Switch Machines and
Associated Equipment
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-23A, M-23B, M-3 and Low-Profile M-3
Electric Switch Machines
ASTS USA’s style “M” Electric Switch Machines are
rugged, reliable, units designed for any installation
where electric power is available. The M-23A and M-23B
units have dual control features, including a hand-throw
lever to permit operation by on-site trainmen or
maintainers, as well as by remote controlled power.
The standard and Low-Profile M-3 Switch Machines are
recommended for applications where there is seldom a
need to manually operate the switch. These three
machines are available with a variety of operating
speeds, gear ratios and motor voltages. Numerous
circuit controller configurations are also available, both
mechanical and electronic.
Table of Contents
General Description ........................................................... 1
M-23A and M-23B Machines with MCC* ............................ 3
M-23A and M-23B Machines with ECC* and MCU* ........... 7
M-23A and M-23B Machines with IPD* .............................. 9
M-3 Switch Machine with MCC* ....................................... 10
M-3 Machines with ECC and EBNC*................................ 13
M-3 Machines with IPD* ................................................... 14
Low-Profile M-3 Machines................................................ 15
* MCC = Mechanical Circuit Controller
ECC = Electronic Circuit Controller
MCU = Motor Control Unit
IPD = Inpendent Point Detection
EBNC = Electronic Biased Neutral Controller
General Description (cont’d)
General Description
Key Options
Style “M” Electric Switch Machines are available with a
numerous features and options to suit customer needs.
These include various operating voltages, gear ratios, throw
times and control wiring schemes as shown in the ordering
tabulations. Basic differences include the following:
Basic Design
Style “M” Electric Switch Machines consist of a motor, a
gear train, a cam arrangement (for operating the switch and
locking) and a circuit controller. All of these machines use
the same basic casting, and are interchangeable with
respect to mounting and connections in a switch layout.
However, the M-23A and M-23B machines require a
somewhat higher clearance than the standard M-3 or Low
Profile M-3. Both models of the M-3 Switch Machine can be
operated by hand by inserting a temporary crank.
For installations where extra vertical clearance is needed,
the Low Profile M-3 Electric Switch Machine is
recommended. This machine is similar to the standard M-3
in design and operation, but is 5/8-inch (1.58 cm) lower in
vertical dimension. This small but important height reduction
makes the Low Profile M-3 ideal for third-rail transit
applications where additional clearance is needed for the
vehicle pick-up shoe. The point detector bar can be
•
M-23A and M-23B with:
‐
Mechanical circuit controller.
‐
Electronic Circuit Controller (ECC) and Motor Control
Unit (MCU)
‐
With independent point detection
‐
Without independent point detection
To order, call 1-800-652-7276
e-mail: [email protected]
•
•
M-3 with:
‐
Mechanical circuit controller for general installations.
‐
ECC and Electronic Biased Neutral Controller
(EBNC)
‐
With independent point detection
‐
Without independent point detection
Low-Profile M-3 with:
‐
Mechanical circuit controller.
‐ Without independent point detection
Refer to the ordering tabulations to determine which of the
above options are available in which combinations, or are
stand-alone options.
www.ansaldo-sts.com
RSE-6A3, p. 1
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
RSE-6A3
Rev. 3-09
General Description (cont’d)
vertically lifted from the machine, allowing easy handling in
tight confines. Left and right-hand versions of this machines
are available, each with a single operating voltage, gear
ratio and wire control scheme.
The M-23A uses a different hand-throw pinion than the M23B, which affects hand-throw locking. Power operation is
the same with both machines. In the M-23A, the hand throw
lever gives the same mechanism stroke and full lock rod
protection as the power operated mode. In the M-23B,
however, the lever does not provide lock-rod protection
(slide bar and lock box do not move full stroke).
All “M” style machines are wired at the factory, with internal
wiring connected to a main terminal board in the motor
compartment. A typical wiring diagram or working drawing is
enclosed with each shipped machine to show how external
connections should be made to the main terminal board for
a particular application.
Motor and Gear Train
ASTS USA “M” Electric Switch Machines use a fully
enclosed, permanent magnet motor. This type of motor
provides lower inductance, better EMI immunity and higher
efficiency than previous field wound motors, and
incorporates simpler 3-wire control. (Permanent magnet
motors are also available for retrofitting older models of
these switch machines; see RSE-6A4.)
The gear train in the “M” style Switch Machines is comprised
of a pinion on the end of the motor shaft, one or two
reduction gears, clutch gear, friction clutch, worm shaft and
worm gear. Three different gear ratios are used to provide
three operating speeds: 189:1, 360:1 and 528:1. The Low
Profile M-3 incorporates the same basic gear train concept
as the other style “M” machines, and is provided with a
single gear ratio of 189:1. In all style “M” machines, a
friction clutch protects the mechanism from the shock
incurred at the end of a stroke, or when an obstruction is
present. For complete motor and gear train specifications,
refer to the ordering tabulations.
Mechanical Circuit Controller
The mechanical Circuit Controller used in the style “M”
switch machines has four pairs of contacts. Two motor
control contacts are wired internally. The remaining are
indication contacts for external switch position
determination. To allow standardized wiring, provision is
made to always have certain contacts set as normal,
regardless of which end of the operating stroke is
designated as normal.
Machines equipped with an mechanical circuit controller
include a point detector with latch device. A latchout kit is
available for the point detector mechanism (see RSE-6A4).
Components in this kit enable the circuit controller indication
contacts to be held open (until reset) when the point detector
bar is displaced while the machine is in locked-up condition
(i.e. switch points obstruction).
RSE-6A3, p. 2
ECC+EBNC or ECC+MCU
ASTS USA offers models of its standard M-3, M-23A and M23B switch machines outfitted with an Electronic Circuit
Controller (ECC), in conjunction with an Electronic Biased
Neutral Controller (EBNC) or Motor Control Unit (MCU). A
true linear detection device with no moving mechanical parts
to maintain, the ECC eliminates circuit-controller sensitivity
degradation due to component wear. The ECC utilizes
inductive proximity sensors to continuously monitor switchmachine conditions. It vitally monitors the position of the
switch points and the internal locking mechanism, delivering
switch-machine indications to the wayside. For more
information on this device, refer to RSE-6F3.
ASTS USA can also add the ECC unit into existing
machines returned to the factory for refurbishment; refer to
the RSE catalog introduction for more information on this
service, or contact your ASTS USA Account Executive.
The EBNC is used in the M-3 machines with ECC to enable
direct control of the switch machine using a bipolar output of
a vital logic controller such as the MicroLok® II or the
MicroLok® Object Controller. In an EBNC-equipped
machine, the motor power is fed from a fixed polarity source
(direction determined by the EBNC). In the M-23A and M23B machines with an MCU, motor power is fed from a
bipolar source (direction determined by the wayside control
equipment). The M-3’s EBNC includes a motor overload
protection function. Overload protection for the M-23A/B’s
MCU is provided by the wayside control equipment. Existing
installations using 3- or 5-wire control are converted to 2wire control when installing an M-3 ECC/EBNC or M-23A/B
ECC/MCU machine.
Independent Point Detection (IDP)
Selected models of the M-3, M-23A and M-23B switch
machines (with mechanical circuit controller) are equipped to
provide independent point detection. With this feature, the
point detection mechanism senses the position of the near
and far switch machine points independently to ensure that
both are in the proper relative positions to each other and
the rails. Thus, any mounting problems or unwanted slack
in the connecting rod between the points are detected. (In
other switch machines, only the nearest switch point
movement is monitored).
M-3 Machines for Replacement of Alstom Machines with 2Wire Control
Four versions of the M-3 Switch Machine with mechanical
circuit controller can be used to replace selected Alstom with
2-wire control. Refer to ordering tabulation on page 12 for
specific part numbers. Contact your ASTS USA Account
Executive or request Service Manual SM-6263 for additional
information.
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information
Ordering Information (cont’d)
•
•
•
•
•
Specifications
Weight:
Dimen. (Overall):
Motor Type:
Motor Voltages:
Motor RPM:
Operating Times*:
Clutch Settings:
Control Ckt. Wiring:
860 lbs. (390 kg)
63.5” L x 33” W x 14” H (161.3 cm
L x 83.8 cm W x 35.6 cm H)
Fully enclosed perm. magnet type
20 Vdc or 110 Vdc (see tabs.)
500 RPM for 528:1 geared mach.
650 RPM for 360:1 geared mach.
1450 RPM for 189:1 geared mach.
4.5, 15.0, or 26.0 sec. (see tabs.)
(*Per AREMA standards. Times will
vary depending upon actual operating
conditions.)
14A for 189:1 geared machines
23A for 360:1 geared machines
12A for 528:1 geared machines
3-wire or 5-wire (see ordering tabs.)
Ordering Information
•
To order M-23A or M-23B switch machines with
mechanical circuit controllers:
‐
Refer to “Configuration Guide” on page 4. Guide
gives all available design and operating options,
each denotes with a letter.
‐
Go to ordering tabs. and select desired options.
‐
Also select machine according to desired motor
voltage, operating speed and gear ratio.
•
Refer to RSE-6A4 for the following support equipment:
‐ Permanent magnet retrofit motor kits for old style M23A and M-23B machines.
‐ Latchout kit.
‐ Latch stand.
‐ Point detector bars
‐ Lock rods and lock connecting rods
Refer to RSE-6F3 to order retrofit Electronic Circuit
Controller (ECC) for style “M” machines with mechanical
circuit controllers.
Refer to RSE-6F4 to order retrofit Electronic Biased
Neutral Controller (EBNC) for M-23A and M-23B switch
machines.
Refer to RSE-6J1 for tools (switch layout and shop
maintenance) used to maintain style “M” machines.
If ordering M-23A or M-23B machines for a new switch
layout, please supply all required specifications, and
mounting dimensions according to approved track plans
(contact your ASTS USA Account Executive for any
assistance needed).
Request ASTS USA Service Manual SM-6263 for M-23A
and M-23B switch machine replacement parts.
Configuration Guide for M-23A and M-23B Switch Machines
with Mechanical Circuit Controller
A
15W, 230V Heater in Circuit Controller
Compartment
B
15W, 230V Heater for Motor
C
15W, 115V Heater in Circuit Controller
Compartment
D
15W, 115V Heater for Motor
E
15W, 115/230V Heater in Circuit Controller
Compartment
F
15W, 115/230V Heater for Motor
G
15W, 24V Heater in Circuit Controller
Compartment
H
15W, 24V Heater for Motor
J
Lock Rod Openings Closed
K
Provided without Main Terminal Board
L
Uses Harness N320067 (Flag Type Terminals)
M
Uses Harness N320069 (Flag Type Terminals)
N
Uses Circuit Controller without Point. Detector
Latch
O
Clutch Set at 14 Amperes
P
Clutch Set at 10 Amperes
Q
Assembled without Latch for Retaining
Machine in the Off-Power Position when Hand
Crank Cover is Open
(continued on next page.)
RSE-6A3, p. 3
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
RSE-6A3
Rev. 3-09
M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information
Configuration Guide for M-23A and M-23B Switch Machines
with Mechanical Circuit Controller
R
(Not applicable to M-23A and M-23B
machines.)
R (M23A)
Ventilators Furnished in the Circuit Controller
Compartment
R (M23B)
With (1) Can Of Lubricant.
S
(Not applicable to M-23A and M-23B
machines.)
S (M23A)
Telephone Jack in Circuit Controller
Compartment
T
15w, 115v Heater for Motor.
U
(Not applicable to M-23A and M-23B
machines.)
Order No.
N451160-0501
N451160-0502
N451160-0503
N451160-0504
N451160-0505
N451160-0506
N451160-0507
N451160-0508
N451160-0509
N451160-0510
N451160-0511
N451160-0512
N451160-0513
N451160-0514
N451160-0515
N451160-0516
N451160-0517
N451160-0518
N451160-0519
N451160-0520
N451160-0521
N451160-0522
N451160-0523
N451160-0524
N451160-0525
N451160-0526
N451160-0527
N451160-0528
N451160-0529
N451160-0530
N451160-0531
N451160-0532
N451160-0533
N451160-0534
N451160-0535
N451160-0536
U (M23A)
V
V (M23A)
W
W (M23A)
X
X (M23A)
Y (M23A)
M-23A Switch Machines with Mechanical Circuit Controller
Motor
Layout
Options
(Vdc)
Left-Hand
-20
Right-Hand
-20
Right-Hand
-20
Right-Hand
K, O, U
20
Left-Hand
K, O, U
20
Left-Hand
-20
Right-Hand
-20
Left-Hand
-20
Left-Hand
C, D
20
Right-Hand
C, D
110
Left-Hand
C, D
110
Right-Hand
N
20
Left-Hand
N
20
Right-Hand
U
110
Right-Hand
A, B
20
Left-Hand
A, B
20
Left-Hand
-20
Right-Hand
-20
Left-Hand
R
110
Right-Hand
R
110
Right-Hand
C, D, R
20
Left-Hand
C, D, R
20
Right-Hand
C, D, S, T
110
Left-Hand
C, D, S, T
110
Right-Hand
G, H, S
20
Left-Hand
G, H, S
20
Right-Hand
C, D, V
110
Left-Hand
C, D, V
110
Right-Hand
C, D, S, T
110
Left-Hand
C, D, S, T
110
Right-Hand
G, H, S
20
Left-Hand
G, H, S
20
Right-Hand
N
20
Left-Hand
N
20
Right-Hand
O, R
110
Left-Hand
O, R
110
Includes 1 Can of Lubricant
(Not applicable to M-23A and M-23B
machines.)
Heater On/Off Switch in Motor Compartment
(Not applicable to M-23A and M-23B
machines.)
Short Circuiting Strip (Shunt Bar) Installed
(Not applicable to M-23A and M-23B
machines.)
Wiring Harness Is Suitable for 3 or 5 Wire
Control
Circuit Controller without Self-Restoring
Latchout Block
Gear
Ratio
360:1
360:1
528:1
528:1
528:1
528:1
360:1
360:1
360:1
189:1
189:1
528:1
528:1
189:1
528:1
528:1
528:1
528:1
189:1
189:1
528:1
528:1
189:1
189:1
360:1
360:1
189:1
189:1
189:1
189:1
360:1
360:1
528:1
528:1
189:1
189:1
(Tabulation continued on following page.)
RSE-6A3, p. 4
Speed
(Sec.)
15.0
15.0
26.0
26.0
26.0
26.0
15.0
15.0
15.0
4.5
4.5
26.0
26.0
4.5
26.0
26.0
26.0
26.0
4.5
4.5
26.0
26.0
4.5
4.5
15.0
15.0
4.5
4.5
4.5
4.5
15.0
15.0
26.0
26.0
4.5
4.5
Control
Circuit Wiring
5-Wire
5-Wire
5-Wire
3-Wire
3-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
3-Wire
3-Wire
5-Wire
5-Wire
5-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
5-Wire
5-Wire
3-Wire
3-Wire
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information
(Tabulation continued from previous page.)
Order No.
N451160-0537
N451160-0538
N451160-0539
N451160-0540
N451160-0541
N451160-0542
N451160-0543
N451160-0544
N451160-0545
N451160-1201
N451160-1202
N451160-1203
N451160-1204
N451160-1205
N451160-1206
N451160-1207
N451160-1208
N451160-1209
N451160-1210
N451160-1211
N451160-1212
N451160-1213
N451160-1214
N451160-1215
N451160-1216
N451160-1217
N451160-1218
N451160-1219
N451160-1220
N451160-1221
N451160-1222
N451160-1223
N451160-1224
N41600101
N41600102
N41600103
N41600104
M-23A Switch Machines with Mechanical Circuit Controller
Motor
Layout
Options
(Vdc)
Right-Hand
N, W
20
Left-Hand
N, W
20
Left-Hand
G, H
110
Right-Hand
G, H
110
Right-Hand
G, H
110
Left-Hand
G, H
110
Left-Hand
U
110
Left-Hand
N, W
110
Right-Hand
N, W
110
Right-Hand
C, D, J
110
Left-Hand
C, D, J
110
Left-Hand
-110
Right-Hand
C, D
110
Left-Hand
C, D
110
Right-Hand
C, D
20
Left-Hand
C, D
20
Left-Hand
-110
Left-Hand
N, W
20
Right-Hand
N, W
20
Left-Hand
C, D, V
110
Right-Hand
C, D, V
110
Right-Hand
E, Q, W
20
Left-Hand
E, Q, W
20
Right-Hand
C, D
110
Left-Hand
C, D
110
Right-Hand
W, X, Y
20
Left-Hand
W, X, Y
20
Right-Hand
C, D, X
110
Left-Hand
C, D, X
110
Left-Hand
C, D
110
Right-Hand
C, D
110
Left-Hand
-20
Right-Hand
-20
Right-Hand
S, T, W, X
20
Left-Hand
S, T, W, X
20
Left-Hand
K, N
20
Right-Hand
K, N
20
Gear
Ratio
528:1
528:1
189:1
189:1
189:1
189:1
189:1
189:1
189:1
189:1
189:1
189:1
189:1
189:1
528:1
528:1
189:1
528:1
528:1
189:1
189:1
528:1
528:1
360:1
360:1
528:1
528:1
189:1
189:1
189:1
189:1
528:1
528:1
528:1
528:1
528:1
528:1
Speed
(Sec.)
26.0
26.0
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
26.0
26.0
4.5
26.0
26.0
4.5
4.5
26.0
26.0
8.0
8.0
26.0
26.0
4.5
4.5
4.5
4.5
26.0
26.0
26.0
26.0
26.0
26.0
Control
Circuit Wiring
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
5-Wire
5-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
RSE-6A3, p. 5
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
RSE-6A3
Rev. 3-09
M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information
Order No.
N451160-0601
N451160-0602
N451160-0603
N451160-0604
N451160-0605
N451160-0606
N451160-0607
N451160-0608
N451160-0609
N451160-0610
N451160-0611
N451160-0612
N451160-0613
N451160-0614
N451160-0615
N451160-0616
N451160-0617
N451160-0618
N451160-0619
N451160-0620
N451160-0621
N451160-0622
N451160-0623
N451160-0624
N451160-0625
N451160-0626
N451160-0627
N451160-0628
N451160-0629
N451160-0630
N451160-0631
N451160-0632
N451160-0633
N451160-0634
N451160-0635
N451160-0636
N451160-0637
N451160-0638
N451160-0639
N451160-0640
N451160-0641
N451160-0642
N451160-0643
N451160-0644
N451160-0645
N451160-0646
N451160-0647
N451160-0648
N451160-0649
N451160-0650
N451160-0651
N451160-0652
N451160-0653
N451160-0654
N41600201
N41600202
N41600203
N41600204
RSE-6A3, p. 6
M-23B Switch Machines with Mechanical Circuit Controller
Motor
Layout
Options
(Vdc)
Right-Hand
E, F
20
Left-Hand
E, F
20
Left-Hand
-20
Right-Hand
-20
Right-Hand
-20
Left-Hand
-20
Left-Hand
C, D
20
Right-Hand
C, D
20
Left-Hand
-110
Right-Hand
-110
Right-Hand
C, D
110
Left-Hand
C, D
110
Right-Hand
C, M
110
Left-Hand
G, H
20
Right-Hand
G, H
20
Left-Hand
C, M
110
Left-Hand
C, D
110
Left-Hand
C, D
20
Left-Hand
G, H
110
Right-Hand
G, H
110
Right-Hand
G, H
20
Left-Hand
G, H
20
Right-Hand
N
20
Left-Hand
N
20
Left-Hand
-20
Right-Hand
-20
Right-Hand
C, D
110
Left-Hand
C, D
110
Left-Hand
G, H
20
Right-Hand
G, H
20
Left-Hand
G, H
110
Right-Hand
G, H
110
Right-Hand
C, D
20
Left-Hand
C, D
20
Left-Hand
C, D
110
Right-Hand
C, D
110
Left-Hand
E, F
110
Right-Hand
E, F
110
Right-Hand
C, D
20
Left-Hand
C, D
20
Left-Hand
E, F
20
Right-Hand
E, F
20
Left-Hand
E, F
20
Right-Hand
E, F
20
Left-Hand
E, F
20
Right-Hand
E, F
20
Left-Hand
K, O, R
20
Right-Hand
K, O, R
20
Left-Hand
C, D, K, N, O, R
110
Right-Hand
C, D, K, N, O, R
110
Left-Hand
G, H
20
Right-Hand
G, H
20
Left-Hand
C, D
110
Right-Hand
C, D
110
Right-Hand
R, S, T, W
20
Left-Hand
R, S, T, W
20
Right-Hand
R, S, T, W
20
Left-Hand
R, S, T, W
20
Gear
Ratio
360:1
360:1
528:1
528:1
360:1
360:1
528:1
528:1
189:1
189:1
189:1
189:1
189:1
528:1
528:1
189:1
189:1
360:1
189:1
189:1
360:1
360:1
528:1
528:1
528:1
528:1
189:1
189:1
528:1
528:1
189:1
189:1
528:1
528:1
189:1
189:1
189:1
189:1
360:1
360:1
528:1
528:1
528:1
528:1
528:1
528:1
528:1
528:1
189:1
189:1
360:1
360:1
360:1
360:1
528:1
528:1
360:1
360:1
Speed
(Sec.)
15.0
15.0
26.0
26.0
15.0
15.0
26.0
26.0
4.5
4.5
4.5
4.5
4.5
26.0
26.0
4.5
4.5
15.0
4.5
4.5
15.0
15.0
26.0
26.0
26.0
26.0
4.5
4.5
26.0
26.0
4.5
4.5
26.0
26.0
4.5
4.5
4.5
4.5
15.0
15.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
4.5
4.5
15.0
15.0
8.0
8.0
26.0
26.0
15.0
15.0
Control
Circuit Wiring
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
3-Wire
3-Wire
5-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
5-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
5-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
5-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-23A and M-23B Machines with ECC and MCU: Specifications and Ordering Information
Specifications
Weight:
Dimen. (Overall):
Motor Type:
Motor Voltages:
Motor RPM:
Operating Times*:
Clutch Settings:
Control Ckt. Wiring:
Ordering Information (cont’d)
860 lbs. (390 kg)
63.5” L x 33” W x 14” H (161.3 cm
L x 83.8 cm W x 35.6 cm H)
Fully enclosed perm. magnet type
20 Vdc or 110 Vdc (see tabs.)
500 RPM for 528:1 geared mach.
650 RPM for 360:1 geared mach.
1450 RPM for 189:1 geared mach.
4.5, 8.0, 15.0, or 26/34 sec. (see
tabs)
(*Per AREMA standards. Times will
vary depending upon actual operating
conditions.)
14A for 189:1 geared machines
10A or 23A for 360:1 geared
machines
12A for 528:1 geared machines
2-wire
Ordering Information
•
To order M-23A or M-23B switch machines with ECC
and MCU:
‐
Refer to “Configuration Guide” at right. Guide gives
all available design and operating options, each
denotes with a letter.
‐
Go to ordering tabulations and select machine with
desired options.
‐
•
•
•
Also select machine according to desired motor
voltage, operating speed and gear ratio.
Refer to RSE-6J1 for tools (switch layout and shop
maintenance) used to maintain style “M” machines.
If ordering M-23A or M-23B machines for a new switch
layout, please supply all required specifications, and
mounting dimensions according to approved track plans
(contact your ASTS USA Account Executive for any
assistance needed).
Request ASTS USA Service Manual SM-9662 for switch
machine replacement parts.
Configuration Guide
A
15-Watt, 115V Motor Heater
B
Lock Rod Openings Closed
C
(Reference not used in this catalog edition.)
D
Equipped with Local/Remote Feature
E
30-Watt, 115/230V Motor Heater Wired for 115V
F
Painted per PP-7905 Aluminum
G
(Reference not used in this catalog edition.)
H
Surge Suppressor PCB
I
(Reference not used in this catalog edition.)
J
(Reference not used in this catalog edition.)
K
Motor Compartment Heater ON/OFF switch
L
(Not applicable to M-23A and M-23B machines.)
RSE-6A3, p. 7
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
RSE-6A3
Rev. 3-09
M-23A and M-23B Machines with ECC and MCU: Specifications and Ordering Information
Order No.
N42650101
N42650102
N42650103
N42650104
N42650105
N42650106
N42650107
N42650108
N42650109
N42650111
N42650112
N42650113
N42650114
N42650117
N42650118
N42650119
N42650120
N42650121
N42650122
N42650127
N42650128
N42650129
N42650130
N42650131
N42650132
Order No.
N42650201
N42650202
N42650207
N42650208
N42650209
N42650210
N42650219
N42650220
N42650221
N42650222
RSE-6A3, p. 8
M-23A Switch Machines with ECC and MCU
Motor
Gear
Control
Layout
Options
(Vdc)
Ratio
Circuit Wiring (3)
Left-Hand
E, H, F
110
189:1
2-Wire MCU
Right-Hand
E, H, F
110
189:1
2-Wire MCU
Left-Hand
E, H, F
110
360:1
2-Wire MCU
Right-Hand
E, H, F
110
360:1
2-Wire MCU
Left-Hand
B, H
110
189:1
2-Wire MCU
Right-Hand
B, H
110
189:1
2-Wire MCU
Left-Hand
E, F
20
528:1
2-Wire MCU
Right-Hand
E, F
20
528:1
2-Wire MCU
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Left-Hand
A, D, H, K
110
189:1
2-Wire MCU
Right-Hand
A, D, H, K
110
189:1
2-Wire MCU
Left-Hand
D
20
528:1
2-Wire MCU
Right-Hand
D
20
528:1
2-Wire MCU
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Right-Hand
A, D, H
110
189:1
2-Wire MCU
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Right-Hand
A, D, H
110
189:1
2-Wire MCU
Left-Hand
A, D, F
20
528:1
2-Wire MCU
Right-Hand
A, D, F
20
528:1
2-Wire MCU
Left-Hand
B, D, F
20
528:1
2-Wire MCU
Right-Hand
B, D, F
20
528:1
2-Wire MCU
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Right-Hand
A, D, H
110
189:1
2-Wire MCU
Left-Hand
E, F
20
360:1
2-Wire MCU
Right-Hand
E, F
20
360:1
2-Wire MCU
Note (1): Configured for near point detection.
Note (2): Configured for far point detection.
Note (3): Wayside provides bipolar 2-wire motor feed to select Normal or Reverse motion.
When one wire is "+", other wire is "-". ECC/MCU passes wayside polarity to motor
terminals to obtain Normal or Reverse motion.
M-23B Switch Machines with ECC and MCU
Motor
Gear
Control
Layout
Options
(Vdc)
Ratio
Circuit Wiring (4)
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Right-Hand
A, D, H
110
189:1
2-Wire MCU
Left-Hand
E, F
20
528:1
2-Wire MCU
Right-Hand
E, F
20
528:1
2-Wire MCU
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Right-Hand
A, D, H
110
189:1
2-Wire MCU
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Right-Hand
A, D, H
110
189:1
2-Wire MCU
Left-Hand
A, D, H
110
189:1
2-Wire MCU
Right-Hand
A, D, H
110
189:1
2-Wire MCU
Note (1): Configured for near point detection.
Note (2): Without auxiliary point detection proximity sensors (in all other machines).
Note (3): Configured for far point detection.
Note (4): Wayside provides bipolar 2-wire motor feed to select Normal or Reverse motion.
When one wire is "+", other wire is "-". ECC/MCU passes wayside polarity to motor
terminals to obtain Normal or Reverse motion.
Notes
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(2)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Notes
(1)
(1)
(1)
(1)
(1)
(1)
(1) (2)
(1) (2)
(2) (3)
(2) (3)
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-23A and M-23B Machines with Independent Point Detection: Specifications and Ordering Information
Ordering Information
•
•
•
•
Specifications
Weight:
Dimen. (Overall):
Motor Type:
Motor Voltages:
Motor RPM:
Operating Times*:
Clutch Settings:
Control Ckt. Wiring:
860 lbs. (390 kg)
63.5” L x 33” W x 14” H (161.3 cm L x
83.8 cm W x 35.6 cm H)
Fully enclosed perm. magnet type
20 Vdc or 110 Vdc (see tabs.)
500 RPM for 528:1 geared mach.
650 RPM for 360:1 geared mach.
1450 RPM for 189:1 geared mach.
5.0 sec.
(*Per AREMA standards. Times will vary
depending upon actual operating conditions.)
14A for 189:1 geared machines
23A for 360:1 geared machines
12A for 528:1 geared machines
3-wire
•
•
To order M-23A or M-23B switch machines with
independent point detection:
‐
Refer to “Configuration Guide” below. Guide
gives all available design and operating
options, each denotes with a letter.
‐
Go to ordering tabulations and select machine
with desired options.
‐
Also select machine according to desired
motor voltage, operating speed and gear ratio.
Refer to RSE-6F3 to order retrofit Electronic
Circuit Controller (ECC) for style “M” machines
with mechanical circuit controllers.
Refer to RSE-6F4 to order retrofit Electronic
Biased Neutral Controller (EBNC) for M-23A and
M-23B switch machines.
Refer to RSE-6J1 for tools (switch layout and
shop maintenance) used to maintain style “M”
machines.
If ordering M-23A or M-23B machines for a new
switch layout, please supply all required
specifications, and mounting dimensions
according to approved track plans (contact your
ASTS USA Account Executive for any assistance
needed).
Request ASTS USA Service Manual SM-9671 for
switch machine replacement parts.
Configuration Guide
A-H
(References not used in this catalog
edition.)
I
Aluminum paint
J, L
(References not used in this catalog
edition.)
Order No.
N43925101
N43925102
M-23A Switch Machines with Independent Point Detection
Motor
Layout
Options
(Vdc)
Left-Hand
I, M
110
Right-Hand
I, M
110
Gear
Ratio
189:1
189:1
Speed
(Sec.)
5
5
Control
Circuit Wiring
3-wire
3-wire
Order No.
N43925201
N43925502
M-23B Switch Machines with Independent Point Detection
Motor
Layout
Options
(Vdc)
Left-Hand
I, M
110
Right-Hand
I, M
110
Gear
Ratio
189:1
189:1
Speed
(Sec.)
5
5
Control
Circuit Wiring
3-wire
3-wire
RSE-6A3, p. 9
Ansaldo STS USA
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-3 Switch Machine with Mechanical Circuit Controller: Specifications and Ordering Information
Ordering Information (cont’d)
•
•
•
•
Specifications
Weight:
Dimen. (Overall):
Motor Type:
Motor Voltages:
Motor RPM:
Operating Times*:
Clutch Settings:
Control Ckt. Wiring:
•
810 lbs. (367 kg)
63.5” L x 33” W x 10.25” H (161.3
cm L x 83.8 cm W x 26.0 cm H)
Fully enclosed perm. magnet type
20 Vdc or 110 Vdc (see tabs.)
500 RPM for 528:1 geared mach.
650 RPM for 360:1 geared mach.
1450 RPM for 189:1 geared mach.
4.5, 8.0 and 26.0 sec. (see tabs.)
(*Per AREMA standards. Times will
vary depending upon actual operating
conditions.)
14A for 189:1 gearing
3-wire or 5-wire (see ordering tabs)
Ordering Information
•
To order a standard M-3 switch machines with
mechanical circuit controller:
‐
Refer to “Configuration Guide” at right. Guide gives
all available design and operating options, each
denotes with a letter.
‐
Go to ordering tabulations and select machine with
desired options.
‐
Also select machine according to desired motor
voltage, operating speed and gear ratio.
RSE-6A3, p. 10
Refer to RSE-6A4 for the following support equipment:
‐
Permanent magnet retrofit motor kits for old style M3, M-23A and M-23B machines.
‐
Latchout kit.
‐
Latch stand.
‐
Point detector bars
‐
Lock rods and lock connecting rods
Refer to RSE-6F3 to order retrofit Electronic Circuit
Controller (ECC) for style “M” machines with mechanical
circuit controllers.
Refer to RSE-6J1 for tools (switch layout and shop
maintenance) used to maintain style “M” machines.
If ordering style M-3 machines for a new switch layout,
please supply all required specifications, and mounting
dimensions according to approved track plans (contact
your ASTS USA Account Executive for any assistance
needed).
Request ASTS USA Service Manual SM-6263 for switch
machine replacement parts.
Configuration Guide
A
15W, 230V Heater in Circuit Controller
Compartment
B
15W, 230V Heater for Motor
C
15W, 115V Heater in Circuit Controller
Compartment
D
15W, 115V Heater for Motor
E
15W, 115/230V Heater in Circuit Controller
Compartment
F
15W, 115/230V Heater for Motor
G
15W, 24V Heater in Circuit Controller Compartment
H
15W, 24V Heater for Motor
J
Lock Rod Openings Closed
K
Provided without Main Terminal Board
L
Uses Harness N320067 (Flag Type Terminals)
M
Uses Harness N320069 (Flag Type Terminals)
N
Uses Circuit Controller without Point. Detector
Latch
O
Clutch Set at 14 Amperes
P
Clutch Set at 10 Amperes
Q
Assembled without Latch for Retaining Machine in
the Off-Power Position when Hand Crank Cover is
Open
R
Aluminum Paint
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-3 Switch Machine with Mechanical Circuit Controller: Specifications and Ordering Information
Configuration Guide (cont’d)
S
LH Switch Machine Set Up for RH Indication or RH
Switch Machine Set Up for LH Indication
T
15w, 115v Heater for Motor.
U
Equipped With Telephone Jack in the Circuit
Controller Compartment
V
For LH Switch Machine Set Up for RH Indication
Machine is Stenciled “LH Far Pt Cl.”
For RH Switch Machine Set Up for LH Indication
Machine is Stenciled “RH Far Pt. Cl.”
Order No.
N451160-0301
N451160-0302
N451160-0303
N451160-0304
N451160-0305
N451160-0306
N451160-0307
N451160-0308
N451160-0309
N451160-0310
N451160-0311
N451160-0312
N451160-0313
N451160-0314
N451160-0315
N451160-0316
N451160-0317
N451160-0318
N451160-0319
N451160-0320
N451160-0322
N451160-0323
N451160-0324
N451160-0325
N451160-0326
W
X
Y
1-1/4” Threaded Conduit Outlet
Uses Crank Case Cover (N146290-002) Pipe Plug
(J032902) Not Required
(Reference not used in this catalog edition.)
Standard M-3 Switch Machines with Mechanical Circuit Controller
Motor
Gear
Layout
Options
(Vdc)
Ratio
Right Hand
C, L
20
528:1
Left Hand
C, L
110
528:1
Right Hand
C, M
110
189:1
Left Hand
C, M
110
189:1
Right Hand
C, D
110
189:1
Left Hand
C, D
110
189:1
Right Hand
C, D
110
189:1
Left Hand
C, D
110
189:1
Left Hand
E, F
110
189:1
Right Hand
E, F
110
189:1
Left Hand
C, D, J
110
189:1
Right Hand
C, D, J
110
189:1
Right Hand
X
110
189:1
Left Hand
X
110
189:1
Right Hand
C, D, Q
110
189:1
Left Hand
C, D, Q
110
189:1
Right Hand
-110
189:1
Left Hand
-110
189:1
Right Hand
C, D
110
189:1
Left Hand
C, D
110
189:1
Left Hand
D, S, W
110
189:1
Right Hand
D, S, W
110
189:1
Left Hand
C, D, J
110
189:1
Right Hand
C, D, J
110
189:1
Left Hand
C, D, P, S
110
360:1
Speed
(Sec.)
26.0
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
8.0
Control
Circuit Wiring
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
5-Wire
3-Wire
3-Wire
5-Wire
5-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
(Tabulation continued on following page.)
RSE-6A3, p. 11
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
RSE-6A3
Rev. 3-09
M-3 Switch Machine with Mechanical Circuit Controller: Specifications and Ordering Information
(Tabulation continued from previous page.)
Order No.
N451160-0327
N451160-0328
N451160-0329
N451160-0330 (1)
N451160-0331 (1)
N451160-0332
N451160-0333
N451160-0334
N451160-0335
N451160-0336
N451160-0337
N451160-0338 (1)
N451160-0339 (1)
N451160-0340
N451160-0341
N451160-0342
N451160-0343
N451160-0344
N451160-0345
N451160-4001
N451160-4002
N451160-4003
N451160-4004
N451160-4005
N451160-4006
RSE-6A3, p. 12
Standard M-3 Switch Machines with Mechanical Circuit Controller
Motor
Gear
Speed
Layout
Options
(Vdc)
Ratio
(Sec.)
Right Hand
C, D, P, S
110
360:1
8.0
Left Hand
C, D, J, R
110
189:1
4.5
Right Hand
C, D, J, R
110
189:1
4.5
Left Hand
C, T, U
110
189:1
4.5
Right Hand
C, T, U
110
189:1
4.5
Left Hand
C, D, J, P
110
360:1
8.0
Right Hand
C, D, J, P
110
360:1
8.0
Left Hand
C, D, J, P
110
360:1
8.0
Right Hand
C, D, J, P
110
360:1
8.0
Left Hand
C, D, J, P, S
110
360:1
8.0
Right Hand
C, D, J, P, S
110
360:1
8.0
Left Hand
C, T, U, S
110
189:1
4.5
Right Hand
C, T, U, S
110
189:1
4.5
Left Hand
C, D, S, V
110
189:1
4.5
Right Hand
C, D, S, V
110
189:1
4.5
Left Hand
C, D, U
110
189:1
4.5
Right Hand
C, D, U
110
189:1
4.5
Left Hand
C, D, S, U, V
110
189:1
4.5
Right Hand
C, D, S, U, V
110
189:1
4.5
Left Hand
C, D, J
110
189:1
4.5
Right Hand
C, D, J
110
189:1
4.5
Left Hand
C, D, P, S, V
110
360:1
8.0
Right Hand
C, D, P, S, V
110
360:1
8.0
Left Hand
C, D, J
110
189:1
4.5
Right Hand
C, D, J
110
189:1
4.5
Note (1): Machines available for replacement of Alstom/GRS machines with 2-wire control.
Request Service Manual SM-6263 or contact ASTS USA for conversion kit.
These machines include two 15W/115V heaters (for motor and circuit controller),
and telephone jack in circuit controller compartment. -0338 and -0338 machines
are L.H. for R.H. indication, or R.H. for L.H. indication.
Control
Circuit Wiring
3-Wire
3-Wire
3-Wire
2-Wire
2-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
2-Wire
2-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
3-Wire
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-3 Machines with ECC and EBNC: Specifications and Ordering Information
Ordering Information (cont’d)
Specifications
Weight:
Dimen. (Overall):
Motor Type:
Motor Voltages:
Motor RPM:
Operating Times*:
Clutch Settings:
Control Ckt. Wiring:
810 lbs. (367 kg)
63.5” L x 33” W x 10.25” H (161.3
cm L x 83.8 cm W x 26.0 cm H)
Fully enclosed perm.magnet type
20 Vdc or 110 Vdc (see tabs.)
500 RPM for 528:1 geared mach.
650 RPM for 360:1 geared mach.
1450 RPM for 189:1 geared
machines
4.5 or 8.0 sec. (see tabs)
(*Per AREMA standards. Times will
vary depending upon actual operating
conditions.)
14A for 189:1 gearing
2-wire
Ordering Information
•
To order M-3 switch machines with ECC and EBNC:
‐
Refer to “Configuration Guide” below. Guide gives all
available design and operating options, each denotes
with a letter.
Order No.
N42950013
N42950014
•
•
•
‐
Go to ordering tabulations and select machine with
desired options.
‐
Also select machine according to desired motor
voltage, operating speed and gear ratio.
Refer to RSE-6J1 for tools (switch layout and shop
maintenance) used to maintain style “M” machines.
If ordering M-3 machines for a new switch layout, please
supply all required specifications, and mounting
dimensions according to approved track plans (contact
your ASTS USA Account Executive for any assistance
needed).
Request ASTS USA Service Manual SM-9662 for switch
machine replacement parts.
Configuration Guide
A
15-Watt, 115V Motor Heater
B, C
(References not used in this catalog edition.)
D
Equipped with Local/Remote Feature
E-K
(References not used in this catalog edition.)
L
Surge Suppressor PCB
Standard M-3 Machines with ECC and EBNC
Motor
Gear
Control
Layout
Options
(Vdc)
Ratio
Circuit Wiring
Left Hand
A, D, L
110
189:1
2-wire EBNC
Right Hand
A, D, L
110
189:1
2-wire EBNC
Note (1): Wayside provides fixed-polarity 2-wire motor power feed. One wire always
"+" and other wire always "-". ECC/EBNC controls polarity applied to motor
terminals to select Normal or Reverse operation.
Notes
(1)
(1)
RSE-6A3, p. 13
Ansaldo STS USA
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
M-3 Machines with Independent Point Detection: Specifications and Ordering Information
Ordering Information (cont’d)
Specifications
Weight:
Dimen. (Overall):
Motor Type:
Motor Voltages:
Motor RPM:
Operating Times*:
Clutch Settings:
Control Ckt. Wiring:
810 lbs. (367 kg)
63.5” L x 33” W x 10.25” H (161.3
cm L x 83.8 cm W x 26.0 cm H)
Fully enclosed perm. magnet type
20 Vdc or 110 Vdc (see tabs.)
500 RPM for 528:1 geared mach.
650 RPM for 360:1 geared mach.
1450 RPM for 189:1 geared mach.
3.0 sec.
(*Per AREMA standards. Times will
vary depending upon actual operating
conditions.)
All machines: 14A for 189:1 geared
mach.
3-wire
Ordering Information
•
To order M-3 or switch machines with independent point
detection:
‐
Refer to “Configuration Guide” below. Guide gives all
available design and operating options, each denotes
with a letter.
Order No.
N43925001
N43925002
RSE-6A3, p. 14
•
•
•
‐
Go to ordering tabulations and select machine with
desired options.
‐
Also select machine according to desired motor
voltage, operating speed and gear ratio.
Refer to RSE-6J1 for tools (switch layout and shop
maintenance) used to maintain style “M” machines.
If ordering M-3 machines for a new switch layout, please
supply all required specifications, and mounting
dimensions according to approved track plans (contact
your ASTS USA Account Executive for any assistance
needed).
Request ASTS USA Service Manual SM-9671 for switch
machine replacement parts.
Configuration Guide
A
15W, 115V Heater in Circuit Controller
Compartment
B
15W, 115V Heater in Motor Compartment
C-L
(References not used in this catalog edition.)
M
Circuit Controller without Latch Cam Block
M-3 Switch Machines with Independent Point Detection
Motor
Layout
Options
(Vdc)
Left-Hand
A, B, M
110
Right-Hand
A, B, M
110
Gear
Ratio
189:1
189:1
Speed
(Sec.)
3
3
Control
Circuit Wiring
3-wire
3-wire
M-23A, M-23B, M-3 and Low-Profile
M-3 Electric Switch Machines
Ansaldo STS USA
(Formerly known as Union Switch & Signal)
RSE-6A3
Rev. 3-09
Low-Profile M-3 Machines: Specifications and Ordering Information
Specifications
Weight:
Dimen. (Overall):
Ordering Information
Motor Type:
Motor Voltage:
Motor RPM:
Gear Ratio:
Op. Bar Stroke:
Operating Time*:
Clutch Setting:
Control Ckt. Wiring:
810 lbs. (367 kg)
Length: 63.5” (161.3 cm)
Width: 19” W (48.25 cm) - not
including bars and covers.
Height: With mounting plate = 9-7/8”
(25.1 cm)
Height: Without mounting plate = 95/8” (24.4 cm)
Fully enclosed permanent magnet
type
110 Vdc
1430 RPM
189:1
6” (15.2 cm)
5.0 seconds
(*Per AREMA standards. Times will
vary depending upon actual operating
conditions.)
13A
3-wire
•
•
•
•
To order a Low Profile M-3 switch machine, refer to
tabulation below.
If ordering style M-3 machines for a new switch layout,
please supply all required specifications, and mounting
dimensions according to approved track plans (contact
your ASTS USA Account Executive for any assistance
needed).
Refer to RSE-6J1 for tools (switch layout and shop
maintenance) used to maintain style “M” machines.
Request ASTS USA Service Manual SM-6444 for switch
machine replacement parts.
Low-Profile M-3 Switch Machine with Mechanical Circuit Controller
Point
Motor
Speed
Gear
Clutch
Det.
Order No.
Layout
(Vdc)
(Sec.)
Ratio
Control
Setting
Latch
N451160-1401
Left-Hand
110
4.5
189:1
3-Wire
13A
X
N451160-1501
Right-Hand
110
4.5
189:1
3-Wire
13A
X
Note (1): Machines equipped with circuit controller and motor compartment heaters.
Heaters
(1)
X
X
MicroLok® is a registered trademark of Ansaldo STS USA, Inc.