* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ORANGIS - Ambient control (Section)
Ground loop (electricity) wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical ballast wikipedia , lookup
Current source wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical engineering wikipedia , lookup
Electrical substation wikipedia , lookup
Mechanical-electrical analogies wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Mechanical filter wikipedia , lookup
Distribution management system wikipedia , lookup
Power electronics wikipedia , lookup
Anastasios Venetsanopoulos wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Buck converter wikipedia , lookup
Light switch wikipedia , lookup
Alternating current wikipedia , lookup
Rectiverter wikipedia , lookup
Ground (electricity) wikipedia , lookup
Surge protector wikipedia , lookup
Voltage optimisation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
National Electrical Code wikipedia , lookup
186 C O N T R O L S Y S T EM S Command, control and regulation Mechanical regulators ............................................................................................... 188 ––NO-NC thermostats ..................................................................................... 191 ––Twin thermostats ............................................................................................ 192 ––Change-over thermostats ........................................................................ 193 ––Hygrostats .......................................................................................................... 194 Flashing signal device ............................................................................................... 195 Door limit switches ...................................................................................................... 197 REGULATORS Accessories ....................................................................................................................... 199 Most of our products are available in the industrial engineering software: 187 Regulators Introduction MECHANICAL REGULATORS Temperature and humidity regulators help to guarantee the optimal conditions inside the enclosure for trouble-free operations with electrical components. They are used for controlling fan filters, heaters or for switching signal devices. NO-NC THERMOSTATS VERSIONS Available with normally closed, normally open and change over contacts SET POINT Wide temperature setting range with Celsius or Fahrenheit scales ELECTRICAL CONNECTION Screw terminals SIMPLE MOUNTING Snap-on fastening system for DIN rails APPLICATIONS Switching contact for fan filters, heaters and cooling unit or signal devices Details that make the difference C° e F° scales 188 ■ Fandis Disk setting by hand or tool Patented clip system Regulators Introduction TWIN THERMOSTATS Twin thermostats integrate two independently switchable devices within one compact unit, allowing the simultaneous control of heating and cooling equipment or signaling equipment. VERSIONS Available with normally closed/normally open, normally closed/normally closed and normally open/normally open contacts SIMPLE MOUNTING Snap-on fastening system for 35mm DIN rails DUAL SYSTEM Separate adjustment and operation APPLICATIONS Switching contact for fan filters, heaters and cooling unit or signal devices SET POINT Wide temperature setting range with Celsius or Fahrenheit scales REGULATORS ELECTRICAL CONNECTION Screw terminals Model numbering system for NO-NC Thermostats and Twins Thermostats description TRT 10A 230V - NC F PAxx description FAMILY TRT TRT = single thermostat TRT2 = twins thermostat CUSTOM SERIES PAxx = custom version RATED CURRENT SCALE (Blank) = C° (Celsius) F = F° (Fahrenheit) RATED VOLTAGE VERSION Single thermostat NC = Normally Closed NO = Normally Open Twins thermostat NCNC = Normally Closed / Normally Closed NCNO = Normally Closed / Normally Open NONO = Normally Open / Normally Open Fandis ■ 189 Regulators Introduction HYGROSTATS When used with heaters or fan filters, hygrostats keep the relative humidity (RH) levels of enclosures below the dew point and prevent condensation forming on electrical components. VERSIONS Available with normally closed/normally open, normally closed/normally closed and normally open/normally open contacts ELECTRICAL CONNECTION Screw terminals SIMPLE MOUNTING Snap-on fastening system for 35mm DIN rails APPLICATIONS Combined with heaters or fan filters for a precise control of humidity levels Model numbering system for Hygrostats description FAMILY IGR IGR = Hygrostat Support 35mm DIN rail 190 ■ Fandis IGR 35 F - PAxx description CUSTOM SERIES PAxx = custom version VERSION F = Fandis TRT °C °F Thermostats NO NC mechanical General specifications • Snap-on mounting on: - DIN rail TS 35, according to EN 50 022 - DIN rail TS 15, according to EN 50 045 - DIN rail TS 32, according to EN 50 035 • Housing in self-extinguishing PA66, according to UL 94V-0 • Standard colour grey RAL 7035 • Screw terminals for electrical connection to wires with sections from 0.75mm2 to 2.5mm2 (18÷13 AWG) • Bi-metallic sensing element • Normally Closed (NC) red knob, Normally Open (NO) blue knob • CEI EN 60730-1 applied standard • CEI EN 60730-2-9 applied standard • UL (Underwriters Laboratories) approved, according to UL 873 and C22.2 No. 24-93 standards ffPatented fastening system on DIN rails TS35/15/32 ffGraduated disc rotatable by hand or tool Technical data Rated Voltage Range Rated Current Contact Current Setting Range Setting Range V A A °C °F TRT-10A230V-NC 60 V d.c.;110-250 V a.c. 10 15 -10 ~ 80 TRT-10A230V-NCF 60 V d.c.;110-250 V a.c. 10 15 Model 60 V d.c.;110-250 V a.c. 10 15 TRT-10A230V-NOF 60 V d.c.;110-250 V a.c. 10 15 -10 ~ 80 Weight Approvals K K Kg -3 ±3 0.07 CE; cURus; -3 ±3 0.07 CE; cURus; ±3 0.07 CE; cURus; ±3 0.07 CE; cURus; +4 if A < 5 ; +7 if A > 5 +4 if A < 5 ; 14 ~ 176 +7 if A > 5 REGULATORS TRT-10A230V-NO 14 ~ 176 Differential (referred to Accuracy set point) TRT ° C TRT ° F 45 45 29 72 72 29 Fandis ■ 191 TRT2 °C °F Twin thermostats NONC NONO NCNC mechanical General specifications • Snap-on mounting on DIN rail TS 35, according to EN 50 022 • Housing in self-extinguishing PC/ABS, according to UL 94V-0 • Standard colour grey RAL 7035 • Screw terminals for electrical connection to wires with sections from 0.75mm2 to 2.5mm2 (18÷13 AWG) • Bi-metallic sensing element • Normally Closed (NC) red knob, Normally Open (NO) blue knob • CEI EN 60730-1 applied standard • CEI EN 60730-2-9 applied standard • UL (Underwriters Laboratories) approved, according to UL 873 and C22.2 No. 24-93 standards ffGraduated disc rotatable by hand or tool Technical data Model Rated Voltage Range V Rated Contact Setting Current Current Range A A °C Setting Range °F TRT2-10A230V-NCNC 60 V d.c.;110-250 V a.c. 10 + 10 15 + 15 -10 ~ 80 TRT2-10A230V-NCNCF 60 V d.c.;110-250 V a.c. 10 + 10 15 + 15 Differential Accuracy Weight (referred to set point) K K Kg -3 ±3 0.14 CE; cURus; -3 ±3 0.14 CE; cURus; ±3 0.14 CE; cURus; ±3 0.14 CE; cURus; +4 if A < 5 ; +7 if A > 5 ±3 0.14 CE; cURus; 14 ~ 176 +4 if A < 5 ; +7 if A > 5 ±3 0.14 CE; cURus; 14 ~ 176 -3 (NC) / +4 if A < 5 ; +7 10 + 10 15 + 15 -10 ~ 80 if A > 5 (NO) -3 (NC) / +4 if A < 5 ; +7 10 + 10 15 + 15 14 ~ 176 if A > 5 (NO) TRT2-10A230V-NCNO 60 V d.c.;110-250 V a.c. TRT2-10A230V-NCNOF 60 V d.c.;110-250 V a.c. TRT2-10A230V-NONO 60 V d.c.;110-250 V a.c. 10 + 10 15 + 15 -10 ~ 80 TRT2-10A230V-NONOF 60 V d.c.;110-250 V a.c. 10 + 10 15 + 15 TRT2 ° C TRT2 ° F 45 45 ■ Fandis 58 72 72 58 192 Approvals TRT01 Thermostats change-over mechanical General specifications • Snap-on mounting on DIN rail 35mm, according to EN 50 022 • Housing in PC/ABS • Standard colour grey RAL 7035 • Screw terminals for electrical connection to wires with sections from 0.75mm2 to 2.5mm2 • Bi-metallic sensing element with thermal retroaction • EN 60730-1 applied standard 3 Technical data TRT-230V-S01 Rated Voltage Range Rated Current Contact Current Setting Range V A A 230 V a.c. Technical specifications (Heating) a.c. 10(4) (Cooling) a.c. 5(2) 10 Differential (referred to set point) Accuracy Weight °C K K Kg 5° ~ 60° 1 (with thermal retroaction) ±3 0.07 Approvals CE; Technical drawing REGULATORS Model Fandis ■ 193 IGR Hygrostats change-over mechanical General specifications • Snap-on mounting on DIN rail 35mm, according to EN 50 022 • Housing in PC/ABS alloy • Standard colour grey RAL 7035 • Screw terminals for electrical connection to wires with sections from 0.75mm2 to 4.0mm2 • Synthetic fibre sensing element • EN 60730-1 and CISPR 14-1 standards applied • UL (Underwriters Laboratories) approved, according to UL60730-1 e CAN/CSA-E60730-1, CAN/CSA-E730-2-2 ffGraduated disc rotatable by hand or tool Technical data Model IGR35F Rated Voltage Range ■ Fandis Setting Range Differential average Differential max Accuracy Weight V A %RH %RH %RH %RH Kg 120 - 240 12 - 6 ; 6 - 3 10 - 90 5 10 ±5 0.18 Technical specifications 194 Rated Current Technical drawing Approvals CE; cURus; Regulators Introduction FLASHING SIGNAL DEVICE Flashing devices ensure safety for enclosure inspections. They help prevent accidents by alerting operators when doors are opened of live voltage within the electrical system through flashing lights. VISUAL SIGNAL 3 red flashing lights indicating live voltage presence AUXILIARY CONTACTS Can be integrated with a limit or interlock switches REGULATORS CLOSE DOOR SIMULATION Power is restored to permit maintenance operations Fandis ■ 195 FD01 FD02 FD03 Flashing signal device 110-500V electronic General specifications • Thermoplastic casing • Fixing by screws (M4) or by adjustable bracket (FD02, FD03) • Screw terminals for electrical connection: - flexible cable from 0.14mm2 to 2.5mm2 - rigid or tin cable from 0.14mm2 to 4mm2 • CEI EN 60947-5-1, UL 508 applied standards • Suitable for connection to single or three-phase systems Technical data Model Rated Voltage Range Working Temp.Range V °C Approvals FD01 110-290 V~; 220-500 V 3~ -25°C ~ 70°C CE; cURus; FD02 110-290 V~; 220-500 V 3~ -25°C ~ 70°C CE; FD03 110-290 V~; 220-500 V 3~ -25°C ~ 70°C CE; FD01 FD02 30 37 Technical specifications 100 94 4,5 75 113,2 86 194 6,5 225 110 239 37 44,9 FD03 122 75 194 6,5 225 239 196 ■ Fandis Regulators Introduction DOOR LIMIT SWITCHES Limit switches are a practical solution for sensing applications in enclosures. They are mechanically activated to switch on the lamp or switch off live voltage inside the cabinet. REGULATORS VERSIONS Different type of plungers and contacts Fandis ■ 197 FC 01 02 03 04 05 Door limit switches mechanical General specifications • Plastic casing • Screws terminal for electrical connection and one cable inlet for PG13.5 cable gland • IEC 947-5-1 / EN 60947-5-1 applied standard • Fixing by No. 2 M4 screws • Plain plunger (FC-001), plain plunger with manual reset (FC-002), roller plunger (FC-003), adjustable lever (FC-004), plain plunger with 3 NC contacts (FC-005) • UL approval according to UL 508 and CSA approval according to CSA/CAN 22.2 No. 14 Technical data Model a.c. Rated Voltage Range a.c. Rated Current Range d.c. Rated Voltage Range d.c. Rated Current Range Mechanical Durability Approvals V A V A Mil. of oper. FC-001 24 - 400 10 - 1.8 24 - 250 2.8 - 0.27 15 CE; cULus; FC-002 24 - 400 10 - 1.8 24 - 250 2.8 - 0.27 1 CE; cULus; FC-003 24 - 400 10 - 1.8 24 - 250 2.8 - 0.27 15 CE; cULus; FC-004 24 - 400 10 - 1.8 24 - 250 2.8 - 0.27 10 CE; cULus; FC-005 24 - 400 10 - 1.8 24 - 250 2.8 - 0.27 15 CE; cULus; Technical specifications FC-001 / FC-005 PLAIN PLUNGER FC-002 PLAIN PLUNGER WITH MANUAL RESET 73 90.5 Ø8 30.3 Ø8 30.3 17 53.5 53 37 20 12.5 39 29.9 12.5 30 Ø15 FC-003 ROLLER PLUNGER FC-004 WITH ADJUSTABLE LEVER 98.5/170.5 84 17.5 28/100 19/91 Ø18 30.3 Ø11 30.3 53 53 31 30 45.5 42 12.5 30 3.5 5.5 198 ■ Fandis SA-FC01 Accessories - regulators slide limit switch General specifications Plastic support for a fast installation and a simple positioning of our FC series door limit switch. The kit consist of: - n.1 slide for limit switch in PA6 H-V0 - n.2 screws for fixing to limit switch, tcb Phil ac 4.8 znb M4x30 - n.2 nuts M4 Technical data Model SA-FC01K Technical drawing 11.5 40 REGULATORS 6.5 30 31.5 65 21 5.1 4 10 20 Technical specifications 6.5 50 Fandis ■ 199