* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Practice use of the Digital Multimeter.
Transistor–transistor logic wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Operational amplifier wikipedia , lookup
Integrating ADC wikipedia , lookup
Josephson voltage standard wikipedia , lookup
Oscilloscope history wikipedia , lookup
Schmitt trigger wikipedia , lookup
Oscilloscope types wikipedia , lookup
Tektronix analog oscilloscopes wikipedia , lookup
Surface-mount technology wikipedia , lookup
Electrical ballast wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power MOSFET wikipedia , lookup
Current source wikipedia , lookup
Voltage regulator wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Current mirror wikipedia , lookup
Surge protector wikipedia , lookup
Rectiverter wikipedia , lookup
CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Name: Derek Molloy Title: E3 The Digital Multimeter (DMM). Class: CIMC2 Report Date: 05 May 2007 Page 1 of 8 Practical Technologies (CIMC2): E3 The Digital Multimeter 1) Abstract: This report discusses a lab experiment to practice the use of the Digital Multimeter by taking measurements of many different components. The report shows the competence of the user in verifying component values and taking circuit readings. ____________________________________________ 2) Introduction: As part of this Lab exercise I’ve given details of my personal DMM. I’ve also supplied a note on safety precautions to be aware of when carrying out voltage and current measurements. This is followed by detailed information on the how to set up the meter for the different applications. The main body of the exercise covers the measurements and calculations taken on the 13th of January 2007 where resistances, currents and voltages were taken of combinations of resistors. An oscilloscope was used on the day to compare and verify RMS voltage readings. Theoretical calculations were used to compare and verify readings. The forward break down voltage of a diode was measured. Finally the values of capacitors were measured. ____________________________________________ 3) Main body of Report All readings were taken with my own personal Multimeter details below: Fluke 789 ProcessMeter™ Double your power. Fluke combined a loop calibrator and a DMM to give process technicians double the power in one tool (the Fluke 787). Now we made it even better "the ultimate loop calibration multimeter" the Fluke 789 ProcessMeter. The 789 has a display that's not only twice as large, but also twice as bright with two levels of backlighting. With its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you. Now process technicians can do a lot more while carrying a lot less. Figure 1 Key features of the Fluke 789 24 V Loop power supply Page 2 of 8 Practical Technologies (CIMC2): E3 The Digital Multimeter HART mode setting with loop power (adds 250 ohm resistor) 100 % larger dual display 1,200 ohm drive capability on mA source Enhanced backlight with two brightness settings 0-100 % mA Span Check buttons to toggle between 4 and 20 mA Infrared I/O serial port compatible with FlukeView? Forms Software Version 2.1 (available Feb. 2003) Externally accessible fuses for easy replacement DMM designed to meet 1000 volt IEC 1010 CAT III standards Precision 1000 V, 440 mA true-rms digital multimeter Frequency measurement to 20 kHz Min/Max/Average/Hold/Relative modes Diode Test and Continuity Beeper Simultaneous mA and % of scale readout 20 mA dc current source / loop calibrator / simulator Manual Step (100 %, 25 %, Coarse, Fine) plus Auto Step and Auto Ramp Externally accessible battery for easy battery changes IR communication port allows data to be logged to optional FlukeView Forms® software for graphical analysis and reporting Safety: Conforms to European Union Directive 73/23/EEC EN61010-1, CAT III and CAT IV Note: to practice the use of the Digital Multimeter by taking measurements of many different components. It is essential that the DMM is set up to the correct mode and that the leads are in the correct sockets. Further more it is essential to ensure that there is no voltage present for resistance or diode tests and that the maximum voltage or current measurement limits are not exceeded to prevent damage to the DMM or the user. The user has to ensure that all precautions are taken to avoid electrocution when taking measurements on high voltage circuits and charged capacitors (when constructing circuits involving capacitors it is essential that they are orientated correctly to avoid them burning out). Only a competent user should be using the equipment. If there is any uncertainty regarding the safe use of the equipment of safety to them selves they should seek advice prior to use of the equipment. Page 3 of 8 Practical Technologies (CIMC2): E3 The Digital Multimeter To measure resistance Setup meter mode to read resistance. Connect the leads across the CAT III 1000V The meter can be left on “Auto Range” or “Manual Range”. Table 1 To measure voltage Setup meter mode to read either AC voltage. Setup meter mode to read either DC voltage Connect the leads across the CAT III 1000V The meter can be left on “Auto Range” or “Manual Range”. Table 2 To measure current Setup meter mode to read either AC or DC current (Automatic selection). Connect the leads across the 0.44A FUSED for AC or DC up to 0.44A Connect the leads across the 30mA FUSED for DC up to 30mA The meter can be left on “Auto Range” or “Manual Range”. Table 3 Page 4 of 8 Practical Technologies (CIMC2): E3 The Digital Multimeter Part (1). Resistor Values and DMM Voltage. Set up DMM to measure resistance (as in Table 1). Connect the leads across the selected resistors and record the resistance values (Results in Table 4) Set up DMM to measure voltage (as in Table 2). Connect the leads across the selected resistors and record the voltage values (Results in Table 4) Resistor Values DMM Voltage Units Units (Ohms) (Volts DC) 119.6 2.316 148.1 2.316 180.0 2.316 56.0 2.681 Table 4 Part (2). Resistor Values and DMM Current. Set up DMM to measure resistance (as in Table 1). Connect the leads across the selected resistors and record the resistance values (Results in Table 5) Set up DMM to measure current (as in Table 3). Connect the leads in line the selected resistors and record the current values (Results in Table 5) Resistor Values Units (Ohms) 119.6 + 56 (L1 + L4) 148.1 + 56 (L2 + L4) 180.0 + 56 (L3 + L4) (119.6, 148.1, 180.0) + 56 (L4) Table 5 DMM Current Units (Amps DC) 0.028 0.024 0.021 0.047 Part (3). Resistor Values, Oscilloscope Route Mean Square (RMS) Amplitude and DMM RMS Voltage. Set up DMM to measure resistance (as in Table 1). Connect the leads across the selected resistors and record the resistance values (Results in Table 6) Set up DMM to measure voltage (as in Table 2). Connect the leads across the selected resistors and record the voltage values (Results in Table 6) Verify the measured voltage with Oscilloscope set to read RMS Amplitude Volts AC. Resistor Values Oscilloscope RMS Amplitude DMM RMS Voltage Units (Ohms) Units (Volts AC RMS) Units (Volts AC RMS) 119.6 0.509 0.51 148.1 0.509 0.51 180.0 0.509 0.51 825.0 7.07 6.96 3300.0 7.07 6.96 Table 6 Page 5 of 8 Practical Technologies (CIMC2): E3 The Digital Multimeter Comparison of DMM RMS Voltage versus Oscilloscope RMS Amplitude 0.001 0.51 0.509 0.001 0.002 X 100 0.2% 0.51 & 0.11 6.96 7.07 0.11 0.0158 X 100 1.58% 6.96 Part (4). Measured AC current through the parallel combination of the 3.3kΩ and 820Ω resistors: Set up DMM to measure current (as in Table 3). Connect the leads in line the selected resistors and record the current values (Results in Table 7) 0.011Amps AC ( at 7.43Volts AC) Table 7 7.43 Volts Amps Verification: 0.0113125 A Re sis tan ce 1 1 656.796 1 1 1 3300 820 656.796 Part (5). Calculated effective resistance of the combination: Set up DMM to measure resistance (as in Table 1). Connect the leads across the selected resistors and record the resistance values. Verification: 1 1 660 1 1 1 3300 825 660 Part (6). Theoretical value of the combination: 1 1 656.796 1 1 1 3300 820 656.796 Page 6 of 8 Practical Technologies (CIMC2): E3 The Digital Multimeter Part (7). Condition of a diode using the diode test function of the DMM: To measure diode condition. Setup meter mode to read the forward break down voltage of the diode by selecting the mode and pressing the blue button. Connect the leads across the CAT III 1000V The meter will read “Manual Range 4” and give DC voltage reading. Table 8 Part (7). (Continued) Set up DMM to measure diode condition (as in Table 8). Connect the leads across the selected diode and record the voltage values (Results in Table 6) 0.495 Volts DC Table 9 Part (8). Values of the capacitors measured with DMM: Set up DMM to measure capacitance. Connect the leads across the selected capacitor and record the capacitance values (Results in Table 10) Capacitor Value Units ( µF ) 10 15 22 DMM Measured Capacitance Units (µF) 7.16 14.9 20.8 Table 10 ____________________________________________ 4) Conclusion: The objective of this lab to practice taking measurements of resistors, capacitors and diodes using a digital multimeter is to develop and improve the proficiency of a new user to the use of a digital multimeter. The exercise shows the variations likely to be found between the recorded value versus the stated value of different devices. Also the possibility of inaccuracies due to errors being introduced through various quality of connection to devices, the allowable tolerances of the devices, the addition of test leads and the possibility of errors in the measurement instrument. Page 7 of 8 Practical Technologies (CIMC2): E3 The Digital Multimeter The values of the resistances fell within the tolerances stated on the devices. The Comparison of DMM RMS Voltage versus Oscilloscope RMS Amplitude gave an accuracy of 0.2 to 1.58% which is very good because of the combination of allowable tolerances in the DMM and the Oscilloscope. The larges errors were found between the capacitors values and the measured value of the DMM which could have been due to quality of connection to devices, the allowable tolerances of the devices, the addition of test leads and the possibility of errors in the measurement instrument. But over all the values recorded come second to the experience gained from the exercise. ____________________________________________ 5) References: http://www.hach-korea.com/data/789-05.jpg http://us.fluke.com/usen/products/Fluke+789.htm?catalog_name=FlukeUnitedStates Back to home Page: http://Derek.Molloy.ie/ Page 8 of 8