* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download HP 10500 2500W AC Power Supply (JC610A) User Guide
Power inverter wikipedia , lookup
Buck converter wikipedia , lookup
Power factor wikipedia , lookup
Voltage optimisation wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Wireless power transfer wikipedia , lookup
Standby power wikipedia , lookup
Alternating current wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electric power system wikipedia , lookup
Audio power wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Electrification wikipedia , lookup
Power engineering wikipedia , lookup
Power over Ethernet wikipedia , lookup
Rectiverter wikipedia , lookup
Mains electricity wikipedia , lookup
Power supply unit (computer) wikipedia , lookup
Switched-mode power supply wikipedia , lookup
HP 10500 2500W AC Power Supply (JC610A) User Guide Part number: 5998-2201R ▌Power supply overview The AC2500 (JC610A) is a power supply with AC input and DC output. It can provide up to 2500 W DC output. The AC2500 has the following features: Table 1 Features of the 2500 W AC power supply Feature Description Protection function Protection for under-voltage input, over-voltage input, over-voltage output, output short circuit, under-current output, over-current output, and overheat. Support for hot swapping You can plug in or unplug the power supply when the device is operating properly. Support for redundancy The power supplies can operate in N+1 or N+N redundant mode. For more information, see "Power supply configuration." CAUTION: • AC2500 cannot work with other models of power supplies in the same device. • When the temperature of the power supply is higher than the upper limit of the operating temperature, the power supply automatically shuts down. When the temperature falls into the normal range, the power supply automatically starts. 1 Front panel Figure 1 Front panel of AC2500 (1) Captive screw (3) Power receptacle (5) Power input status LED (2) Power supply handle (4) Power output status LED LEDs A power supply has two status LEDs. The following table lists the LED status and description. Table 2 2500W AC LED description LED Sign Color Description The power supply has no power input. Power input AC Off The input voltage is too low, and the power supply enters the protected state. Green The power input is normal. 2 LED Power output Sign Color Description Green The power output is normal. Red The power supply encounters exceptional power output problems. In other words, when output short circuit, over-current output, over-voltage output, under-voltage input, or remote shutdown occurs, the power supply enters the protected state. Orange The temperature of the power supply is too high, and the power supply enters the protected state. DC CAUTION: • If a power supply has no power input, or the connected circuit breaker is off, but another power supply is providing power to the system, it is normal that the power output status LED is red. • After the circuit breaker that connects to a power supply is off, it is normal that the LEDs on the power supply last on for a while. Technical specifications Table 3 Technical specifications for the 2500W AC Item Specifications Rated input voltage 100 to 240 VAC (50/60 Hz) Rated output voltage 12 VDC Maximum input current 16 A Maximum output current Maximum output power Dimensions (H × W × D) • 208 A @ 220 VAC • 100 A @ 110 VAC • 1200 W @ 110 VAC • 2500 W @ 220 VAC 41 × 102 × 391 mm (1.61 × 4.00 × 15.36 in) 3 Item Ambient temperature Specifications Operating temperature –10°C to +50°C (–14°F to +122°F) Storage temperature –40°C to +85°C (–40°F to +185°F) Power supply configuration You can determine the number of power supplies to be configured for the system according to the actual power consumption and power supply conditions. • In an environment with two mains power inputs, you can configure N+N redundant mode. • In an environment with only one mains power input, you can configure N+1 or N+N redundant mode. • For easy usage and maintenance, be sure to configure a proper circuit breaker for each power input. The rated current of the circuit breaker must be more than 20 A. NOTE: In the term N+1 and N+N, the value of N depends on the number of power supply slots in the device. N+1 or N+N must not be more than the total number of power supply slots. ▌Installing and removing a power supply Installing a power supply Figure 2 illustrates the flow for installing a power supply. Strictly follow the sequence to avoid possible dangers. 4 Figure 2 Installation flow of a power supply NOTE: The device needs at least one power supply to provide power supply, so the chassis has a power supply slot without a blank panel. For this slot, you can skip "Remove the blank panel" in the figure above. Before the installation, prepare an ESD-preventive wrist strap and a Phillips screwdriver. Installing the power supply 1. Wear an ESD-preventive wrist strap, and make sure the wrist strap makes good skin contact and is properly grounded. 2. Use the Phillips screwdriver to unfasten the captive screws on the blank panel, and remove the blank panel from the slot to be used (see callout 2 in the figure). 5 Figure 3 Removing the blank panel (1) Unfasten the captive screws on the blank panel (2) Remove the blank panel NOTE: A power supply can be vertically or horizontally installed according to the power supply slot, but the installation methods are similar. This document takes the vertical installation method as an example, and gives different diagrams for key steps. 3. Unpack the power supply. 4. Holding the handle of the power supply with one hand and supporting the bottom of the power supply with the other, slide the power supply along the guide rails into the slot. NOTE: The blank panel is printed with a diagram of correct installation direction. You can follow the instruction to install the power supply. As shown in Figure 4 (vertical installation) and Figure 5 (horizontal installation), be sure of the correct direction of the power supply. 6 Figure 4 Installing the power supply into a vertical slot 7 Figure 5 Installing the power supply into a horizontal slot 5. Press the handle back into the notch of the power supply. 6. Use the Phillips screwdriver to fasten the captive screw on the handle to secure the power supply. Connecting the power cord WARNING! • Make sure each power cord has a separate circuit breaker. • Turn off the circuit breaker before connecting the power cord. To connect the power cord: 1. Plug the AC power cord connector into the receptacle of the power supply. 2. Route the power cord along the cabling rack, and fasten the power cord by using cable ties. 8 NOTE: The cabling rack position varies by switch model. Route the cable as required. • For how to fasten the power cord connected to a vertically-installed power supply, see Figure 6 • For how to fasten the power cord connected to a horizontally-installed power supply, see Figure 7. Figure 6 Fastening the power cord connected to a vertically-installed power supply 9 Figure 7 Fastening the power cord connected to a horizontally-installed power supply 3. Plug the other end of the power cord into an AC power receptacle of the power source, and turn on the connected circuit breaker. 4. Verify that the input status LED is ON. It indicates that the power cord is correctly connected. If the input status LED is OFF, troubleshoot the installation process until the input status LED is ON. Removing a power supply Figure 8 illustrates the flow for removing a power supply. Strictly follow the sequence to avoid possible dangers. 10 Figure 8 Removal flow of a power supply NOTE: The device needs at least one power supply to provide power supply, so the chassis has a power supply slot without a blank panel. For this slot, you can skip "Install the blank panel" in the figure above. Before removing a power supply, prepare an ESD-preventive wrist strap and a Phillips screwdriver. Removing the power cord 1. Turn off the circuit breaker of the power cord. 2. Wear an ESD-preventive wrist strap, and make sure the wrist strap makes good skin contact and is properly grounded. 3. Remove the cable ties, and pull the power cord out. CAUTION: After the circuit breaker that connects to a power supply is off, it is normal that the LEDs on the power supply last on for a while. 11 Removing the power supply 1. Use the Phillips screwdriver to unfasten the captive screw on the power supply. 2. Hold the captive screw and pull out the handle of the power supply. 3. As shown in Figure 9, grasp the handle of the power supply with one hand and pull it out a little, support the bottom of the power supply with the other hand, and then pull the module slowly along the guide rails out of the slot. Figure 9 Removing the power supply 4. Put the power supply on an antistatic mat. 5. Install the blank panel back to the power supply slot, and fasten the captive screws. CAUTION: Before inserting a removed power supply into a power supply slot, make sure the LEDs on the power supply are both off. 12 ▌Documentation To access documentation and support services, go to the Hewlett Packard Enterprise Support Center website: www.hpe.com/support/hpesc 5998-2201R © Copyright 2015 Hewlett Packard Enterprise Development LP The information in this document is subject to change without notice. BOM: 3101A0DP Version: 6PW103 13