* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Description
Power factor wikipedia , lookup
Electrical substation wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Current source wikipedia , lookup
Utility frequency wikipedia , lookup
Stray voltage wikipedia , lookup
Electric battery wikipedia , lookup
Power engineering wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Schmitt trigger wikipedia , lookup
Rechargeable battery wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Voltage regulator wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power inverter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
UPS5000 V100R002C00 Feature Description Issue 01 Date 2013-01-26 HUAWEI TECHNOLOGIES CO., LTD. Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: [email protected] Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. i UPS5000 Feature Description Contents Contents 1 Basic Features ................................................................................................................................. 1 1.1 System Features ............................................................................................................................................................ 1 1.2 Input Features ............................................................................................................................................................... 5 1.3 Bypass and Output Features ......................................................................................................................................... 7 1.4 Battery Features .......................................................................................................................................................... 11 1.5 System Features .......................................................................................................................................................... 13 1.6 User Interface Features ............................................................................................................................................... 15 1.7 Alarm Features ............................................................................................................................................................ 17 2 Optional Features ........................................................................................................................ 21 2.1 Environmental Features .............................................................................................................................................. 21 2.2 Power Distribution Features ....................................................................................................................................... 22 2.3 Parallel System Features ............................................................................................................................................. 22 2.4 Battery Features .......................................................................................................................................................... 23 2.5 Monitoring Features.................................................................................................................................................... 24 3 Acronyms and Abbreviations ................................................................................................... 26 Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. ii UPS5000 Feature Description 1 Basic Features 1 Basic Features This document describes the features of UPS5000 V100R002. 1.1 System Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-010101 The UPS5000-E complies with the International Electrotechnical Commission (IEC), YD/T1095-2008, and other related standards and has passed Conformite Europeenne (CE), Certification Bodies' Scheme (CB), and Tell Certification Center (TLC) certification. One Key-010102 The UPS delivers an efficiency of up to 95.5% (dual conversion mode). One Key-010103 The full-digital design improves system stability and maintainability. One Key-010104 The UPS has a small footprint and a high power density. The system has dimensions (H x W x D) of 264 mm x 500 mm x 800 mm (excluding the terminal cover). One Key-010105 The UPS is embedded with a static bypass switch and a maintenance bypass switch. One Key-010106 The UPS is suitable for various loads, including capacitive, inductive, and non-linear loads. The inductive and capacitive loads with a power factor (PF) of greater than 0.5 are not derated. One Key-010107 The UPS supports a wide range of operating temperatures. It works at full load at 0°C to 40°C. One Key-010108 The unit-level design greatly shortens maintenance time. One Key-010109 The UPS can be rack or tower mounted. It can be installed in a Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 1 Feature ID Feature Name 19-inch standard cabinet. One Key-010110 The UPS supports self-load. Customers can perform battery discharge tests onsite. One Key-010111 The fan speed varies depending on the ambient temperature and load power, which reduces noises. Fans are configured in redundancy. One Key-010112 Abundant optional components contribute to an integrated solution. One Key-010113 The UPS complies with restriction of the use of certain hazardous substances (RoHS) 6. One Key-010114 Cables are routed from the bottom. One Key-010115 The UPS is protected to IP20. One Key-010116 The software supports online upgrade. Feature ID Feature Name Benefit One Key-010101 The UPS5000-E complies with the IEC, YD/T1095-2008, and other related standards and has passed CE, CB, and TLC certification. The UPS complies with safety regulations and meets One Key-010102 The UPS delivers an efficiency of up to 95.5% (dual conversion mode). The UPS features high efficiency, energy efficiency, and resource utilization. One Key-010103 The full-digital design improves system stability and maintainability. This feature increases the power density and improves reliability. One Key-010104 The UPS has a small footprint and a high power density. The system has dimensions (H x W x D) of 264 mm x 500 mm x 800 mm (excluding the terminal cover). This feature improves space utilization and provides reserved space for redundancy and expansion. One Key-010105 The UPS is embedded with a static bypass switch and a maintenance bypass switch. This feature implements online maintenance. One Key-010106 The UPS is suitable for various loads, including capacitive, inductive, and non-linear loads. The inductive and capacitive loads with a PF of greater than 0.5 are not derated. The UPS is suitable for various loads in various scenarios. Benefits Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. electromagnetic compatibility (EMC), and performance requirements. 2 Feature ID Feature Name Benefit One Key-010107 The UPS supports a wide range of operating temperatures. It works at full load at 0°C to 40°C. The UPS supports a wide range of operating temperatures. One Key-010108 The unit-level design greatly shortens maintenance time. This feature shortens the maintenance time. One Key-010109 The UPS can be rack or tower mounted. It can be installed in a 19-inch standard cabinet. This feature shortens the maintenance time. One Key-010110 The UPS supports self-load. Customers can perform battery discharge tests onsite. The self-load function provides an energy-efficient test method. One Key-010111 The fan speed varies depending on the ambient temperature and load power, which reduces noises. Fans are configured in redundancy. This feature reduces fan noises, minimizing the impact on the environment. One Key-010112 Abundant optional components contribute to an integrated solution. This feature helps deliver all-around solutions that are easy to implement. One Key-010113 The UPS complies with RoHS 6. The UPS meets environmental requirements. One Key-010114 Cables are routed from the bottom. Cabling is simple and flexible. One Key-010115 The UPS is protected to IP20. The UPS meets basic protection requirements. One Key-010116 The software supports online upgrade. This feature shortens the software upgrade and maintenance time. Feature ID Feature Name Description One Key-010101 The UPS5000-E complies with the IEC, YD/T1095-2008, and other related standards and has passed CE, CB, and TLC certification. The UPS complies with the IEC62040 (safety, EMC, performance, and test methods), YD/T1095-2008, and YD/T 2165-2010 (requirements for the UPS in China's communications industry), and has passed CE and TLC certification. This feature ensures that the UPS has a market share in associated countries and regions. One Key-010102 The UPS delivers an efficiency of up to 95.5% Total output active power/Total input active power = 95.5% Description Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 3 Feature ID Feature Name Description (dual conversion mode). One Key-010103 The full-digital design improves system stability and maintainability. The digital chip control improves system integration, anti-interference capability, reliability, and maintainability. One Key-010104 The UPS has a small footprint and a high power density. The system has dimensions (H x W x D) of 264 mm x 500 mm x 800 mm (excluding the terminal cover). This feature improves system integration and high-power output capability. One Key-010105 The UPS is embedded with a static bypass switch and a maintenance bypass switch. The UPS can transfer to maintenance bypass mode, which facilitates maintenance. One Key-010106 The UPS is suitable for various loads, including capacitive, inductive, and non-linear loads. The inductive and capacitive loads with a PF of greater than 0.5 are not derated. The UPS is suitable for capacitive, inductive, and non-linear loads. One Key-010107 The UPS supports a wide range of operating temperatures. It works at full load at 0°C to 40°C. The UPS supports a wide range of operating temperatures. One Key-010108 The unit-level design greatly shortens maintenance time. If the bypass unit or power unit is faulty, replace it directly. One Key-010109 The UPS can be rack or tower mounted. It can be installed in a 19-inch standard cabinet. The availability is improved. One Key-010110 The UPS supports self-load. Customers can perform battery discharge tests onsite. Customers can perform battery discharge tests onsite. One Key-010111 The fan speed varies depending on the ambient temperature and load power, which reduces noises. Fans are configured in redundancy. The fan rotation slows down in the case of low load power or low ambient temperatures, which decreases fan noises. One Key-010112 Abundant optional components contribute to an integrated solution. The abundant optional components can be flexibly configured to meet customer requirements in various scenarios. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 4 Feature ID Feature Name Description One Key-010113 The UPS complies with RoHS 6. The RoHS was adopted by the European Union. The RoHS directive took effect on 1 July 2006. One Key-010114 Cables are routed from the bottom. Cables are routed from the bottom. One Key-010115 The UPS is protected to IP20. IP20 is described as follows: 2 - Prevent foreign objects with a diameter of greater than 12 mm and with a length of not more than 80 mm from entering the cabinet; prevent fingers from touching the electrical components or moving components inside the cabinet. 0 - No protection The first feature code involves dust prevention, and the second feature code involves water prevention. One Key-010116 The software supports online upgrade. The software supports online upgrade. Enhancement N/A Dependency N/A 1.2 Input Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-020101 Three-phase, four-wire, and PE wire One Key-020102 The input voltage has a wide range: 80–280 V AC. The load power is not derated at 176–280 V AC, and is derated at 80–176 V AC. One Key-020103 The input voltage and frequency have a wide range. The frequency is 40–70 Hz. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 5 Feature ID Feature Name One Key-020104 The input PF is high: > 0.99 at full load and > 0.98 at 50% load. One Key-020105 The total distortion of the input current waveform (THDi) is small: < 3% at full linear load. One Key-020106 Input current limiting and intelligent generator functions adapt the UPS to various diesel generators. Benefits Feature ID Feature Name Benefit One Key-020101 Three-phase, four-wire, and PE wire Three-phase, five-wire One Key-020102 The input voltage has a wide range: 80–280 V AC. The load power is not derated at 176–280 V AC, and is derated at 80–176 V AC. This feature reduces the battery discharge possibility and lengthens the battery lifespan. One Key-020103 The input voltage and frequency have a wide range. The frequency is 40–70 Hz. This feature reduces the battery discharge possibility and lengthens the battery lifespan. One Key-020104 The input PF is high: > 0.99 at full load and > 0.98 at 50% load. The input PF is high, which improves energy utilization. One Key-020105 The THDi is small: < 3% at full linear load. This feature improves voltage quality and reduces cable loss. One Key-020106 Input current limiting and intelligent generator functions adapt the UPS to various diesel generators. This feature reduces impulse currents and diesel generator usage capacity. Feature ID Feature Name Description One Key-020101 Three-phase, four-wire, and PE wire Input voltage mode: L1, L2, L3, N, and PE One Key-020102 The input voltage has a wide range: 80–280 V AC. The load power is not derated at 176–280 V AC, and is derated at 80–176 V AC. The input voltage ranges from 80 V AC to 280 V AC. When the system is not overloaded, the UPS works in normal mode. Description Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 6 Feature ID Feature Name Description One Key-020103 The input voltage and frequency have a wide range. The frequency is 40–70 Hz. The input frequency ranges from 40 Hz to 70 Hz. The UPS output frequency meets requirements. One Key-020104 The input PF is high: > 0.99 at full load and > 0.98 at 50% load. The input PF is high. One Key-020105 The THDi is small: < 3% at full linear load. The THDi is less than 3%. One Key-020106 Input current limiting and intelligent generator functions adapt the UPS to various diesel generators. The UPS adapts to various diesel generators. Enhancement N/A Dependency N/A 1.3 Bypass and Output Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-030101 The output voltage level is 380 V, 400 V, or 415 V. One Key-030102 The rated output voltage can be adjusted in the range of ±5%. One Key-030103 The rated output frequency is 50 Hz or 60 Hz. One Key-030104 The output PF is 1. With the same rated capacity, the UPS supplies more active power than the peer product that has an output PF of 0.8, satisfying IT applications much better. One Key-030105 The output current crest factor is 3:1. One Key-030106 The output regulated voltage precision is high. The tolerance is less than 1% at 100% stable balanced load. One Key-030107 The total harmonic distortion of output voltage (THDu) is small: ≤ Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 7 Feature ID Feature Name 1% (linear load) or ≤ 4% (non-linear load). One Key-030108 Three-phase output voltage phase deviation is small. ±1 degree (balanced load) ±2 degree (100% unbalanced load) One Key-030109 The frequency tolerance is less than ±0.25% (local frequency mode). One Key-030110 The overload capability is powerful: 60 min (105%–110% rated current), 10 min (111%–125% rated current), or 60s (126%–150% rated current). One Key-030111 The inverter has a powerful capability against load impact. The maximum output short-circuit time is 200 ms. One Key-030112 The UPS adapts well to capacitive loads. One Key-030113 The bypass voltage has a wide range: –40% to +20%. One Key-030114 The rated inverter frequency has a tolerance of ±6 Hz. One Key-030115 The inverter tracking frequency is 0.6 Hz/s to favor the power supply from diesel generators. One Key-030116 The UPS features uninterruptible power supply and synchronous transfer. One Key-030117 The UPS supports economy control operation (ECO) mode. One Key-030118 Circuits are designed in redundancy, which improves system reliability. Benefits Feature ID Feature Name Benefit One Key-030101 The output voltage level is 380 V, 400 V, or 415 V. The UPS is suitable in various markets. One Key-030102 The rated output voltage can be adjusted in the range of ±5%. Customers can adjust the output voltage flexibly. One Key-030103 The rated output frequency is 50 Hz or 60 Hz. The UPS is suitable in various markets. One Key-030104 The output PF is 1. With the same rated capacity, the UPS supplies more active power than the peer product that has an output PF of 0.8, satisfying IT applications much better. With an output PF of 1, the UPS can supply power to more loads at the same power. One Key-030105 The output current crest factor is 3:1. The UPS supports non-linear loads. One Key-030106 The output regulated voltage precision is The UPS provides Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 8 Feature ID Feature Name Benefit high. The tolerance is less than 1% at 100% stable balanced load. high-quality output voltages. One Key-030107 The THDu is small: ≤ 1% (linear load) or ≤ 4% (non-linear load). The UPS provides high-quality output voltages. One Key-030108 Three-phase output voltage phase deviation is small. ±1degree (balanced load) ±2 degree (100% unbalanced load) This feature adapts the UPS well to unbalanced loads. One Key-030109 The frequency tolerance is less than ±0.25% (local frequency mode). The UPS provides high-quality output voltages. One Key-030110 The overload capability is powerful: 60 min (105%–110% rated current), 10 min (111%–125% rated current), or 60s (126%–150% rated current). This feature improves system reliability. One Key-030111 The inverter has a powerful capability against load impact. The maximum output short-circuit time is 200 ms. This feature improves system reliability. One Key-030112 The UPS adapts well to capacitive loads. The UPS supports non-linear loads. One Key-030113 The bypass voltage has a wide range: –40% to +20%. This feature improves the overload capability. One Key-030114 The rated inverter frequency has a tolerance of ±6 Hz. This feature reduces the battery discharge possibility and lengthens the battery lifespan. One Key-030115 The inverter tracking frequency is 0.6 Hz/s to favor the power supply from diesel generators. This feature provides a wide range of inverter tracking frequencies. One Key-030116 The UPS features uninterruptible power supply and synchronous transfer. This feature ensures uninterruptible power supply. One Key-030117 The UPS supports ECO mode. The UPS is efficient, energy-saving, and cost-effective. One Key-030118 Circuits are designed in redundancy, which improves system reliability. This feature improves system reliability. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 9 Description Feature ID Feature Name Description One Key-030101 The output voltage level is 380 V, 400 V, or 415 V. The output voltage can be set to 380 V, 400 V, or 415 V. One Key-030102 The rated output voltage can be adjusted in the range of ±5%. The rated output voltage can be slightly adjusted in the range of ±5%. One Key-030103 The rated output frequency is 50 Hz or 60 Hz. The rated output frequency can be set to 50 Hz or 60 Hz. One Key-030104 The output PF is 1. With the same rated capacity, the UPS supplies more active power than the peer product that has an output PF of 0.8, satisfying IT applications much better. Output active power is equal to apparent power. One Key-030105 The output current crest factor is 3:1. The UPS meets the requirement that the crest output current triples the rated current. One Key-030106 The output regulated voltage precision is high. The tolerance is less than 1% at 100% stable balanced load. The output regulated voltage precision is high. The output voltage tolerance is less than 1% at 100% stable balanced load. One Key-030107 The THDu is small: ≤ 1% (linear load) or ≤ 4% (non-linear load). The THDu is small: ≤ 1% (linear load) or ≤ 4% (non-linear load). One Key-030108 Three-phase output voltage phase deviation is small. ±1degree (balanced load) ±2 degree (100% unbalanced load) Three-phase output voltage phase deviation is small. ±1degree (balanced load) ±2 degree (100% unbalanced load) One Key-030109 The frequency tolerance is less than ±0.25% (local frequency mode). The frequency precision is high. One Key-030110 The overload capability is powerful: 60 min (105%–110% rated current), 10 min (111%–125% rated current), or 60s (126%–150% rated current). The overload capability is powerful: 60 min (105%–110% rated current), 10 min (111%–125% rated current), or 60s (126%–150% rated current). One Key-030111 The inverter has a powerful capability The inverter has a Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 10 Feature ID Feature Name Description against load impact. The output short-circuit time reaches a maximum of 200 ms. powerful capability against load impact. The maximum output short-circuit time is 200 ms. One Key-030112 The UPS adapts well to capacitive loads. The UPS supports non-linear loads. One Key-030113 The bypass voltage has a wide range: –40% to +20%. The bypass voltage has a wide range: –40% to +20%. One Key-030114 The rated inverter frequency has a tolerance of ±6 Hz. The inverter tracking frequency tolerance is ±5 Hz. One Key-030115 The inverter tracking frequency is 0.6 Hz/s to favor the power supply from diesel generators. The inverter tracking frequency can be set to 0.6 Hz/s. One Key-030116 The UPS features uninterruptible power supply and synchronous transfer. In the synchronous tracking scope, the UPS can transfer from normal mode to bypass mode without interruptions. One Key-030117 The UPS supports ECO mode. The bypass can supply power directly to loads if the bypass voltage is within the specified range. One Key-030118 Circuits are designed in redundancy, which improves system reliability. This feature provides centralized control and active/standby backup. Enhancement N/A Dependency N/A 1.4 Battery Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 11 Summary Feature ID Feature Name One Key-040101 The battery voltage has a wide range. The number of batteries is 30–40, 32 by default. One Key-040102 The UPS supports lead-acid batteries (open or valve regulated). One Key-040103 The battery charging capability is 4.5 kW, 40 kVA. One Key-040104 The UPS supports one-button cold startup. During a mains outage, batteries can start the UPS to supply power to loads. One Key-040105 Intelligent management, automatic temperature compensation, backup time assessment, capacity monitoring, and battery self-check and maintenance Benefits Feature ID Feature Name Benefit One Key-040101 The battery voltage has a wide range. The number of batteries is 30–40, 32 by default. This feature provides various battery configuration methods. One Key-040102 The UPS supports lead-acid batteries (open or valve regulated). The battery type can be selected based on the actual requirements. One Key-040103 The battery charging capability is 4.5 kW, 40 kVA. This feature allows for rapid battery capacity recovery, which improves system reliability. One Key-040104 The UPS supports one-button cold startup. During a mains outage, batteries can start the UPS to supply power to loads. This feature reduces maintenance costs and supports battery cold startup. One Key-040105 Intelligent management, automatic temperature compensation, backup time assessment, capacity monitoring, and battery self-check and maintenance This feature maximizes battery utilization. Feature ID Feature Name Description One Key-040101 The battery voltage has a wide range. The number of batteries is 30–40, 32 by default. The battery voltage has a wide range. The number of batteries is 30–40, 32 by default. Description Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 12 Feature ID Feature Name Description One Key-040102 The UPS supports lead-acid batteries (open or valve regulated). The UPS supports lead-acid batteries (open or valve regulated). One Key-040103 The battery charging capability is 4.5 kW, 40 kVA. This feature ensures that the charger's charging capability reaches up to 10 A and ensures that battery capability rapidly recovers. One Key-040104 The UPS supports one-button cold startup. During a mains outage, batteries can start the UPS to supply power to loads. Batteries supply power to loads if the mains is abnormal. One Key-040105 Intelligent management, automatic temperature compensation, backup time assessment, capacity monitoring, and battery self-check and maintenance This feature maximizes battery utilization. Enhancement N/A Dependency N/A 1.5 System Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-050101 A maximum of two UPSs can be connected in parallel. Current unbalance is less than 5%. One Key-050102 The UPS supports expansion parallel connection, redundancy parallel connection, and hot backup redundancy. One Key-050103 A single UPS and a parallel system both support ECO mode. One Key-050104 The built-in digital bus synchronization controller (BSC) contributes to dual-bus solutions. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 13 Benefits Feature ID Feature Name Benefit One Key-050101 A maximum of two UPSs can be connected in parallel. Current unbalance is less than 5%. This feature allows for capacity expansion. One Key-050102 The UPS supports expansion parallel connection, redundancy parallel connection, and hot backup redundancy. This feature provides multiple system configuration methods. One Key-050103 A single UPS and a parallel system both support ECO mode. The UPS is efficient, energy-saving, and cost-effective. One Key-050104 The built-in digital BSC contributes to dual-bus solutions. This feature improves the reliability of power supply. Description Feature ID Feature Name Description One Key-050101 A maximum of two UPSs can be connected in parallel. Current unbalance is less than 5%. This feature enables the parallel system to work in 1+1 redundancy mode with a current unbalance of less than 5% and ensures load balance among UPSs in the parallel system. One Key-050102 The UPS supports expansion parallel connection, redundancy parallel connection, and hot backup redundancy. Expansion parallel connection: N UPSs supply power. The output loading capability is N x single-UPS loading capability Redundancy parallel connection: N+1 UPSs supply power. The output loading capability is N x single-UPS loading capability Hot backup redundancy: Two parallel systems supply power. The output loading capability is the loading capability of a single system. If the active system breaks down, the standby system supplies power. One Key-050103 A single UPS and a parallel system both support ECO mode. The bypass can supply power to loads when the requirements are met. One Key-050104 The built-in digital BSC contributes to dual-bus BSC: Two parallel systems, configured Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 14 Feature ID Feature Name Description solutions. in mutual backup, supply power to loads. Enhancement N/A Dependency N/A 1.6 User Interface Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-060101 The 2.2-inch LCD provides a user-friendly user interface. It supports audible and visual alarms and multiple languages. One Key-060102 The UPS stores historical records, displays alarms and other data, and provides log records, including battery discharge times. One Key-060103 The UPS provides various external communications ports, such as the RS485 and RJ45. It supports the network energy element management protocol, Modbus protocol, and SNMP. One Key-060104 Integrated management and monitoring of the equipment room, including the UPS One Key-060105 The UPS has remote management and communication functions. Benefits Feature ID Feature Name Benefit One Key-060101 The 2.2-inch LCD provides a user-friendly user interface. It supports audible and visual alarms and multiple languages. Provides all kinds of running data, operating status, and help information. One Key-060102 The UPS stores historical records, displays alarms and other data, and provides log records, including battery Provides historical records for preventive maintenance inspection. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 15 Feature ID Feature Name Benefit discharge times. One Key-060103 The UPS provides various external communications ports, such as the RS485 and RJ45. It supports the network energy element management protocol, Modbus protocol, and SNMP. Various communication and monitoring ports are available. One Key-060104 Integrated management and monitoring of the equipment room, including the UPS The UPS provides integrated network management solutions. One Key-060105 The UPS has remote management and communication functions. This feature improves the maintenance and use efficiency and reduces the operating cost. Feature ID Feature Name Description One Key-060101 The 2.2-inch LCD provides a user-friendly user interface. It supports audible and visual alarms and multiple languages. Displays and queries real-time information on the LCD. One Key-060102 The UPS stores historical records, displays alarms and other data, and provides log records, including battery discharge times. Users can query and remotely download information. One Key-060103 The UPS provides various external communications ports, such as the RS485 and RJ45. It supports the network energy element management protocol, Modbus protocol, and SNMP. The UPS provides various external communications ports, such as the RS485 and RJ45. It supports the network energy element management protocol, Modbus protocol, and SNMP. One Key-060104 Integrated management and monitoring of the equipment room, including the UPS Monitors the UPS system by using the network management system One Key-060105 The UPS has remote management, communication, and control functions. The UPS has remote management, reporting, and control functions. Description Enhancement N/A Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 16 Dependency N/A 1.7 Alarm Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-070101 The mains voltage is abnormal. One Key-070102 The mains frequency is abnormal. One Key-070103 The mains phase sequence is reversed. One Key-070104 The mains neutral wire is absent. One Key-070105 The bypass input is abnormal. One Key-070106 The bypass frequency is abnormal. One Key-070107 The bypass phase sequence is reversed. One Key-070108 The bypass neutral wire is absent. One Key-070109 Battery undervoltage protection is triggered. One Key-070110 Batteries are not connected. One Key-070111 Battery terminals are reversely connected. One Key-070112 The rectifier is abnormal. One Key-070113 The auxiliary power supply is abnormal. One Key-070114 The inverter is abnormal. One Key-070115 The inverter is not synchronized. One Key-070116 The bypass unit is abnormal. One Key-070117 Bus overvoltage or undervoltage is triggered. One Key-070118 The fan is faulty. One Key-070119 The output is overloaded. One Key-070120 Overtemperature protection is triggered. One Key-070121 The inter-rack parallel cable is abnormal. One Key-070122 The unit is not detected. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 17 Benefits Feature ID Feature Name Benefit One Key-070101 The mains voltage is abnormal. Monitors the UPS and reports alarms in real time. One Key-070102 The mains frequency is abnormal. Monitors the UPS and reports alarms in real time. One Key-070103 The mains phase sequence is reversed. Monitors the UPS and reports alarms in real time. One Key-070104 The mains neutral wire is absent. Monitors the UPS and reports alarms in real time. One Key-070105 The bypass input is abnormal. Monitors the UPS and reports alarms in real time. One Key-070106 The bypass frequency is abnormal. Monitors the UPS and reports alarms in real time. One Key-070107 The bypass phase sequence is reversed. Monitors the UPS and reports alarms in real time. One Key-070108 The bypass neutral wire is absent. Monitors the UPS and reports alarms in real time. One Key-070109 Battery undervoltage protection is triggered. Monitors the UPS and reports alarms in real time. One Key-070110 Batteries are not connected. Monitors the UPS and reports alarms in real time. One Key-070111 Battery terminals are reversely connected. Monitors the UPS and reports alarms in real time. One Key-070112 The rectifier is abnormal. Monitors the UPS and reports alarms in real time. One Key-070113 The auxiliary power supply is abnormal. Monitors the UPS and reports alarms in real time. One Key-070114 The inverter is abnormal. Monitors the UPS and reports alarms in real time. One Key-070115 The inverter is not synchronized. Monitors the UPS and reports alarms in real time. One Key-070116 The bypass unit is abnormal. Monitors the UPS and reports alarms in real time. One Key-070117 Bus overvoltage or undervoltage is triggered. Monitors the UPS and reports alarms in real time. One Key-070118 The fan is faulty. Monitors the UPS and reports alarms in real time. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 18 Feature ID Feature Name Benefit One Key-070119 The output is overloaded. Monitors the UPS and reports alarms in real time. One Key-070120 Overtemperature protection is triggered. Monitors the UPS and reports alarms in real time. One Key-070121 The inter-rack parallel cable is abnormal. Monitors the UPS and reports alarms in real time. One Key-070122 The unit is not detected. Monitors the UPS and reports alarms in real time. Description Feature ID Feature Name Description One Key-070101 The mains voltage is abnormal. An alarm is generated when the mains input voltage exceeds the specified range. One Key-070102 The mains frequency is abnormal. An alarm is generated when the mains input frequency exceeds the specified range. One Key-070103 The mains phase sequence is reversed. The mains power cables are connected in an incorrect phase sequence. One Key-070104 The mains neutral wire is absent. An alarm is generated when the UPS input neutral wire disconnects from the external power distribution neutral wire. One Key-070105 The bypass input is abnormal. An alarm is generated when the bypass input voltage exceeds the specified range. One Key-070106 The bypass frequency is abnormal. An alarm is generated when the bypass input frequency exceeds the specified range. One Key-070107 The bypass phase sequence is reversed. The bypass input power cables are connected in an incorrect phase sequence. One Key-070108 The bypass neutral wire is absent. An alarm is generated when the bypass neutral wire disconnects from the external power distribution neutral wire. One Key-070109 Battery undervoltage protection is triggered. Battery end of discharge (EOD) protection is triggered. One Key-070110 Batteries are not connected. An alarm is generated when batteries are not connected. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 19 Feature ID Feature Name Description One Key-070111 Battery terminals are reversely connected. An alarm is generated when battery terminals are reversely connected. One Key-070112 The rectifier is abnormal. An alarm is generated about rectifier soft-startup failure and overcurrent. One Key-070113 The auxiliary power supply is abnormal. An alarm is generated when the voltage of the auxiliary power supply is abnormal. One Key-070114 The inverter is abnormal. An alarm is generated when the inverter is abnormal. For example, the inverter short-circuits or open-circuits. One Key-070115 The inverter is not synchronized. An alarm is generated when the bypass is not phase-clocked. One Key-070116 The bypass unit is abnormal. An alarm is generated when the bypass unit is abnormal. For example, backfeed occurs, or the bypass thyristor short-circuits or open-circuits. One Key-070117 Bus overvoltage or undervoltage is triggered. An alarm is generated about bus overvoltage or undervoltage. One Key-070118 The fan is faulty. An alarm is generated when the fan deteriorates or is stalled. One Key-070119 The output is overloaded. An alarm is generated when the output power exceeds the rated value. One Key-070120 Overtemperature protection is triggered. An alarm is generated when the temperature is abnormal. One Key-070121 The inter-rack parallel cable is abnormal. An alarm is generated when the parallel cable is faulty or is not properly connected. One Key-070122 The unit is not detected. An alarm is generated when a unit cannot be detected. Enhancement N/A Dependency N/A Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 20 UPS5000 Feature Description 2 Optional Features 2 Optional Features 2.1 Environmental Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key -080101 Earthquake-proof components Benefits Feature ID Feature Name Benefit One Key -080101 Earthquake-proof components This feature ensures that the UPS works properly in earthquakes with weak intensity. Description Feature ID Feature Name Description One Key -080101 Earthquake-proof components This feature ensures that the UPS works properly in earthquakes with weak intensity. Enhancement N/A Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 21 Dependency N/A 2.2 Power Distribution Features Availability Summary Benefits Description Enhancement N/A Dependency N/A 2.3 Parallel System Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-100101 Parallel cable One Key-100102 BSC cable Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 22 Benefits Feature ID Feature Name Benefit One Key-100101 Parallel cable Connects UPSs in parallel. One Key-100102 BSC cable Part of a complete system solution Description Feature ID Feature Name Description One Key-100101 Parallel cable Transfers control and communication signals between the UPSs connected in parallel. One Key-100102 BSC cable Transfers control and communication signals between systems. Enhancement N/A Dependency N/A 2.4 Battery Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-110101 Battery circuit breaker (BCB) box One Key-110102 Battery temperature monitoring component Benefits Feature ID Feature Name Benefit One Key-110101 BCB box Controls the battery circuit breaker. One Key-110102 Battery temperature Improves battery reliability. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 23 Feature ID Feature Name Benefit monitoring component Description Feature ID Feature Name Description One Key-110101 BCB box Controls the battery circuit breaker. One Key-110102 Battery temperature monitoring component Improves battery reliability. Enhancement N/A Dependency N/A 2.5 Monitoring Features Availability This feature is introduced to UPS5000 V100R002 and later versions. Summary Feature ID Feature Name One Key-120101 Dry contact expansion One Key-120102 Backfeed protection Benefits Feature ID Feature Name Benefit One Key-120101 Dry contact expansion Provides additional dry contact signals. One Key-120102 Backfeed protection Provides backfeed protection. Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 24 Description Feature ID Feature Name Description One Key-120101 Dry contact expansion Provides five groups of signal output and input ports respectively, delivering abundant alarm and control functions. One Key-120102 Backfeed protection When backfeed occurs, the backfeed protection card sends signals to trigger alarm signals or quickly disconnect the feedback loop. Enhancement N/A Dependency N/A Issue 01 (2013-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 25 UPS5000 Feature Description 3 Acronyms and Abbreviations 3 Acronyms and Abbreviations B BCB battery circuit breaker BSC bus synchronization controller C CB Certification Bodies' Scheme CE Conformite Europeenne E ECO economy control operation EMC electromagnetic compatibility EOD end of discharge I IEC International Electrotechnical Commission L LCD liquid crystal display R RoHS restriction of the use of certain hazardous substances T THDi Issue 01 (2013-01-26) total distortion of the input current waveform Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 26 THDu total harmonic distortion of output voltage TLC Tell Certification Center U UPS Issue 01 (2013-01-26) uninterruptible power system Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 27