface for connecting communication modules Modbus RTU / M-Bus for above mentioned values, KNX-EIB for energy
and power
Subject to technical changes © FRAKO GmbH
Main Catalogue 2015 - EM
319
Technical Data
Optional Accessories
Power supply
Supply voltage
Taken from measurement voltage
Measurements
Consumed
active energy/
reactive energy
●/-
Regenerated
active energy/
rective energy
●/-
Approval
-
Accuracy class
Active energy/reactive energy: B/2
Connection type
4-wire
Article-No.
Type
Description
29-20104
EM-CM MODBUS
Modbus
communication
module. The
communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power U, I, PF and F.
29-20105
EM-CM MBUS
M-Bus communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power U, I, PF and F.
29-20121
EM-CM SD-Card
SD Card data logger
with SD Card.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
29-20106
EM-CM KNX
EIB/KNX
communication
module.
The communication
between the module
and the energy meter
is realized via the
infrared interface.
Values: energy and
power.
Current measurements
Transformer x/...
5A
Directly up to
-
Ratio adjustable
x/5;
5...10 000;
Smallest input step: 5
Power consumption 0.7 VA/Phase
Current inputs
●
galvanically isolated
Voltage measurement
Range of voltage
3 x 230/400 V +/- 20 %
Power consumption 0.5 VA
Frequency
50 Hz
Pulse output SO (potential-free contact)
Number/use
1/for consumed active energy
1/for consumed reactive energy
Valency
dependent on the current transformer
Duration
30 +/- 2 ms
Load
5...230 V AC/90 mA,
5...300 V DC/90 mA
LED
10 000 Imp/kWh
LC-Display
●
Detection of faulty
connection
●
Tariffs
-
Dimensions
Mechanical construction
Dimensions
72 x 90 x 70 mm (W x H x D), 4HP
Ingress protection
Housing: IP51
Terminal block with clamp lid: IP20
Conductor crosssection
Transformer: 6 mm2
Direct: -
Installation
Standard rail 35 mm
Weight
0.4 kg
Operating conditions
320
Operating
temperature
-10 °C bis +55 °C
Article-No.
29-20102
All dimensions in mm
Main Catalogue 2015 - EM
Subject to technical changes © FRAKO GmbH
Cost Allocation / Cost Center Acquisition
Cost Centre and Alarm Unit
EMF 1102
Cost Centre and Alarm Unit
The EMF 1102 is a compact and cost-effective system for the aquisition and storage of meter readings, switching status and alarm signals.
Description
It consists of a data acquisition and memory unit plus modular
software components for easy user configuration and for the
evaluation and management of the data. Remote alarms can
be transmitted by SMS via modem.
The EMF 1102 can be used as a stand-alone system for the
acquisition of utilities and operating data in a factory or other
premises, or can be installed as an integral part of a FRAKO
Energy Management System.
Data acquisition for all types of utility such as electricity, water,
gas, compressed air, or meter pulse inputs via an S0 interface.
Subject to technical changes © FRAKO GmbH
■■ Calculation of power, energy and flow rates
■■ Monitoring of power, energy or flow rate with high and low
alarm settings
■■ Determination of running time and downtime for each
channel (running time meter)
■■ Operating cycle counter
■■ Monitoring of running times and downtimes with alarm
settings (e.g. to detect instrument failure)
■■ Monitoring of key operating conditions
■■ Remote alarms by SMS in an event of system faults or if
monitored variables exceed critical limits
■■ Storage of all utility data with memory for several days
■■ Connection:
-- via RS-232 adapter with modem or COM server or
direct to PC or
-- via FRAKO Starkstrombus® to the EMP communications
process or the EMZ bus central unit
■■ Option of visualising and evaluating the meter data via the
FRAKO Energy Management System software module
(EMVIS 3000)
■■ Option of displaying, configuring and evaluating the recorded
data via the PC by means of the EMF-SW cost centre and
alarm software EMF-SW (optional)
Main Catalogue 2015 - EM
321
Technical Data
Optional Accessories
Power supply
Mains voltage
230 V AC +/- 10 %
Frequency
45 to 65 Hz
Article-No.
Type
Description
20-10310
EM-RS 232
RS-232 Adapter for
direct access via PC to
the data of EMA 1101
(SW-Version 1.11*),
EMR 1100 (SW-Version
1.95*) and EMF 1102
(SW-Version 1.0*)
20-10309
EM-RS 232 for
modem operation
RS-232 Adapter for
direct access via PC to
the data of EMA 1101
(SW-Version 1.11*),
EMR 1100 (SW-Version
1.95*) or EMF 1102
(SW-Version 1.0*) via
modem
20-10319
Registration
license
EMF 1102
License allows
EMVIS 3000 access
to a Cost Centre and
Alarm System EMF
1102, if this is logged
on using a virtual data
connector.
20-10313
EMF-SW
Display, analysis and
configuration software
for Cost Centre
and Alarm System
EMF 1102. Access via:
EMIS® 1500, EMP 1100,
EMT 1101 and
RS-232 adapter.
Note: included in scope
of delivery of FRAKONET (for CD delivery)
Power consumption Approx. 10 VA
Inputs
General
12 Pulse Inputs
S0-Interfaces (DIN 43864) for
connection of potential-free contacts,
common 'E-'-Potential
switching time: >= 25 ms
Voltage with open contact:
12 V DC +/- 10 %
Short circuit current: 12 mA +/- 10 %
Pulse frequency: max. 20 Hz
Internal shifter shafts: 'Off' at approx.
3 mA, 'On' at approx. 7.5 mA
Outputs
1 Voltage output
12 V DC, max. 50 mA
Interfaces (Betriebsart wahlweise)
1 FRAKO
Starkstrombus®
For connection to FRAKO Energy
Management System, according
to EN 50170 (P-Net), standardised
fieldbus, RS-485
Transfer rate: 76.8 kbit/s
RS-232 Interface
Optional via RS-232 Adapter direct
connection to PC
Tranfer rate: 19.200 Baud
Display elements
14 LEDs
Connections
Screw terminals
Conductor cross-section: max. 2.5 mm²
Mechanical construction
Dimensions
140 x 90 x 59 mm (W x H x D),
DIN module cases 8 TE
Ingress protection
Housing/Terminals IP40/20
Version
Protection class II according to
VDE 0411 / DIN EN 61010-1
Housing
flame retardant UL94-V0
Installation
on standard rail 35 mm according to
DIN EN 50022
Mounting position
Optional
Weight
Approx. 0.6 kg
* or higher
Dimensions
Operating conditions
Ambient
temperature
0 °C up to +60 °C
Article-No.
20-40005
All dimensions in mm
322